首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 781 毫秒
1.
郭斌  赵建福  李凯  胡文瑞 《力学学报》2021,53(4):1170-1182
液氢是一种常用的沸点低、易蒸发的空间低温推进剂.空间微重力环境中浮力对流被极大减弱,当推进剂储罐壁面存在局部漏热时,储罐内部气液两相流体系会出现环绕漏热源的热分层现象,引起局部过热沸腾,导致储罐内部压力急剧增大,危害系统结构安全.利用低温射流抑制储罐热分层现象是一种有效手段.低温流体通过设置在储罐内部的射流喷嘴与储罐内...  相似文献   

2.
3.
In this study, forced convection heat transfer characteristics of nanofluids are investigated by numerical analysis of incompressible transient laminar flow in a circular duct under step change in wall temperature and wall heat flux. The thermal responses of the system are obtained by solving energy equation under both transient and steady-state conditions for hydro-dynamically fully-developed flow. In the analyses, temperature dependent thermo-physical properties are also considered. In the numerical analysis, Al2O3/water nanofluid is assumed as a homogenous single-phase fluid. For the effective thermal conductivity of nanofluids, Hamilton–Crosser model is used together with a model for Brownian motion in the analysis which takes the effects of temperature and the particle diameter into account. Temperature distributions across the tube for a step jump of wall temperature and also wall heat flux are obtained for various times during the transient calculations at a given location for a constant value of Peclet number and a particle diameter. Variations of thermal conductivity in turn, heat transfer enhancement is obtained at various times as a function of nanoparticle volume fractions, at a given nanoparticle diameter and Peclet number. The results are given under transient and steady-state conditions; steady-state conditions are obtained at larger times and enhancements are found by comparison to the base fluid heat transfer coefficient under the same conditions.  相似文献   

4.
The present experimental investigation is concerned with the transient flow response in a reservoir model to periodic heating and cooling at the water surface. The experiment reveals a stable stratification of the water body during the heating phase and an unsteady mixing flow in the reservoir during the cooling phase. It is shown that thermal instabilities play an important role in breaking up the residual circulation and initiating a reverse flow circulation in deep waters after the switch of thermal forcing from heating to cooling. Moreover, the heating from the water surface results in a stable large-scale convective roll that is clearly observed in the experiment. The present flow visualization is carried out with the application of thermo-chromic liquid crystals. Quantitative temperature and velocity fields are extracted using Particle Image Thermometry and Particle Image Velocimetry techniques. Understanding of the flow mechanisms pertinent to this problem is important for predicting the transport of nutrients and pollutants across reservoirs.  相似文献   

5.
Particle suspension characteristics are predicted computationally in a stirred tank driven by a Smith turbine. In order to verify the hydrodynamic model and numerical method, the predicted power number and flow pattern are compared with designed values and simulated results from the literature, respectively. The effects of particle density, particle diameter, liquid viscosity and initial solid loading on particle suspension behavior are investigated by using the Eulerian–Eulerian two-fluid model and the standard k? turbulence model. The results indicate that solid concentration distribution depends on the flow field in the stirred tank. Higher particle density or larger particle size results in less homogenous distribution of solid particles in the tank. Increasing initial solid loading has an adverse impact on the homogeneous suspension of solid particles in a low-viscosity liquid, whilst more uniform particle distribution is found in a high-viscosity liquid.  相似文献   

6.
 A conjugate numerical model proposed by Nakayama et al. for the steady problem of cooling a fluid flowing through a coiled tube, has been successfully extended to investigate two distinctive thermal problems, namely, the transient cooling processes associated with a beer dispenser, and the transient processes of heat storage and recovery associated with a packed bed saturated with a molten salt. An axisymmetric numerical procedure is adopted for determining the velocity and temperature fields within the chilled water bath of the beer dispenser. A simplified one-dimensional heat transfer model is introduced for coupling the tube flow with the recirculating flow in the bath. A similar axisymmetric finite difference procedure is applied for the heat transfer analysis of the packed bed saturated with a molten salt. For the heat recovery process, a one-dimensional heat balance equation for the two-phase flow with a helically-coiled tube is introduced to update the wall surface temperatures, which are needed to calculate the temperature field in the saturated packed bed. The numerical results for both thermal systems associated with coiled tubes agree very well with the corresponding velocity and temperature data obtained from the experiments. Received on 28 August 2000 / Published online: 29 November 2001  相似文献   

7.
The hot water storage tank (for stratified thermal storage) with a heat pump draws a lot of attention nowadays due to its high performance. In Japan, reheating of the bath is commonly used, and as this mode, the jet injects horizontally at the middle of the tank, so the temperature distribution of the tank changes complexly with time. Hence a model is needed to simulate this phenomenon, precisely. Additionally, in the process of designing a hot water storage system, it is necessary to simulate temperature distribution quickly, since a test run itself is a time consuming process.In this study, visualization experiments were performed using tracer particles and thermo-sensitive liquid crystals. Experiments were also carried out to find the unsteady temperature distribution in a tank when the positively or negatively buoyant jet was injected horizontally in the middle of the tank whose size is limited and has an influence from the opposite wall.If the momentum effect of the buoyant jet is stronger than that of buoyancy, the buoyant jet impinge against the opposite wall of the tank, and a vortex was observed near the opposite wall. Empirical formulas were proposed to predict the height of the vortex “Zb” under various conditions, such as the momentum and the buoyancy of the buoyant jet, and the Prandtl number of the tank water. Furthermore, the 3D-CFD was carried out to supplement the 3D behavior of the inner tank fluid.A one dimensional model, “uniformly distributed injection model”, for simulating temperature distribution was proposed. The performance of the model was verified by comparing the results with the unsteady temperature distribution obtained experimentally. The model was also compared with the measurements obtained using a commercially available hot water storage system. Both results showed good agreements. Hence adequacy of the model was clarified.  相似文献   

8.
Heat Transfer and Gas Flow through Feed Stream within Horizontal Pipe   总被引:4,自引:0,他引:4  
Guoxin  Hu  Wei  Xu  Yaqin  Liu 《Transport in Porous Media》2003,52(3):371-386
In the feeding process, the feed stream forms a moving packed bed of particle from the feedstock in the feed channel. When the feeding is at emergency interruption especially in the case of flooding and uncontrollable discharge, the hot gases from reactor would infiltrate into the feed stream. The high heat penetration into feed stream would affect the feeder performance. In this paper, transient thermal response of feed stream within horizontal pipe is described mathematically with a gas flow and heat transfer model. Influences of varied factors on the thermal penetration into feed stream are examined for different conditions. The temperature of the packed-bed particles and the gas velocity distribution curves are obtained for the feeding service at interruption and at normal operating conditions. The numerical results show that the thermal penetration to the packed-bed particles by the seepage flow fluid is high only in the position near the gas entrance. The thermal penetration depth tends to increase with the seepage flow velocity and decrease with feeding rate. There is no appreciable thermal penetration in the feed stream when the feeding service is at normal running. The operating conditions and the porosity of solid bed have importance effects on the gas velocity and temperature field in the thermal penetration zone. A test system is set up to determine the transient thermal response experimentally for the packed bed of particles within a horizontal pipe. The model results are found to compare favorably with the experimental data.  相似文献   

9.
The problem of laminar fluid flow,which results from the stretching of a vertical surface with variable stream conditions in a nanofluid due to solar energy,is investigated numerically.The model used for the nanofluid incorporates the effects of the Brownian motion and thermophoresis in the presence of thermal stratification.The symmetry groups admitted by the corresponding boundary value problem are obtained by using a special form of Lie group transformations,namely,the scaling group of transformations.An exact solution is obtained for the translation symmetrys,and the numerical solutions are obtained for the scaling symmetry.This solution depends on the Lewis number,the Brownian motion parameter,the thermal stratification parameter,and the thermophoretic parameter.The conclusion is drawn that the flow field,the temperature,and the nanoparticle volume fraction profiles are significantly influenced by these parameters.Nanofluids have been shown to increase the thermal conductivity and convective heat transfer performance of base liquids.Nanoparticles in the base fluids also offer the potential in improving the radiative properties of the liquids,leading to an increase in the efficiency of direct absorption solar collectors.  相似文献   

10.
Air and water velocity fields have been simulated during natural convection, using a two-dimensional volume of fluid (VOF) model. The results have shown that during unstable thermal stratification, the root-mean-square (RMS) airside velocities are an order of magnitude higher than the RMS waterside velocities, whereas, during the stable thermal stratification, the velocity magnitudes are comparable for air and water sides. Furthermore, the magnitude of the air velocity changed more rapidly with the change in the bulk air–water temperature difference than the water velocity, indicating that the air velocities are more sensitive to the bulk air and water temperature difference than the water velocities. A physical model of the heat and mass transfer across the air–water interface is defined. According to this model, the vortices on the air and water sides play an important role in enhancing the heat and mass transfer. Due to the significance of the flow velocities in the transport process, it has been proposed that the correlations for the heat and mass transfer during natural convection should be improved by incorporating the flow velocity as a parameter.  相似文献   

11.
The problem of the long established thermal stratification discrepancy between numerical and experimental results is investigated in three companion articles. The Part I article establishes reference solutions by means of three-dimensional (3D) spectral direct numerical simulations of a buoyancy-driven flow (RaH = 1.5 × 109). Two configurations of differentially heated air-filled cavity are considered: an idealized cavity (perfectly adiabatic cavity, PAC) and an Intermediate Realistic Cavity (IRC) making use of experimentally measured temperature distributions (Salat, 2004) on its top and bottom walls. The IRC flow structure as well as its associated rms fluctuations correspond to the experimentally observed flow dynamics. However both configurations keep resulting in a core thermal stratification value equal to 1.0 whereas experiments lead to a stratification of about 0.5. It is proved that this stratification paradox is neither related to three-dimensional effects nor to the experimental thermal distributions applied on the horizontal walls. Resolving this stratification discrepancy is the subject of the parts II and III articles (Sergent et al., 2013, Xin et al., 2012).  相似文献   

12.
An experimental and numerical study has been made of transient natural convection of water freezing in a cube-shaped cavity. The effect of the heat transfer through the side walls is studied in two configurations: with the cavity surrounded by air and with the cavity immersed in an external water bath of constant temperature. The experimental data for the velocity and temperature fields are obtained using liquid crystal tracers. The transient development of the ice/water interface is measured. The collected data are used as an experimental benchmark and compared with numerical results obtained from a Finite-difference code with boundary fitted grid generation. The computational model has been adopted to simulate as closely as possible the physical experiment. Hence, fully variable fluid properties are implemented in the code, and, to improve modelling of the thermal boundary conditions, the energy equation is also solved inside the bounding walls. Although the general behaviour of the calculated ice front and its volume matches observations, several details of the flow structure do not. Observed discrepancies between experimental and numerical results indicate the necessity of verifying and improving the usual assumptions for modelling ice formation.  相似文献   

13.
In this work it is presented a transient, one-dimensional, adiabatic model for slug flow simulation, which appears when liquid (mixture of oil and water) and gas flow simultaneously through pipes. The model is formed by space and time averaged conservation equations for mass, momentum and energy for each phase, the numerical solution is based on the finite difference technique in the implicit scheme. Velocity, pressure, volumetric fraction and temperature profiles for both phases were predicted for inclination angles from the horizontal to the vertical position (unified model) and ascendant flow. Predictions from the model were validated using field data and ten correlations commonly used in the oil industry. The effects of gas heating or cooling, due to compression and expansion processes, on the predictions and numerical stability, were studied. It was found that when these effects are taken into account, a good behavior of temperature predictions and numerical stability are obtained. The model presents deviations lower than 14% regarding field data and it presents better predictions than most of the correlations.  相似文献   

14.
We present heterodyne detected transient grating measurements on water filled Vycor 7930 in the range of temperature 20-90 °C. This experimental investigation enables to measure the acoustic propagation, the average density variation due to the liquid flow and the thermal diffusion in this water filled nano-porous material. The data have been analyzed with the model of Pecker and Deresiewicz which is an extension of Biot model to account for the thermal effects. In the whole temperature range the data are qualitatively described by this hydrodynamic model that enables a meaningful insight of the different dynamic phenomena. The data analysis proves that the signal in the intermediate and long time-scale can be mainly addressed to the water dynamics inside the pores. We proved the existence of a peculiar interplay between the mass and the heat transport that produces a flow and back-flow process inside the nano-pores. During this process the solid and liquid dynamics have opposite phase as predicted by the Biot theory for the slow diffusive wave. Nevertheless, our experimental results confirm that transport of elastic energy (i.e. acoustic propagation), heat (i.e. thermal diffusion) and mass (i.e. liquid flow) in a liquid filled porous glass can be described according to hydrodynamic laws in spite of nanometric dimension of the pores. The data fitting, based on the hydrodynamic model, enables the extraction of several parameters of the water-Vycor system, even if some discrepancies appear when they are compared with values reported in the literature.  相似文献   

15.
Numerical investigation of transpiration and ablation cooling   总被引:2,自引:0,他引:2  
To predict the integral performance of transpiration and ablation cooling during the reentry of hypersonic vehicles, an unsteady numerical model based on the assumption of thermal equilibrium is presented. The non-thermal equilibrium model and the thermal equilibrium model are coupled by the effective thermal properties of the porous matrix and the coolant. The calculation using the thermal equilibrium model shows the influence of the variation of the effective thermal properties on the numerical results by a comparison between constant and variable thermal properties. The comparison indicates that near the melting temperature of the porous matrix, the position of the moving boundary due to ablation is sensitive to the temperature, therefore, the variation of the thermal properties are considered in this paper. The process of ablation and transpiration cooling is simulated under different numerical conditions. The simulations demonstrate that the injection rate of coolant mass flow and initial temperature of cooling are important parameters for the control of the ablation process.  相似文献   

16.
The dynamic behavior of a horizontal boiling channel with a surge tank is investigated through nonlinear analysis. The model involves a surge tank that is subject to inlet mass flow rate and a constitutive model containing a cubic nonlinearity is used to describe the outlet pressure-flow rate relation of the downstream boiling regime. The model also includes boiling heat transfer process and incorporates the effect of the wall thermal capacity which allows the temperature and heat transfer coefficient of the heater wall to vary with time. Within certain operating regimes, the model exhibits self-excited periodic oscillations, which can be identified with pressure-drop oscillations. In this study, these oscillations are described as relaxation oscillation and the qualitative features of the response can be understood in terms of the underlying model. Finally, the present model is compared with the experimental data available in literature to investigate that transient effects of temperature heater walls, pressure, and mass flow rate.  相似文献   

17.
固体火箭燃气射流驱动液柱过程的CFD分析   总被引:1,自引:0,他引:1  
王健  阮文俊  王浩  张磊 《爆炸与冲击》2017,37(2):186-193
固体火箭燃气射流驱动液柱过程会产生一个复杂的非稳态多相流场,为了研究液柱对固体火箭发动机工作过程中射流流场的降温效果,并揭示燃气冲击液柱的流动演化和气水之间的相互作用,利用FLUENT软件中耦合了液态水汽化方程的VOF多相流计算模型对燃气与液柱之间的耦合流动及相变过程进行了数值模拟,并与无液柱情况下射流流场的计算结果进行了对比分析。计算结果表明,当有液柱平衡体时射流流场中的压力、温度、速度波动幅度均减小,减弱了射流流场中的湍流脉动强度;液柱与燃气之间的汽化以及液柱的阻碍作用减小了射流流场的轴向发展位移,尾管后的完全发展射流流场核心区域内的压力峰值降低了0.9 MPa,温度峰值降低了503 K,速度峰值降低了291 m/s,验证了实验中液柱对燃气射流流场的降温效果。  相似文献   

18.
In the case of turbine combustors operating with liquid fuel the combustion process is governed by the liquid fuel atomization and its dispersion in the combustion chamber. By highly unsteady flow field conditions the transient interaction between the liquid and the gaseous phase is of interest, because it results in a temporal variation of air–fuel ratio which leads to a fluctuating temperature distribution. The objective of this research was the investigation of transient flow field phenomena (e.g. large coherent structures) on droplet dynamics and dispersion of an isothermal flow (of inert water droplets) as a necessary first step towards a full analysis of spray combustion in real-life devices. The advanced injector system for lean jet engine combustors PERM (Partial Evaporated Rapid Mixing) was applied, generating a dilute polydispersed spray in a swirled flow field. Experiments were performed using Phase Doppler Anemometry (PDA) and a patternator to determine the droplet polydispersity, concentration maps, and velocity profiles in the flow. An important finding is the effect of large-scale coherent structures due mainly to the precessing of the vortex core (PVC) of the swirling air jet on the particle dispersion patterns. The experimental results then serve as reference data to assess the accuracy of the Eulerian–Lagrangian computations using a Large Eddy Simulation (LES), a Unsteady Reynolds-Average Navier–Stokes Simulation (URANS) and two simplified (steady-state) simulations. There, a simplified droplet injection model was used and the required boundary conditions of injected droplet sizes were obtained from measurements. Important transient effects of deterministic droplet separation observed during experiments, could be perfectly replicated with this injection model. It is convincingly shown, through extensive computations, that the resolution of instantaneous vortical structures is indeed crucial; hence the LES, or a reasonably-well resolved URANS are preferred over the steady-state solutions with additional, stochastic-type, turbulent dispersion models.  相似文献   

19.
半浮区液桥热毛细振荡流   总被引:1,自引:0,他引:1  
唐泽眉  阿燕  胡文瑞 《力学学报》1999,31(4):415-422
采用非定常、三维直接数值模拟方法研究大Pr数半浮区液桥热毛细对流从定常流向振荡流的过渡过程.文中详细描述了热毛细振荡流的起振和振荡特征,给出了液桥横截面上振荡流的流场和温度分布.在地面引力场条件下计算的结果与地面实验的结果进行比较,得出液桥水平截面上的流场和温度分布图样以一定的速度旋转,自由表面固定点处流体的环向流速正、负交替变化的一致结论.  相似文献   

20.
The thermal behavior of an integrated collector storage solar water heater (ICSSWH) is numerically studied using CFD simulations. Based on the good agreement between the numerical results and the experimental data from literature, we propose a geometrical change allowing limiting the main disadvantage of this solar system which is its high night losses due to the non-insulated storage tank surface. A second 3D CFD model of an ICSSWH in which the storage tank is partially insulated is developed and three values of this tank thermal insulated fraction are studied. Numerical results show that the partially insulated tank based ICSSWH presents lower thermal losses during the night and this night thermal losses coefficient is reduced from 14.6 to 11.64 W K?1 for the tank thermal insulation fraction τ = 1/4. Similarly, the modified system presents the advantage of its lower thermal losses even during the day. Regarding the thermal production, it is seen that the modified system presents higher water temperature at night and that for all the tank thermal insulation fractions. Concerning the operation of this modified system during the day, the water temperature is lower during the day and that up to 16 h but the water temperature which achieves 324 K for the storage tank thermal insulation fraction τ = 1/8 still sufficiently high to satisfy a family hot water needs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号