共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
鲁米诺-铁氰化钾化学发光体系测定甲基多巴 总被引:1,自引:0,他引:1
本文研究发现,铁氰化钾在碱性条件能氧化鲁米诺产生微弱的化学发光,而甲基多巴能大大增强该体系的发光强度.基于此,结合流动注射技术,建立起一种直接测定甲基多巴的流动注射化学发光新方法.该方法的检出限为5.7×10-10g/mL,甲基多巴浓度在1.0×10-9~1.0×10-7g/mL范围内与发光强度呈良好的线性关系.对1.0×10-9g/mL的甲基多巴平行测定11次,其相对标准偏差为2.3%.利用该方法对甲基多巴片剂含量的测定,结果令人满意. 相似文献
3.
流动注射化学发光法测定中药材中没食子酸 总被引:3,自引:0,他引:3
建立快速简便的流动注射化学发光分析法,用于中药材中没食子酸含量的测定.利用酸性介质中Fe3+-H2O2体系生成羟基自由基氧化没食子酸产生微弱的化学发光,用罗丹明6G来增敏化学发光.研究了影响化学发光的各种因素,探讨了可能的机理.结果表明,0.18 mol/L HCl,0.04 mol/L FeCl3,1.0 mol/L H2O2与1.0×10-4 mol/L罗丹明6G溶液组成最优的化学发光体系,没食子酸浓度在1.0×10-5~1.0×10-2 g/L和0.01~1.0 g/L范围内与化学发光强度呈很好的线性关系,r分别为0.9984和0.9947,检出限为3.0×10-6 g/L.对1.0×10-4 g/L没食子酸平行测定11次的相对标准偏差为3.8%.利用本方法成功地测定了中药材诃子和没食子中的没食子酸含量. 相似文献
4.
5.
6.
A simple, sensitive and inexpensive flow injection chemiluminescence method for the determination of azathioprine had been discovered. It was based on the fact that the weak chemiluminescent reaction of cerium(IV) with azathioprine in acidic medium, which was enhanced by the addition of rhodamine 6G. A lot of optimized experimental conditions had been studied in detail. The CL intensity was linearly related to the concentration of azathioprine in the range of 0.1–10.0 μM and the detection limit was 45.0 nM (3σ). The relative standard deviation (RSD) for the technique was 2.1% (n = 11). The method had high selectivity, sensitivity and good repeatability. The proposed method had been triumphantly applied to the determination of azathioprine in human fluids and pharmaceutical formulation with satisfactory results. 相似文献
7.
8.
流动注射化学发光法测定没食子酸 总被引:4,自引:0,他引:4
基于在碱性介质中,没食子酸(Gallicacid)被过氧化氢氧化能产生化学发光,而甲醛对该体系的化学发光有较强增敏作用,据此建立了流动注射化学发光法测定没食子酸的新方法。该法简单、快速、线性范围较宽。本法测定没食子酸的线性范围为2.0×10-6~2.0×10-4g/mL,检出限达5.8×10-7g/mL,采样频率为120个/小时。对4.0×10-5g/mL没食子酸溶液连续11次测定的相对标准偏差为2.52%。该方法已成功地用于橄榄中没食子酸含量的测定。 相似文献
9.
10.
ChemiluminescenceDeterminationof6-MercaptopurineinPharmaceuticalsHEZhi-ke,LIUXing-lian,LUOQing-yao,YUXi-maoandZENGYun'e(Depar... 相似文献
11.
12.
罗丹明6G荧光猝灭法测定微量硅的研究 总被引:4,自引:0,他引:4
研究了酸性介质中,在非离子表面活性剂PVA存在下,硅钼杂多酸与罗丹明6G形成离子缔合物最佳条件,本法灵敏度高,选择性好,操作简便,对钢合金、钢样中硅进行测定,结果满意。 相似文献
13.
Wang JP Li NB Luo HQ 《Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy》2008,71(1):204-208
A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with rhodamine 6G and ceric sulfate in sulphuric acid medium. Strong chemiluminescence signal was observed when ferulic acid was injected into the acidic ceric sulfate solution in a flow-cell. The present method allowed the determination of ferulic acid in the concentration range of 8.0x10(-6) to 1.0x10(-4)moll(-1) and the detection limit for ferulic acid was 8.7x10(-9)moll(-1). The relative standard deviation was 2.4% for 10 replicate analyses of 1.0x10(-5)moll(-1) ferulic acid. The proposed method was applied to the determination of ferulic acid in Taita Beauty Essence samples with satisfactory results. 相似文献
14.
流动注射-化学发光法测定乌拉地尔 总被引:2,自引:0,他引:2
乌拉地尔 (Urapidil)即 6 - { [3 - [4- (o-甲氧苯基 ) - 1 -哌嗪 ]-丙基 ]-氨基 } - 1 ,3 -二甲基脲嘧啶 ,又名乌Scheme 1 The chemical structure of Urapidil拉尔碱或压宁定 ,为苯哌嗪取代的脲嘧啶衍生物 ,其结构见 Scheme 1 .乌拉地尔是一种高选择性的α受体阻滞剂 ,能使 相似文献
15.
流动注射—化学发光法测定维生素B6 总被引:6,自引:0,他引:6
在酸性介质中,维生素B6与高锰酸钾发生氧化还原反应并产生化学发光信号,连二亚硫酸钠的存在能使这一反应的化学发光强度大大增强。 相似文献
16.
17.
流动注射化学发光法测定青霉素G钾 总被引:1,自引:0,他引:1
在甲醛的存在下,酸性KMnO4与青霉素G钾能够产生很强的化学发光,从而建立了KMnO4-甲醛-青霉素G钾化学发光体系来测定青霉素G钾.青霉素G钾的测定线性范围为2.0×10-7~1.0×10-5 g/mL,方法的检出限为1.4×10-7 g/mL,对4.0×10-7 g/mL的青霉素G钾进行11次平行测定,相对标准偏差为1.0%,用此法测定青霉素G钾取得了较好的结果. 相似文献
18.
19.
研究发现,铁氰化钾在碱性条件下能氧化鲁米诺产生微弱的化学发光,硫酸特布他林能大大增强该发光强度。在此基础上,结合流动注射技术,建立了一种直接测定硫酸特布他林的流动注射化学发光分析法。该方法的检出限为5.7×10-10g/mL,硫酸特布他林质量浓度在1.0×10-9~1.0×10-7g/mL范围内与发光强度呈良好的线性关系,相对标准偏差为3.3%(硫酸特布他林1.0×10-8g/mL,n=11)。利用该方法对特布他林片剂和针剂含量的测定,结果令人满意。 相似文献
20.
罗丹明6G与核酸作用的共振光散射光谱及其分析应用 总被引:6,自引:0,他引:6
研究了罗丹明6G(Rh6G)与核酸(ctDNA和yRNA)作用的共振光散光谱(RLS)特征,基于RLS的增强,建立了一种测定核酸的新方法,考察了各种影响因素,在优化条件下确定了RLS强度与ctDNA和yRNA浓度之间的关系,相应的线性范围分别为0.05-37.0μg.mL^-1、0.1-10.0μg.mL^-1,检出限分别为3.0ng.mL^-1和9.5ng.mL^-1。四种合成样品五次平行测定结果的相对标准偏差(RSD)范围为2.0%-3.0%。 相似文献