首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Szekely L  Freitag R 《Electrophoresis》2005,26(10):1928-1939
In this paper, we investigate the phenomenon of electroosmosis as a means to propel a mobile phase, in particular in view of an application in microfluidic systems, which are characterized by significantly smaller volumes of the reservoirs and the separation channels compared to conventional instrumentation. In the microfluidic chip, pH changes due to water electrolysis quickly showed an effect on the electroosmotic flow (EOF), which could be counteracted by either regularly exchanging or buffering the mobile phase. Surface treatment was of no effect in regard to EOF stabilization in empty channels but may have an influence in channels filled with a charged monolith. In fused-silica capillaries the EOF was generally found to decrease from 'naked' to surface-treated to monolith-filled capillaries. The EOF tended to be higher when an organic solvent (acetonitrile) was added to the mobile phase and could be further increased by substituting the water with equal amounts of methanol. In addition, the hydrostatic pressure exerted by the EOF was investigated. In a microfluidic chip with empty (cross-)channels such an effect could be responsible for a redirection of the flow. In capillaries partially filled with a noncharged (non-EOF-generating) monolith, a linear relationship could be established between the EOF created in the empty section of the capillary (apparent mobility) and the length of the monolith (backpressure). In capillaries partially filled with a charged (EOF-producing) monolith, flow inhomogeneities must be expected as a consequence of a superimposition of hydrodynamic pressure and EOF as mobile phase driving force.  相似文献   

2.
Polyimide HPLC‐Chip devices containing poly(methylstyrene‐bis‐p‐vinylphenyl)ethane (MS/BVPE) stationary phase within the device channels and with wall attachment were prepared by thermally initiated free radical polymerization. The microfluidic devices were coupled to both UV and MS detectors. The potential of the MS/BVPE monolith as an alternative separation media within chip devices was investigated by side‐by‐side comparisons to particulate media within commercial devices. The chromatographic behavior of this stationary phase was comparable to particulate media for separations of proteins as the average peak width at half‐height was equal (6.2 s) for a separation within 8 min under gradient elution conditions. The ability to control the porosity characteristics of the MS/BVPE monolith with changes in polymerization time also extended its utility into small analyte (< 500 Da) applications, although more optimization is needed to match conventional RP media for these applications. The good mechanical stability of the MS/BVPE monolith within the microdevices enabled excellent run‐to‐run repeatability (%RSD retention time (? 0.16) and chip‐to‐chip reproducibility (%RSD retention time (1.4). The use of this material within enrichment channels also shows its potential value in more complex work flows.  相似文献   

3.
Bedair M  Oleschuk RD 《The Analyst》2006,131(12):1316-1321
An affinity porous polymer monolith is utilized as a nanoelectrospray emitter as well as an online affinity capture column for the preconcentration of glycans. Porous polymer monolith (PPM) assisted electrospray provides a facile methodology for coupling microfluidics to mass spectrometry that is sheathless and with zero dead volume. Affinity PPM was photopolymerized using glycidyl methacrylate/ethylene dimethacrylate utilizing different porogenic solvents based on aliphatic alcohols to provide PPMs with a variety of pore sizes. The use of longer alkyl chain alcohols decreased the pore size of the formed PPM as indicated by the higher flow back pressure generated. The effect of the pore size on the stability of the electrospray was tested showing higher stability of the TIC with lower pore size. A lectin, namely Concanavaline A, was immobilized on glycidyl methacrylate/ethylene dimethacrylate using the Schiff base method to provide an affinity monolith for high mannose glycans. The amount of the lectin immobilized was studied as a function of the porogenic solvent used in the polymerization. The glycopeptides of the glycoprotein Ribonuclease B was preconcentrated on the affinity PPM sprayer and detected by tandem MS.  相似文献   

4.
Monolithic capillary columns (320 microm I.D.) were prepared for capillary liquid chromatography (CLC) by radical polymerization of butylmethacrylate (BMA) and ethylenedimethacrylate (EDMA) in the presence of a porogen solvent containing propan-1-ol, butane-1,4-diol and water. The influence of the contents of the porogen solvent and EDMA in the polymerization mixture on the monolith porosity and column efficiency was investigated. The composition of the polymerization mixture was optimized to attain a minimum HETP of the order of tens of microm for test compounds with various polarities. The separation performance and selectivity of the most efficient monolithic column prepared was characterized by van Deemter curves, peak asymmetry factors and Walters hydrophobicity and silanol indices. It was demonstrated that the 320-microm I.D. monolithic column exhibited CLC separation performance similar to that observed for 100- and 150-microm I.D. monolithic columns reported in the literature; moreover, the 320-microm I.D. column was easier to operate in CLC and exhibited a higher sample loadability.  相似文献   

5.
A urea-formaldehyde resin (UF) continuous bed has been prepared through in-situ condensation polymerization in a confined tube. The monolith is an agglomerate of 2-microm irregular particles. Nitrogen adsorption shows that the monolith has a bimodal pore size distribution. It has low resistance to flow. A dyed monolith is obtained through modification of the UF monolith with Cibacron blue F3GA. Although its dye concentration and dynamic capacity are low compared to Sepharose type affinity media, the dyed monolith can separate some proteins in the affinity mode of liquid chromatography.  相似文献   

6.
The methods for the determination of some heavy PAH in different objects by HPLC method with fluorescence detection have been developed. The following conditions for the separation of PAH have been chosen:The column 150 mm length, internal diameter 2.1 mm filled by reversible-phase sorbent Zorbax ODS (5 μ),mobile phase acetonutrile/water (80:20), the injected volume of sample concentrate 10 μ L, the velocity of mobile phase 200 μ L.min. The excitation region is 290-300 nm, the emission one is 350-420 nm. Under condition chosen the limit of detection are 5 pg for benz(a)pyrene,10 pg for pyrene and chrysene3 pg for benz(k)fluoranthene, and 20 pg for anthracene. The dynamic range is 3 order of magnitude. The reproducibility of peak highs is better than 5%.  相似文献   

7.
Various UV-laser-induced fluorescence detection strategies for capillary electrophoresis (CE) are compared, i.e. two UV-laser systems (a pulsed laser providing up to 25 mW of tunable emission, applied at 280, 290 and 325 nm, and a continuous wave (cw) laser providing up to 100 mW of 257 nm emission) and different methods to collect the fluorescence emission signal and to reduce the background. Attention is focused on the determination of amino- and hydroxy-substituted naphthalene sulphonates (NS) in river water; these analytes exhibit native fluorescence upon UV excitation. Optimum results were obtained by applying only a minor portion of the available (average) laser powers, viz. 0.7 mW at 280 nm for the pulsed laser, and 5 mW for the cw laser. For emission collection, the most favourable results were obtained with a mirror-based microscope objective, which facilitates efficient spatial filtering and does not produce impurity fluorescence upon UV-laser irradiation. For standard solutions, the cw laser gave around 20-fold better detection limits (10−9–10−10 M) than the pulsed laser. For river water, excitation of interferences (presumably humic acids, which exhibit native fluorescence) could be much better suppressed if the pulsed laser was used with selective excitation at 280 nm. Therefore, for real-sample analysis the latter combination is to be preferred. The set-up was used for the identification and quantification (at the 1–35 μg l−1 level) of NS in a river Elbe sample.  相似文献   

8.
This paper presents a microfluidic chip for highly efficient separation of red blood cells (RBCs) from whole blood on the basis of their native magnetic properties. The glass chip was fabricated by photolithography and thermal bonding. It consisted of one inlet and three outlets, and a nickel wire of 69-microm diameter was positioned in the center of a separation channel with 149-microm top width and 73-microm depth by two parallel ridges (about 10 microm high). The two ridges were formed simultaneously during the wet etching of the channels. The nickel wire for generating the magnetic gradient inside the separation channel was introduced from the side of the chip through a guide channel. The external magnetic field was applied by a permanent magnet of 0.3 T placed by the side of the chip and parallel to the main separation channel. The RBCs were separated continuously from the 1:40 (v/v) diluted blood sample at a flow rate in the range 0.12-0.92 microL/min (9-74 mm/min) with the chip, and up to 93.7% of the RBCs were collected in the middle outlet under a flow rate of 0.23 microL/min. The cell sedimentation was alleviated by adjusting the specific density of the supporting media with bovine serum albumin. Quantum dot labeling was introduced for visual fluorescence tracking of the separation process. The uneven distribution phenomenon of the blood cells around the nickel wire was reported and discussed.  相似文献   

9.
Laser-induced fluorescence (LIF) detection in conventional-size column liquid chromatography is achieved at 257 nm with a frequency-doubled argon-ion laser. Short-wavelength excitation offers two important advantages: firstly, a wide variety of analytes can be excited, and secondly, the Raman scatter of the eluent does not interfere with the fluorescence of the analytes. A standard mixture of polynuclear aromatic hydrocarbons was studied, both with LIF detection and with a commercially available sensitive conventional fluorescence detector. The improvement in the detection limits ranges from about a factory of 4 to 30; the LIF detection limits are typically at the 50 ng l?1 level, which corresponds to an injected amount of 0.5 pg.  相似文献   

10.
Capillary electrochromatography (CEC) with laser-induced fluorescence (LIF) detection was investigated for the analysis of acidic and neutral impurities in heroin. The phenanthrene-like heroin impurities exhibit high native fluorescence when excited with a doubled argon ion laser (operating at 257 nm). The limit of detection for acetylthebaol is 66 pg ml(-1). CEC-LIF analysis of heroin samples of different geographical origin gave distinguishable peak-enriched chromatograms. A sulfonic acid C12 polymer monolith column provided similar resolving power to a 1.5 mm non-porous ODS column for the isocratic analysis of a refined heroin sample. Analysis of a crude heroin sample via a multi-step gradient CEC resolved a significantly higher number of peaks than gradient high-performance liquid chromatography or micellar electrokinetic capillary chromatography.  相似文献   

11.
Ion chromatography on-chip   总被引:3,自引:0,他引:3  
On-chip separation of inorganic anions by ion-exchange chromatography was realized. Micro separation channels were fabricated on a silicon wafer and sealed with a Pyrex cover plate using standard photolithography, wet and dry chemical etching, and anodic bonding techniques. Quaternary ammonium latex particles were employed for the first time to coat the separation channels on-chip. Owing to the narrow depths of the channels on the chip, 0.5-10 microm, there were more interactions of the analytes with the stationary phase on the chip than in a 50-microm I.D. capillary. With off-chip injection (20 nl) and UV detection, NO2-, NO3-, I-, and thiourea were separated using 1 mM KCl as the eluent. The linear ranges for NO2- and NO3- are from 5 to 1000 microM with the detection limits of 0.5 microM.  相似文献   

12.
A novel microfluidic chip with simple design, easy fabrication and low cost, coupled with high-sensitive laser induced fluorescence detection, was developed to provide continuous single-cell analysis based on dynamic cell manipulation in flowing streams. Making use of laminar flows, which formed in microchannels, single cells were aligned and continuously introduced into the sample channel and then detection channel in the chip. In order to rapidly lyse the moving cells and completely transport cellular contents into the detection channel, the angle of the side-flow channels, the asymmetric design of the channels, and the number, shape and layout of micro-obstacles were optimized for effectively redistributing and mixing the laminar flows of single cells suspension, cell lysing reagent and detection buffer. The optimized microfluidic chip was an asymmetric structure of three microchannels, with three microcylinders at the proper positions in the intersections of channels. The microchip was evaluated by detection of anticancer drug doxorubicin (DOX) uptake and membrane surface P-glycoprotein (P-gp) expression in single leukemia K562 cells. An average throughput of 6–8 cells min−1 was achieved. The detection results showed the cellular heterogeneity in DOX uptake and surface P-gp expression within K562 cells. Our researches demonstrated the feasibility and simplicity of the newly developed microfluidic chip for chemical single-cell analysis.  相似文献   

13.
This article shows that there is great interest in using an electrochromatographic microchip made of hexyl acrylate (HA) based porous monolith cast within the channel of a cyclic olefin copolymer (COC) device. The monolith is simultaneously in situ synthesized and anchored to the inner walls of the channel in less than 10 min. By appropriate choice of light intensity used during the synthesis, the separation efficiency obtained for nonpolar solutes such as polycyclic aromatic hydrocarbons (PAH) is increased up to 250 000 plates/m. The performance of this HA‐filled COC microchip was investigated for a wide range of analytes of varying nature. The reversed‐phase separation of four aflatoxins is obtained in less than 2 min. The baseline separation of a mixture of neurotransmitters including six amino acids and two catecholamines is possible thanks to the superimposition of the differences in electrophoretic mobility on the chromatographic process. The durability of the system at pH 13 allows the separation of five biogenic amines and the quantitative determination of two of them in numerous wine samples. The feasibility of on‐line preconcentration is also demonstrated. Hydrophilic surface modification of COC channel via UV‐photografting with poly(ethylene glycol) methacrylate (PEGMA) before in situ synthesis of HA, is necessary to reduce the adsorption of very hydrophobic solutes such as PAH during enrichment. The detection limit of fluoranthene is decreased down to less than 1 ppb with a preconcentration of 4.5 h on the HA‐filled PEGMA functionalized COC microchip.  相似文献   

14.
电泳芯片的制作及其进样与分离   总被引:6,自引:0,他引:6  
利用微细加工技术研究在玻璃上制作电泳芯片的方法,测试了微管道的伏安特性曲线。在该电泳芯片上进行了注样和分离实验,采用激光诱导荧光法进行检测,利用CCD拍摄了进样和分离的全过程。分析了电泳芯片上施加不同的电压对样品注样的影响,给出了FITC-OH和FITC-Arg分离谱图。  相似文献   

15.
沈莹  齐莉  乔娟  毛兰群  陈义 《色谱》2013,31(4):317-321
利用两步原子转移自由基聚合(ATRP)方法,初步建立了新型聚合物整体柱固相萃取(SPE)材料制备的新方法。首先利用ATRP方法,以乙二醇二甲基丙烯酸酯(EDMA)为交联剂,在室温条件下,在滤头中原位快速聚合制备得到负载有聚合物整体柱的萃取装置;然后采用表面诱导的电子转移活化再生原子转移自由基聚合(ARGET ATRP)方法进行表面修饰,得到了聚(二甲基氨基乙基甲基丙烯酸酯)(PDMAEMA)修饰的柱体;进一步将此整体柱用作萃取材料,实现了对激素类药物的富集分析。本研究表明:ATRP有望作为一种简单、有效及反应条件温和的聚合方法用于整体柱的制备,且该方法有潜力实现固相萃取材料在不同装置中的制备。  相似文献   

16.
Water-compatible pefloxacin-imprinted monoliths synthesized in a water-containing system were used for the selective extraction of fluoroquinolones (FQs). The MIP monolith was synthesized by using methacrylic acid as the functional monomer, di(ethylene glycol) dimethacrylate as a cross-linker and methanol–water (10:3, v/v) as the porogenic solvent. The ability of the derivated MIP for selective recognition of FQs (ciprofloxacin, difloxacin, danofloxacin and enrofloxacin) and quinolones (flumequine, and oxolinic acid) was evaluated. The derivated monolith showed high selectivity and was able to distinguish between FQs and quinolones. A simple rapid and sensitive method using polymer monolith microextraction (PMME) based on the MIP monolith combined with HPLC with fluorescence detection was developed for the determination of four FQs from milk samples. Owing to the unique porous structure and flow-through channels in the network skeleton of the MIP monolith, phosphate buffer diluted milk samples were directly supplied to PMME; allowing non-specific bound proteins and other biological matrix to be washed out, and FQs to be selectively enriched. The limit of detection of the method was 0.4–1.6 ng/mL and recovery was 92.4–98.2% with relative standard deviations less than 5.9%.  相似文献   

17.
Bead-based immunoassays using a micro-chip flow cytometer   总被引:2,自引:0,他引:2  
Holmes D  She JK  Roach PL  Morgan H 《Lab on a chip》2007,7(8):1048-1056
A microfabricated flow cytometer has been developed for the analysis of micron-sized polymer beads onto which fluorescently labelled proteins have been immobilised. Fluorescence measurements were made on the beads as they flowed through the chip. Binding of antibodies to surface-immobilised antigens was quantitatively assayed using the device. Particles were focused through a detection zone in the centre of the flow channel using negative dielectrophoresis. Impedance measurements of the particles (at 703 kHz) were used to determine particle size and to trigger capture of the fluorescence signal. Antibody binding was measured by fluorescence at single and dual excitation wavelengths (532 nm and 633 nm). Fluorescence compensation techniques were implemented to correct for spectral overspill between optical detection channels. The data from the microfabricated flow cytometer was shown to be comparable to that of a commercial flow cytometer (BD-FACSAria).  相似文献   

18.
A novel fluorescence detection system for CE was described and evaluated. Two miniature laser pointers were used as the excitation source. A Y‐style optical fiber was used to transmit the excitation light and a four‐branch optical fiber was used to collect the fluorescence. The optical fiber and optical filter were imported into a photomultiplier tube without any extra fixing device. A simplified PDMS detection cell was designed with guide channels through which the optical fibers were easily aligned to the detection window of separation capillary. According to different requirements, laser pointers and different filters were selected by simple switching and replacement. The fluorescence from four different directions was collected at the same detecting point. Thus, the sensitivity was enhanced without peak broadening. The fluorescence detection system was simple, compact, low‐cost, and highly sensitive, with its functionality demonstrated by the separation and determination of red dyes and fluorescent whitening agents. The detection limit of rhodamine 6G was 7.7 nM (S/N = 3). The system was further applied to determine illegal food dyes. The CE system is potentially eligible for food safety analysis.  相似文献   

19.
This paper shows the in situ synthesis of an hexyl acrylate monolith in PDMS microfluidic devices and its subsequent use as stationary phase for electrochromatography on chip. To overcome the ability of PDMS material to absorb organic monomers, surface modification of the enclosed channels was realized by UV-mediated graft polymerization. This grafting procedure is based on the preliminary adsorption of a photoinitiator onto the PDMS surface and polymerization of charged monomers. Next, hexyl acrylate monoliths were cast in situ using photopolymerization process. The chromatographic behavior of the monolithic column was confirmed by the successful separation of derivatized catecholamines in the PDMS device using a 30 mm effective separation length (100 microm x 100 microm section). Efficiencies reached up to 200,000 plates per meter.  相似文献   

20.
Porous sol-gel frits are fabricated in a capillary column by filling it with a solution of 3-(trimethoxysilyl)propyl methacrylate, hydrochloric acid, water, toluene (porogen), and a photoinitiator (Irgacure 1800) and exposing it to UV light at 365 nm for 5 min. The separation column (30 cm x 75 microm I.D.) contains between the inlet and outlet frits a 15-cm packed segment filled with 5-microm silica particles modified with the chiral compound (S)-N-3,5-dinitrobenzoyl-1-naphthylglycine. A detection window (1 mm long) is placed immediately after the outlet frit. To demonstrate the performance of this chiral separation column, mixtures of 16 different amino acids (three of which are not naturally occurring) derivatized with the fluorogenic reagent 4-fluoro-7-nitro-2,1,3-benzoxadiazole were separated by capillary chromatography. The enantiomeric separation of the column results in a resolution ranging from 1.21 to 8.29, and a plate height ranging from 8.7 to 39 microm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏