首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A sensitive and selective liquid chromatographic tandem mass spectrometric method (LC/MS/MS) for the simultaneous detection of the ionophoric coccidiostats narasin, monensin, lasalocid and salinomycin in whole eggs has been developed. A very simple sample preparation consisting of an extraction with an organic solvent was carried out. Sample extracts were injected into the LC/MS/MS system on a C18 column and an isocratic elution was performed. Nigericin was used as internal standard. The precursor ions produced by electrospray positive ionisation were selected for collisional dissociation with argon into product ions. Validation of the methods was performed based on Commission Decision 2002/657/EC.1 CC(alpha) was found to be 1 microg/kg for all four compounds. Monitoring of Belgian egg samples in 2004 revealed that residues of salinomycin, lasalocid and monensin could be found.  相似文献   

2.
A rapid confirmatory liquid chromatographic/tandem mass spectrometic method was developed for determination of chloramphenicol in bovine milk. Chloramphenicol was extracted directly from milk by solid-phase extraction on a C18 cartridge. The extract was further cleaned up on neutral aluminium oxide. Three transition products were monitored in negative ion mode after atmospheric pressure chemical ionization. The detection capability related to the transition product of lowest abundance was 0.03 microg/kg. The mean recovery was 90% at levels of 0.1-0.2 microg/kg. The relative repeatability standard deviations were 4.3, 3.8, and 2.8% at levels of 0.1, 0.2, and 1.0 microg/kg, respectively.  相似文献   

3.
Antibiotics present in the environment are recently considered as emerging contaminants, and have raised increasing concerns about their potential risks to ecosystems and human health. In addition to the utilization for treatment, antibiotics are also routinely added as supplements in livestock feed to promote animal growth. A portion of the administered dose used for these purposes can be excreted into animal manure, and land application of the animal manure as plant fertilizers enhances the dissemination of antibiotics in the environment. It is a common practice to simultaneously administer multiple classes of antibiotics to livestock in an animal production farm. This study attempts to develop a protocol to determine four commonly used veterinary pharmaceuticals, amprolium, carbadox, monensin, and tylosin, in surface runoff from a livestock farm. A single-cartridge solid-phase extraction procedure was developed to simultaneously extract these veterinary antibiotics from surface water which were subsequently analyzed by liquid chromatography/tandem mass spectrometry. The extraction recoveries of spiked samples ranged from 89 to 113%, and the limits of quantitation were 8, 25, 1, and 35 ng/L for amprolium, carbodox, monensin, and tylosin, respectively. In the surface runoff from a livestock farm, amprolium was most frequently detected with the concentration range of 10-288 ng/L. Monensin was frequently detected with concentrations up to 37 ng/L. Tylosin was detected in two out of eleven samples, and carbadox was not detected in the surface runoff. The results indicate that the developed analytical method can be utilized to determine multiple classes of veterinary antibiotics present in surface runoff originating from animal farms.  相似文献   

4.
建立了鸡组织中聚醚类药物多残留检测的高效液相色谱-电喷雾串联质谱方法。采用甲醇提取鸡组织中的拉沙洛菌素、盐霉素、莫能菌素、甲基盐霉素和马杜霉素,经硅胶柱净化,以乙腈(含0.1%甲酸)-0.1%甲酸水溶液(体积比为97:3)为流动相,Symmetry Shield RP18作为色谱分析柱,多反应监测(MRM)正离子扫描方式进行质谱检测。当5种聚醚类药物的添加水平为鸡肉0.1~1500 μg/kg、鸡肝0.2~4500 μg/kg时,平均回收率为71.6%~99.1%,日内测定的相对标准偏差(RSD)(n=5)为3.2%~10.7%,日间RSD(n=3)为4.6%~14.7%。2种鸡组织中5种聚醚类药物的定量限为0.1~1.0 μg/kg。该方法的灵敏度、准确度和精密度均符合兽药残留分析技术的要求,适用于鸡肉和鸡肝中5种聚醚类药物的多残留检测。  相似文献   

5.
An ultra high performance liquid chromatography with tandem mass spectrometry method was established for the rapid and simultaneous analysis of seven antiviral drugs, amantadine, rimantadine, memantine, moroxydine, imiquimod, oseltamivir, and acyclovir, in chicken liver, muscle, and egg. Homogenized samples were extracted with trichloroacetic acid and acetonitrile solutions and then purified by cation‐exchange solid‐phase extraction. The target drugs were analyzed by liquid chromatography with a UPLC BEH Amide column (2.1 mm × 100 mm, 1.7 μm) coupled with a tandem mass spectrometer operating in the positive multiple‐reaction mode. A perfectly linear relationship was obtained within the concentration ranges of 0.5–20 μg/L for acyclovir and 0.1–10 μg/L for the other six antiviral drugs. The average recoveries of the seven antiviral drugs using four addition levels in chicken liver, muscle, and eggs were 82.67–90.10, 82.30–92.27, and 81.98–93.77%, respectively, and the acceptable coefficients of variation were 5.18–9.88, 4.84–11.2, and 42.8–9.95%, respectively. The detection limits and detection capabilities of the analysis method for the seven antiviral drugs were in the ranges of 0.04–0.64 and 0.11–0.78 μg/kg, respectively. Additionally, an inter‐laboratory study among five laboratories further validated the method.  相似文献   

6.
For the detection of 19 steroid hormones in bovine muscle, a fast and sensitive liquid chromatography with electrospray ionization tandem mass spectrometry method was developed using both positive and negative ionization mode. Chromatographic separation on Poroshell 120‐EC C18 column was achieved in less than 10 min using isocratic elution of mobile phase of acetonitrile/methanol/water. The compounds were extracted from muscle tissue using ethyl acetate and quick, easy, cheap, effective, rugged, and safe technique. The purification of the obtained extract was performed by dispersive solid‐phase extraction with sorbents C18, primary secondary amine and magnesium sulphate. The method was validated in accordance with the Commission Decision 2002/657/EC. For all steroids tested good recoveries were obtained (from 51.2 to 121.4%) in the concentration range from decision limits until 5 µg/kg. The values of decision limits and the detection capabilities for individual compounds were in the range 0.10–0.48 and 0.17–0.95 µg/kg, respectively. The method was characterized by satisfactory linearity for most compounds (correlation coefficients  > 0.99) and the reproducibility was lower than 35%. The elaborated procedure has met the criteria for confirmatory methods and is currently used in the official control of hormones.  相似文献   

7.
A novel, sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry) method with on-line extraction and clean-up for the screening and confirmation of residues of tetracyclines in kidney has been developed. After liquid extraction of homogenised kidney with McIlvain buffer, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean-up of the sample on-line. Detection of the analytes was achieved by positive electrospray ionization followed by multiple reaction monitoring. For each tetracycline the collisional decomposition of the protonated molecule to a unique, abundant fragment ion was monitored. The method has been validated for tetracycline, oxytetracycline, chlortetracycline and doxycycline. Calibration curves resulting from spiked blank kidney samples at the 100-1200 microgram/kg level showed good linear correlation. At the level of 600 microgram/kg both within- and between-day precision, as measured by relative standard deviation (RSD), were less than 7%. The limits of detection (LODs) for tetracycline, oxytetracycline, chlortetracycline and doxycyline were 18, 23, 24 and 21 microgram/kg, respectively. The limits of quantification (LOQs) for tetracycline, oxytetracycline, chlortetracycline and doxycyline were 36, 46, 47 and 42 microgram/kg, respectively. The recoveries ranged from 71 to 91%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of tetracyclines in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis.  相似文献   

8.
Gentamicin is a broad-spectrum aminoglycoside antibiotic widely used in veterinary medicine for the treatment of serious infections. The purpose of this study was to develop and validate a method to determine gentamicin residues in edible tissues of swine and calf. Extraction of gentamicin was performed using a liquid extraction with phosphate buffer containing trichloroacetic acid, followed by a solid-phase clean-up procedure on a CBA weak cation-exchange column. Tobramycin was used as the internal standard. After drying of the eluate, the residue was redissolved and further analyzed by reversed-phase liquid chromatography/electrospray ionization tandem mass spectrometry (MS/MS). Chromatographic separation of the internal standard tobramycin and the gentamicin components was achieved on a Nucleosil (5 microm) column using a mixture of 10 mM pentafluoropropionic acid in water and acetonitrile as the mobile phase. The gentamicin components C1a, C2 + C2a and C1 could be identified with the MS/MS detection, and subsequently quantified. The method was validated according to the requirements of the EC at the maximum residue limit (MRL) (100 ng g(-1) for muscle and fat, 200 ng g(-1) for liver and 1000 ng g(-1) for kidney), half the MRL and double the MRL levels. Calibration graphs were prepared for all tissues and good linearity was achieved over the concentration ranges tested (r > 0.99 and goodness of fit <10%). Limits of quantification of 25.0 ng g(-1) were obtained for the determination of gentamicin in muscle, fat, liver and kidney tissues of swine and calf, which correspond in all cases to at least half the MRLs. Limits of detection ranged between 0.5 and 2.5 ng g(-1) for the tissues. The within-day and between-day precisions (RSD) and the results for accuracy fell within the ranges specified. The method was successfully used for the determination of gentamicin in tissue samples of swines and calves medicated with gentamicin by intramuscular injection.  相似文献   

9.
建立了一种贝类组织中原多甲藻酸(azaspiracid, AZA)贝类毒素主要成分AZA1的高效液相色谱-串联质谱检测方法。本方法采用甲醇-水(80:20, v/v)溶液对贝类组织中AZA1进行提取,并用MAX阴离子交换固相萃取(SPE)柱富集净化,使用Atlantis dC18(150 mm×4.6 mm, 5.0 μm)色谱柱分离,以含有50 mmol/L甲酸和2 mmol/L甲酸铵的乙腈-水溶液(80:20, v/v)为流动相进行等度洗脱,质谱采用选择反应监测(SRM)模式。AZA1在5 min内获得完全分离,且在48.85~2 442 ng/L范围内线性良好,相关系数为0.998 1。该方法检出限(S/N=3)为11.00 pg/g,添加水平为36.64、73.27、146.54 pg/g时的平均回收率为75.8%~82.5%(n=6),相对标准偏差小于10%。利用该方法对采自大连、青岛、广州水产品市场上的112个贝类样品进行了分析,发现采自大连和广州的部分贝类样品中含有AZA1。结果表明,该方法具有简单、快速、灵敏度高等特点,能充分满足贝类中AZA1检测的要求。  相似文献   

10.
A rapid method is presented for the determination of 4 nitroimidazoles in poultry and swine muscle and eggs by liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS). Samples were extracted with acetonitrile, then evaporated the organic phase. After filtration, the extract was directly injected into the LC/ESI-MS/MS system. The LC separation was made on a C8 column by applying a gradient composed of water and acetonitrile. Overall average recoveries ranged from 50-86% for egg, 66-115% for poultry muscle, and 79-111% for swine muscle. The decision limits ranged from 0.05-0.25 microg/kg for egg, 0.07-0.27 microg/kg for poultry muscle, and 0.07-0.26 microg/kg for swine muscle; and detection capabilities ranged from 0.51-0.68 microg/kg for egg, 0.41-0.75 microg/kg for poultry muscle, and 0.53-0.78 microg/kg for swine muscle.  相似文献   

11.
In conjunction with an AOAC Task Group on dietary supplements, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was validated for measurement of 6 major alkaloids in raw ephedra sinica herb, ephedra extracts, ephedra tablets, complex dietary supplements containing ephedra, and a high-protein drink mix containing ephedra. The amount of ephedrine-type alkaloids present was determined by LC with mass selective detection. Six replicates of each matrix were analyzed on 3 separate occasions. The presence of 6 ephedrine-type alkaloids was detected at a level > 0.5 microg/g based on a 0.5 g sample. The standard curve range for this assay is from 0.02 to 1.0 microg/mL. Appropriate dilutions covered a wide range of specific alkaloid concentrations. The calibration curves for all 6 analytes had correlation coefficients > 0.995.  相似文献   

12.
Interlaboratory validation studies have been performed on 2 methods for the determination of chlormequat (CLQ) and mepiquat (MPQ). Both methods used identical extraction procedures and stable isotope internal standardization but differed in the use of liquid chromatography/mass spectrometry (LC/MS) or LC/tandem mass spectrometry (LC/MS/MS) for the determination, the amount of internal standard used, and the expected limit of detection. After addition of deuterated internal standards, CLQ and MPQ were extracted with methanol-water and determined by LC//MS or LC/MS/MS with positive electrospray ionization. Eight European laboratories participated in the LC/MS method study, analyzing mushroom, pear, wheat flour, and fruit puree with residues of CLQ in the range 0.040-1.19 mg/kg and of MPQ in the range 0.041-0.39 mg/kg. For CLQ, the Horwitz ratio (HoRat) values for individual test materials/levels were in the range 0.85-1.13 with a mean of 1.00, showing good method performance. For MPQ, the Ho values for mushroom, pear (both levels), and wheat flour were in the range 0.83-0.94, again indicating good method performance. For the determination of MPQ in infant food (fruit puree) at 0.041 mg/kg, the Ho was 1.7 when a value of 0 reported by one participant was excluded. In the LC/MS/MS study, in which 11 laboratories participated, a separate sample set was analyzed with residues of CLQ in the range 0.007-1.03 mg/kg and of MPQ in the range 0.008-0.72 mg/kg. Ho values for CLQ were in the range 0.27-1.36 and for MPQ in the range 0.51-2.10, all corresponding to acceptable method performance.  相似文献   

13.
14.
The use of gestagens in animal fattening is prohibited within the European Union. Recently, the use of spectrometric methods for the detection and confirmation of banned substances was made obligatory. Therefore, conventional high-performance liquid chromatographic (HPLC) methods have been superseded. It has been possible to couple a previously described HPLC method for the determination of acetyl-gestagens in kidney fat to tandem mass spectrometry (LC-MS/MS). The decision limits CCalpha and the detection capability CCbeta are found to be below the minimum required performance limit (MRPL) established for medroxyprogesterone acetate (MPA) at 1 microg kg(-1). The calculated values for CCalpha are as follows: megestrol acetate (MGA)--0.15 microg kg(-1), melengesterol acetate (MLA)--0.15 microg kg(-1), chlormadinone acetate (CMA)--0.37 microg kg(-1) and for medroxyprogesterone acetate (MPA)--0.24 microg kg(-1). The CCbeta values for these compounds have been determined as 0.19, 0.19, 0.47 and 0.32 microg kg(-1), respectively.  相似文献   

15.
A method for determination of triforine using high-performance liquid chromatography with electrospray tandem mass spectrometry was developed. A simple ethyl acetate extraction with solvent exchange into water/methanol was used for sample preparation. The method was validated at 0.01 and 0.05 mg kg(-1) levels in apple, tomato and tinned blackcurrants. Recoveries were in the range 56.6-99.8% and no matrix suppression or enhancement effects were observed.  相似文献   

16.
A method was developed and validated for determination and quantitation of tilmicosin residues in swine, cattle, and sheep edible tissues, as well as chicken fat, skin, and muscle over a concentration range of 0.025 microg/g-20 microg/g. For chicken kidney and liver, the method was validated over a range of 0.060 microg/g-20 microg/g. The tissue sample was extracted with methanol and a C18 cartridge was used for solid-phase extraction cleanup. A reversed-phase gradient liquid chromatographic method with detection at 280 nm was used to separate the tilmicosin from matrix components in 30 min run time. The limit of quantitation (LOQ) of the method was 0.025 microg/g for all tested tissues except chicken kidney and liver, for which the LOQ was 0.06 microg/g. Average recoveries for tissue samples ranged from 73 to 98%. Relative standard deviation values ranged from 0.6 to 14.7%.  相似文献   

17.
This paper describes a rapid extraction method, based on a matrix solid-phase dispersion technique using diatomaceous earth as solid support and 50:50 (v/v) chloroform/methanol as extracting solvent, that can determine 11 free fatty acids in chocolate. The extraction procedure is followed by reversed-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) using a normal-bore (4.6 mm i.d.) C-18 column and an electrospray interface operating in the negative ion mode. The tandem mass spectra of selected compounds show that charge-remote fragmentation (CRF) mechanisms are occurring; the intensities of the CRF reactions increase with the carbon number and degree of unsaturation of the fatty acids. Average recoveries, evaluated by the standard addition method, vary between 79-103%, and the estimated quantification limits are less than 153 ng/g. The proposed method has been used to analyse nine chocolate samples from various price ranges, bought from supermarkets.  相似文献   

18.
In this work, two analytical methods based on liquid chromatography coupled to electrospray time-of-flight mass spectrometry (LC/ESI-TOFMS) and tandem mass spectrometry (LC/ESI-MS/MS) are described for the identification, confirmation and quantitation of three insecticides non-authorized in the European Union (nitenpyram, isocarbophos and isofenphos-methyl) but detected in recent monitoring programmes in pepper samples. The proposed methodologies involved a sample extraction procedure using liquid-liquid partition with acetonitrile followed by a cleanup step based on dispersive solid-phase extraction. Recovery studies performed on peppers spiked at different fortification levels (10 and 50 microg kg(-1)) yielded average recoveries in the range 76-100% with relative standard deviation (RSD) (%) values below 10%. Identification, confirmation and quantitation were carried out by LC/TOFMS and LC/MS/MS using a hybrid triple quadrupole linear ion trap (QqLIT) instrument in multiple-reaction monitoring (MRM) mode. The obtained limits of quantitation (LOQs) were in the range 0.1-5 microg kg(-1), depending on each individual technique. Finally, the proposed methods were successfully applied to the analysis of suspected pepper samples.  相似文献   

19.
A method has been developed for the simultaneous extraction and determination of five of the most commonly used anticoccidial drugs (nicarbazin, lasalocid, monensin, narasin and salinomycin) from livers and eggs by LC-MS-MS. Results show good repeatability, with mean spiked recoveries for nicarbazin, lasalocid, monensin, narasin and salinomycin in poultry livers in the average range of 92-118%, and 86-110% in eggs. The detection limit is at 1 ng ml(-1) for all the named compounds and a quantitation level of 2.5 ng g(-1) has been achieved. A high throughput of samples is achievable using this method which allows the analysis of up to 40 samples by one analyst in a day.  相似文献   

20.
A method using liquid chromatography with tandem mass spectrometry was developed for the determination of 11 commonly used aminoglycoside antibiotics in meat. The proposed method is sufficiently sensitive (detection limits of 15 to 40 ppb for the various antibiotics) and highly selective. It is suitable for the quantitation and confirmation of aminoglycosides in a variety of matrixes (pork muscle, fish, and veal liver). Any multiresidue method for aminoglycosides must take into account their high affinity toward sample proteins and the significantly different pK values of the various analytes. The developed method uses a low-pH extraction with trichloracetic acid to ensure complete extraction of the analytes from the matrix. An anion-exchange step is used to remove the acid from the centrifuged extract. Aminoglycosides in this solution of low ionic strength can be quantitatively retained and afterwards eluted from a weak cation-exchanger solid-phase extraction (SPE) cartridge. The highly selective SPE steps produce clean extracts, which minimize possible suppression of the mass spectrometer signal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏