1.
Simultaneous determination of As and Sb by hydride generation atomic fluorescence spectrometry was developed with the dielectric barrier discharge plasma as the hydride atomizer. The low-temperature and atmospheric-pressure micro-plasma was generated in a quartz cylindrical configuration device, which was constructed by an axial internal electrode and an outer electrode surrounding outside of the tube. The optimization of the atomizer construction and parameters for hydride generation and fluorescence detection systems were carried out. Under the optimized conditions, the detection limits for As and Sb were 0.04 and 0.05 μg L−1, respectively. In addition, the applicability of the present method was confirmed by the detection of As and Sb in reference materials of quartz sandstone (GBW07106) and argillaceous limestone (GBW07108). The present work provided a new approach to exploit the miniaturized hydride generation dielectric barrier discharge atomic fluorescence spectrometry system for simultaneous multi-element determination.  相似文献   

2.
A new method was developed for simultaneous determination of trace arsenic and antimony in Chinese herbal medicines by hydride generation-double channel atomic fluorescence spectrometry with a Soxhlet extraction system and an n-octanol-water extraction system, respectively. The effects of analytical conditions on the fluorescence intensity were investigated and optimized. A water-dissolving and methanol-water-dissolving capability were compared. The contents of different species in five Chinese herbal medicines and their decoctions were analyzed. The concentration ratios of n-octanol-soluble As or Sb to water-soluble As or Sb were related to the kinds of medicine and the acidity of the decoction. Soxhlet extraction was found to be an effective method for plants pretreatment for determination of arsenic and antimony species in Chinese herbs; the interferences of coexisting ions were evaluated. The proposed method has the advantages of simple operation, high sensitivity and high speed, with 3σ detection limits of 0.094 μg g−1 for As(III), 0.056 μg g−1 for total As, 0.063 μg g−1 for Sb(III) and 0.019 μg g−1 for total Sb in a 1.0 g of the sample.  相似文献   

3.
This paper describes a method for the simultaneous determination of As(III), Sb(III) and Se(IV) by combining hydride generation and gas phase molecular absorption spectrometry. A system for continuous hydride generation has been designed and developed, based on the use of a double process of gas-liquid separation, and optimal compromise operation conditions for the three compounds have been found. After generation, the hydrides are collected in a liquid nitrogen cryogenic trap, and then evaporated and driven to the flow cell of a diode array spectrophotometer, in which the transient signals over the 190–250 nm wavelength interval are measured. Under the recommended conditions (sample flow: 35 ml min−1, 0.5 M HCl; reductor flow: 4 ml min−1 of 4% NaBH4, solution) linear response ranges above 50 μg 1−1 for As(III), 30 μg 1−1 for Sb(III) and 200 μg 1−1 for Se(IV) are obtained with detection limits of 22 μg 1−1, 15 μg 1−1 and 65 μg 1−1, respectively. Multiwavelength linear regression equations were used for the simultaneous determination of the three elements in different synthetic samples, with good precision and accuracy and to study simultaneously the interference from different chemical species for the three compounds. Results were similar to those obtained by other techniques using hydride generation.  相似文献   

4.
建立了双道氢化物发生-原子荧光光谱法同时测定核电用钢中痕量砷和锑的新方法。用王水溶解样品,以2.0 g/L L-半胱氨酸溶液作为预还原剂,在低酸度条件下实现对砷、锑的预还原。用20 g/L硼氢化钾溶液作为还原剂,氢化物发生反应在0.5 mol/L乙酸介质中进行。砷、锑的质量浓度在40μg/L范围与相应的荧光强度呈线性关系,方法的检出限(3s/k)分别为0.032μg/L和0.022μg/L。应用此方法同时测定了核电用钢及不锈钢标准样品中的砷锑含量,并与电感耦合等离子体原子发射光谱法的分析结果作了对比,测定值与标准样品的标准值相符,结果的相对标准偏差(n=8)均小于5.0%。  相似文献   

5.
Studies of the decomposition rate of the reducing agent sodium tetrahydroborate in alkaline and acidic media and of the reaction rate of the formation of the hydrides under the usual analytical conditions are described. The stripping of the hydrides with different lengths of the stripping coil, with different amounts of hydrogen in the carrier gas and with sodium hydroxide added during and after the stripping process are discussed. Some evidence for the existence of an intermediate during the decomposition reaction of the sodium tetrahydroborate is given. The role of temperature, hydrogen and oxygen during the atomization of the hydrides in an electrically heated quartz cuvette is discussed. Under certain conditions, antimony atoms form dimers or elemental antimony precipitates in the heated cuvette.  相似文献   

6.
Four analytical approaches, based on different physical principles, for the determination of antimony (Sb) and arsenic (As) in ancient peat samples were critically evaluated: (a) open vessel digestion/hydride generation-atomic absorption spectrometry (HG-AAS), (b) closed-pressurized digestion in a microwave oven followed by sector field-inductively coupled plasma-mass spectrometry (SF-ICP-MS), (c) digestion in a microwave autoclave and subsequent quadrupole-inductively coupled plasma-mass spectrometry (Q-ICP-MS) measurements and (d) instrumental neutron activation analysis (INAA). The quality control scheme applied, always included the use of adequate plant reference materials to ensure the accuracy and precision of the analytical procedures. Additionally, two internal peat reference materials were analyzed using all four analytical approaches, generally showing good agreement for both elements. Method detection limits for As and Sb provided by all procedures were approximately 5 and 2 ng g−1 which is sufficiently low for the reliable quantification of both elements in ancient, pre-anthropogenic peat samples. A comparison of As and Sb concentrations in a set of peat samples determined by INAA, HG-AAS and SF-ICP-MS revealed that INAA underestimated the values in a systematic manner, whereas HG-AAS and SF-ICP-MS data agreed very well. Best precision of the results was obtained by analytical procedures involving HG-AAS or Q-ICP-MS and varied from 3.6 to 4.3% and 7.1 to 7.5% for As (at about 0.5 μg g−1) and Sb (at about 0.1 μg g−1), respectively. The highest sample throughput (40 samples per run accomplished in 2 h) combined with low risk of sample contamination could be realized in the high-pressure microwave autoclave. The amount of sample required by all approaches was 200 mg, except for INAA which needed at least 25 times more sample mass to achieve comparable detection limits. For the quantification of As and Sb, inductively coupled plasma-mass spectrometry (ICP-MS) was preferred over INAA and HG-AAS, mainly because (a) less sample is needed and (b) As and Sb can be determined simultaneously. In addition, ICP-MS offers the possibility to measure concurrently a wide range of other elements which also are of environmental interest.  相似文献   

7.
A new method was developed for the simultaneous speciation of inorganic arsenic and antimony in water by on-line solid-phase extraction coupled with hydride generation-double channel atomic fluorescence spectrometry (HG-DC-AFS). The speciation scheme involved the on-line formation and retention of the ammonium pyrrolidine dithiocarbamate complexes of As(III) and Sb(III) on a single-walled carbon nanotubes packed micro-column, followed by on-line elution and simultaneous detection of As(III) and Sb(III) by HG-DC-AFS; the total As and total Sb were determined by the same protocol after As(V) and Sb(V) were reduced by thiourea, with As(V) and Sb(V) concentrations obtained by subtraction. Various experimental parameters affecting the on-line solid-phase extraction and determination of the analytes species have been investigated in detail. With 180 s preconcentration time, the enrichment factors were found to be 25.4 for As(III) and 24.6 for Sb(III), with the limits of detection (LODs) of 3.8 ng L− 1 for As(III) and 2.1 ng L− 1 for Sb(III). The precisions (RSD) for five replicate measurements of 0.5 μg L−1 of As(III) and 0.2 μg L−1 of Sb(III) were 4.2 and 4.8%, respectively. The developed method was validated by the analysis of standard reference materials (NIST SRM 1640a), and was applied to the speciation of inorganic As and Sb in natural water samples.  相似文献   

8.
The long-term uptake and distribution of arsenic compounds by hydroponically cultivated White mustard (Sinapis alba) was investigated with a special emphasis on controlling the stability of the arsenic compounds in nutrient solution during the experiment. It was concluded that arsenites are rapidly oxidised to arsenates during the 7-day cultivation of White mustard. The presence of plant roots increases the oxidation rate of arsenites. Dimethylarsinic acid (DMA) and arsenates remain stable during the exposition, while monomethylarsonic acid (MMA) is partially demethylated. When the nutrient solution containing arsenites is exchanged daily, the distribution of arsenic in White mustard is significantly different (translocation factor—TF—is 70 times higher) in comparison to the experiment without exchange of the medium. Speciation analysis of arsenic in plant tissues and in nutrient solutions was performed by high performance liquid chromatography with inductively coupled plasma-mass spectrometry (HPLC ICP-MS). The results obtained unquestionably illustrated that the uncontrolled conditions of hydroponic plant cultivation may be a source of misinterpretation of all the obtained data. Additionally, the synthesis of phytochelatins in plants exposed to different arsenic compounds was investigated. Phytochelatins were identified in tissues of plants exposed to arsenites and arsenates, and their presence was correlated with high arsenite content. Phytochelatin synthesis was not indicated in plants grown in the presence of MMA and DMA.  相似文献   

9.
A rapid, high sensitivity method has been developed for the determination of As(III), As(V), Sb(III) and Sb(V) in milk samples by using hydride generation atomic fluorescence spectrometry. The method is based on the leaching of As and Sb from milk through the sonication of samples with aqua regia followed by direct determination of the corresponding hydrides both before and after reduction with KI. It was confirmed by recovery experiments on spiked commercially available samples that neither the reduced nor the oxidized forms of the elements under study or mixtures of the two oxidation states were modified by the room temperature sample treatment with aqua regia. The methodologies developed provided 3σ limit of detection values of 8.1, 10.3, 5.4 and 7.7 ng l−1 for As(III), As(V), Sb(III) and Sb(V) in the diluted samples. Average relative standard deviation values of 5.7, 5.5, 8.2 and 4.7% were found for determination of As(III), As(V), Sb(III) and Sb(V) in commercially available samples of different composition and origin containing from 3.5 to 13.6 ng g−1 total As and from 4.9 to 11.8 ng g−1 total Sb, it being confirmed that As(V) and Sb(V) are the main species present in the samples analyzed (62±5 and 73±5%, respectively). The time required to determine As and Sb species in milk involves 10 min sonication and 30 min prereduction but these steps can be carried out for several sample simultaneously. Additionally the fluorescence measurement step involves less than 20 min for three replicates of all the four measurements required. So, in less than 2 h it is possible to determine the content of As(III), As(V), Sb(III) and Sb(V) in four samples.  相似文献   

10.
研究了氢化物发生原子吸收法测定包头矿中痕量砷、锑、铋的分析方法,试验确立了反应条件,建立了以KI、抗坏血酸、硫脲为还原体系,消除试样中共存元素的干扰,利用KMnO4消除锑对砷的干扰.砷、锑、铋的检出限可分别达到:0.15,0.28,0.15 ng/mL.方法已用于包头矿分析.  相似文献   

11.
研究了氢化物发生-原子荧光光谱法测定高纯铟中微量As、Sb元素的条件,选择了适宜的反应条件以及仪器的最佳工作条件,考察了铟基体对被测元素的干扰,采用基体匹配的方法消除干扰,建立了氢化物发生-原子荧光光谱法测定高纯铟中微量的As、Sb的分析方法。As、Sb的检出限分别为0.18和0.28 ng/mL,测定下限为1.2×10-5和1.9×10-5,相对标准偏差分别为1.9%和1.7%,回收率为97.4%和103%,适用于5~6 N高纯铟中微量As、Sb的测定。  相似文献   

12.
To study the effect of the environmental pollution in exposed population, human hair samples of residents were collected from two typical antimony mines (Xikuangshan antimony mine and Qinglong antimony mine, Southwest China) and one non-mining city (Guiyang, Southwest China), and the concentrations of arsenic, antimony and bismuth in these samples were analyzed by hydride generation-atomic fluorescence spectrometry. Arsenic concentrations for Xikuangshan, Qinglong, and Guiyang ranged 0.236-48.4 (mean 4.21), 0.130-16.1 (mean 2.96), and 0.104-0.796 (mean 0.280) μg/g, respectively. Antimony concentrations for Xikuangshan, Qinglong, and Guiyang ranged 0.250-82.4 (mean 15.9), 0.060-45.9 (mean 5.15), and 0.065-2.87 (mean 0.532) μg/g, respectively. Bismuth contents were found to be greater than the limit of detection (LOD > 0.016 μg/g) in all the human hair samples collected from residents from Qinglong antimony mine, 95.5% samples from Xikuangshan mine and only 22.7% samples from Guiyang. There were no significant differences in both arsenic and antimony concentrations between hair samples from male and female individuals in the same area (P > 0.05). Arsenic and bismuth were mainly present in samples from children (5-9 years) and adults aged 41-51 years. Relatively high antimony contents (≥ 3 μg/g) were detected mainly in samples from children and adults aged ≥ 41 years. Significant correlation was found between the concentrations of arsenic and antimony in the human hair samples (r = 0.523, P < 0.05). The results indicate that arsenic and antimony in antimony mining area may significantly affect human health.  相似文献   

13.
A separation method utilizing a synthetic zeolite (mordenite) was developed in order to eliminate the gas phase interference of Sb(III) on As(III) during quartz furnace hydride generation atomic absorption spectrometric (HGAAS) determination. The efficiency of the proposed separation method in the reduction of suppression effects of transition metal ions on As(III) signal was also investigated. Among the volatile hydride-forming elements and their different oxidation states tested (Sb(III), Sb(V), Se(IV), Se(VI), Te(IV), and Te(VI)), only Sb(III) was found to have a signal depression effect even at low (μg l−1) concentrations under the experimental conditions employed. It has been shown that mordenite adsorbs Sb(III) quantitatively, even at a concentration of 1000 μg l−1, at pHs greater than two, and also, it reduces the initial concentrations of the transition metal ions to lower levels which can be tolerated in many studies. The adsorption of Sb(III) on mordenite follows the Freundlich isotherm and is endothermic in nature.  相似文献   

14.
Hydride generation inductively coupled plasma optical emission spectrometry (HG-ICP-OES) was used in the determination of As and Sb concentrations in fly ash samples. The effect of sample pre-treatment reagents and measurement parameters used for hydride generation was evaluated. Due to memory effects observed, the appropriate read delay time was adjusted to 60 s resulting in RSDs 0.6% and 2.3% for As and Sb, respectively. The most suitable volumes of pre-reduction reagents for 10 mL of sample were 4 mL of KI/ascorbic acid (5%) and 6 mL of HCl (conc.). The determination of Sb was significantly interfered by HF, but the interference could be eliminated by adding 2 mL of saturated boric acid and heating the samples to 60 °C at least 45 min. The accuracy of the method was studied by analyses of SRM 1633b and two fly ash samples with the recovery test of added As and Sb. As high a recovery as 96% for SRM 1633b was reached for As using 193.696 nm with two-step ultrasound-assisted digestion. A recovery rate of 103% was obtained for Sb using 217.582 nm and the pre-reduction method with the addition of 2 mL of saturated boric acid and heating. The quantification limits for the determination of As and Sb in the fly ash samples using two-step ultrasound-assisted digestion followed with HG-ICP-OES were 0.89 and 1.37 mg kg−1, respectively.  相似文献   

15.
氢化物发生-原子荧光光谱法测定高纯锌中砷、锑、铋   总被引:1,自引:0,他引:1  
提出了以硫脲-抗坏血酸-盐酸羟胺作为混合还原掩蔽剂,氢化物发生-原子荧光光谱法(HG-AFS)测定高纯锌中砷、锑、铋的方法。考察了测定的最佳条件、共存元素对测定的影响及方法的准确度和精密度。方法适用于高纯锌中0.00002%~0.01%砷、锑、铋的测定。  相似文献   

16.
A highly sensitive procedure has been developed for total arsenic and antimony determination in milk samples by hydride generation atomic fluorescence spectrometry after microwave-assisted sample digestion. The discrete introduction of 2 ml of digested sample in the automated continuous flow hydride generation system allows us to reduce drastically the sample and HCl consume and to determine several elements from a same sample digestion. The method provides detection limits of 0.006 and 0.003 ng ml−1, a sensitivity of 2390 and 2840 fluorescence units per ng ml−1 for As and Sb respectively, and average relative standard deviation of 2.3% for As and 4.8% for Sb. The analysis of cow milk samples, obtained from the Spanish market evidenced the presence of As at concentration levels from 3.4 to 11.6 ng g−1 and Sb levels from 3.5 to 11.9 ng g−1, thus in a proportion near to 1:1, which is in contrast with the 10:1 natural ratio between As and Sb and could evidence the effect of the introduction of new alloys and polymer materials in the industrial process of milk. The method was validated by the comparison of data found for commercial samples by using the proposed procedure and reference methods based on dry-ashing and AFS, and microwave-assisted digestion and inductively coupled plasma mass spectrometry determination.  相似文献   

17.
采用化学蒸气发生-四通道原子荧光光谱法测定了高纯金中的痕量砷、锑、铋和碲。用乙酸乙脂萃取分离金,水相还原后采用化学蒸气发生-四通道原子荧光光谱法测定高纯金中的痕量砷、锑、铋和碲。在最佳条件下,方法对As,Sb,Bi,Te的检出限分别为0.04,0.05,0.04,0.03 ng/mL(3σ);测定精密度分别为0.98,0.89,0.94,0.99%(对10 ng/mL As,Sb,Bi和Te混合标准,n=7)。方法对实际样品中的As,Sb,Bi,Te进行了同时测定,测定结果与标准方法无明显差异,各元素的加标回收率为95%~105%。  相似文献   

18.
Silver nanoparticles (AgNPs) were proposed as a new chemical modifier for the elimination of interferences when determining arsenic and antimony in aqueous NaCl or Na2SO4 solutions and in sea-water by electrothermal atomic absorption spectrometry. For this purpose, the AgNPs were prepared simply by reducing silver nitrate with sodium citrate. The effects of pyrolysis and atomization temperatures and the amounts of interferents and modifiers on the sensitivities of these elements were investigated. In the presence of the proposed modifier, a pyrolysis temperature of at least 1100 °C for arsenic and 900 °C for antimony could be applied without the loss of analytes, and the interferences were greatly reduced to allow for interference-free determination. The detection limits (N = 10, 3σ) for arsenic and antimony were 0.022 ng and 0.046 ng, respectively. AgNPs are cheaper and more available compared to many other modifiers. No background was detected, and the blank values were negligible.  相似文献   

19.
This paper reports the determination of arsenic and antimony in naphtha by employing electrothermal atomic absorption spectrometry (ETAAS) as the analytical technique. In order to promote the direct determination of the analytes in the very volatile naphtha, the formation of a microemulsion with different surfactants (Triton X-100 and Brij-35) and different chemical modification strategies were tested. The results indicated that Triton X-100 is the best emulsification agent for naphtha in both As and Sb determination when it is employed at a concentration of 1% w/v in the microemulsion. Under these conditions, the microemulsion was stabile for at least 2 h. By using Brij-35 it was possible to achieve good stability only in the first 15 min. Among all chemical modification approaches investigated (Ir permanent modifier, W-Ir permanent modifier, and Pd modifier), the Ir permanent modifier provided better sensitivity for both analytes and allowed a higher pyrolysis temperature, which decreased the background signals at lower levels. Under the best conditions established in this work, an RSD of 4.6% (20 g L–1) and a detection limit of 2.7 g L–1 were observed for arsenic. For antimony, an RSD of 4.0% (20 g L–1) and a detection limit of 2.5 g L–1 were obtained. The accuracy of the procedure was assessed by analyzing spiked samples of naphtha from different origins.  相似文献   

20.
To study the characteristics of antimony (Sb) bioaccumulation under high Sb background values, aquatic, amphibious and terrestrial biological samples were collected in the vicinity of the Xikuangshan (XKS) Sb mine area in China. Hydride generation-atomic fluorescence (HG-AFS) analysis showed that Sb concentrations in terrestrial invertebrates (average 30,400 μg kg− 1 dry wt.) were higher than those in aquatic (average 5200 μg kg− 1 dry wt.) and amphibian (average 2300 μg kg− 1 dry wt.) biological samples. Within 1 km distance of the XKS Sb mine area, grasshoppers (Acrida chinensis) and earthworms (Pheretima aspergillum) had the highest Sb amounts of 17,300 ±3200 and 43,600 ± 47,700 μg kg− 1 dry wt., respectively. No Sb biomagnifications were observed. The bioavailability of Sb was found to be lower than those of As and Hg. A preliminary conclusion is that antagonistic effects exist between Sb and Hg accumulation in biological samples from aquatic environments. Our study is the first to report such antagonistic effects between Sb and Hg. If this deduction proves to be correct, it should be taken into consideration in assessing human health risks, especially when Sb and Hg concentrations in the aquatic environments are high.  相似文献   