首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 668 毫秒
1.
Huang MK  Liu C  Huang SD 《The Analyst》2002,127(9):1203-1206
A fiber-stable, repeatable and highly sensitive headspace solid-phase microextraction (HS-SPME) method was developed for the analysis of methamphetamine (MA) and amphetamine (AM) in urine using gas chromatography-mass spectrometry (GC-MS) in the selected ion monitoring mode. For sample preparation, the test specimen was placed in a 7 ml vial along with the additives (KOH and NaCl) and the internal standards (d8-MA and d8-AM), a glass insert containing heptafluorobutyric anhydride (HFBA) and heptafluorobutyric chloride (HFBCl) as derivatizing reagents was inserted into the vial, the vial was then sealed tightly. A SPME device with a 100 microm polydimethylsiloxane fiber was inserted into the vial and the fiber was exposed to the headspace in the insert, then the vial was heated and stirred at 100 degrees C and 600 rpm for 20 min for evaporation/adsorption/derivatization. The vaporized analytes (AM and MA) in the vial diffused into the glass insert though the holes on the insert, they absorbed onto the fiber, and then interacted with the vapor of the derivatizing reagent. Some of the analytes in the headspace of the glass insert may react with the vapor of the derivatizing reagent first, and then adsorb onto the fiber. The needle was finally removed and inserted into the injection port to desorb the analytes with the fiber exposed to the liner of the GC-MS system for analysis. By combining HFBCl and HFBA as derivatizing reagents and placing them in an insert, the HS-SPME method achieves high sensitivity for the analysis of AM and MA. Correlation coefficients derived from typical calibration curves in the 1.0-1700 ng ml(-1) range are 0.998 for MA and 0.994 for AM. The limits of detection and the limits of quantitation using a sample size of 1 ml are 0.3 and 1.0 ng ml(-1), respectively, for both MA and AM in urine specimens. Because the water hydrolysis of derivatizing reagent is much faster than the acylation reaction of the primary and secondary amines with the derivatizing reagent, the amphetamines cannot be acylated effectively over heated aqueous solution, and therefore this study provides a new acylation design in moisture surroundings. The proposed process also simplifies the procedure for urine sample preparation, and makes the automation of SPME possible.  相似文献   

2.
Single-drop microextraction (SDME), an emerging miniaturised extraction technique, was for the first time combined with multiple headspace extraction (MHE) to enable the quantitative determination of volatiles in solid matrixes by SDME technique. The concept of multiple headspace single-drop microextraction (MHS-SDME) was then applied for quantitative determination of styrene in polystyrene (PS) samples. Good linearity for the multiple headspace extraction was obtained when the migration of styrene was facilitated by grinding the samples and incubating them for 1 h at 150 degrees C prior the first extraction. Two microlitres of butyl acetate was used as the single-drop microextraction solvent and the extraction time was 5 min per cycle. The relative standard deviation (RSD) for single-drop microextraction of styrene standard at n=6 was 7.6%. Linearity was shown for styrene concentrations between 0.005 and 0.75 microg/ml (R2=0.999). This corresponds to total amount of styrene between 0.1 and 15 microg. The limit of quantitation for styrene standard at S/N 10 was 0.005 microg/ml. The developed method was validated against and showed good agreement with an earlier reported dissolution-precipitation method.  相似文献   

3.
A method for the determination of trace amounts of the herbicide oxadiazon was developed using headspace solid-phase microextraction (HS-SPME), gas chromatography-mass spectrometry (GC-MS) and selected ion monitoring. It was applied to determine oxadiazon in ground water, agricultural soil, must, wine and human urine samples. To determine oxadiazon in liquid samples, a response surface methodology generated with a Doehlert design was applied to optimize the HS-SPME conditions using a 100 microm polydimethylsiloxane fibre. For the analysis of soil samples, they were mixed with water and the SPME fibre suspended in the headspace above the slurry. Ground water, human urine and must show linear concentration range of application of 0.5-50 ng ml(-1)' with detection limits < or =0.02 ng ml(-1). HS-SPME-GC-MS analysis yielded good reproducibility (RSD values between 6.5 and 13.5%). The method validation was completed with spiked matrix samples. The developed analytical procedure is solvent free, cost effective and fast.  相似文献   

4.
A rapid and sensitive method for the simultaneous confirmatory analysis of three forensic most relevant cannabinoids, Delta(9)-tetrahydrocannabinol (THC), 11-hydroxy-Delta(9)-tetrahydrocannabinol (11-OH-THC) and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH), by means of high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) in human plasma was developed and fully validated. Sample clean-up was performed by automated silica-based solid-phase extraction and the separation was carried out using a PhenylHexyl column (50 x 2 mm i.d., 3 micro m) and acetonitrile-5 mM ammonium acetate gradient elution. Data were acquired with an API 3000 LC/MS/MS system equipped with a turboionspray interface and triple quadrupole mass analyzer using positive electrospray ionization and multiple reaction monitoring. Two MS/MS transitions for each substance were monitored and deuterated analogues of analytes were used as internal standards for quantitation. The limit of quantitation was 0.8 ng ml(-1) for THC, 0.8 ng ml(-1) for 11-OH-THC and 4.3 ng ml(-1) for THC-COOH and linearity with a correlation coefficient r(2) = 0.999 was achieved up to 100 ng ml(-1) for THC and 11-OH-THC and 500 ng ml(-1) for THC-COOH. The limits of detection were 0.2 ng ml(-1) for THC, 0.2 ng ml(-1) for 11-OH-THC and 1.6 ng ml(-1) for THC-COOH. The developed LC/MS/MS method was also successfully used for the determination of THC-COOH-glucuronide, the phase II metabolite of THC-COOH.  相似文献   

5.
Electro membrane extraction as a new microextraction method was applied for the extraction of amlodipine (AM) enantiomers from biological samples. During the extraction time of 15 min, AM enantiomers migrated from a 3 mL sample solution, through a supported liquid membrane into a 20 μL acceptor solution presented inside the lumen of the hollow fiber. The driving force of the extraction was 200 V potential, with the negative electrode in the acceptor solution and the positive electrode in the sample solution. 2-Nitro phenyl octylether was used as the supported liquid membrane. Using 10 mM HCl as background electrolyte in the sample and acceptor solution, enrichment up to 124 times was achieved. Then, the extract was analyzed using CD modified CE method for separation of AM enantiomers. Best results were achieved using a phosphate running buffer (100 mM, pH 2.0) containing 5 mM hydroxypropyl-α-CD. The range of quantitation for both enantiomers was 10-500 ng/mL. Intra- and interday RSD (n=6) were less than 14%. The limits of quantitation and detection for both enantiomers were 10 and 3 ng/mL respectively. Finally, this procedure was applied to determine the concentration of AM enantiomers in plasma and urine samples.  相似文献   

6.
A new sample pretreatment technique, ultrasound-assisted headspace liquid-phase microextraction was developed as mentioned in this paper. In the technique, the volatile analytes were headspace extracted into a small drop of solvent, which suspended on the bottom of a cone-shaped PCR tube instead of the needle tip of a microsyringe. More solvent could be suspended in the PCR tube than microsyringe due to the larger interfacial tension, thus the analysis sensitivity was significantly improved with the increase of the extractant volume. Moreover, ultrasound-assisted extraction and independent controlling temperature of the extractant and the sample were performed to enhance the extraction efficiency. Following the extraction, the solvent-loaded sample was analyzed by high-performance liquid chromatography. Chlorophenols (2-chlorophenol, 2,4-dichlorophenol and 2,6-dichlorophenol) were chosen as model analytes to investigate the feasibility of the method. The experimental conditions related to the extraction efficiency were systematically studied. Under the optimum experimental conditions, the detection limit (S/N=3), intra- and inter-day RSD were 6 ng mL(-1), 4.6%, 3.9% for 2-chlorophenol, 12 ng mL(-1), 2.4%, 8.8% for 2,4-dichlorophenol and 23 ng mL(-1), 3.3%, 5.3% for 2,6-dichlorophenol, respectively. The proposed method was successfully applied to determine chlorophenols in real aqueous samples. Good recoveries ranging from 84.6% to 100.7% were obtained. In addition, the extraction efficiency of our method and the conventional headspace liquid-phase microextraction were compared; the extraction efficiency of the former was about 21 times higher than that of the latter. The results demonstrated that the proposed method is a promising sample pretreatment approach, its advantages over the conventional headspace liquid-phase microextraction include simple setup, ease of operation, rapidness, sensitivity, precision and no cross-contamination. The method is very suitable for the analysis of trace volatile and semivolatile pollutants in real aqueous sample.  相似文献   

7.
A simple, sensitive and rapid method for the determination of diisopropylfluorophosphate (DFP) in rat plasma and brain tissue using headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) is presented. A 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was selected for sampling. The main parameters affecting the SPME process such as extraction and desorption temperature, extraction and desorption time, salt addition, and fiber preheating time were optimized in each matrix to enhance the extraction efficiency of the method. The lower limits of quantitation for DFP in plasma and brain tissue were 1 ng/mL and 3 ng/g, respectively. The method showed good linearity over the range from 1-100 ng/mL in plasma and 3-300 ng/g in brain tissue with correlation coefficient (R(2)) values higher than 0.995. The precision and accuracy for intra-day and inter-day were less than 10%. The relative recoveries in plasma and brain for DFP were greater than 50%. Stability tests including autosampler and freeze and thaw were also investigated. This validated method was successfully applied to study the neurobehavioral effects of low-level organophosphate exposures. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

8.
In this work, for the first time, gas chromatography-mass spectrometry (GC-MS) following headspace single-drop microextraction (HS-SDME) and simultaneous derivatization was developed for fast determination of short-chain aliphatic amines (SCAAs) in water samples. In the proposed method, SCAAs in water samples were headspace extracted and concentrated by suspending a microdrop of solvent, and SCAAs extracted in the microdrop of solvent were simultaneously and rapidly reacted with pentafluorobenzaldehyde (PFBAY). The formed SCAA derivatives were analyzed by GC-MS. The HS-SDME parameters of solvent selection, solvent volume, sample temperature, extraction time and stirring rate were studied, and the method linearity, precision and detection limits, were also studied. The results show that the proposed method provided good linearity (R(2)>0.99, 5.0-500 ng/ml), low detection limit (0.6-1.1 ng/ml), and good precision (RSD value less than 10%). The proposed method was further tested by its application to quantitative analysis of SCAAs in four wastewater samples. The experiment results have demonstrated that GC-MS following HS-SDME and simultaneous derivatization is a simple, rapid and low-cost method for the determination of SCAAs in water samples.  相似文献   

9.
Liquid-phase microextraction (LPME) has been proved to be a fast, inexpensive and effective sample pre-treatment technique for the analyses of pesticides and many other compounds. In this investigation, a new headspace microextraction technique, dynamic headspace time-extended helix liquid-phase microextraction (DHS-TEH-LPME), is presented. In this work, use of a solvent cooling system, permits the temperature of the extraction solvent to be lowered. Lowering the temperature of the extraction solvent not only reduces solvent loss but also extends the feasible extraction time, thereby improving extraction efficiency. Use of a larger volume of the solvent not only extends the feasible extraction time but also, after extraction, leaves a larger volume to be directly injected into the gas chromatography (GC) to increase extraction efficiency and instrument signal. The DHS-TEH-LPME technique was used to extract six organochlorine pesticides (OCPs) from 110 ml water samples that had been spiked with the analytes at ng/l levels, and stirred for 60 min. The proposed method attained enrichments up to 2121 fold. The effects of extraction solvent identity, sample agitation, extraction time, extraction temperature, and salt concentration on extraction performance were also investigated. The method detection limits (MDLs) varied from 0.2 to 25 ng/l. The calibration curves were linear for at least 2 orders of magnitude with R2 ≧ 0.996. Relative recoveries in river water were more than 86%.  相似文献   

10.
Hydrodistillation (HD) coupled with headspace single-drop microextraction by using ionic liquid (IL) as the extraction solvent, followed by gas chromatography analysis technique, was successfully developed to determine the volatile and semivolatile compounds in seeds of Cuminum cyminum L. In the proposed method, a 1.5-??L microdrop of 1-octyl-3-methylimidazolium hexafluorophosphate, working as the extraction solvent was suspended in the headspace of a 50-mL round-bottom sample flask. After extracting for 30?min, both IL and target analytes were injected into the gas chromatographic system by thermal desorption for 5?s under 240?°C. Then, the IL was retracted back to the microsyringe. Thus, the capillary column should not be contaminated and a clean chromatogram was obtained. The parameters affecting extraction performance were investigated and optimized. The extraction efficiency of the proposed method was compared with that of HD, which is a standard extraction method. The contents of constituents in the extract obtained by the proposed method were close to those obtained by HD. It seems to be an environmentally friendly, time-saving, high efficiency and low solvent consumption technique and would be useful, especially for aromatic plants analysis.  相似文献   

11.
A method was developed and fully validated for the quantitation of prazepam and its major metabolites, oxazepam and nordiazepam, in human plasma. Sample pretreatment was achieved by solid-phase extraction using Oasis HLB cartridges. The extracts were analysed by high-performance liquid chromatography (HPLC) coupled with single-quadrupole mass spectrometry (MS) with an electrospray ionization interface. The MS system was operated in the selected ion monitoring mode. HPLC was performed isocratically on a reversed-phase XTerra MS C18 analytical column (150 x 3.0 mm i.d., particle size 5 microm). Diazepam was used as the internal standard for quantitation. The assay was linear over a concentration range of 5.0-1000 ng ml(-1) for all compounds analyzed. The limit of quantitation was 5 ng ml(-1) for all compounds. Quality control samples (5, 10, 300 and 1000 ng ml(-1)) in five replicates from three different runs of analysis demonstrated an intra-assay precision (CV) of < or = 9.1%, an inter-assay precision of < or = 6.0% and an overall accuracy (relative error) of < 4.6%. The method can be used to quantify prazepam and its metabolites in human plasma covering a variety of pharmacokinetic or bioequivalence studies.  相似文献   

12.
In this study a dispersive liquid-liquid microextraction (DLLME) method based on the dispersion of an extraction solvent into aqueous phase in the presence of a dispersive solvent was investigated for the preconcentration of Cu(2+) ions. 8-Hydroxy quinoline was used as a chelating agent prior to extraction. Flame atomic absorption spectrometry using an acetylene-air flame was used for quantitation of the analyte after preconcentration. The effect of various experimental parameters on the extraction was investigated using two optimization methods, one variable at a time and central composite design. The experimental design was performed at five levels of the operating parameters. Nearly the same results for optimization were obtained using both methods: sample size 5 mL; volume of dispersive solvent 1.5 mL; dispersive solvent methanol; extracting solvent chloroform; extracting solvent volume 250 microL; 8-hydroxy quinoline concentration and salt amount do not affect significantly the extraction. Under the optimum conditions the calibration graph was linear over the range 50-2000 muicro L(-1). The relative standard deviation was 5.1% for six repeated determinations at a concentration of 500 microg L(-1). The limit of detection (S/N=3) was 3 microg L(-1).  相似文献   

13.
A headspace solvent microextraction method was developed for the trace determination of geosmin, an odorant compound, in water samples. After performing the extraction by a microdrop of an organic solvent, the microdrop was introduced directly into a GC-MS injection port. One-at-the-time optimization strategy was applied to investigate and optimize some important extraction parameters such as type of solvent, drop volume, temperature, stirring rate, ionic strength, sample volume, and extraction time. The analytical data exhibited an RSD of less than 5% (n = 5), a linear calibration range of 5-900 ng/L (r2 > 0.998), and a detection limit of 0.8 and 3.3 ng/L using two different sets of selected ions. The proposed method was successfully applied to the extraction and determination of geosmin in the spiked real water sample and reasonable recovery was achieved.  相似文献   

14.
Abstract

A rapid method for the simultaneous quantitation of the H2-receptor antagonist drugs cimetidine and ranitidine in human plasma by isocratic ion-pair reverse-phase HPLC is described. The method involves a simple organic extraction step of the alkalinized plasma containing added internal standard followed by back extraction of the extract with dilute acetic acid and subsequent analysis of the aqueous acidic phase on a reverse-phase (C18) column. The eluting solvent was acetonitrile-water (20:80 v/v) containing 0.005 mole/litre octanesulphonic acid and was monitored at 229 nm. The run time for the assay was 12.5 minutes, with a detection limit for cimetidine of 50 ng/m1/(0.2 μmole/1) and that for ranitidine was 20 ng/ml (0.06 umole/1).  相似文献   

15.
The development and validation of an assay for the determination of paclitaxel in human plasma, human brain tumor tissue, mouse plasma and mouse brain tumor tissue is described. Paclitaxel was extracted from the matrices using liquid-liquid extraction with tert-butyl methyl ether, followed by chromatographic analysis using an alkaline eluent. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicate that calibration standards in human plasma can be used to quantify paclitaxel in all tested matrices. In human samples, the validated range for paclitaxel was from 0.25-1000 ng ml(-1) using 200 microl plasma aliquots and from 5 to 5000 ng g(-1) using 50 microl tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma). In mice, the ranges were 1-1000 ng ml(-1) and 5-5000 ng g(-1) using 50 microl of mouse plasma and 50 microl of tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma), respectively. The method can be applied to studies generating only small sample volumes (e.g. mouse plasma and tumor tissue), but also to studies in human plasma requiring a lower limit of quantitation. The assay was applied successfully to several studies with both human and mouse samples.  相似文献   

16.
Yang  Jinjuan  Wei  Hongmin  Yu  Cui  Shi  Yuhua  Zhang  Hanqi 《Chromatographia》2012,75(23):1435-1443

Hydrodistillation (HD) coupled with headspace single-drop microextraction by using ionic liquid (IL) as the extraction solvent, followed by gas chromatography analysis technique, was successfully developed to determine the volatile and semivolatile compounds in seeds of Cuminum cyminum L. In the proposed method, a 1.5-μL microdrop of 1-octyl-3-methylimidazolium hexafluorophosphate, working as the extraction solvent was suspended in the headspace of a 50-mL round-bottom sample flask. After extracting for 30 min, both IL and target analytes were injected into the gas chromatographic system by thermal desorption for 5 s under 240 °C. Then, the IL was retracted back to the microsyringe. Thus, the capillary column should not be contaminated and a clean chromatogram was obtained. The parameters affecting extraction performance were investigated and optimized. The extraction efficiency of the proposed method was compared with that of HD, which is a standard extraction method. The contents of constituents in the extract obtained by the proposed method were close to those obtained by HD. It seems to be an environmentally friendly, time-saving, high efficiency and low solvent consumption technique and would be useful, especially for aromatic plants analysis.

  相似文献   

17.
Recently, we demonstrated for the first time liquid-phase microextraction (LPME) of polar drugs based on carrier mediated transport. In this new extraction technique, selected analytes were extracted as ion-pairs from small volumes of biological samples, through a thin layer of a water immiscible organic solvent immobilised in the pores of a porous hollow fibre (liquid membrane), and into a microl volume of an acidic aqueous acceptor solution placed inside the lumen of the hollow fibre. In the current paper, this new extraction technique was combined with liquid chromatography-mass spectrometry (LC-MS) for the first time. Carrier mediated LPME was evaluated for several new model drugs (0.01 相似文献   

18.
A simple and novel speciation method for the determination of volatile organic compounds of selenium (dimethylselenide (DMSe) and dimethyldiselenide (DMDSe) has been developed using a headspace hollow fiber protected liquid-phase microextraction (HS-HF-LPME) combined with capillary gas chromatography-mass spectrometry (GC-MS). The organic solvent impregnated in the pores and filled inside the porous hollow fiber membrane was used as an extraction interface in the HS-HF-LPME of the compounds. The effect of different variables on the extraction efficiency was studied simultaneously using an experimental design. The variables of interest in the HS-HF-LPME were sample volume, extraction time, temperature of sample solution, ionic strength, stirring rate and dwelling time. A Plackett-Burman design was performed for screening in order to determine the significant variables affecting the extraction efficiency. Then, the significant factors were optimized by a Box-Behnken design (BBD) and the response surface equations were derived. Under optimum conditions, preconcentration factors up to 1250 and 1170 were achieved for DMSe and DMDSe respectively. The detection limit and relative standard deviation (RSD) (n=5, c=50 μg L(-1)) for DMSe were 65 ng L(-1) and 4.8%, respectively. They were also obtained for DMDSe as 57 ng L(-1) and 3.9%, respectively. The developed technique was found to be applicable to spiked environmental and biological samples.  相似文献   

19.
A new method was developed and fully validated for the quantitation of benazepril, benazeprilat and hydrochlorothiazide in human plasma. Sample pretreatment was achieved by solid-phase extraction (SPE) using Oasis HLB cartridges. The extracts were analysed by high-performance liquid chromatography (HPLC) coupled to a single-quadrupole mass spectrometer (MS) with an electrospray ionization interface. The MS system was operated in selected ion monitoring (SIM) modes. HPLC was performed isocratically on a reversed-phase porous graphitized carbon (PGC) analytical column (2.1 x 125.0 mm i.d., particle size 5 microm). The mobile phase consisted of 55% acetonitrile in water containing 0.3% v/v formic acid and pumped at a flow rate of 0.15 ml min(-1). Chlorthalidone was used as the internal standard (IS) for quantitation. The assay was linear over a concentration range of 5.0-500 ng ml(-1) for all the compounds analysed, with a limit of quantitation of 5 ng ml(-1) for all the compounds. Quality control (QC) samples (5, 10, 100 and 500 ng ml(-1)) in five replicates from three different runs of analyses demonstrated intra-assay precision (coefficient of variation (CV) < or =14.6%), inter-assay precision (CV < or = 5.6%) and overall accuracy (relative error less than -8.0%). The method can be used to quantify benazepril, benazeprilat and hydrochlorothiazide in human plasma, covering a variety of pharmacokinetic or bioequivalence studies.  相似文献   

20.
The hyphenated technique namely microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) was developed and studied for the simultaneous extraction/enrichment of polychlorinated biphenyls (PCBs) in aqueous samples prior to the quantification by gas chromatography (GC). The PCBs in aqueous media are extracted onto a solid-phase micro fibre via the headspace with the aid of microwave irradiation. The optimum conditions for obtaining extraction efficiency, such as the extraction time, addition of salts, addition of methanol, ratio of sample to headspace volume, and the desorption parameters were investigated. Experimental results indicated that the proposed MA-HS-SPME method attained the best extraction efficiency under the optimized conditions, i.e., irradiation of extraction solution (20 ml aqueous sample in 40 ml headspace vial with no additions of salt and methanol) under 30 W microwave power for 15 cycles (1 min power on and 3 min power off of each cycle). Desorption at 270 degrees C for 3 min provided the best detection results. The detection limit obtained were between 0.27 and 1.34 ng/l. The correlation coefficient for the linear dynamic range from 1 to 80 ng/l exceeded 0.99 for 18 PCBs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号