首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper we present a device for the practical application of an ultrasonic critical-angle refractometry (UCRfr) technique. UCRfr is a technique for measuring the velocity of longitudinal, shear and Rayleight waves, developed to improve the traditional ultrasonic methods for measuring the stress level in materials by means of acousto-elasticity. The technique consists of relating the variations in wave propagation velocity to variations in the angle of refraction at the interface with a second medium. Variations in the angle of refraction are determined on the basis of delay in receiving of the same wave at two different points. The study deals with the measurements of velocity changes of longitudinal wave due to uniaxial stress. In the present work the effects of stress on aluminum and steel specimens have been studied. Experimentation has show the potential of the technique for stress measurement; on the other hand, when the applied stress is known, it allows the measurement of the acoustoelastic constants of longitudinal waves. As regards measuring variations in velocity induced by stress, using this method it is possible, with a suitable choice of the material the device is made of, to isolate the effects of stress on velocity from the possible effects of temperature.  相似文献   

2.
以非局部弹性理论为基础,采用欧拉-伯努利梁模型,考虑碳纳米管的小尺度效应,应用哈密顿原理获得了温度场作用下的输流悬臂单层碳纳米管(SWCNT)的振动控制方程以及边界条件,依靠微分变换法(DTM法)对此高阶偏微分方程进行求解,通过数值计算研究了温度场中悬臂单层输流碳纳米管的振动与颤振失稳问题。结果表明:管内流体流速、温度场中温度变化情况与小尺度参数都会对系统振动频率以及颤振失稳临界流速产生影响。其中,小尺度效应将会降低悬臂输流系统的稳定性,使系统更为柔软;而高温场与低温场对系统动态失稳的影响不同,低温场中随温度变化值的增加,系统的稳定性提高;高温场这一作用效果恰好与之相反。  相似文献   

3.
磁场对不同温度场中输流悬臂碳纳米管动态特性的影响   总被引:1,自引:0,他引:1  
本文在采用经典欧拉-伯努利梁模型的基础上,引入考虑小尺度效应的非局部弹性理论,着重研究不同温度场中输流悬臂单层碳纳米管系统(SWCNT)在外加纵向磁场作用下的颤振失稳问题。基于哈密顿原理获得了该流固耦合系统的振动控制方程及相应的边界条件,应用微分变换法(DTM法)求解此高阶偏微分方程,通过数值计算研究了不同温度场中施加纵向磁场对系统动力学特性的影响。结果表明:施加纵向磁场在不同温度场中都将增强输流悬臂碳纳米管的动态稳定性。然而,这种增强程度却与温度场的变化量有关,在不同温度变化量下,磁场对系统稳定性的增强程度有一个峰值,这意味着,实际应用中,为了提高这类流固耦合系统的动态稳定性,一味提高纵向磁场强度并不可取。  相似文献   

4.
An ultrasonic velocity profile (UVP) method has been successfully applied to the investigation of a liquid metal channel flow under the influence of an inhomogeneous magnetic field. Using velocity profiles obtained by the ultrasonic velocimeter and their numerical post processing, two-dimensional time-averaged flow maps were efficiently produced. A single transducer immersed directly into the working fluid was used in order to simplify alignment of measurement lines and avoid the undesirable refraction of the acoustic beam on the walls. An M-shaped flow and wake behind a magnetic obstacle were reconstructed as the patterns of shear and large-scale vortical flows.  相似文献   

5.
This paper presents the results of an investigation on the effects of measurement volume size on the mean velocity profile and the Reynolds stress for fully developed turbulent pipe flows. The study employs the ultrasonic velocity profile method, which is based on the ultrasonic Doppler method. The ultrasonic Doppler method offers many advantages over conventional methods for flow rate measurement in the nuclear power plant piping system. This method is capable of measuring the instantaneous velocity profile along the measuring line and is applicable for opaque liquids and opaque pipe wall materials. Furthermore, the method has the characteristic of being non-intrusive. Although it is applicable to various flow conditions, it requires a relatively large measurement volume. The measurement volume of the present method has a disk-shape determined by the effective diameter of the piezoelectric element and the number of the wave cycles of the ultrasonic pulse. Considering this disk-shaped measurement volume and expressing the time-averaged velocity in a truncated Taylor series expansion around the value at the center of the measuring control volume, the value of the velocity can be obtained. The results are then compared with the data obtained from DNS and LDA measurements. The result shows that the effect of the measurement volume size appears in the buffer region and viscous sublayer.  相似文献   

6.
In this paper, a Galerkin weighted residual finite element numerical solution method, with velocity material time derivative discretisation, is applied to solve for a classical fluid mechanics system of partial differential equations modelling two‐dimensional stationary incompressible Newtonian fluid flow. Classical examples of driven cavity laminar flow and laminar flow past a cylinder are presented. Numerical results are compared with data found in the literature. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

7.
《力学快报》2022,12(3):100342
The study of the natural convective flow of a fluid in the presence of an induced magnetic field has always been of considerable importance due to its many applications in various areas of science, technology, and industry, such as the operation of magnetohydrodynamic generators. This study addresses an analysis of exponential heat source and induced magnetic field on the second-class convection of Casson fluid in a microchannel. The flow is in a vertical microchannel organized by two vertical plates. The answer to governing equations has been grabbed for temperature field, induced magnetic field, and velocity via Akbari-Ganji's method (AGM). Nusselt number, skin friction coefficient, and current density are approximated. Graphs that describe the conclusion of influential physical variables on velocity, temperature, current density, induced magnetic field, and skin friction coefficient distributions are shown. Comparison of results with numerical method (Runge-Kutta-Fehlberg, RKF-45), homotopy perturbation method, and AGM confirms the accuracy of answers obtained with AGM.  相似文献   

8.
 The flow of isotropic and liquid crystalline (LC) hydroxypropylcellulose (HPC) aqueous solutions into an abrupt axisymmetric contraction has been quantitatively measured by pulsed-field-gradient NMR techniques. Steady-state axial velocity profiles, acquired upstream of the contraction, reveal a large contraction entry length for the LC solution. This entry flow field exists over an order of magnitude change in flow rate and is attributed to elasticity that is associated with polydomain liquid crystallinity. Pronounced, off-centerline velocity maxima (in an axisymmetric flow field) were present upstream of the contraction, in the entry flow region. Apparently, a more viscous and elastic core of fluid was present along the centerline; this fluid resisted elongational strain more than the fluid closer to the walls. Quantitative velocity profiles were extracted from displacement distributions and corrected for elongational dispersion. The isotropic solution velocity profiles matched those obtained from viscoelastic simulations using an approximate Doi-Edwards model, parameterized with independent rheological data. Received: 29 April 1999/Accepted: 30 August 1999  相似文献   

9.
Micro and nanotubes have found major application in fluidic systems as channels for conveying fluid. In some micro and nanofluidic applications such as drug delivery, a transverse magnetic field can be used to guide the fluid flow by generating an axial force in the flow direction. An important issue in the design of micro and nanofluidic systems is the structural vibration caused by the fluid flow. In the current study, we investigate the effect of transverse magnetic field on the vibration of cantilever micro and nanotubes conveying fluid by considering the small size effects. We couple the nonlocal Euler–Bernoulli beam model with Navier–Stokes theory to determine a fluid structure interaction (FSI) model for the vibration analysis of the system. We modify the FSI governing equation by driving a velocity correction factor to consider the effect of transverse magnetic field on the fluid flow’s pattern through the tube. Then, we use the Galerkin’s method to obtain the frequency diagrams for the instability analysis of the system. We show that the transverse magnetic field can have a substantial effect on the dynamics of tube conveying fluid by increasing the system’s natural frequencies and critical flow velocity which contributes to the flutter instability. We also discover that although the transverse magnetic field plays a crucial role on dynamics of microstructures, its effect on the dynamics of nanotubes is not significant and can be ignored.  相似文献   

10.
Particle streak velocimetry (PSV) has become one of the important branches of flow filed measurements. It extracts velocity information from particle trajectories captured by single frame long exposure images. Since the defocus of moving particle is inevitable during a long exposure time and under a large magnification, a novel three-dimensional (3D) velocity measurement method named defocusing particle streak velocimetry (DPSV) is proposed in this paper. On the one hand, an extension from two-dimensional (2D) to 3D velocity measurement with a monocular system is carried out. The depth information of the particle, which reflects the position in the third dimension, is indicated by the defocusing degree (characteristic parameter σ) of the particle images. The variation of σ along the trajectory is recognized by surface fitting of the gray value distribution of particle images, assuming that σ varies linearly along the trajectory. On the other hand, based on the linear fitting for the straight trajectory, an arc fitting model is developed for curved trajectories which are commonly captured in turbulent flow. The relationship between σ and the particle depth position z is experimentally calibrated using a LED light and a diaphragm. Finally, the DPSV method is verified in a submerged jet flow field as well as in a microchannel flow field to obtain the 3D velocity field with single monocular system.  相似文献   

11.
We present new examples of exactly averaged multi-dimensional equation of transport of a conservative solute in a time-dependent random flow velocity field. The functional approach and a technique for decoupling the correlations are used. In general, the averaged equation is non-local. We study the special cases where the averaged equation can be localized and reduced to a differential equation of finite-order, where the problem of evolution of the initial plume (Cauchy problem) can be solved exactly. We present in detail the results of the analyses of two cases of exactly averaged problems for Gaussian and telegraph random velocity with an identical exponential correlation function, which are informative and convenient models for continuous and discontinuous random functions. The problems in which the field has sources of solute and boundaries are also examined. We study the behavior of different initial plumes for all times (evolutions and convergence) and show the manner in which they approach the same asymptotic limit for two stochastic distributions of flow-velocity. A comparison between exact solutions and solutions derived by the method of perturbation is also discussed.  相似文献   

12.
Distributed Point Source Method (DPSM) is a semi-analytical technique that can be used to calculate the ultrasonic field (pressure, velocity and displacement fields in a fluid, or stress and displacement fields in a solid) generated by ultrasonic transducers. So far the technique has been used to model ultrasonic fields in homogeneous and multilayered fluid structures, and near a fluid–solid interface when a solid half-space is immersed in a fluid. In this paper, the method is extended to model the ultrasonic field generated in a homogeneous isotropic solid plate immersed in a fluid. The objective of this study is to model the generation of guided waves in a solid plate when ultrasonic beams from transducers of finite dimension strike the plate at different critical angles. DPSM results for a solid half-space problem are compared with the finite element predictions to show the superiority of the DPSM technique. The predicted results are also compared with the experimental visualization of the mode patterns of Lamb waves propagating in a glass plate obtained from stroboscopic photoelastic method. Experimental and theoretical results show good qualitative agreement. The DPSM technique is then applied to study the mode patterns in aluminum plates immersed in water.  相似文献   

13.

The lacunar-canalicular system (LCS) is acknowledged to directly participate in bone tissue remodeling. The fluid flow in the LCS is synergic driven by the pressure gradient and electric field loads due to the electro-mechanical properties of bone. In this paper, an idealized annulus Maxwell fluid flow model in bone canaliculus is established, and the analytical solutions of the fluid velocity, the fluid shear stress, and the fluid flow rate are obtained. The results of the fluid flow under pressure gradient driven (PGD), electric field driven (EFD), and pressure-electricity synergic driven (P-ESD) patterns are compared and discussed. The effects of the diameter of canaliculi and osteocyte processes are evaluated. The results show that the P-ESD pattern can combine the regulatory advantages of single PGD and EFD patterns, and the osteocyte process surface can feel a relatively uniform shear stress distribution. As the bone canalicular inner radius increases, the produced shear stress under the PGD or P-ESD pattern increases slightly but changes little under the EFD pattern. The increase in the viscosity makes the flow slow down but does not affect the fluid shear stress (FSS) on the canalicular inner wall and osteocyte process surface. The increase in the high-valent ions does not affect the flow velocity and the flow rate, but the FSS on the canalicular inner wall and osteocyte process surface increases linearly. In this study, the results show that the shear stress sensed by the osteocyte process under the P-ESD pattern can be regulated by changing the pressure gradient and the intensity of electric field, as well as the parameters of the annulus fluid and the canaliculus size, which is helpful for the osteocyte mechanical responses. The established model provides a basis for the study of the mechanisms of electro-mechanical signals stimulating bone tissue (cells) growth.

  相似文献   

14.
Operational state of many miniaturized devices deals with flow field in microchannels. Pressure-driven flow (PDF) and electroosmotic flow (EOF) can be recognized as the two most important types of the flow field in such channels. EOF has many advantages in comparison with PDF, such as being vibration free and not requiring any external mechanical pumps or moving parts. However, the disadvantages of this type of flow such as Joule heating, electrophoresis demixing, and not being suitable for mobile devices must be taken into consideration carefully. By using mixed electroosmotic/pressure-driven flow, the role of EOF in producing desired velocity profile will be reduced. In this way, the advantages of EOF can be exploited, and its disadvantages can be prevented. Induced pressure gradient can be utilized in order to control the separation in the system. Furthermore, in many complicated geometries such as T-shape microchannels, turns may induce pressure gradient to the electroosmotic velocity. While analytical formulas are completely essential for analysis and control of any industrial and laboratory microdevices, lack of such formulas in the literature for solving Poisson–Boltzmann equation and predicting electroosmotic velocity field in rectangular domains is evident. In the present study, first a novel method is proposed to solve Poisson–Boltzmann equation (PBE). Subsequently, this solution is utilized to find the electroosmotic and the mixed electroosmotic/pressure-driven velocity profile in a rectangular domain of the microchannels. To demonstrate the accuracy of the presented analytical method in solving PBE and finding electroosmotic velocity, a general nondimensional example is analyzed, and the results are compared with the solution of boundary element method. Additionally, the effects of different nondimensional parameters and also aspect ratio of channels on the electroosmotic part of the flow field will be investigated.  相似文献   

15.
This work concerns the analysis of experimental instantaneous fluid levels and three-component fluid velocity measurements in a stationary flow field generated by a Crump weir in a laboratory flume using an ultrasonic distance sensor and a three-probe arrangement of an ultrasonic Doppler velocity profiler. The tests are characterised by different and increasing Froude numbers (Fr = 0.10–0.38), with the free surface of the fluid ranging from flat (low Froude number) to almost aerated (high Froude number). The statistics of the free surface are computed, and the relevant length and velocity scales are measured. A free-surface boundary layer was detected having a thickness proportional to the root mean square of the free-surface height series and with a velocity scale that related well to the free-surface elevation time gradient. The mean velocity profiles are presented. There are many indicators that a specific regime occurs with an optimal tuning between free surface and turbulence. In this regime, the length scales are raised.  相似文献   

16.
微分求积法分析具有弹性支承输液管的临界流速   总被引:12,自引:0,他引:12  
将微分求积方法推广到分析输液管的临界流速,这是一个新的尝试,与其它数值方法相比,该法极易处理具有弹性边界的输液管,另外,由于避免了一系列数值积分的计算,且最终须求解的方程的阶数较低,故计算量较少,精度令人满意,在此基础上,本文还研究了各参数对临界流速的影响。  相似文献   

17.
黄湛  张淼  程攀  王宏伟 《实验力学》2016,(5):673-682
光流测量技术作为一种新的空气动力学实验技术,以其像素级分辨率的矢量场测量优势获得广泛的应用。光流测量技术使用光流约束方程,配合平滑限定条件,可以进行速度场测量,获得高分辨率的全局矢量场。本文首先通过研究积分最小化光流测速理论和算法,采用C++编写光流速度测量程序;然后通过三种典型的人工位移图像对光流计算程序进行了验证,并将结果和标准位移分布进行比对分析,以指导如何在实际应用中获得高精度光流速度场;最后进行小型风洞后向台阶实验,利用高速相机拍摄示踪粒子图像,使用光流计算程序获得速度矢量场,同采用互相关算法的粒子图像测速计算结果相比较,体现出光流计算方法像素级分辨率的矢量场测量优势。  相似文献   

18.
The non-Newtonian blood flow, together with magnetic particles in a stenosed artery, is studied using a magneto-hydrodynamic approach. The wall slip condition is also considered. Approximate solutions are obtained in series forms under the assumption that the Womersley frequency parameter has small values. Using an integral transform method, analytical solutions for any values of the Womersley parameter are obtained.Numerical simulations are performed using MATHCAD to study the influence of stenosis and magnetic field on the flow parameters. When entering the stenosed area, blood velocity increases slightly, but increases considerably and reaches its maximum value in the stenosis throat. It is concluded that the magnitude of axial velocity varies considerably when the applied magnetic field is strong. The magnitude of maximum fluid velocity is high in the case of weak magnetic fields. This is due to the Lorentz's force that opposes motion of an electrically conducting fluid. The effect of externally transverse magnetic field is to decelerate the flow of blood. The shear stress consistently decreases in the presence of a magnetic field with increasing intensity.  相似文献   

19.
Four examples of self-similar flows of a viscous fluid are considered: separated flow over an expanding plate immersed in an unbounded unsteady viscous flow, the evolution of the velocity field induced by a vortex-source, the flow near an unsteadily moving permeable flat plate, and the flow near an unsteadily rotating disc. For the first example, a numerical solution is constructed. For the next two examples, an analytical solution is found, while the solution of the last problem is reduced to a system of ordinary differential equations.  相似文献   

20.
The objective of the present study is to investigate the effect of flow parameters on the free convection and mass transfer of an unsteady magnetohydrodynamic flow of an electrically conducting, viscous, and incompressible fluid past an infinite vertical porous plate under oscillatory suction velocity and thermal radiation. The Dufour (diffusion thermo) and Soret (thermal diffusion) effects are taken into account. The problem is solved numerically using the finite element method for the velocity, the temperature, and the concentration field. The expression for the skin friction, the rate of heat and mass transfer is obtained. The results are presented numerically through graphs and tables for the externally cooled plate (Gr 〉 0) and the externally heated plate (Gr 〈 0) to observe the effects of various parameters encountered in the equations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号