首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A highly sensitive and selective reaction of 12-molybdophosphate with the polymethine dye Astra Phloxine has been used for the spectrophotometric determination of phosphate. If the concentration of phosphate is less than 1 μmol L−1, supersaturated solutions of ion associate (IA) are stable without the use of a surfactant. Under these conditions, a new band appears in the absorption spectrum at 574 nm. The color of the IA develops immediately after mixing of reagents and remains constant over several hours. The molar absorptivity of the IA is 1.54 × 105 L mol−1 cm−1. The calibration graph is linear between 0.02 and 0.8 μmol L−1 of phosphate. The limit of detection is 7 nmol L−1. Phosphate was determined in pure chemicals and water samples, including Dead Sea water.  相似文献   

2.
A procedure for the automatic photometric determination of phosphate ions in natural waters was developed, based on the formation of a colored ion associate of the reduced form of phosphomolybdic heteropoly anion with a polymethine dye, Astra Phloxine. The detection limit was 5 μg P/L at the sample volume of 0.3 mL.  相似文献   

3.
A novel and automated sequential injection procedure is proposed for the spectrophotometric determination of orthophosphate without requiring unstable chemical reducing species used in the classical molybdenum blue method. The flowing methodology is based on the on-line generation of the detectable species by electrochemical reduction of the 12-molybdophosphoric acid complex using a stainless steel tubular flow-through working electrode. The established method is linear up to 20 mg/l P, with coefficients of variation (n=10) of 2.4 and 1.8% for 2.0 and 10 mg/l P, respectively. The versatility of the sequential injection method to analyse samples containing high orthophosphate levels has been demonstrated by the implementation of a dilution chamber as well as flow-reversal techniques, yielding relative standard deviations (n=17) better than 2.0% for standards containing 200 and 800 mg/l P. The proposed analyser features an extremely wide dynamic range (viz., 0.3-800 mg/l) as well as improved tolerance to silicate interference, so that Si/P ratios higher than 50 are tolerated at the 5% level. Electrochemical conditions, reagent concentrations and physical variables have been thoroughly investigated. The method has been applied to the determination of orthophosphate in wastewaters as well as beverages and biological samples containing high concentrations of the target analyte. The t-test comparison of the means for the developed sequential injection system with electroreduction and both the molybdenum blue classical spectrophotometric batch procedure and inductively coupled plasma-optical emission spectrometric detection selected as external reference methods revealed that there is no evidence of significant differences between the obtained results at the 95% confidence level.  相似文献   

4.
Ohno S  Teshima N  Sakai T  Grudpan K  Polasek M 《Talanta》2006,68(3):527-534
A sequential injection (SI) method in a lab-on-valve (LOV) format for simultaneous spectrophotometric determination of copper and iron has been devised. The detection chemistry is based on the complex formation of 2-(5-bromo-2-pyridylazo)-5-[N-n-propyl-N-(3-sulfopropyl)amino]aniline (5-Br-PSAA) with copper(II) and/or iron(II) at pH 4.6. Copper(II) reacts with 5-Br-PSAA to form the complex which has an absorption maximum at 580 nm but iron(III) does not react. In the presence of a reducing agent only iron(II)-5-Br-PSAA complex is formed and detected at 558 nm. Under the optimum experimental conditions, the determinable ranges are 0.1-2 mg l−1 for copper and 0.1-5 mg l−1 for iron, respectively, with a sampling rate of 18 h−1. The limits of detection are 50 μg l−1 for copper and 25 μg l−1 for iron. The relative standard deviations (n = 15) are 2% for 0.5 mg l−1 copper and 1.8% for 0.5 mg l−1 iron when determined in standard solutions. The recoveries range between 96 and 105% when determining 0.25-2 mg l−1 of copper and 0.2-5 mg l−1 of iron in artificial mixtures at copper/iron ratios of 1:10 to 5:1. The proposed SI-LOV method is successfully applied to the simultaneous determination of copper and iron in multi-element standard solution and in industrial wastewater samples.  相似文献   

5.
A simple and sensitive sequential injection spectrophotometric procedure is proposed for the determination of trace amounts of iodide in pharmaceutical preparations. The method is based on the catalytic effect of iodide on the (tetra base) 4,4′-methylenebis(N,N-dimethylaniline)-chloramine-T reaction in acidic solution. The method involves a sequential aspiration of 255 μl sample/standard followed by 170 μl tetra base and then 128 μl chloramine-T solutions into a carrier stream to be stacked inside a holding coil and flow reversed through a reaction coil towards a detector. The resulting colored compound is measured at 600 nm using an UV/Vis-spectrophotometer. All the parameters that affect the reaction were evaluated and the calibration curve is linear over a range of 0.1–6.0 μg l−1 of iodide concentration with detection limit of 0.05 μg l−1. A sample throughput of 80 samples per hour and relative standard deviation of less than 2.0% was achieved. The method is successfully applied for the determination of iodide in three different samples (tablets).  相似文献   

6.
V. Gómez  M.P. Callao 《Talanta》2007,71(3):1393-1398
A sequential injection (SI)-DAD spectrophotometric method to control the exhaustion of dyes in a mixture of three dyes from a tanning industry process has been developed. It is based on an interdiffusion process of the sample and reagents which leads to a gradual fall in pH through the channel to the detector recording a data matrix. The aim of this paper is to develop a second-order calibration model that is unaffected by interferents by applying multivariate curve resolution with alternating least squares (MCR-ALS). We obtained a linear calibration in the 5-30 mg l−1 range with a correlation coefficient of 0.999 for each dye with detection limits of 2.6, 3.9 and 2.1 mg l−1 for Acid Red, Acid Brown and Acid Orange, respectively. The simultaneous determination of the three dyes from tanning samples showed a satisfactory precision for the three analytes. The method has been validated comparing the concentration of some spiked samples with the expected concentration using a t-paired test. When we used this method to study the exhaustion of dyes, we found that there were several stages in this process. These data may be the key to optimising the exhaustion process.  相似文献   

7.
Frank C  Schroeder F  Ebinghaus R  Ruck W 《Talanta》2006,70(3):513-517
A sequential injection analysis system (SIA) is described which is suited for the fast determination of filterable molybdate reactive phosphate (FRP, 0.2 μm) in coastal waters. It processes up to 270 samples per hour with a detection limit (3σ) of 0.05 μM and is used for surface mapping of phosphate in areas with steep concentration gradients like the Wadden Sea. The determination is based on the reaction of phosphate with acidic molybdate to phosphomolybdate, which builds non-fluorescent ion pairs with rhodamine 6G. The remaining rhodamine fluorescence is detected at 550 nm with an excitation at 470 nm. Syringe pump, valve and detector were controlled by a self made python programme, which was optimised for high speed SIA measurements in monitoring applications.  相似文献   

8.
Sequential injection with “Lab-at-Valve (LAV)” approach is demonstrated for potentiometric determination of chloride. The LAV flow-through electrode system consists of two Ag/AgCl electrodes: one as a reference electrode, silver chloride activated surface-silver wire soaked in a constant-concentration chloride ion solution in a small tube covered with a polymer-membrane, another as a working electrode (a similar silver chloride activated surface-silver wire) placed in a flow channel. The electrode system is attached at one port of a 10 port multiposition valve. A modified autoburette was used as a propelling device. Using SI operation via a program written in-house, based on LabVIEW®, a standard/sample is inserted, via the selection valve, in potassium nitrate as an electrolyte and water is used as a carrier. The zones are transported from the holding coil to the flow cell to monitor the difference in potential due to concentration cell behavior. The potential difference is then recorded as a peak. Peak height is proportional to logarithm of chloride concentration. The SI-LAV for chloride determination is very simple, fast, precise, accurate, automatic and economical. Applications to mineral drinking water and surface water have been made. The results agree with those of IC and titrimetric methods.  相似文献   

9.
A sequential injection analysis (SIA) system is proposed for the determination of iron (II). Fe(II) was determined by SIA based on the reaction between 1,10-phenanthroline and iron (II), yielding an orange–red colour complex with absorption maximum at 512 nm. The method involved aspiration of 187 μl sample/standard zone followed by a zone of a reagent solution containing 140 μl of 7.8 × 10−4 mol l−1 1,10-phenanthroline into a carrier stream to be stacked inside a holding coil and flow reversed through a reaction coil to a detector. The optimum condition was evaluated and the calibration curve is linear over a range of 0.25 to 5.0 mg l−1 of Fe(II) with detection limit of 18 μg l−1. A sample throughput of 40 h−1 was established. This technique is found to be simple, accurate, reproducible and sensitive. The proposed method was successfully applied for the determination of total iron as Fe(II) in pharmaceutical products (multi-vitamin tablets) and is especially useful for the determination of iron (II) in tablets with lower iron (II) contents. The results were found to be in good agreement with the results obtained by manual UV/Vis spectrophotometry and flame atomic absorption spectrometry (FAAS) and with claimed values by the manufacturers.  相似文献   

10.
A new separation method based on a novel reversed-phase sequential injection chromatography (SIC) technique was used for simultaneous determination of ambroxol hydrochloride and doxycycline in pharmaceutical preparations in this contribution.The coupling of short monolith with SIA system results in an implementation of separation step to until no-separation low-pressure method.A Chromolith® Flash RP-18e, 25-4.6 mm column (Merck, Germany) and a FIAlab® 3000 system (USA) with a six-port selection valve and 5 ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-water (20:90, v/v), pH 2.5 adjusted with 98% phosphoric acid, flow rate 0.48 ml min−1, UV detection was at 213 nm.The validation parameters have shown good results: linearity of determination for both compounds including internal standard (ethylparaben) >0.999; repeatability of determination (R.S.D.) in the range 0.5-5.4% at three different concentration levels, detection limits in the range 0.5-2.0 μg ml−1, and recovery from the pharmaceutical preparation in the range 99.3-99.9%. The chromatographic resolution between peak compounds was >5.0 and analysis time was <9 min under the optimal conditions. The method was found to be applicable for routine analysis of the active compounds ambroxol hydrochloride and doxycycline in various pharmaceutical preparations.  相似文献   

11.
A new sequential injection (SI) system with spectrophotometric detections has been developed for successive determination of protein and glucose. The protein assay is based on ion-association of protein with tetrabromophenolphthalein ethyl ester (TBPE) in the presence of Triton X-100 at pH 3.2. The blue product is monitored for absorbance at 607 nm. For glucose, hydrogen peroxide, generated by the oxidation of glucose in the presence of glucose oxidase immobilized on glass beads packed in a minicolumn, is monitored using iron-catalyzed oxidation reaction of p-anisidine to form a red colored product (520 nm). The SI procedure takes advantage in performing the protein assay during the incubation period for glucose oxidation. Linear ranges were up to 10 mg dL−1 human serum albumin (HSA) with a limit of detection (LOD) (3σ) of 0.3 mg dL−1, and up to 12.5 mg dL−1 glucose with LOD of 0.08 mg dL−1. R.S.D.s (n = 11) were 2.7% and 2.5% (for 1 mg dL−1 and 5 mg dL−1 HSA) and 1.4% (9 mg dL−1 glucose). Sample throughput for the whole assay of both protein and glucose is 6 h−1. The automated system has been demonstrated for the successive assay of protein and glucose in urine samples taken from diabetic disease patients, with good agreement with the other methods. This developed SI system is an alternative automation for screening for diabetic diagnosis.  相似文献   

12.
A sequential injection system with dual analytical line was developed and applied in the comparison of two different detection systems viz; a conventional spectrophotometer with a commercial flow cell, and a multi-reflective flow cell coupled with a photometric detector under the same experimental conditions. The study was based on the spectrophotometric determination of phosphate using the molybdenum-blue chemistry. The two alternative flow cells were compared in terms of their response to variation of sample salinity, susceptibility to interferences and to refractive index changes. The developed method was applied to the determination of phosphate in natural waters (estuarine, river, well and ground waters). The achieved detection limit (0.007 μM PO43−) is consistent with the requirement of the target water samples, and a wide quantification range (0.024–9.5 μM) was achieved using both detection systems.  相似文献   

13.
A spectrophotometric method is reported for the determination of bismuth in pharmaceutical products using sequential injection analysis. Methylthymol blue (MTB) was used as a color forming reagent and the absorbance of the Bi(III)-MTB complex was monitored at 548 nm. The various chemical and physical variables that affected the reaction were studied. A linear calibration graph was obtained in the range 0.0-75.0 mg l−1 Bi(III) at a sampling frequency of 72 h−1. The reagent consumption was considerably reduced compared to conventional flow injection systems, as only 150 μl of MTB were consumed per run. The precision was very satisfactory (sr=0.5%, at 50.0 mg l−1 Bi(III), n=12) and the limit of detection, cL, was 0.250 mg l−1. The developed method was applied successfully to the analysis of various pharmaceutical products containing Bi(III). The relative errors er, were <1.5% in all cases and were evaluated by comparison of the obtained results with those found using atomic absorption spectrometry as the reference method.  相似文献   

14.
A sequential injection method (SIA) for carbon speciation in inland bathing waters was developed comprising, in a single manifold, the determination of dissolved inorganic carbon (DIC), free dissolved carbon dioxide (CO2), total carbon (TC), dissolved organic carbon and alkalinity. The determination of DIC, CO2 and TC was based on colour change of bromothymol blue (660 nm) after CO2 diffusion through a hydrophobic membrane placed in a gas diffusion unit (GDU). For the DIC determination, an in-line acidification prior to the GDU was performed and, for the TC determination, an in-line UV photo-oxidation of the sample prior to GDU ensured the conversion of all carbon forms into CO2. Dissolved organic carbon (DOC) was determined by subtracting the obtained DIC value from the TC obtained value. The determination of alkalinity was based on the spectrophotometric measurement of bromocresol green colour change (611 nm) after reaction with acetic acid. The developed SIA method enabled the determination of DIC (0.24–3.5 mg C L−1), CO2 (1.0–10 mg C L−1), TC (0.50–4.0 mg C L−1) and alkalinity (1.2–4.7 mg C L−1 and 4.7–19 mg C L−1) with limits of detection of: 9.5 μg C L−1, 20 μg C L−1, 0.21 mg C L−1, 0.32 mg C L−1, respectively. The SIA system was effectively applied to inland bathing waters and the results showed good agreement with reference procedures.  相似文献   

15.
Two sequential injection titration systems with spectrophotometric detection have been developed. The first system for determination of ascorbic acid was based on redox reaction between ascorbic acid and permanganate in an acidic medium and lead to a decrease in color intensity of permanganate, monitored at 525 nm. A linear dependence of peak area obtained with ascorbic acid concentration up to 1200 mg l−1 was achieved. The relative standard deviation for 11 replicate determinations of 400 mg l−1 ascorbic acid was 2.9%. The second system, for acetic acid determination, was based on acid–base titration of acetic acid with sodium hydroxide using phenolphthalein as an indicator. The decrease in color intensity of the indicator was proportional to the acid content. A linear calibration graph in the range of 2–8% w v−1 of acetic acid with a relative standard deviation of 4.8% (5.0% w v−1 acetic acid, n=11) was obtained. Sample throughputs of 60 h−1 were achieved for both systems. The systems were successfully applied for the assays of ascorbic acid in vitamin C tablets and acetic acid content in vinegars, respectively.  相似文献   

16.
Polásek M  Jambor M 《Talanta》2002,58(6):1253-1261
Antibacterial drug trimethoprim [2,4-diamino-5-(3,4,5-trimethoxybenzyl)-pyrimidine] (I) was determined in pharmaceutical formulations by using a lab-made PC-controlled SIA analyser linked to conventional HPLC fluorimetric detector equipped with a chemiluminescence module. The chemical principle is the oxidation of I by KMnO(4) in acid medium; the reaction is accompanied by the emission of chemiluminescence, which is enhanced in the presence of hexametaphosphate (HMP). The optimum sequence and the flow parameters and concentrations and volumes of reagents aspirated optimised by a computer-aided simplex method were, 100 mul of 5 mM HMP, 40 mul of a test solution of I, 2 mul of 0.5 M H(2)SO(4) and 20 mul of 1 mM KMnO(4); the luminescing zone was pushed into the detector at a flow rate of 49 mul s(-1). The calibration graph relating the intensity of luminescence to concentration of I was parabolic (r=0.9994) in the range 0.5-100 mug ml(-1) of I with rectilinear part (r=0.9999) in the range 20-100 mug ml(-1) of I; the limit of detection was 0.1 mug ml(-1) of I. The method was used for the assay of Triprim(R) tablets (with nominal content 100 or 200 mg of I) for the active substance as well as for content uniformity tests; the R.S.D. values did not exceed 1% (n=5). The SIA results did not show statistical difference from those obtained by pharmacopoeial acidimetric titration in non-aqueous medium; the excipients such as microcrystalline cellulose, maze starch, povidone, talc, magnesium stearate and gelatin did not interfere.  相似文献   

17.
Oms MT  Cerdà A  Cerdà V 《Talanta》2003,59(2):319-326
An automatic method for the determination of total nitrogen in wastewater by sequential injection analysis and mineralization with UV radiation has been developed. The method is based on the mineralization of the samples with sodium persulphate in basic medium under UV radiation. Small volumes of sample and reagents are firstly aspirated into a single channel and then propelled by flow reversal to the UV reactor and then to the detector. The organic and inorganic nitrogen compounds are oxidized to nitrate that is then measured at 226 nm. The sequential injection procedure has been optimized and the factors affecting the efficiency of the oxidation have been studied with a number of test substances with different chemical structures and properties. Solutions in the concentration range 1-56 g l−1 of nitrogen can be analyzed with the described procedure. The sample rate is of 30-40 samples h−1. The LOD is 0.6 mg l−1 N and the reproducibility is 1.8% (28 mg l−1 N). Organic carbon in the form of glucose was added to a number of test solutions to study the potential interference of organic matter.The method was compared with the Kjeldahl digestion method by analyzing 15 wastewater samples with both methods. The nitrate and nitrite content of the non-oxidized samples were subtracted from the corresponding nitrogen content determined after photo-oxidation and the value compared with the Kjeldahl nitrogen content.  相似文献   

18.
The performance of sequential injection (SI) systems has often been criticized for its low sampling frequency. The present work describes a SI system where an injection valve and an additional pump were incorporated to enhance sample throughput rate. The proposed system was applied to the enzymatic determination of glycerol and ethanol in wines, using spectrophotometric detection and immobilized glycerol and alcohol dehydrogenases. The method proposed was applied to the determination of ethanol between 0.10 and 0.50% (v/v) and glycerol between 0.03 and 0.30 g l−1. These ranges were appropriate for determination in table and port wines, since samples were diluted 50 times before introduction into the system. The results obtained from 15 wine samples were statistically comparable to those obtained by the reference methods, with good repeatability (R.S.D.<3.4%, n=10). The sampling rate was 22.5 h−1, corresponding to 45 determinations per hour. This way, the time required for each determination was decreased by 30% when compared to a conventional SI system.  相似文献   

19.
A novel automatic sequential injection (SI) single-drop micro-extraction (SDME) system is proposed as versatile approach for on-line metal preconcentration and/or separation. Coupled to electrothermal atomic absorption spectrometry (ETAAS) the potentials of this SI scheme are demonstrated for trace cadmium determination in water samples. A non-charged complex of cadmium with ammonium diethyldithiophosphate (DDPA) was produced and extracted on-line into a 60 μL micro-drop of di-isobutyl ketone (DIBK). The extraction procedure was performed into a newly designed flow-through extraction cell coupled on a sequential injection manifold. As the complex Cd(II)-DDPA flowed continuously around the micro-droplet, the analyte was extracting into the solvent micro-drop. All the critical parameters were optimized and offered good performance characteristics and high preconcentration ratios. For 600 s micro-extraction time, the enhancement factor was 10 and the sampling frequency was 6 h−1. The detection limit was 0.01 μg L−1 and the precision (RSD at 0.1 μg L−1 of cadmium) was 3.9%. The proposed method was evaluated by analyzing certified reference material.  相似文献   

20.
In this work, a novel flow-through solid-phase based chemiluminescence (CL) optical sensor is described for the trace determination of orthophosphate in waters exploiting the multisyringe flow injection analysis (MSFIA) concept with multicommutation. The proposed time-based injection flow system relies upon the in-line derivatisation of the analyte with ammonium molybdate in the presence of vanadate, and the transient immobilisation of the resulting heteropolyacid in a N-vinylpyrrolidone/divinylbenzene copolymer packed spiral shape flow-through cell located in front of the window of a photomultiplier tube. The simultaneous injection of well-defined slugs of luminol in alkaline medium and methanol solution towards the packed reactor is afterwards performed by proper switching of the solenoid valves. Then, the light emission from the luminol oxidation by the oxidant species retained onto the sorbent material is readily detected. At the same time, the generated molybdenum-blue compound is eluted by the minute amount of injected methanol, rendering the system prepared for a new measuring cycle. Therefore, the devised sensor enables the integration of the solid-phase CL reaction with elution and detection of the emitted light without the typical drawbacks of the molybdenum-blue based spectrophotometric procedures regarding the excess of molybdate anion, which causes high background signals due to its self-reduction. The noteworthy features of the developed CL-MSFIA system are the feasibility to accommodate reactions with different pH requirements and the ability to determine trace levels of orthophosphate in high silicate content samples (Si/P ratios up to 500). Under the optimised conditions, a dynamic linear range from 5 to 50 μg P l−1 for a 1.8 ml sample, repeatability better than 3.0% and a quantification limit of 4 μg P l−1 were attained. The flowing stream system handles 11 analysis h−1 and has been successfully applied to the determination of trace levels of orthophosphate in environmental samples such as mineral, ground, tap and pond waters as well as samples from a water-steam cycle of an incineration plant. The t-test comparison of the means for the developed optical sensor and the molybdenum-blue spectrophotometric APHA/AWWA/WPCF reference method revealed that there is no evidence of significant differences between the obtained results at the 95% confidence level.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号