首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A silica-based monolithic stationary phase prepared by the sol-gel process in a 100 microm I.D. fused-silica (FS) capillary has been modified chemically with 3-mercaptopropyl trimethoxysilane followed by immobilization of a strong cation-exchange (SCX) type chiral selector, (S)-N-(4-allyloxy-3,5-dichlorobenzoyl)-2-amino-3,3-dimethylbutane phosphonic acid, by radical addition reaction onto the reactive sulfhydryl surface. After a fine-tuning of the mobile phase composition, the enantioselective capillary column was evaluated for the separation of various chiral basic drugs by enantioselective non-aqueous capillary electrochromatography (CEC), in comparison to capillary column analogs packed with 3.5 microm silica particles having attached the same selector. The performance of the monolithic silica column was further compared to corresponding polymethacrylate-based organic polymer monoliths. The study indicated that strong counter-ions such as 2-aminobutanol or N,N,N',N'-tetramethylethylenediamine are needed, although they reduce the electroosmotic flow velocity and separation factors in comparison to less efficient counter-ions, in order to allow the elution of the oppositely charged solutes in the ion-exchange retention mode within reasonable run time and as sharp zones. In contrast, weak counter-ions such as N,N-diisopropylethylamine (Huenig base) provided stronger electroosmotic flow and much better separation factors, but relatively poor peak efficiencies. Overall, with the chemically functionalized monolithic silica column the high quality separations of packed column analogs could be approximated, with regards to both separation factors and peak performances. On the other hand, the monolithic capillary column certainly outperformed the packed column in terms of system robustness under capillary electrochromatography conditions and showed excellent column longevity. The enantioselective strong cation-exchange-type monolithic silica column performed also well in comparison to the organic polymer monolith.  相似文献   

2.
采用一步键合法制备了烯丙胺-β-环糊精/Cu_2O(Ally-β-CD/Cu_2O)毛细管电色谱整体柱,并考察了制备整体柱的主要影响因素。通过扫描电子显微镜(SEM)、X-射线光电子能谱(XPS)、X-射线衍射(XRD)对整体柱柱内固定相进行表征。以硫脲为中性标记物测定了柱效,柱效达到47 658 N/m。对D,L-组氨酸对映体的分离度RS达到3.82,整体柱在连续使用72h或间歇使用2个月后仍具有良好的分离能力,表明整体柱具有良好的重现性和稳定性,同时具备较好的手性拆分能力。运用该整体柱对盐酸克伦特罗对映体进行了拆分,达到基线分离,分离度达到2.89。  相似文献   

3.
By an on-column sol-gel process, a chiral monolithic stationary phase was prepared by the fusion of permethyl-beta-cyclodextrin-silica (Chira-Dex-silica) particles and by linking them to the internal capillary wall. The resulting monolith is stable toward voltage (30 kV) and pressure (300 bar) and possesses a high efficiency (up to 100,000 theoretical plates per meter). Efficient enantiomeric separation of various chiral compounds by pressure-supported capillary electrochromatography (CEC) was achieved. When comparing this method to capillary liquid chromatography (LC) employing the same column in an unified equipment, CEC shows a twofold higher column efficiency at comparable elution times and hence better resolution factors.  相似文献   

4.
Pepsin‐modified affinity monolithic capillary electrochromatography, a novel microanalysis system, was developed by the covalent bonding of pepsin on silica monolith. The column was successfully applied in the chiral separation of (±)‐nefopam. Furthermore, the electrochromatographic performance of the pepsin‐functionalized monolith for enantiomeric analysis was evaluated in terms of protein content, pH of running buffer, sample volume, buffer concentration, applied voltage, and capillary temperature. The relative standard deviation (%RSD) values of retention time (intraday <0.53, n = 10; interday <0.53, n = 10; column‐to‐column <0.70, n = 20; and batch‐to‐batch <0.80, n = 20) indicated satisfactory stability of these columns. No appreciable change was observed in retention and resolution for chiral recognition of (±)‐nefopam in 50 days with 100 injections. The proteolytic activity of this stationary phase was further characterized with bovine serum albumin as substrate for online protein digestion. As for monolithic immobilized enzyme reactor, successive protein injections confirmed both the operational stability and ability to reuse the bioreactor for at least 20 digestions. It implied that the affinity monolith used in this research opens a new path of exploring particularly versatile class of enzymes to develop enzyme‐modified affinity capillary monolith for enantioseparation.  相似文献   

5.
Porous zirconia monolith (ZM) modified with cellulose 3,5-dimethylphenylcarbamate (CDMPC) was used as chiral stationary phase to separate basic chiral compounds in capillary electrochromatography. The electroosmotic flow behavior of bare and CDMPC-modified zirconia monolithic (CDMPC-ZM) column was studied in ACN/phosphate buffer eluents of pH ranging from 2 to 12. The CDMPC-ZM column was evaluated by investigating the influences of pH, the type and composition of organic modifier of the eluent on enantioseparation. CEC separations at pH 9 provided the best resolutions for the analytes studied, which are better than those observed on CDMPC-modified silica monolithic columns under similar chromatographic conditions. No appreciable decline in retention and resolution factors after over 200 injections, and run-to-run and day-to-day repeatabilities of the column of less than 3% indicate the stability of the zirconia monolithic column in basic media.  相似文献   

6.
Wistuba D  Schurig V 《Electrophoresis》2000,21(18):4136-4158
Enantiomer separation by electrochromatography (CEC) can be performed in three modes: (i) open-tubular capillary electrochromatography (o-CEC), in which the chiral selector is physically adsorbed coated, and thermally immobilized or covalently attached to the internal capillary wall; (ii) packed capillary electrochromatography (p-CEC), in which the capillary is either filled with chiral modified silica particles or with an achiral packing material, and a chiral selector is added to the mobile phase; and (iii) monolithic (rod)-capillary electrochromatography (rod-CEC) in which the chiral stationary phase (CSP) consists of a single piece of porous solid. We present an overview on methods and new trends in the field of electrochromatographic enantiomer separation such as CEC with either nonaqueous mobile phases or stationary phases with incorporated permanent charges, or with packing beds consisting of nonporous silica particles or particles with very small internal diameters.  相似文献   

7.
Wang J  Wang X  Li J  Lü H  Lin X  Xie Z  Zhang Q 《色谱》2011,29(12):1222-1229
采用N-丙烯酰琥珀酰亚胺(NAS)为基质单体,乙二醇二甲基丙烯酸酯(EDMA)为交联剂,原位聚合制备聚(NAS-co-EDMA)毛细管整体柱,并通过化学键合法将自合成的纤维素-三(4-甲基苯甲酸酯)(CTMB)共价键合到整体柱上,制备用于快速手性分离的纤维素键合型手性整体柱.优化了整体柱制备和衍生化条件;通过对固定相红...  相似文献   

8.
The 3,5-dimethylphenylcarbamate derivatives of cellulose bearing 3-(triethoxysilyl)propyl residues were immobilized in a capillary format onto a monolithic silica support by intermolecular polycondensation of the triethoxysilyl groups. The resulting columns were used for chiral separations using capillary electrochromatography. The effects of the synthesizing solvent, the selector coating procedure, the chiral selector concentration onto the silica monolith and the mobile phase pH value, on the separation of enantiomers were studied. The column-to-column reproducibility and stability also were evaluated. A test set of 14 chiral substances, including acidic, neutral, bifunctional and basic compounds, was used to investigate the effects of the factors mentioned above. Twelve pairs of enantiomers showed enantioselectivity at some of the different conditions tested. The column-to-column repeatability was satisfactory, and the prepared columns were stable under the adopted analysis conditions.  相似文献   

9.
Dong X  Dong J  Ou J  Zhu Y  Zou H 《Electrophoresis》2007,28(15):2606-2612
Enantiomeric separations in CEC with the macrocyclic antibiotic vancomycin immobilized silica monolith as a chiral stationary phase are presented. The monolithic silica capillary columns were prepared by a sol-gel process in fused-silica capillaries with an inner diameter of 50 mum and subsequently in situ immobilization of vancomycin as a chiral selector by reductive amination. Enantioselectivity was obtained for eight pairs of enantiomers in nonaqueous polar organic or aqueous mobile phases and most of them were baseline-separated with high column efficiencies. It was observed that the organic modifier ratio (MeOH/ACN) in the polar organic mobile phase played a significant role in controlling the resolution and efficiency of the enantiomers. In enantiomeric separation of propranolol, repeatability for column efficiency and resolution in the nonaqueous mobile phase was given in terms of RSD values at 1.1 and 2.3% (n = 5) for run-to-run injections and 7.2 and 9.6% (n = 5) for column-to-column testing while repeatability for the separation of thalidomide in the aqueous mobile phase was given in terms of RSD values at 1.5, 2.8% and 6.1, 10.5%, respectively.  相似文献   

10.
In this work a new type of chiral monolith silica column was developed for the chiral separation by micro high-performance liquid chromatography (micro-HPLC). The chiral monolith column with a continuous skeleton and a large through-pore structure was prepared inside a capillary of 100 microm I.D. by a sol-gel process, and chemically modified with chiral selectors, such as L-phenylalaninamide, L-alaninamide and L-prolinamide, on the surface of the monolithic silica column. Based on the principle of ligand exchange, these chiral monolithic columns were successfully used for the separation of dansyl amino acid enantiomers, as well as hydroxy acid enantiomers by micro-HPLC. The chromatographic conditions, the enantioselectivity and the performance of columns are discussed.  相似文献   

11.
An affinity monolith based on silica and containing immobilized alpha(1)-acid glycoprotein (AGP) was developed and evaluated in terms of its binding, efficiency and selectivity in chiral separations. The results were compared with data obtained for the same protein when used as a chiral stationary phase with HPLC-grade silica particles or monoliths based on a copolymer of glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA). The surface coverage of AGP in the silica monolith was 18% higher than that obtained with silica particles and 61% higher than that measured for a GMA/EDMA monolith. The higher surface area of the silica monolith gave materials that contained 1.5- to 3.6-times more immobilized protein per unit volume when compared to silica particles or a GMA/EDMA monolith. The retention, efficiency and resolving power of the AGP silica monolith were evaluated by injecting two chiral analytes onto this column (i.e., R/S-warfarin and R/S-propranolol). In each case, the AGP silica monolith gave higher retention plus better resolution and efficiency than AGP columns containing silica particles or a GMA/EDMA monolith. The AGP silica monolith also gave lower back pressures and separation impedances than these other materials. It was concluded that silica monoliths can be valuable alternatives to silica particles or GMA/EDMA monoliths when used with AGP as a chiral stationary phase.  相似文献   

12.
Liu Z  Otsuka K  Terabe S  Motokawa M  Tanaka N 《Electrophoresis》2002,23(17):2973-2981
The physical adsorption method proposed previously has been successfully applied to a monolithic silica column. By virtue of the physical adsorption, a chiral stationary phase of avidin was prepared onto the silica monolith. The phase ratio of resulting stationary phase was evaluated with frontal analysis. The method proved to be comparable in phase ratio to the chemical bonding methods used in high-performance liquid chromatography (HPLC). Enantiomer separations were carried out in capillary electrochromatography (CEC) and capillary liquid chromatography (CLC) modes. Due to its larger phase ratio, the resulting column showed more powerful separation capability as compared to open-tubular CEC (OTCEC). Twelve chiral compounds were baseline-resolved. The resulting column showed high separation efficiency, with average theoretical plate numbers of 66 000/m for CLC and 122 000/m for CEC. Good reproducibility was observed, with RSD value less than 1.3% for retention time, retention factor and separation factor, and less than 6.6% for plate counts and resolution (n = 40). Fast separations were achieved with a short column. The test enantiomers were baseline-resolved within 4 min under CLC and CEC modes. In addition, field-enhanced sample injection (FESI) was coupled to CLC as well as CEC to improve the detection sensitivity.  相似文献   

13.
A new-type of sol-gel/organic hybrid composite material using gelatin or chitosan with tetramethoxysilane was developed for the bovine serum albumin (BSA)-encapsulated monolithic column for capillary electrochromatography (CEC). The composite monolith was used to immobilize BSA in a fused-silica capillary. The addition of gelatin and chitosan to the alkoxysilane enabled the enantioseparation of Trp. A very small amount of these polymers were effective for the enantioseparation. Especially, the monolithic column prepared from chitosan with tetramethoxysilane showed a high enantioselectivity for Trp enantiomers and the value (alpha' = t2/t1, t1: fast eluted enantiomer, t2: second eluted enantiomer) reached 1.15 on CEC mode. Furthermore, the composite materials exhibited a higher stability compared to the silica sol-gel column. These results showed that the sol-gel/organic hybrid composite was useful as a monolithic matrix for the BSA-encapsulated column for CEC.  相似文献   

14.
Liu Y  Heyden YV  Mangelings D 《Electrophoresis》2012,33(11):1613-1623
Chiral monolithic silica capillary columns were prepared by immobilization of amylose-3,5-dimethylphenylcarbamate (ADMPC) bearing a small fraction of 3-(triethoxysilyl)propyl residues through intermolecular polycondensation of the triethoxysilyl groups. The obtained columns were used for chiral separations in capillary electrochromatography (CEC). The effects of the silica monolith nature and the used chiral selector concentration on the resulting enantiomeric separations were investigated. Fifteen chiral compounds, including acidic, neutral, and basic substances were evaluated and twelve showed partial or baseline separation at some of the different conditions tested. These results demonstrated the promising applicability of ADMPC-immobilized monolithic silica columns in CEC enantioseparations, but also revealed the need for further improvements on the level of baseline separations and efficiencies.  相似文献   

15.
A chiral capillary monolithic column for enantiomer separation in capillary electrochromatography was prepared by coating cellulose tris(3,5‐dimethylphenylcarbamate) on porous glycidyl methacrylate‐co‐ethylene dimethacrylate monolith in capillary format grafted with chains of [2(methacryloyloxy)ethyl] trimethylammonium chloride. The surface modification of the monolith by the photografting of [2(methacryloyloxy)ethyl] trimethylammonium chloride monomer as well as the coating conditions of cellulose tris(3,5‐dimethylphenylcarbamate) onto the grafted monolithic scaffold were optimized to obtain a stable and reproducible chiral stationary phase for capillary electrochromatography. The effect of organic modifier (acetonitrile) in aqueous mobile phase for the enantiomer separation by capillary electrochromatography was also investigated. Several pairs of enantiomers including acidic, neutral, and basic analytes were tested and most of them were partially or completely resolved under aqueous mobile phases. The prepared monolithic chiral stationary phases exhibited a good stability, repeatability, and column‐to‐column reproducibility, with relative standard deviations below 11% in the studied electrochromatographic parameters.  相似文献   

16.
A new sol?Cgel protocol was designed and optimized to produce titanium-dioxide-based columns within confined geometries such as monolithic capillary columns and porous-layer open-tubular columns. A surface pre-treatment of the capillary enabled an efficient anchorage of the monolith to the silica capillary wall during the synthesis. The monolith was further synthesized from a solution containing titanium n-propoxide, hydrochloric acid, N-methylformamide, water, and poly(ethylene oxide) as pore template. The chromatographic application of capillary titania-based columns was demonstrated with the separation of a set of phosphorylated nucleotides as probe molecules using aqueous normal-phase liquid chromatography conditions. Capillary titania monoliths offered a compromise between the high permeability and the important loading capacity needed to potentially achieve miniaturized sample preparations. The specificity of the miniaturized titania monolithic support is illustrated with the specific enrichment of 5??-adenosine mono-phosphate. The monolithic column offered a ten times higher loading capacity of 5??-adenosine mono-phosphate compared with that of the capillary titania porous-layer open-tubular geometry.  相似文献   

17.
In-tube solid-phase microextraction (SPME) based on a poly(acrylamide-vinylpyridine-N,N'-methylene bisacrylamide) monolithic capillary was investigated and on-line coupled to HPLC for the determination of trace analytes in aqueous samples. The polymer monolith was conveniently synthesized in a fused silica capillary by in situ polymerization method. Several groups of analytes including non-steroidal anti-inflammatory drugs, phenols, non-peptide angiotensin II receptor antagonists and endocrine disrupting chemicals were extracted by the monolithic capillary. High extraction efficiency was achieved for the analytes investigated and great improvement of the limits of detection were obtained in comparison to that of direct chromatographic analysis and strong hydrophobic and ion-exchange interactions between the analytes and the polymer were confirmed. The newly developed monolithic capillary showed excellent reusability and high stability under extreme pH conditions during extraction. The possibility of applying the established method to water sample analysis was also demonstrated.  相似文献   

18.
In this paper, a poly(styrene-octadecene-divinylbenzene) (PS-OD-DVB) monolithic column was prepared in one step by introducing a C18 carbon chain as monomer. N,N-Dimethylformamide and decanol served as porogens to make a homogeneous polymerization mixture in a fused silica capillary (320 microm inner diameter). Its physical and chromatographic properties were compared with those of poly(styrene-divinylbenzene) (PS-DVB) monolithic column, which was also fabricated by in-situ polymerization in a fused silica capillary with the same inner diameter. Six standard proteins were used to evaluate the columns and their potential application for the separation of human hemoglobin was also discussed. It was shown that the PS-OD-DVB and PS-DVB monoliths appeared to have similar efficiency for rapid separation of six proteins within 3.5 min. The PS-OD-DVB monolith was found to have higher loading capacity and higher resolution for the separation of alpha and beta chains of hemoglobin because of the introduction of C18 carbon chains, and shows great potential for the separation of bio-macromolecules.  相似文献   

19.
丙基脲硅胶毛细管整体柱的制备及性能研究   总被引:1,自引:1,他引:0  
采用溶胶-凝胶技术在毛细管中原位合成硅胶整体柱,通过表面化学修饰技术制备了极性的丙基脲硅胶整体柱.对所制备的整体柱柱性能进行了评价,考察了极性物质在该整体柱上的保留行为,并对其可能的保留机理进行了探讨.研究表明,该柱在亲水作用电色谱模式下能有效分离苯酚类极性小分子化合物.  相似文献   

20.
Kang J  Wistuba D  Schurig V 《Electrophoresis》2002,23(7-8):1116-1120
A method for the preparation of a silica monolithic capillary electrochromatography (CEC) column for the separation of enantiomers has been developed. The porous silica monolith was fabricated inside a fused-silica capillary column by using the sol-gel process. After gelation for 24 h, hydrothermal treatment at 100 degrees C for 24 h was performed to prevent the sol-gel matrix from cracking. The prepared monolith was then coated with Chirasil-beta-Dex which represents a chiral polymer prepared by grafting permethyl-beta-cyclodextrin to polymethylsiloxane with an octamethylene spacer. Immobilization of Chirasil-beta-Dex was performed by heat treatment at 120 degrees C for 48 h to give a nonextractable coating. The column performance was evaluated by using racemic hexobarbital as a model compound. The efficiency of 9.2 x 10(4) theoretical plates/m for the first eluted enantiomer of hexobarbital was obtained at an optimal flow rate of the mobile phase. The effect of mobile phase composition on enantiomeric separation of hexobarbital was also investigated. The column proved to be stable for more than one hundreds of runs during a two-months period. The enantiomers of several neutral and negatively charged chiral compounds were baseline separated on this column.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏