首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and reliable precolumn derivatization liquid chromatography method with ultraviolet detection has been developed and validated for the analysis of glucosamine (GS) in various dietary supplement formulations and raw materials. Additionally, the proposed method was used for analysis of carisoprodol (CR) found in ternary mixture with paracetamol (PR) and caffeine (CF). The linearity ranges were 1-100 μg/mL for GS, 1-150 μg/mL for CR, PR and CF. Derivatization was used with 1,2-naphthoquinone-4-sulphonic acid sodium salt in the presence of borate buffer. Chromatographic separation of GS-naphthoquinone derivative was achieved by using a mixture of acetonitrile and water (pH 7.3 adjusted with 0.1 M NaOH) in the ratio 10:90, v/v and flow-rate of 1.0 mL/min. UV detection was carried out at 280 nm. For PR, CF, and CR-naphthoquinone derivative, the chromatographic separation was achieved by using mixture of acetonitrile and 20 mM KH(2)PO(4) (pH 3.0 adjusted with phosphoric acid) in the ratio 20:80, v/v and flow-rate of 1.0 mL/min. UV detection was carried out at 275 nm. The limits of detection were 37.2, 35.9, 30.4 and 40.0 ng/mL for GS, CR, PR and CF, respectively.  相似文献   

2.
In the present study, a simple and rapid reversed-phase HPLC method for the determination of astaxanthin in shrimp waste hydrolysate has been developed and validated. The analytical procedure involves the direct extraction of astaxanthin from the lipid fraction with methanol. The analytical column, SS Exil ODS, was operated at 25C. The mobile phase consisted of a mixture of water:methanol:dichloromethane:acetonitrile (4.5:28:22:45.5 v/v/v/v) at a flow rate of 1.0 mL/min. Detection and identification were performed using a photodiode array detector (lambda(detection) = 476 nm). The proposed HPLC method showed adequate linearity, repeatability and accuracy.  相似文献   

3.
A new, simple, precise and rapid high performance liquid chromatographic method was developed for the determination of meropenem in human serum, urine and pharmaceutical dosage forms. Chromatography was carried out on an LC(18) column using a mixture of 15 mM KH(2)PO(4):acetonitrile:methanol (84:12:4; v/v/v), adjusted to pH 2.8 with H(3)PO(4). The proposed method was conducted using a reversed-phase technique, UV monitoring at 307.6 nm and cefepime as an internal standard. The retention times were 5.98 and 7.47 min for cefepime and meropenem, respectively. The detector response was linear over the concentration range of 50-10,000 ng/mL. The detection limit of the procedure was found to be 22 ng/mL. The detection limit for meropenem in human plasma was 108.4 ng/mL and the corresponding value in human urine was 179.3 ng/mL. No interference from endogenous substances in human serum, urine and pharmaceutical preparation was observed. The proposed method is sufficiently sensitive for determination of the concentrations of meropenem and may have clinical application for its monitoring in patients receiving the drug.  相似文献   

4.
A simple and sensitive high-performance liquid chromatographic method for the determination of Therminol 66 thermal heating fluid in glycerin and fatty acids is developed. Sample solutions dissolved in methanol-tetrahydrofuran (50:50, v/v) are injected directly into a reversed-phase C18 column and eluted with a methanol and water mixture (88:12, v/v). The concentration of the thermal heating fluid is monitored by fluorescence detection at 257 nm (excitation) and 320 nm (emission). The calibration graph obtained from various concentrations of the thermal heating fluid in the methanol and tetrahydrofuran mixture is linear (correlation coefficient = 0.999), and the limit of detection is 0.01 microg/mL. Spiked glycerin containing 0.1 to 1.0 microg/g of the thermal heating fluid also gives good linearity with a mean recovery of 95.3%. The mean intra- and interassay precision are 1.80-6.51% and 5.71-9.03%, respectively, at the 0.1-microg/g level. The method is simple and does not require any pretreatment step, thus it is ideal for quality assurance purposes.  相似文献   

5.
A single line flow injection analysis (FIA) method that incorporated a preconcentrator column packed with C(18) particles and capacitively coupled contactless conductivity detector (C(4)D) was developed for the determination of free fatty acid (FFA) in vegetable oils. The carrier stream was methanol/1.5 mM sodium acetate (pH 8) 80:20 (v/v) at a flow rate of 1.0 mL min(-1). Calibration curve was well correlated (r(2)=0.9995) within the range of 1-200 mg L(-1) FFA (expressed as palmitic acid). Sampling rate of 40-60 h(-1) was achieved. Good agreement was found between the standard non-aqueous titrimetry method and the proposed method when applied to the determination of FFA in palm (crude, olein, and refined, bleached and deodorised) and other vegetable (soybean, rice bran, walnut, corn and olive) oils. The proposed method offers distinct advantages over the official method, especially in terms of simplicity, high sampling rate, economy of solvents and sample, offering considerable promise as a low cost automated system that needs minimum human intervention over long periods of time.  相似文献   

6.
The separation and determination of tocopherols (Ts) in vegetable oils by CEC using methacrylate ester-based monolithic columns has been developed. The effects of pore size of the monolithic columns were studied, and the composition of mobile phase was optimized. The optimal pore size of the monolith was obtained with 12 wt% 1,4-butanediol in the polymerization mixture. Excellent resolution between tocopherols was achieved within 10 min analysis time with a 99:1 v/v MeOH-aqueous buffer containing 5 mM tris(hydroxymethyl)aminomethane at pH 8.0. The LODs were lower than 2.3 microg/mL, and interday and column-to-column reproducibilities at 25 microg/mL were better than 5.6%. Using a 93:7 v/v MeOH-aqueous buffer, both tocopherols and tocotrienols (T(3)s) of grapeseed and palm oils were resolved. Application to the detection of olive oil adulteration with low-cost edible oils was demonstrated.  相似文献   

7.
This work presents a high-performance liquid chromatography (HPLC) method for the quantitation of glucosamine in chitin. The method includes an acid hydrolysis of chitin. The chromatographic separation is achieved using a Hypersil ODS 5-microm column (250 x 4.6 mm) at 38 degrees C, with precolumn derivatization with 9-fluorenylmethyl-chloroformate and UV detection (lambda = 264 nm). The mobile phase is a mixture of mobile phase A [30 mM ammonium phosphate (pH 6.5) in 15:85 methanol-water (v/v)], mobile phase B [15:85 methanol-water (v/v)], and mobile phase C [90:10 acetonitrile-water (v/v)], with a flow rate of 1.2 mL/min. The HPLC method proposed showed adequate repeatability (relative standard deviation, 5.8%), accuracy (92.7% recovery), and sensitivity, with a detection limit of 2 microg/mL. The method is successfully applied to the quantitation of glucosamine for the determination of the purity of chitin from shrimp waste.  相似文献   

8.
A new liquid chromatography-mass spectrometry (LC-MS) method is developed and validated for the identification and determination of novel 4,5-diazafluoren-9-one compound. The method employs a Waters XTerra RP-18 column (150 mmx4.6 mm, i.d. 5 microm) with a mobile phase comprised of a (50:50, v/v) mixture of deionized water containing 0.2% acetic acid (solvent A) and methanol (solvent B) at a flow rate of 1 mL/min, at 35 degrees C. The detection is performed with photodiode-array (PDA) set at 210-400 nm and single quadropole mass spectrometer with electrospray ionization (ESI) positive ion mode. The chromatographic separation is achieved in less than 3 min. The linearity is established over the concentration range of 0.1-0.5 mg/mL (r2=1.000). The mean RSD values for intra- and inter-day precision studies are <2%. The recovery of 4,5-diazafluoren-9-one ranged between 99.84 and 99.97%. The limits of detection and quantitation are determined to be 0.58 and 0.1 mg/mL, respectively.  相似文献   

9.
李善茂  李伟  岳丽君  左伯莉 《色谱》2005,23(5):545-547
二苯氯胂和二苯氰胂是刺激性毒剂,在环境中易于降解,其产物苯胂酸、苯胂氧、二苯胂酸、氧联双二苯胂和三苯胂比较稳定,对环境危害大。建立了同时测定这5种含胂产物的反相高效液相色谱方法,选择了最佳色谱条件,提供了各组分的紫外光谱图。5种化合物的线性范围分别为8~30,5~40,20~4000,120~8000,1~60 mg/L,检测限分别为0.1,0.1,0.2,10,0.1 mg/L。对实际环境样品进行了分析,结果较好。  相似文献   

10.
Liu M  Zhang S  Yang C  Xia Y  Liu J  Liang J 《色谱》2011,29(5):430-434
应用高速逆流色谱法分离制备了生附子中的3个C19型二萜生物碱类化合物。以正己烷-乙酸乙酯-甲醇-水(3:5:4:5, v/v/v/v)为两相溶剂系统,上相为固定相,下相为流动相,在主机转速850 r/min、流动相流速2.0 mL/min、检测波长235 nm条件下进行分离制备;一次性从90 mg附子总碱粗提物中分离制备得到15.3 mg北草乌碱,35.1 mg中乌头碱和22.7 mg次乌头碱,经高效液相色谱分析,测得它们的纯度分别为97.9%、96.2%和99.2%。并应用波谱(电喷雾离子质谱、核磁共振氢谱和核磁共振13C谱)解析法确定了它们的结构。利用该方法可以对生附子中的二萜类生物碱成分进行快速的分离和纯化  相似文献   

11.
皮立  胡凤祖  师治贤 《色谱》2005,23(6):639-641
用所建立的高效液相色谱-荧光检测法测定了罂粟籽和火锅汤料中的罂粟碱。采用的色谱柱为RP-C18柱(250 mm×4.6 mm i.d.,5 μm);检测激发波长为285 nm,发射波长为355 nm;流动相为甲醇-0.02 mol/L乙酸铵(体积比为70∶30),流速0.8 mL/min。实验结果表明,罂粟碱的进样量为1×10-4~0.1 μg时其质量浓度与相应峰面积有良好的线性关系,最低检测限(以信噪比大于3计)达到0.02 ng。罂粟籽中罂粟碱的回收率为99.0%~100.8%。方法快速准确,简便灵敏,分离度高,能够满足有关食品中罂粟碱的检测要求。  相似文献   

12.
反相高效液相色谱法测定生物转化体系中的甘草酸   总被引:6,自引:0,他引:6  
李晖  卢定强  刘伟民 《色谱》2004,22(3):258-259
采用高效液相色谱法在Hypersil C18色谱柱(4.6 mm i.d.×250 mm,5 μm)上以甲醇-水-冰醋酸(70∶30∶1, 体积比)为流动相分离测定了甘草酸单铵盐生物(酶)转化体系中的甘草酸,流动相流速为1.0 mL/min,紫外检测波长254 nm。实验结果表明,该方法在进样量为0.2~20 μg时具有良好的线性;样品的加标回收率为98%~103%,相应的相对标准偏差为0.16%~1.58%。方法简便、快速、可靠。  相似文献   

13.
A mixture of saponin compounds (saikosaponin c, a, and d) in the 70% ethanol extract of a powdered sample of Bupleuri radix are analyzed by an Inertsil ODS-3 C(18) column at a flow rate of 1.0 mL/min and detection wavelength of 203 nm. Well resolved chromatograms of saikosaponin c, a, and d are obtained with a gradient elution of acetonitrile-water from 40:60 (v/v) to 50:50 (v/v). The total time required for a single analysis is approximately 20 min. Calibration curves for saikosaponin c, a, and d are linear up to 2.5 mg/mL. The coefficient of variability values for saikosaponins in the extract are below 4%, and the recoveries for saikosaponin c, a, and d are 95.2 +/- 1.1, 96.5 +/- 0.9, and 96.2 +/- 1.0%, respectively. The changes in saikosaponin contents for a two-year growth of Bupleurum falcatum are measured by the established high-performance liquid chromatography method.  相似文献   

14.
A new, simple, and reproducible method for determination of carboxylic acid metabolite of clopidogrel in human plasma has been developed. After liquid-liquid extraction in acidic medium with chloroform, samples were quantified on a Nova-pak C(8), 5 microm column using a mixture of 30 mM K(2)HPO(4)-THF-acetonitrile (pH = 3, 79:2:19, v/v/v) as mobile phase with UV detection at 220 nm. The flow rate was set at 0.9 mL/min. Ticlopidine was used as internal standard and the total run time of analysis was about 12 min. The method was linear over the range of 0.2-10 microg/mL of clopidogrel metabolite in plasma (r(2) > 0.999). The within-day and between-day precision values were in the range 1.0-4.8%. The limit of quantification of the method was 0.2 microg/mL. The method was successfully used to study the pharmacokinetics of clopidogrel in healthy volunteers.  相似文献   

15.
The initial decrease of solvated electrons in tetrahydrofuran (THF) upon addition of biphenyl was investigated by picosecond pulse radiolysis. Transient absorption spectra derived from the biphenyl radical anion (centered at 408 and 655 nm) and solvated electrons of THF (infrared) were successfully measured in the wavelength region from 400 to 900 nm by the extension of a femtosecond continuum probe light to near-ultraviolet using a second harmonic generation of Ti:sapphire laser and a CaF2 plate. From the analysis of kinetic traces at 1300 nm considering the overlap of primary solvated electrons and partial biphenyl radical anion, C37, which is defined by the solute concentration to reduce the initial yield of solvated electrons to 1/e, was found to be 87 +/- 3 mM. The rate constant of solvated electrons with biphenyl was determined as 5.8 +/- 0.3 x 10(10) M(-1) s(-1). We demonstrate that the kinetic traces at both 408 nm mainly due to biphenyl radical anion and 1300 nm mainly due to solvated electrons are reproduced with high accuracy and consistency by a simple kinetic analysis. Much higher concentrations of biphenyl (up to 2 M) were examined, showing further increase of the initial yield of biphenyl radical anion accompanying a fast decay component. This observation is discussed in terms of geminate ion recombination, scavenging, delayed geminate ion recombination, and direct ionization of biphenyl at high concentration.  相似文献   

16.
Perfluorinated surfactants of heptafluorobutylate and pentadecafluorooctanoate ions were adsorbed on an activated charcoal cartridge and decomposed with sodium biphenyl (SBP) reagent to form inorganic fluoride ion. The fluoride ion thus formed was determined by flow injection analysis (FIA) using quercetin-Zr complex as a fluorimetric reagent, where λex and λem were 422 and 491 nm, respectively. The limit of detection for fluoride ion by the FIA system was developed to 1.1 × 10−6 M (signal to noise ratio of three), when 50% (v/v) tetrahydrofuran (THF) was used as a dissolving solvent for quercetin. The perfluorinated surfactants in the sample solution were quantitatively adsorbed on the cartridge containing 100 mg of activated charcoal and were decomposed with 0.5 mL of sodium biphenyl reagent after drying thoroughly by flowing through dry nitrogen gas. The fluoride ion formed was recovered with 3 mL of purified water as an eluent, and it was determined by the fluorimetric flow injection system. The blank fluorescence signal accompanied during the adsorption/decomposition on the cartridge was reduced by washing the activated charcoal with acetone. The blank signal was also observed from dimethoxyethane, which was used in sodium biphenyl reagent. When 600 mL sample solution was used and 200 times enrichment was applied, the heptafluorobutylate and pentadecafluorooctanoate ions at the concentrations of 2.1 μg L−1 were quantitatively recovered as fluoride ion, and the limit of detections for the perfluorinated surfactants were 0.3 and 0.3 μg L−1 for the two perfluorinated surfactants, respectively (3 sigma of the blank signal).  相似文献   

17.
A simple high-performance liquid chromatographic method with ultraviolet detection is proposed for the estimation of diclofenac potassium and drotaverine hydrochloride in human plasma. Liquid-liquid extraction was carried out with a mixture of dichloromethane-isopropyl alcohol (80:20, v/v). Chromatographic separation of the analytes and internal standard was achieved on an analytical 250 × 4.6 mm i.d. reversed-phase Thermo BDS Hypersil C8 (5 μm particle size) column using a mobile phase of acetonitrile-0.02M ammonium acetate buffer (53:47, v/v) at pH 3.5. The run time was less than 15 min. Column eluate was monitored at 230 nm. The linearity over the concentration ranges of 25-1500 ng/mL and 32-960 ng/mL was obtained for diclofenac potassium and drotaverine hydrochloride, respectively. The limit of quantification was 25 and 32 ng/mL for diclofenac potassium and drotaverine hydrochloride, respectively. Recoveries of diclofenac potassium and drotaverine hydrochloride from plasma were 97.45% and 98.27%, respectively.  相似文献   

18.
A simple, fast, and sensitive HPLC method was developed and validated for the evaluation of pregabalin in a pharmaceutical dosage form using fluorescamine as a derivatization agent for the first time. After a precolumn derivatization (5 min, room temperature), the reaction mixture was chromatographed on a C18 column with isocratic elution using 0.2% of triethylamine in a mixture of methanol and water (10 + 90, v/v). 3-Aminopentanoic acid was used as the internal standard. Using fluorescent detection (lamdaex 395 nm, lamdaem 476 nm), a low detection limit of 0.02 microg/mL was reached. The method was linear (r > 0.999) over the lower (0.125-25 microg/mL) and higher (1.25-250 microg/mL) concentration range. The intraday and interday precision of the QC samples was < 4.3%, and the accuracy was 94.2-102.5%. The samples were stable for 24 h at 4 degrees C. The robustness study showed that the derivatization is more robust than the chromatography method. The method was applied for the analysis of pregabalin content in 25, 75, and 300 mg capsules, and a good agreement was found with the declared amount of pregabalin (the relative error did not exceed 3.2%). Finally, the method was successfully used for dissolution studies of pregabalin capsules.  相似文献   

19.
The development of a two phase hollow fiber liquid-phase microextraction technique, followed by gas-chromatography-flame ionization detection (GC-FID) for the profiling of the fatty acids (FAs) (lauric, myristic, palmitic, stearic, palmitoleic, oleic, linoleic, linolenic and arachidic) in vegetable oils is described. Heptadecanoic acid methyl ester was used as the internal standard. The FAs were transesterified to their corresponding methyl esters prior to the extraction. Extraction parameters such as type of extracting solvent, temperature, extraction time, stirring speed and salt addition were studied and optimized. Recommended conditions were extraction solvent, n-tridecane; extraction time, 35 min; extraction temperature, ambient; without addition of salt. Enrichment factors varying from 37 to 115 were achieved. Calibration curves for the nine FAs were well correlated (r(2)>0.994) within the range of 10-5000 μg L(-1). The limit of detection (signal:noise, 3) was 4.73-13.21 ng L(-1). The method was successfully applied to the profiling of the FAs in palm oils (crude, olein, kernel, and carotino cooking oil) and other vegetable oils (soybean, olive, coconut, rice bran and pumpkin). The encouraging enrichments achieved offer an interesting option for the profiling of the minor and major FAs in palm and other vegetable oils.  相似文献   

20.
A selective and sensitive coupled-column high-performance liquid chromatographic method is developed for the simultaneous determination of 5 phenylurea herbicides (monuron, linuron, isoproturon, monolinuron, and diuron) in environmental and drinking water samples. Sample clean-up is performed automatically by means of a column switching technique. Using 2 octadecyl silica columns connected via two programmable 6-port valves and ultraviolet detection at 244 nm, the aforementioned compounds can be determined at the low concentration levels required for pesticide residue analysis in water samples. A mobile phase consisting of a mixture of methanol-water (55:45, v/v) is pumped at 1 mL/min. For the 5 phenylureas, high recoveries ranging from 94.9 to 101.6%, good reproducibility with relative standard deviations lower than 5%, and wide linear ranges up to 20 micrograms/L are observed with determination limits of 0.05 microgram/L. The method is successfully applied to the screening of different environmental water samples such as surface, ground, rain, and drinking water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号