首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two reference materials, at relatively low and high concentrations (GBW08404 and GBW08405), for analysis of the mass fractions of Cd, Cr, Hg and Pb in polypropylene were developed. The reference materials were prepared by doping blank polypropylene base material with Cd, Cr, Hg and Pb in the form of oxides, salts or pigments. Homogeneity and stability studies were performed by inductively coupled plasma mass spectrometry. The certification of the four analytes was carried out by isotope-dilution mass spectrometry (IDMS) with microwave-assisted digestion. Combined uncertainties were calculated from the IDMS uncertainty evaluation budget and the uncertainty of the homogeneity. The mass fractions of Cd, Cr, Hg and Pb of the two certified reference materials (CRMs) were from 8 to 1,000 mg kg−1. The two samples were also used in an interlaboratory comparison scheme in which National Institute of Metrology, China, National Metrological Institute of Japan and Korea Research Institute of Standards and Science participated. The agreement of the comparison results proved that the certification procedure of the CRMs is valid and that the certified values of Cd, Cr, Hg and Pb are accurate and reliable.  相似文献   

2.
Matrix certified reference materials (CRMs) are playing an increasingly important role in environmental monitoring in Japan. The National Metrology Institute of Japan (NMIJ)/National Institute of Advanced Industrial Science and Technology (AIST) has been developing matrix CRMs for environmental monitoring since 2001, and has issued nine kinds of CRMs as NMIJ CRMs. The development of the CRMs was conducted in NMIJ in cooperation with candidate material producers. The isotope dilution mass spectrometry (IDMS) was principally adopted to give reliable certified values. Meanwhile, two or more analytical methods, whose levels of accuracy were well evaluated, were applied to avoid any possible analytical bias. Two typical certification processes, the certification of river water CRMs for trace element analysis and that of marine sediment CRMs for PCB and organochlorine pesticide analysis, are outlined as examples. Presented at -- “BERM-10” -- April 2006, Charleston, SC, USA.  相似文献   

3.
Metrology in chemistry has its own features, which distinguish it from classical metrology: due to the lack of primary methods applicable in routine measurements, metrological traceability of measurement results can be achieved by using in a proper way suitable certified reference materials (CRMs), which can assure a direct relation to a reference. This article deals with the activity of the Italian National Institute of Metrological Research (Istituto Nazionale di Ricerca Metrologica—I.N.Ri.M.) on the analysis of various polychlorinated biphenyls congeners in organic solution by means of gas-chromatography coupled with mass spectrometry. The metrological traceability approach in the quantification step is pursued via calibration solutions prepared by gravimetrically diluting a CRM. The uncertainty for the calibration solutions was evaluated taking into account all the relevant contributions.  相似文献   

4.
A certified matrix reference material (CRM) for the measurement of benzene in ambient air has been developed at Laboratoire National de Métrologie et d’Essais. The production of these CRMs was conducted using a gravimetric method fully traceable to the International System of Units. The CRMs were prepared by sampling an accurate mass of a gaseous primary reference material of benzene, using a high-precision laminar flowmeter and a mass flow controller, with a PerkinElmer sampler filled with Carbopack™ X sorbent. The relative standard deviations obtained for the preparation of a batch of 20 tubes loaded with 500 ng of benzene were below 0.2%. Each CRM is considered independent from the others and with its own certified value and an expanded uncertainty estimated to be within 0.5%, lower than the uncertainties of benzene CRMs already available worldwide. The stability of these materials was also established up to 12 months. These CRMs were implemented during proficiency testing, to evaluate the analytical performances of seven French laboratories involved in benzene air monitoring.  相似文献   

5.
This study simulated the transport and storage conditions of ethanol in water certified reference material (CRM) produced by the Chemical Metrology Division of Inmetro—DQUIM with the purpose of estimating the measurement uncertainty related to stability. The short-term stability study was performed on five different mass fractions (w) in terms of mg ethanol/g solution of the ethanol in water CRM. The nominal values are w = 0.5, 0.9, 1.1, 3.8 and 4.6 mg/g, at temperatures of 4 and 60 °C. On the other hand, the long-term stability study was developed on four different mass fractions (nominal values): w = 0.5, 0.9, 1.1 and 4.6 mg/g, at a temperature of 20 °C. This paper will show the data from the long-term stability study that took place over 52 weeks. The method used complies with ISO Guide 35, the BCR Guideline for Feasibility Studies and ISO Guide 34. According to the statistical parameters used in both studies, the stability of ethanol in water CRM was confirmed for all of the mass fractions studied.  相似文献   

6.
Internationally, certified ethanol reference materials are required to calibrate breathalysers and blood-alcohol measurement instruments. The CSIR National Metrology Laboratory of South Africa provides certified aqueous ethanol solutions with traceability to the SI. Ethanol solutions in the concentration range 10 mg/100 g to 20 g/100 g are prepared gravimetrically by mixing ethanol and reagent quality water. To verify the concentration of the ethanol it is oxidized to acetic acid with potassium dichromate in the presence of sulphuric acid. The unreacted potassium dichromate is back-titrated with sodium thiosulphate. The method utilizes gravimetry and titrimetry, which are both primary methods. This paper addresses aspects of ethanol-certified reference materials that have not been previously published: traceability, stability of unpreserved ethanol solutions, homogeneity, quality control measures and the effect of reproducibility on the measurement uncertainty. Presented at -- “BERM-10” -- April 2006, Charleston, SC, USA  相似文献   

7.
The certification of the purity of CRMs intended for calibration, where no other certified material already exists for comparison, raises principle questions on how to determine the purity of a "first" calibrant in the calibration hierarchy. We developed and certified two calibration CRMs for their purity in thyroid hormones taking into consideration inorganic residues, residual solvents and organic impurities detectable by HPLC-UV and HPLC-MS. IRMM-468 was certified for a thyroxine (T(4)) mass fraction of 98.6+/-0.7% and IRMM-469 was certified for a 3,3',5-triiodothyronine (T(3)) mass fraction of 97.1+/-0.7%. The approach we used aims to determine the purity of these two CRMs to the best of our knowledge and taking all scientific aspects properly into account for the estimation of an uncertainty related to the stated purity.  相似文献   

8.
Certified reference materials (CRMs) for water content with good accuracy and homogeneity are required for calibration or validation of the Karl Fischer titration and for establishing the traceability of water content results. Three such CRMs were produced and certified: GBW 13512, 13513 and 13514 are based on solvent mixtures consisting of butanol, xylene and propylene carbonate with water contents of 10.01, 1.067 and 0.139?mg/g, respectively, certified by the Karl Fischer coulometric and volumetric methods. These CRMs were prepared, dispensed and sealed under a humidity equal to the equilibrated humidity of their headspace. In this way, the between-bottle homogeneity uncertainty (u H,rel) could be kept as low as u H,rel?=?0.12?% for GBW 13512. The certification methods, that is, Karl Fischer coulometric and volumetric methods, were calibrated using in-house water standards prepared by gravimetry. The results were traceable to the SI unit of mass. The relative deviation of the water contents between the two methods for GBW 13512 was only 0.05?%. The expanded uncertainty (U, k?=?2) of three CRMs was 0.12, 0.024 and 0.012?mg/g, respectively. These CRMs for water content with good accuracy can be applied in the calibration or validation of measurement procedures to ensure accurate and comparable results.  相似文献   

9.
We report the development of a National Institute of Metrology (NIM) hemoglobin A1c (HbA1c) certified reference material (CRM). Each CRM unit contains about 10 μL of hemoglobin. Both hemoglobin and glycated hemoglobin were quantitatively determined by high-performance liquid chromatography (HPLC)–isotope dilution mass spectrometry (IDMS) with synthesized VHLTPE and glycated VHLTPE as standards. The mass fraction of synthesized VHLTPE or glycated VHLTPE was also quantitatively determined by HPLC-IDMS with NIM amino acid CRMs as standards. The homogeneity and stability of the CRMs were examined with a commercial HbA1c analyzer based on the HPLC principle. Fifteen units were randomly selected for homogeneity examination, and statistical analysis showed there was no inhomogeneity. Examination of the stability showed that the CRM was stable for at least 6 months at -80 °C. Uncertainty components of the balance, amino acid purity, hydrolysis and proteolysis efficiency, method reproducibility, homogeneity, and stability were taken into consideration for uncertainty evaluation. The certified value of NIM HbA1c CRM was expressed as the ratio of HbA1c to total hemoglobin in moles, and was (9.6 ± 1.9)% . The CRM can be used as a calibration or validation standard for clinical diagnostics. It is expected to improve the comparability for HbA1c measurement in China.  相似文献   

10.
Solution-doped metal powder pellets as well as aspirated liquids were used as calibration samples to analyze pure copper and zinc certified reference materials (CRMs) by femtosecond laser ablation ICP-MS. It was demonstrated that calibration by copper pellets resulted in relative deviations up to 20%, whereas fs-LA-ICP-MS among copper-based CRMs led to inaccuracies in the same range unless nominal mass fractions were chosen to be <3 mg/kg. Calibration by zinc pellets generally provided better accuracy. Depending on the analyte considered, deviations below 10% were obtained even for mass fractions close to the limit of quantification. Our data, therefore, indicate solution-doped metal powder pellets to be suitable as calibration samples for fs-LA-ICP-MS of metals. Furthermore, the utilization of liquid standards for calibration was found to result in stronger deviations of up to 50% for both copper and zinc samples which, in addition, turned out to be dependent on the plasma conditions.   相似文献   

11.
Poly(ethylene glycol) (PEG) is a useful water-soluble polymer that has attracted considerable interest in medical and biological science applications as well as in polymer physics. Through the use of a well-calibrated evaporative light-scattering detector coupled with high performance supercritical fluid chromatography, we are able to determine exactly not only the average mass but also all of the molecular mass fractions of PEG samples needed for certified reference materials issued by the National Metrology Institute of Japan. In addition, experimental uncertainty was determined in accordance with the Guide to the expression of uncertainty in measurement (GUM). This reference material can be used to calibrate measuring instruments, to control measurement precision, and to confirm the validity of measurement methods when determining molecular mass distributions and average molecular masses. Especially, it is suitable for calibration against both masses and intensities for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Figure Comparison between the molecular mass fractions of PEG 1000 before calibration (si) (○) and after calibration (wi) (⧫). The error bar shows the expanded uncertainty of k = 2 of each mass fraction  相似文献   

12.
The accuracy and uncertainty of the coulometric measurement results of reference materials for acidimetric titration were examined in this study. The results for amidosulfuric acid and potassium hydrogen phthalate are presented. The uncertainty was investigated by examining the dependency on the sample size and on the electrolysis current. Changes in the titration parameters did not result in any significant effects on the titration results. Acidimetric standards with the certified value linked to the SI were developed. In addition, the intercomparison of acidimetric standards was carried out by gravimetric titration, and the relationship between our coulometric results was determined. Furthermore, due to recent internationalization, not only the traceability to the SI but also the relationship and consistency of their analytical data have gained increasing importance. Our results were validated using certified reference materials (CRMs) obtained from different National Metrology Institutes (NMIs), and their relationships are presented. Presented at -- “BERM-10” -- April 2006, Charleston, SC, USA.  相似文献   

13.
Since the uncertainty of each link in the traceability chain (measuring analytical instrument, reference material or other measurement standard) changes over the course of time, the chain lifetime is limited. The lifetime in chemical analysis is dependent on the calibration intervals of the measuring equipment and the shelf-life of the certified reference materials (CRMs) used for the calibration of the equipment. It is shown that the ordinary least squares technique, used for treatment of the calibration data, is correct only when uncertainties in the certified values of the measurement standards or CRMs are negligible. If these uncertainties increase (for example, close to the end of the calibration interval or shelf-life), they are able to influence significantly the calibration and measurement results. In such cases regression analysis of the calibration data should take into account that not only the response values are subjects to errors, but also the certified values. As an end-point criterion of the traceability chain destruction, the requirement that the uncertainty of a measurement standard should be a source of less then one-third of the uncertainty in the measurement result is applicable. An example from analytical practice based on the data of interlaboratory comparisons of ethanol determination in beer is discussed. Received: 5 October 2000 Accepted: 3 December 2000  相似文献   

14.
介绍了特种合金钢系列标准物质的研制过程。采用合理的冶炼锻轧工艺,选取不同部位的样品进行均匀性检验,确定了15种元素的认定值及扩展不确定度,并进行了线性、一致性考察以及与国内外同类标准物质的比对。结果表明,本套特种合金钢系列标准物质的均匀性良好,定值准确且有良好的梯度分布。  相似文献   

15.
A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called “emerging” and “novel” BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and where possible, trueness was verified by analysis of certified reference materials (CRMs). Recoveries of analytes were between 80 and 119%, while the repeatability in terms of relative standard deviations (RSDs) was in the range from 1.2 to 15.5%. The measured values for both analyzed CRMs agreed with the provided consensus values, revealing the recovery of reference concentrations in 72–119% range. The elaborated method met the sensitivity criterion according to Commission Recommendation 2014/118/EU on monitoring of BFRs in food products for majority of the compounds. The concentrations of polybrominated diphenyl ethers (PBDEs) in real samples determined by HPLC-APPI-Orbitrap-MS method and validated gas chromatography–high-resolution mass spectrometry (GC–HRMS) method were found to be in a good agreement.  相似文献   

16.
Certified reference materials (CRMs) are playing an increasingly important role in environmental monitoring in Japan. The National Metrology Institute of Japan (NMIJ)/National Institute of Advanced Industrial Science and Technology (AIST) has been developing CRMs of organic calibration solutions since 2003, and has issued several NMIJ CRMs. The development of these materials was conducted at the NMIJ in cooperation with candidate material producers. The freezing-point depression method was principally adopted for assessment of the purity of starting materials to give reliable certified values. Gas chromatography with flame ionization detection (GC–FID) and/or high-performance liquid chromatography (HPLC), which are based on independent principles and whose levels of accuracy are well evaluated, were applied in combination with other methods to avoid any possible analytical bias. Purity assessment is outlined for two typical examples, 1,1-dichloro-2,2-bis(p-chlorophenyl)ethane (p,p′-DDD) and 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (p,p′-DDT), which were used as starting materials for a CRM under development. Methods adopted for gravimetric preparation and ampouling of solutions were qualified and optimized to reduce the uncertainties of certified values due to these factors. Furthermore, a new experimental scheme for assessment of stability and preparation variation is proposed for the proper estimation of uncertainties. Presented at BERM-11, October 2007, Tsukuba, Japan.  相似文献   

17.
Purity certified reference materials (CRMs) are playing a key role in metrological traceability, because they form the basis for many traceability chains in chemistry. Recently, the National Metrology Institute of Japan (NMIJ) has developed two purity CRMs for creatinine (NMIJ CRM 6005-a) and urea (NMIJ CRM 6006-a), because the concentrations of these two compounds are frequently measured in clinical laboratories for monitoring the renal functions. In the certification of purity CRMs, it is essential that the materials have been thoroughly characterized for purity, and the purity should preferably be determined directly by a primary method of measurements. In the development of these two CRMs, we used the purified materials as candidates. The certified values were assigned based on the results of two different methods; acidimetric titration and nitrogen determination by the Kjeldahl method. Since both methods cannot distinguish some impurities from the target compounds, major impurities in the candidate materials were also identified, quantified, and subtracted. These CRMs can provide a traceability link between routine clinical methods and SI units. Presented at BERM-11, October 2007, Tsukuba, Japan.  相似文献   

18.
Four mineral oil certified reference materials (CRMs), NMIJ CRM 7902-a, CRM 7903-a, CRM 7904-a, and CRM 7905-a, have been issued by the National Metrology Institute of Japan, which is part of the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), for the determination of polychlorinated biphenyls (PCBs). The raw materials for the CRMs were an insulation oil (CRM 7902-a and CRM 7903-a) and a fuel oil (CRM7904-a and CRM 7905-a). A solution of PCB3, PCB8, and technical PCB products, comprising four types of Kaneclor, was added to the oil matrices. The total PCB concentrations in the PCB-fortified oils (CRM 7902-a and CRM 7904-a) are approximately 6 mg kg−1. In addition, the mineral oils which were not fortified with PCBs were also distributed as CRMs (CRM 7903-a and CRM 7905-a). Characterization of these CRMs was conducted by the NMIJ/AIST, where the mineral oils and the PCB solution were analyzed using multiple analytical methods such as dimethylsulfoxide extraction, normal-phase liquid chromatography, gel permeation chromatography, reversed-phase liquid chromatography, and chromatography using sulfoxide-bonded silica; and/or various capillary columns for gas chromatography, and two ionization modes for mass spectrometry. The target compounds in the mineral oils and those in the PCB solution were determined by one of the primary methods of measurement, isotope dilution–mass spectrometry (ID-MS). Certified values have been provided for 11 PCB congeners (PCB3, 8, 28, 52, 101, 118, 138, 153, 180, 194, and 206) in the CRMs. These CRMs have information values for PCB homologue concentrations determined by using a Japanese official method for determination of PCBs in wastes and densities determined with an oscillational density meter. Because oil samples having arbitrary PCB concentrations between respective property values of the PCB-fortified and nonfortified CRMs can be prepared by gravimetric mixing of the CRM pairs, these CRMs can be used for validation of PCB analyses using various instruments which have different sensitivities. Figure Preparation and certification processes of the mineral oil CRMs (example shown is polychlorinated biphenyls in insulation oil, high/low concentrations) Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

19.
Accreditation and Quality Assurance - The National Metrology Institute of Japan (NMIJ) has established three certified reference materials (CRMs) in electrolytic conductivity with a primary...  相似文献   

20.
Several reference materials (RMs) and certified reference materials (CRMs) are widely used in Romania as measurement standards in different spectrochemical measurements. Among them, single element standard solution certified for their mass concentration play a key role in ensuring the required traceability of results expressed in this measurement unit. A short review of the locally available elemental RMs and CRMs used in atomic spectrometry or in other analytical techniques where aqueous standard solutions are required (usually called RMs or CRMs for spectrometry) is given. The experience of the INM in preparation and certification of such materials is described. Some aspects regarding their use for ensuring the accuracy and for confirmation of the traceability of analytical measurements, especially through calibration and metrological validation of main instrument performances, are discussed.  相似文献   