首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A capillary electrophoresis-mass spectrometry (CE-MS) method using sheath liquid electrospray ionization interfacing was studied and optimized for the analysis of intact basic proteins. To prevent protein adsorption, capillaries with a noncovalent positively charged coating were utilized. Capillaries were coated by subsequent rinsing with solutions of Polybrene, dextran sulfate and Polybrene. The coating proved to be fully compatible with MS detection, causing no background signals and ionization suppression. The composition of the sheath liquid and BGE was optimized using the model proteins α-chymotrypsinogen A, ribonuclease A, lysozyme and cytochrome c. A sheath liquid of isopropanol-water-acetic acid (75:25:0.1, v/v/v) at 2 μL min−1 resulted in optimal signal intensities for most proteins, but caused dissociation of the heme group of cytochrome c. Optimum protein responses were obtained with a BGE of 50 mM acetic acid (pH 3.0), which allowed a baseline separation of the test protein mixture. Several minor impurities present in the mixture could be detected and provisionally identified using accurate mass and a protein modification database. The selectivity of the CE-MS system was investigated by the analysis of acetylated lysozyme. Eight highly related species, identified as non-acetylated lysozyme and lysozyme acetylated in various degrees, could be distinguished. The CE-MS system showed good reproducibility yielding interday (three weeks period) RSDs for migration time and peak area within 2% and 10%, respectively. With the CE-MS system, determination coefficients (R2) for protein concentration and peak area were higher than 0.996, whereas detection limits were between 11 and 19 nM.  相似文献   

2.
In this work, a new physically adsorbed coating for capillary electrophoresis (CE) is presented. The coating is based on a N,N-dimethylacrylamide-ethylpyrrolidine methacrylate (DMA-EPyM) copolymer synthesized in our laboratory. The capillary coating is simple and easy to obtain as only requires flushing the capillary with a polymer aqueous solution for 2 min. It is shown that by using these coated capillaries the electrostatic adsorption of a group of basic proteins onto the capillary wall is significantly reduced allowing their analysis by CE. Moreover, the DMA-EPyM coating provides reproducible separations of the basic proteins with RSD values for migration times lower than 0.75% for the same day (n = 5) and lower than 3.90% for three different days (n = 15). Interestingly, the electrical charge of the coated capillary wall can be modulated by varying the pH of the running buffer which makes possible the analysis of basic and acidic proteins in the same capillary. The usefulness of this coating is further demonstrated via the reproducible separation of whey (i.e. acidic) proteins from raw milk. The coating protocol should be compatible with both CE in microchips and CE-MS of different types of proteins.  相似文献   

3.
The performance of a prototype porous tip sprayer for sheathless capillary electrophoresis-mass spectrometry (CE-MS) of intact proteins was studied. Capillaries with a porous tip were inserted in a stainless steel needle filled with static conductive liquid and installed in a conventional electrospray ionization (ESI) source. Using a BGE of 100 mM acetic acid (pH 3.1) and a positively charged capillary coating, a highly reproducible and efficient separation of four model proteins (insulin, carbonic anhydrase II, ribonuclease A and lysozyme) was obtained. The protein mass spectra were of good quality allowing reliable mass determination of the proteins and some of their impurities. Sheath-liquid CE-MS using the same porous tip capillary and an isopropanol-water-acetic acid sheath liquid showed slightly lower to similar analyte responses. However, as noise levels increased with sheath-liquid CE-MS, detection limits were improved by a factor 6.5-20 with sheathless CE-MS. The analyte response in sheathless CE-MS could be enhanced using a nanoESI source and adding 5% isopropanol to the BGE, leading to improved detection limits by 50-fold to 140-fold as compared to sheath liquid interfacing using the same capillary - equivalent to sub-nM detection limits for three out of four proteins. Clearly, the sheathless porous tip sprayer provides high sensitivity CE-MS of intact proteins.  相似文献   

4.
研究了新型吡咯烷酮类离子液体N-辛基-2-吡咯烷酮甲磺酸盐([NOP]~+CH_3SO~-_3)作为毛细管动态涂敷试剂时,对3种常见碱性蛋白质标准物质(溶菌酶、细胞色素c、α-胰凝乳蛋白酶原)的分离情况。系统考察了缓冲溶液类型、缓冲溶液p H值、离子液体添加剂浓度对分离效果的影响。结果表明,该动态涂敷方法简单快速,3种碱性蛋白质在8min内实现了高效分离,理论塔板数分别为2.9×10~5、5.8×10~5、1.8×10~4N/m。  相似文献   

5.
We describe the use of a tri(ethylene glycol)-terminated alkyltrichlorosilane to create a very thin, protein-resistant "self-assembled monolayer" coating on the inner surface of a fused-silica capillary. The same compound has been demonstrated previously on flat silica substrates to resist adsorption of many proteins. As a covalently bound capillary coating, it displays good resistance to the adsorption of cationic proteins, providing clean separations of a mixture of lysozyme, cytochrome c, ribonuclease A, and myoglobin for more than 200 consecutive runs. Electroosmotic flow (EOF) was measured as a function of pH; the coated capillary retains significant cathodal EOF, with roughly 50% of the EOF of an uncoated capillary at neutral pH, making this coating promising for applications requiring some EOF. The EOF was reasonably stable, with a 2.9% relative standard deviation during a 24 h period consisting of 72 consecutive separations of cationic proteins. Efficiencies for cationic protein separations were moderate, in the range of 190,000-290,000 theoretical plates per meter. The coating procedure was simple, requiring only a standard cleaning procedure followed by a rinse with the silane reagent at room temperature. No buffer additives are required to maintain the stability of the coating, making it flexible for a range of applications, potentially including capillary electrophoresis-mass spectrometry (CE-MS).  相似文献   

6.
Wei W  Ju H 《Electrophoresis》2005,26(3):586-592
A zwitterionic surfactant, dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium (C12H25N+(CH3)2CH2CHOHCH2SO3-), named dodecyl sulfobetaine (DSB), was used as a novel modifier to coat dynamically capillary walls for capillary electrophoresis separation of basic proteins. The DSB coating suppressed the electroosmotic flow (EOF) in the pH range of 3-12. At high DSB concentration, the EOF was suppressed by more than 8.8 times. The DSB coating also prevented successfully the adsorption of cationic proteins on the capillary wall. Anions, such as Cl-, Br-, I-, SO4(2-), CO3(2-), and ClO4-, could be used as running buffer modifiers to adjust the EOF for better separation of analytes. Using this dynamically coated capillary, a mixture of eight inorganic anions achieved complete separation within 4.2 min with the efficiencies from 24,000 to 1,310,000 plates/m. In the presence of ClO4- as EOF adjustor, the separation of a mixture containing four basic proteins (lysozyme, cytochrome c, alpha-chymotrypsinogen A, and myoglobin) yielded efficiencies of 204,000-896,000 plates/m and recoveries of 88%-98%. Migration time reproducibility of these proteins was less than 0.5% relative standard deviation (RSD) from run to run and less than 3.1% RSD from day to day, showing promising application of this novel modifier in protein separation.  相似文献   

7.
The potential of capillaries noncovalently coated with a bilayer of oppositely charged polymers for the analysis of peptides by CE-MS was investigated. Bilayer coatings were produced by subsequently rinsing fused-silica capillaries with a solution of Polybrene (PB) and poly(vinyl sulfonate) (PVS). The PB-PVS coating showed to be fully compatible with MS detection causing no ionization suppression or background signals. The bilayer coating provided a considerable EOF at low pH, thereby facilitating the fast separation of peptides using a BGE of formic acid (pH 2.5). Under optimized CE-MS conditions, for enkephalin peptides high separation efficiencies were obtained with plate numbers in the range of 300,000-500,000. It is demonstrated that both the cancellation of the hydrodynamic capillary flow induced by the nebulizer gas and a sufficiently high-data acquisition rate are crucial for achieving these efficiencies. The overall performance of the CE-MS system using PB-PVS-coated capillaries was evaluated by the analysis of a tryptic digest of cytochrome c. The system provided an efficient separation of the peptide mixture, which could be effectively monitored by MS/MS detection allowing identification of at least 13 peptides within a time interval of 1.5 min. In addition, the PB-PVS coating proved to be very consistent yielding stable CE-MS patterns with highly favorable migration time reproducibilities (RSDs < 1% over a 3-day period).  相似文献   

8.
A surfactant/polymer wall coating consisting of the doubly chained cationic surfactant dimethyldioctadecylammonium bromide (DODAB) and polyoxyethylene (POE) 40 stearate is investigated. The coating is formed by simply rinsing a capillary with a solution containing DODAB and POE 40 stearate. The resultant coating is semi-permanent--demonstrating stable electroosmotic flow (EOF) even after a 60 min high pressure rinse with buffer. The EOF (-0.45+/-(0.23) x 10(-4) cm(2) V(-1) s(-1) at pH 7.4) is suppressed by more than a factor of ten compared to that observed for DODAB alone. Model protein mixtures were separated over a pH range of 3-10 with efficiencies of up to greater than 1 million plates/m for the basic proteins cytochrome c, lysozyme, ribonuclease A and alpha-lactalbumin, and the acidic proteins insulin chain A, trypsin inhibitor, and alpha-chymotrypsinogen A. Migration time reproducibility was 0.5-4.0% from run to run and 0.6-4.3% from day to day. Protein recoveries with this coating ranged from 84% to 97%.  相似文献   

9.
The use of the electrospray ionization (ESI) method for interfacing capillary electrophoresis with mass spectrometry (CE-MS) is particularly well suited for the analysis of large molecules due to the multiple charging phenomenon. While ionization efficiency is very high, the available ion current is dispersed over more peaks so that the maximum peak intensity obtainable declines significantly for large molecules. Sensitivity with ESI can be improved by operation at very low flow-rates, an ideal situation for CE-MS. These and other considerations related to sensitivity are illustrated using ESI-MS measurements for cytochrome c.  相似文献   

10.
A simple and economical CE method has been developed for the analysis of four model basic proteins by employing N‐methyl‐2‐pyrrolidonium methyl sulfonate ionic liquid (IL) as the dynamic coating material based on the interaction of both between electrostatic attraction and hydrogen bond, and between the organic cations of IL and the inner surface of bare fused‐silica capillary. The N‐methyl‐2‐pyrrolidonium‐based IL modified capillary not only generated a stable suppressed electroosmotic flow, but also effectively eliminated the wall adsorption of proteins. Several important parameters such as the IL concentration, pH values, and concentrations of the background electrolyte were optimized to improve the separation of basic proteins. Consequently, under the optimum separation conditions, a satisfied separation of basic proteins including lysozyme, cytochrome c, ribonuclease A, and α‐chymotrypsinogen A with theoretical plates ranging from 2.09 × 105 to 4.48 × 105 plates/m had been accomplished within 15 min. The proposed method first illustrated the effect of hydrogen bond between coating material and inner capillary surface on the coating, which should be a new strategy to design and select more effective coating materials to form more stable coatings in CE.  相似文献   

11.
1,2-Dioleyl-3-trymethylammoniumpropane (DOTAP) lipid vesicles were employed as coating precursors to obtain a semipermanent cationic lipid bilayer in silica capillary. The coating procedure was relatively fast and simple. Reliable results for the separation of four basic proteins (alpha-chymotrypsinogen A, ribonuclease A, cytochrome C, lysozyme) were obtained by using an acetate buffer under acidic conditions. The RSDs of the migration times were not higher than 0.5% run-to-run and about 1% day-to-day (3 days), while the RSDs of the peak areas were within 7% day-to-day (3 days). The day-to-day RSD of the EOF mobility of about 1%, confirmed that the DOTAP coating was stable for the separation of basic proteins, under acidic buffers. In addition to basic proteins the DOTAP coating was found suitable under acidic conditions for the repeatable separation of neutral steroids. The potential of DOTAP as a carrier in background electrolyte solution was studied.  相似文献   

12.
In aqueous capillary electrophoresis, the electroosmotic flow can be strongly suppressed by coating the inner surface of the capillary. In the present work hydrophilic coating of 4% polyvinyl alcohol (PVA) has been used for the analysis of basic proteins. The coating is simple and easy to obtain. The separation of ribonuclease and α-chymotrypsin has been uniquely done with other three basic proteins (lysozyme, cytochrome-c and trypsin) using a buffer 11.60 mM sodium acetate and 18.40 mM acetic acid at pH 4.5 in addition to positive power supply of 20 kV at 25°C. Detection was performed using UV detector at 230 nm. The proposed PVA coated capillary provides reproducible separation of five basic proteins within 10 min with RSD values for mobility bellow 1.4% (n = 6) for all the five basic proteins. The stability of coated capillary has been checked up to 40 runs. The viscosity measurement for 4% PVA have been studied and scanning electron microscope (SEM) images obtained to make it compatible with future micro-chip applications.  相似文献   

13.
We present the polymer poly-N-hydroxyethylacrylamide (PHEA) (polyDuramide) as a novel, hydrophilic, adsorbed capillary coating for electrophoretic protein analysis. Preparation of the PHEA coating requires a simple and fast (30 min) protocol that can be easily automated in capillary electrophoresis instruments. Over the pH range of 3-8.4, the PHEA coating is shown to reduce electroosmotic flow (EOF) by about 2 orders of magnitude compared to the bare silica capillary. In a systematic comparative study, the adsorbed PHEA coating exhibited minimal interactions with both acidic and basic proteins, providing efficient protein separations with excellent reproducibility on par with a covalent polyacrylamide coating. Hydrophobic interactions between proteins and a relatively hydrophobic poly-N,N-dimethylacrylamide (PDMA) adsorbed coating, on the other hand, adversely affected separation reproducibility and efficiency. Under both acidic and basic buffer conditions, the adsorbed PHEA coating produced an EOF suppression performance comparable to that of covalent polyacrylamide coating and superior to that of adsorbed PDMA coating. The protein separation performance in PHEA-coated capillaries was retained for 275 consecutive protein separation runs at pH 8.4, and for more than 800 runs at pH 4.4. The unique and novel combination of hydrophilicity and adsorptive coating ability of PHEA makes it a suitable wall coating for automated microscale analysis of proteins by capillary array systems.  相似文献   

14.
Wu X  Wei W  Su Q  Xu L  Chen G 《Electrophoresis》2008,29(11):2356-2362
1-Butyl-3-methylimidazolium tetrafluoroborate ionic liquids (1B-3MI-TFB ILs) were employed as a coating material and BGE in CE for simultaneous separation of basic and acidic proteins such as lysozyme, cytochrome C, ribonuclease A, albumin, and alpha-lactalbumin. 1B-3MI-TFB ILs effectively reversed the surface charges on the capillary inner surface, preventing the adsorption of positively charged proteins onto the silica surface, as well as associated with proteins, thus benefiting the separation efficiencies and reproducibility. Consequently, simultaneous baseline separation of five proteins was achieved within 14 min by using 10 mM of 1B-3MI-TFB ILs as dynamic coating and the only running electrolyte at the voltage of +20 kV. The proposed coating technique is simple, less time-consuming, reproducible, and also stable enough for proteins separation without the need of additives. Symmetrical peaks with efficiencies up to 670,000 plates/m were obtained. Recoveries of proteins with RSD (for migration times) of 0.23-0.42% (run-to-run) and 2.5-3.8% (day-to-day) were achieved, respectively. The applicability of the proposed method in proteins separation was evaluated by the separation of egg white samples.  相似文献   

15.
The usefulness of a noncovalent, positively charged capillary coating for the efficient analysis of intact basic proteins with CE was studied. Capillaries were coated by subsequent flushing with solutions of 10% w/v Polybrene (PB), 3% w/v dextran sulfate (DS), and again 10% w/v PB. Coating characterization studies showed that stable coatings could be produced which exhibited a pH‐independent and highly reproducible EOF. The PB–DS–PB coating was evaluated with Tris phosphate BGEs of various pH using the four basic model proteins: α‐chymotrypsinogen A, ribonuclease A, cytochrome c, and lysozyme. Typical migration time RSDs for the proteins were less than 0.85%, and apparent plate numbers were above 125 000 using a capillary length of 40 cm. The high separation efficiency allowed detection of several minor impurities in the model proteins. Using a BGE of medium pH, the CE system with triple‐layer coating appeared to be useful for the repeatable profiling of recombinant humanized mouse monoclonal immunoglobulin G1 showing a characteristic pattern of glycoforms. The CE system was also applied to the characterization of two llama antibodies, which were produced in Saccharomyces cerevisiae, revealing the presence of a side product in one of the antibodies. The high migration time stability allowed the reliable determination of antibody–antigen binding by monitoring migration time shifts. Finally, the feasibility of using the PB–DS–PB coated capillaries for CE with mass spectrometric detection was shown by the characterization of the impure llama antibody sample.  相似文献   

16.
A new methodology is proposed to automate the monitoring of sulfonamide residues in milk samples. It combines a screening unit for the total amount of sulfonamide with capillary electrophoresis-mass spectrometry (CE-MS) equipment for processing the samples containing a detectable level of sulfonamide. The screening unit consists of continuous-flow system (CFS) to precipitate the proteins connected on-line to the CE-MS equipment, in which a common characteristic ion of all sulfonamides was monitored with the MS detector by flushing the sample through the capillary. The confirmatory method is based on the purification and preconcentration of sulfonamides in a CFS unit and posterior analysis by CE-MS. The sample treatment unit was also on-line connected to the CE-MS equipment. In order to increase sensitivity, the flow rate of the sheath liquid was diminished from 0.5 to 0.2 microL.min(-1) by increasing the content in water from 0 to 50% and the formic acid from 0.5 to 1.5% in this liquid and by applying an overimposed pressure of 5 mbar during the electrophoretic separation. The method allowed the analysis of 30 samples per hour.  相似文献   

17.
Fu X  Huang L  Gao F  Li W  Pang N  Zhai M  Liu H  Wu M 《Electrophoresis》2007,28(12):1958-1963
A hydrophilic basic polysaccharide, carboxymethyl chitosan (CMC) as a capillary coating is presented with a simple preparation procedure. The CMC-coated capillary showed a long lifetime of more than 100 runs, and had good tolerance to some organic solvents, 0.1 M HCl, 0.1 M NaOH, and 5 M urea. The run-to-run, day-to-day, and capillary-to-capillary RSDs for the CMC-coated capillary were all below 2.0% for the determination of EOF. Moreover, the coatings with different concentrations and molecular weights of CMC were also investigated. The CMC-coated capillary was successfully applied to separate basic proteins and recombinant human erythropoietin (rhEPO). Furthermore, several experimental parameters, such as the concentration and pH of the running buffer, temperature, and applied voltage, were optimized for the separation of rhEPO glycoforms. Comparison of an uncoated capillary with chitosan- and CMC-coated capillaries for the separation of rhEPO glycoforms was also discussed. The results demonstrated that rhEPO glycoforms can be well separated by a CMC-coated capillary within 8 min with good reproducibility and resolution. Finally, the volatile BGE HAc-NH4Ac was utilized to separate rhEPO for its further application with CE-MS, achieving a satisfactory result.  相似文献   

18.
Tang FP  Leung GN  Wan TS 《Electrophoresis》2001,22(11):2201-2209
A capillary electrophoresis-mass spectrometry (CE-MS) method for the analysis of quaternary ammonium drugs in equine urine was developed. Quaternary ammonium drugs were first extracted from equine urine by ion-pair extraction and then analysed by CE-MS in the positive electrospray ionization (ESI) mode. Within 12 min, eight quaternary ammonium drugs, each at 1 ng/mL in horse urine, could be detected. The confirmation of these drugs in urine samples was achieved by capillary electrophoresis tandem mass spectrometry (CE-MS/MS). A direct comparison of this method was made with existing liquid chromatography/mass spectrometry (LC-MS) methods in the detection and confirmation of glycopyrrolate and ipratropium bromide in horse urine. While the two drugs could be detected within the same CE-MS run at 1 ng/mL in urine, they could only be detected in separate LC-MS runs at 5 ng/mL in urine. In addition, CE-MS consumed a much smaller volume of extract; the analyte peak widths, in some cases, were much narrower; and as the quaternary ammonium ions were well separated electrophoretically from the mainly neutral urine matrix, a much cleaner background in the CE-MS total ion trace was observed.  相似文献   

19.
Zhou S  Tan J  Chen Q  Lin X  Lü H  Xie Z 《Journal of chromatography. A》2010,1217(52):8346-8351
A novel open tubular (OT) column covalently modified with hydrophilic polysaccharide, carboxymethylchitosan (CMC) as stationary phase has been developed, and employed for the separations of basic proteins and opium alkaloids by capillary electrochromatography (CEC). With the procedures including the silanization of 3-aminopropyltrimethoxysilane (APTS) and the combination of glutaraldehyde with amino-silylated silica surface and CMC, CMC was covalently bonded on the capillary inner wall and exhibited a remarkable tolerance and chemical stability against 0.1 mol/L HCl, 0.1 mol/L NaOH or some organic solvents. By varying the pH values of running buffer, a cathodic or anodic EOF could be gained in CMC modified column. With anodic EOF mode (pH<4.3), favorable separations of basic proteins (trypsin, ribonuclease A, lysozyme and cytochrome C) were successfully achieved with high column efficiencies ranging from 97,000 to 182,000 plates/m, and the undesired adsorptions of basic proteins on the inter-wall of capillary could be avoided. Good repeatability was gained with RSD of the migration time less than 1.3% for run-to-run (n=5) and less than 3.2% for day-to-day (n=3), RSD of peak area was less than 5.6% for run-to-run (n=5) and less than 8.8% for day-to-day (n=3). With cathodic EOF mode (pH>4.3), four opium alkaloids were also baseline separated in phosphate buffer (50 mmol/L, pH 6.0) with column efficiencies ranging from 92,000 to 132,000 plates/m. CMC-bonded OT capillary column might be used as an alternative medium for the further analysis of basic proteins and alkaline analytes.  相似文献   

20.
The properties and behavior of polyethyleneimine (PEI) covalently coated capillaries with respect to different background electrolytes used in capillary zone electrophoresis (CZE) are described. The coating stability and changes of inner surface charge in the capillary were followed by measurement of electroosmotic flow (EOF). Interest was focused mainly on conjugate bases of carboxylic acids as anionic background electrolyte components (acetate, citrate, malate, malonate, tartrate, and succinate). An interesting phenomenon was observed in PEI-coated capillaries: The direction (and the magnitude) of EOF depends on the composition of the background electrolyte and at a certain pH it can undergo reversible change. Ionic complex formation was suggested as a hypothesis to explain this behavior. With this knowledge, the PEI-coated capillary was used for the separation of basic proteins in the above-mentioned background electrolytes. A standard protein mixture of cytochrome c, ribonuclease A, and lysozyme at a concentration of 0.25 mg/mL each was chosen as model sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号