首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.
Figure
Scheme of the 2D-LC/2D-GC system  相似文献   

2.
In common with all gas chromatography (GC) methods, comprehensive two-dimensional gas chromatography (GC x GC) has the potential to provide both qualitative and quantitative analysis. There are fundamental differences in the way one-dimensional (1D-GC) and GC x GC results are interpreted for these parameters. Since 1D-GC produces a single measured peak in the chromatogram, there is a single retention time, and associated with this a single peak response (either area or height). Peak area and height are related by peak width. GC x GC produces a series of modulated peaks at the detector. Thus, the peak metrics of retention, area and height for one component are now not simple single values for one peak, but rather are derived from the multiple peak distribution generated by the modulation process. The peak retention is interpreted in terms of two-dimensional coordinates in a retention plane. In this study, a brief background review to quantification in GC x GC is provided. Previous reviews cover aspects of quantitative GC x GC studies up to the year 2005, including different approaches to quantification, and reports of quantitative analysis with different detectors, for different compounds classes, and in different matrices. Other studies have developed chemometric approaches based on multivariate analysis to provide quantitative reporting of individual compounds. The coverage of the earlier reviews has been updated to include material that has been presented since 2005 and includes considerations of valve-based modulation. Recently the modulation ratio (M(R)) concept was proposed and intended to clarify the meaning of modulation number (n(M)) in GC x GC, which was shown to be a rather poorly defined parameter. Based on the prior studies that introduced this concept, the role of quantitative analysis is investigated here through calculation of the peak areas and peak area ratios of selected series of modulated peaks in GC x GC. The application of isotopically labelled reference compounds for polycyclic aromatic hydrocarbon (PAH) analysis is used here to develop the quantitative metric approach. It is shown that by selecting the two or three major modulated peaks for solutes and internal standards, comparing the response ratio with the sum of all modulated peaks and also with the reference non-modulated result, quantification is statistically equivalent. Thus, adequate quantitative analysis and calibration can be accomplished by using selected major modulated peaks for each compound. This may simplify quantitative interpretation of GC x GC data.  相似文献   

3.
Polycyclic aromatic hydrocarbons (PAHs) with four to six rings are potent carcinogens. This study analyzed ten of the sixteen US EPA priority PAHs using reversed-phase liquid chromatography/tandem mass spectrometry (LC/MS/MS) in selected reaction monitoring mode with two ionization sources: positive atmospheric pressure chemical ionization (APCI+) or positive elecrtrospray ionization (ESI+) with tropylium post-column derivatization. Several factors were investigated, including mobile phases, stationary phases of columns and chromatographic temperature, to determine how optimal separation and sensitivity might be achieved. Methanol used as an organic mobile phase provided better sensitivities for most PAHs than acetonitrile, although some PAHs co-eluted. Acidic buffers did not increase analyte signals. Use of Restek Pinnacle II PAH columns (250 x 4.6 mm or 250 x 2.1 mm, 5 microm) with water/acetonitrile gradient at 27 degrees C made possible a good separation of the ten analytes. [M]+. were the best precursor ions in both APCI and ESI, although fluoranthene could not be detected in ESI mode when tropylium post-column derivatization was performed. [M-28]+ and [M-52]+ were the major product ions of PAHs after collision-induced dissociation, a result of neutral losses of C(2)H(4) and (C(2)H(2))(2), respectively. Chromatographic separation for PAH isomers was crucial because the mass spectra were so similar that even MS/MS could not distinguish them from each other. The recoveries of sample preparations of PAHs spiked onto air-sampling filters ranged between 77.5 and 106% with relative standard deviations between 1.1 and 15.9%. This method was validated by analyzing NIST SRM 1649a (urban dust), producing results comparable with the certified PAH concentrations. The detection limits using APCI and ESI interfaces, defined as three times the noise levels, ranged between 0.23 and 0.83 ng and between 0.16 and 0.84 ng of on-column injection, respectively.  相似文献   

4.
Pressurised fluid extraction (PFE) was used for the measurement of 13 polycyclic aromatic hydrocarbons (PAHs) adsorbed on different types of particles: two model particles (PAH-coated silica, PAH-coated graphite) and two natural atmospheric particles (urban dust and diesel exhaust, from NIST reference materials). Samples were analysed by gas chromatography coupled to mass spectrometry. Extraction efficiency was evaluated with internal standard recovery yields and was shown to depend on the nature of the particle, on the structure of the analytes and on the PAH concentration. Extraction conditions (toluene, 130°C, 130 bar, 2 × 8-min static cycles) were optimised to extract PAHs when strongly interacting with solid matrices and were validated by the analysis of two PAH-certified materials.  相似文献   

5.
A method for peak detection in two-dimensional chromatography is presented. The algorithm applies first the methods developed for peak detection in one-dimensional chromatography to detect peaks in one dimension. In a second step, a decision tree is applied to decide which one-dimensional peaks are originated from the same compound and have to be 'merged' into one two-dimensional peak. To this end, different features of the peaks (second-dimension peak regions and second-dimension retention times) are compared and different criteria (common peak regions, retention time differences, unimodality in the first dimension) are applied. Different options can be used, depending on the nature of the data. The user controls this decision tree by establishing several options and "switches". The algorithm was tested with GCxGC chromatograms obtained for a commercial air-freshener sample, detecting and merging the modulated peaks belonging to the same compound. Recommendations for the set of options and switches are given. A utility that calculates and sums peak areas from merged peaks is added to facilitate automated quantification. Although the algorithm was developed for GCxGC, its application to comprehensive two-dimensional liquid chromatography (LCxLC) data should at most require minor modifications.  相似文献   

6.
The National Metrology Institute of Japan has issued a certified reference material of tunnel dust for polycyclic aromatic hydrocarbons (PAHs) and toxic element analyses. PAH certification was performed using isotope dilution mass spectrometry with deuterium-labeled PAHs as internal standards. Three extraction techniques (microwave-assisted extraction with toluene/methanol, Soxhlet extraction with toluene, and pressurized liquid extraction with toluene) were used, and the extracts were measured by gas chromatography/mass spectrometry with two different columns. For values of PAHs, 11 PAHs are provided as certified values between 0.294 and 20.3 mg/kg, and five PAHs are provided as information values. Certified values of five toxic elements (Cr, Ni, Pb, Mn, and Cd) obtained from microwave-assisted digestions and a combination of measurement techniques are also provided between 43.4 and 10.71 × 103 mg/kg.  相似文献   

7.
Polycyclic aromatic hydrocarbons (PAHs) are common pollutants present in atmospheric aerosols and other environmental mixtures. They are of particular air quality and human health concerns as many of them are carcinogenic toxins. They also affect absorption of solar radiation by aerosols, therefore contributing to the radiative forcing of climate. For environmental chemistry studies, it is advantageous to quantify PAH components using the same analytical technics that are commonly applied to characterize a broad range of polar analytes present in the same environmental mixtures. Liquid chromatography coupled with photodiode array and high-resolution mass spectrometric detection (LC-PDA-HRMS) is a method of choice for comprehensive characterization of chemical composition and quantification of light absorption properties of individual organic compounds present in the environmental samples. However, quantification of non-polar PAHs by this method is poorly established because of their imperfect ionization in electrospray ionization (ESI) technique. This tutorial article provides a comprehensive evaluation of the quantitative analysis of 16 priority pollutant PAHs in a standard reference material using the LC–MS platform coupled with the ESI source. Results are further corroborated by the quantitation experiments using an atmospheric pressure photoionization (APPI) method, which is more sensitive for the PAH detection. The basic concepts and step-by-step practical guidance for the PAHs quantitative characterization are offered based on the systematic experiments, which include (1) Evaluation effects of different acidification levels by formic acid on the (+)ESI-MS detection of PAHs. (2) Comparison of detection limits in ESI+ versus APPI+ experiments. (3) Investigation of the PAH fragmentation patterns in MS2 experiments at different collision energies. (4) Calculation of wavelength dependent mass absorption coefficient (MACλ) of the standard mixture and its individual PAHs using LC-PDA data. (5) Assessment of the minimal injected mass required for accurate quantification of MACλ of the standard mixture and of a multi-component environmental sample.  相似文献   

8.
Fast screening of wash oils is demonstrated using comprehensive two-dimensional gas chromatography (GCxGC). Wash oils are used in ethylene production plants to minimize compressor fouling. The composition of a wash oil determines its effectiveness in solubilizing heavy hydrocarbons. In particular, the relative amount of 1- and 2-ring aromatics is important. The presence of oxygenates is undesirable because of adverse effects to the process. It is shown that GCxGC is well suited for this application. Species in wash oils are separated and grouped into three bands: a nonpolar aliphatics band, 1- and 2-ring aromatics band, and polyaromatics band. For a given polar secondary column, the spacing between bands in the second dimension can be adjusted in a broad range by selecting a primary column and an oven-temperature-programming rate. Integration of GCxGC peaks is evaluated using a standard GC integration program and a new GCxGC integration program. Consistent results are obtained using both programs for well-separated GCxGC peaks with relative differences for individual peak ranging from 0.04% to 1.6%. Peak responses are integrated by the GCxGC software, and the relative amounts of aromatics content and aliphatics content are estimated by peak response percent with relative standard deviations ranging from 0.15% to 2.8% (n = 3).  相似文献   

9.
A method has been developed for analysis of the highly potent polycyclic aromatic hydrocarbon (PAH) carcinogens dibenzo(a,l)pyrene, dibenzo(a,h)pyrene, and dibenzo(a,i)pyrene (molecular weight 302) present in small amounts in diesel and air particulate material. The method can also be used for analysis of the PAH benzo(a)pyrene, coronene, and perylene, for which reference and certified values are available for the standard reference materials used for validation of the method—SRM 1649a (urban dust) and SRM 2975 (diesel particulate matter). The only NIST values that have been published for these dibenzopyrene isomers in the analyzed SRM are reference values for dibenzo(a,i)pyrene and dibenzo(a,h)pyrene in SRM 1649a. The concentrations determined in the SRM were in good agreement with reported NIST-certified and reference values and other concentrations reported in the literature. Standard reference material 1650 (diesel particulate matter) was also analyzed. The method could not, however, be validated using this material because certification of SRM 1650 had expired. The method is based on ultrasonically assisted extraction of the particulate material, then silica SPE pre-separation and isolation, and, separation and detection by hyphenated LC–GC–MS. The method is relatively rapid and requires only approximately 1–5 mg SRM particulate material to identify and quantify the analytes. Low extraction recoveries for the analytes, in particular the dibenzopyrenes, when extracting diesel SRM 2975 and 1650 resulted, however, in the dibenzopyrenes being present in amounts near their limits of quantifications in these samples. The method’s limit of quantification (LOQ), based on analyses of SRM 1649a, is in the range 10–77 pg. By use of this method more than 25 potential PAH isomers with a molecular weight of 302 could be separated.  相似文献   

10.
A selective clean-up procedure using immunoaffinity solid-phase extraction was applied for the trace-level determination of polycyclic aromatic hydrocarbons (PAHs) in urban waste water and sewage sludges used for soil amendment. Anti-pyrene antibodies have been immobilized on a silica-based sorbent and the cross-reactivity of the antibodies towards structurally related compounds were allowed to extract the whole class of priority PAHs. The selectivity of the antibodies provided clean extracts from sludges and, therefore, the identification and quantification were shown to be easier using either liquid chromatography (LC) with UV diode array and fluorescence detection in series or gas chromatography-mass spectrometry (GC-MS), although some loss of up to 50% was observed for the clean-up. The identification of the PAHs by matching of UV and MS spectra was greatly improved. The procedure, including immunoclean-up and LC coupled to diode array and fluorescence detection, was validated using certified reference materials with native PAHs of concentrations in the range of 0.57-2.16 mg/kg (dry sludges).  相似文献   

11.
Coal is a non renewable fossil fuel, used mainly as a source of electrical energy and in the production of coke. It is subjected to thermal treatment, pyrolysis, which produces coke as a main product, in addition to a condensed liquid by-product, called tar. Tar is a complex mixture of organic compounds which contains different chemical classes, presenting aromatic and sulphur heterocyclic compounds. In general, identification of these compounds requires steps of isolation and fractionation, mainly due to co-elution of these compounds with polyaromatic hydrocarbons (PAH). The objective of this work is to characterize the sulphur compounds present in the coal tar obtained via pyrolysis, using comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry detector (GC×GC/TOFMS). Coal samples from the State of Paraná, Brazil were subjected to laboratorial scale pyrolysis. Several experimental conditions were tested, such as sample weight (5, 10 and 15g), heating ramp (10, 25 and 100°C/min) and final temperature (500, 700 and 900°C). Samples were analyzed by one dimensional gas chromatography (1D-GC) coupled to a quadrupole mass spectrometry detector (GC/qMS) and two-dimensional gas chromatography with time-of-flight mass spectrometry detector (GC×GC/TOFMS). The higher amount of sulphur compounds was obtained at a final temperature of 700°C and a heating ramp of 100°C/min. The main classes observed in the color plot were thiophenes, benzothiophenes and alkylated dibenzothiophenes. GC×GC/TOFMS allowed the identification of the greater number of compounds and the separation of several sulphur compounds from one another. Moreover, separation of sulphur compounds from polyaromatic hydrocarbons and phenols was achieved, which was not possible by 1D-GC. Comparing GC×GC/TOFMS and 1D-GC (SIM mode) also showed that 1D-GC, one of the most employed quantification tools for sulphur compounds, can be misleading for detection, identification and quantification, as the number of isomers of sulphur compounds found was greater than theoretically possible.  相似文献   

12.
There is a fundamental difference between data collected in comprehensive two-dimensional gas chromatographic (GCxGC) separations and data collected by one-dimensional GC techniques (or heart-cut GC techniques). This difference can be ascribed to the fact that GCxGC generates multiple sub-peaks for each analyte, as opposed to other GC techniques that generate only a single chromatographic peak for each analyte. In order to calculate the total signal for the analyte, the most commonly used approach is to consider the cumulative area that results from the integration of each sub-peak. Alternately, the data may be considered using higher order techniques such as the generalized rank annihilation method (GRAM). Regardless of the approach, the potential errors are expected to be greater for trace analytes where the sub-peaks are close to the limit of detection (LOD). This error is also expected to be compounded with phase-induced error, a phenomenon foreign to the measurement of single peaks. Here these sources of error are investigated for the first time using both the traditional integration-based approach and GRAM analysis. The use of simulated data permits the sources of error to be controlled and independently evaluated in a manner not possible with real data. The results of this study show that the error introduced by the modulation process is at worst 1% for analyte signals with a base peak height of 10xLOD and either approach to quantitation is used. Errors due to phase shifting are shown to be of greater concern, especially for trace analytes with only one or two visible sub-peaks. In this case, the error could be as great as 6.4% for symmetrical peaks when a conventional integration approach is used. This is contrasted by GRAM which provides a much more precise result, at worst 1.8% and 0.6% when the modulation ratio (MR) is 1.5 or 3.0, respectively for symmetrical peaks. The data show that for analyses demanding high precision, a MR of 3 should be targeted as a minimum, especially if multivariate techniques are to be used so as to maintain data density in the primary dimension. For rapid screening techniques where precision is not as critical lower MR values can be tolerated. When integration is used, if there are 4-5 visible sub-peaks included for a symmetrical peak at MR=3.0, the data will be reasonably free from phase-shift-induced errors or a negative bias. At MR=1.5, at least 3 sub-peaks must be included for a symmetrical peak. The proposed guidelines should be equally relevant to LCxLC and other similar techniques.  相似文献   

13.
The application of differential scanning calorimetry (DSC) for purity determination is well documented in literature and is used amongst others in the analysis of pure organic crystalline compounds. The aim of this work is to examine whether the DSC method for purity determination consistently produces values for the purity of polycyclic aromatic hydrocarbons (PAHs) which are sufficiently accurate as required for the certification of reference materials. For this purpose, 34 different existing PAH certified reference materials were tested. The DSC results are shown to be consistent with the results obtained by other methods assessing the organic impurities content in PAHs, like gas chromatography (GC), high performance liquid chromatography (HPLC) and mass spectrometry. Significant differences between the measured values and the certified purity values were observed only in a limited number of cases.  相似文献   

14.
A procedure for the determination of very low polycyclic aromatic hydrocarbons (PAHs) concentrations in sediment samples has been developed by gas chromatography-quadrupole ion trap mass spectrometry (GC-QIT MS) after extraction with dichloromethane and purification by using silica gel cleanup. Identification and quantification of analytes were based on the selected ion storage (SIS) strategy using deuterated PAHs as internal standards. In order to search out the main factors affecting the SIS mass spectrometry efficiency, four MS parameters, including target total ion count (TTIC), waveform amplitude (WA), transfer line (XLT) and ion trap temperatures (ITT) were subjected to a complete multifactorial design. The most relevant parameters obtained (TTIC and WA) were optimized by a rotatable and orthogonal composite design. Optimum values for these parameters were selected for the development of the method involving PAH determination in sediment samples. The optimized method exhibited a range of 111-760% higher signal-to-noise (S/N) ratios for PAHs in comparison with the method operated by the default conditions, demonstrating that the multifactorial optimization contributed to substantially improve the sensitivity of the GC-QIT MS determination. The accuracy of the method was verified by analyzing NWRI EC-3 certified reference material (Lake Ontario sediment). The selectivity, sensitivity (limits of quantification were in the range of 0.02-11.0 ng g(-1)), accuracy (recoveries >or=77%) and precision (RSD相似文献   

15.
Micro-scale sealed vessel thermal desorption-gas chromatography-mass spectrometry (MSSV-TD-GC-MS) has been applied to the analysis of airborne particulate matter using the US NIST Standard Reference Material (SRM1649a) urban dust. We make qualitative comparisons with open system desorption and illustrate that caution should be used when using the technique without an open system comparison. We report linear responses over the same particulate mass range (1-5 mg) and good reproducibility [SD< or =0.62 mg kg(-1) (< or = 11%)]. We show linearity for a series of 10 n-alkanes and 10 polycyclic aromatic hydrocarbons (PAHs) in the SRM. The technique is also shown to be quantifiable (PAH concentrations typically 4-6 mg kg(-1)).  相似文献   

16.
The sources of uncertainty affecting measurements of pollutants include sample collection, handling and stocking, and analytical procedure. With regard to chemical analysis, MS detection offers a series of advantages for resolving complex mixtures and identify and quantify analytes present at very small extents. Nevertheless, it presents some problems of reproducibility, which can affect the quality of quantitative data. PAH represent key-compounds among atmospheric pollutants and are usually evaluated by means of dedicated methods comprising MS detection. Based upon the above considerations, an analytical method has been standardized, suitable for determining PAH in atmospheric aerosols and diesel particulate exhausts. To test the procedure, both diesel particulate and urban aerosol NIST reference materials (SRM-2975 and SRM-1649A, respectively) have been processed and the results have been compared with certified and/or literature data. The results obtained are shortly discussed.  相似文献   

17.
A method for the determination of 27 polycyclic aromatic hydrocarbons (PAHs) in sludge from wastewater treatment plants (WWTPs) located in urban, industrial or rural zones is presented. PAHs were extracted by matrix solid-phase dispersion (MSPD) assisted by sonication. Purification of extracts was carried out by solid-phase extraction with C(18) and PAHs were eluted with acetonitrile. PAHs were determined by isotope dilution gas chromatography with electron impact mass spectrometric detection in the selected ion-monitoring mode (GC-MS-SIM), using deuterated PAHs as internal standards. The limits of detection ranged from 0.03 ng/g for acenaphthylene to 0.45 ng/g for benzo[b]naphtho[2,1-d]thyophene. After optimization, the method was validated with a certified reference sludge. The proposed analytical method was applied to determine PAH levels in sewage sludge samples collected from 19 water treatment plants located in the province of Madrid (Spain). In most of the examined samples, phenanthrene was the main compound with a mean concentration of 1062 ng/g. PAHs were detected in all of the samples, with total concentrations between 390 and 6390 ng/g dry weight for the 27 PAHs analyzed and from 310 to 5120 ng/g dry weight for the sum of the 10 PAHs considered in the draft European Union directive.  相似文献   

18.
Polycyclic aromatic hydrocarbon (PAH) compounds and amino acids (AAs) are both ubiquitous throughout the universe and can be co-located in mineral matrices (e.g., meteorites); therefore, co-detection of PAHs and AAs associated with terrestrial and extra-terrestrial minerals is of interest. Nine PAH compounds representing four chemical classes of PAH (unsubstituted, acetyl-, amino-, and nitro-substituted) were applied onto the surface of quartz, plagioclase, olivine, and ilmenite mineral standards and analyzed using laser desorption/ionization Fourier transform mass spectrometry (LD-FTMS). Mass-to-charge peaks derived from PAH compounds were detected from the surfaces of all minerals evaluated. All PAH compounds were detected in the positive ion mode, whereas only nitro-substituted PAH compounds were detected in negative ion mode. In this and earlier studies, the ability to directly detect mineral-associated AAs by LD-FTMS was dependent on the mineral geomatrix. On iron-bearing minerals AAs appeared as highly fragmented ions in the spectra or were not detectable; however, the addition of the PAH chrysene enabled the ionization and detection of AAs threonine and histidine by LD-FTMS. Thus, for mineral systems such as meteorites, interstellar dust particles, soils, and sediments, the co-detection of AAs associated with PAHs by LD-FTMS is feasible.  相似文献   

19.
The review is devoted to the recent studies in the field of high-performance liquid chromatography (HPLC) of polycyclic aromatic hydrocarbons (PAHs). The existing certified techniques, developments of synthesis of new sorbents for separating PAH isomers, and study of the retention mechanism are discussed. It also considers the modern methods of extraction and concentration of PAHs, mainly from environmental objects, which are compatible with subsequent identification by HPLC, as well as the necessity of analytical control of contamination of the environment, food sources, and food supplies with PAHs.  相似文献   

20.
Metrics for evaluation of separation performance of comprehensive two-dimensional gas chromatography (GCxGC) and for quantitative comparison of that performance with similar performance of its 1D (one-dimensional) counterparts are described. The performance improvement can be expressed via reduction in the saturation of a chromatogram or-in the case of the uniform distribution of peaks along the second dimension--via the peak capacity gain due to GCxGC. An order of magnitude peak capacity gain due to the comprehensive GCxGC is possible under optimal conditions. Optimal parameters of the second dimension column as well as the optimal operational conditions for that column and for the modulator in a comprehensive GCxGC are also presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号