首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A simple and reliable high-performance liquid chromatographic (HPLC) method has been developed for the determination of nodakenin in rat plasma. The concentration of nodakenin was determined in plasma samples after deproteinization with methanol using hesperidin as internal standard. HPLC analysis was performed on a Diamonsil C(18) analytical column using acetonitrile-water (25:75, v/v) as the mobile phase and a UV detection at 330 nm. This method was validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day variation). The extraction recoveries were 91.3 ± 10, 87.8 ± 4.8 and 92.6 ± 5.1 at concentrations of 0.500, 5.00 and 40.0 μg/mL, respectively. The standard curve for nodakenin was linear (r(2) ≥ 0.99) over the concentration range 0.250-50.0 μg/mL with a lower limit of quantification of 0.250 μg/mL. The intra- and inter-day precision (relative standard deviation, RSD) values were not higher than 12% and the accuracy (relative error, RE) was within ± 5.8% at three quality control levels. The validated method was successfully applied for the evaluation of the pharmacokinetics of nodakenin in rats after oral administration of Rhizoma et Radix Notopterygii decoction and nodakenin solution.  相似文献   

2.
3.
A high-performance liquid chromatographic method for the separation and determination of 18 alpha-glycyrrhetinic acid and 18 beta-glycyrrhetinic acid has been developed. Indomethacin was used as an internal standard. The drugs were separated on a reversed-phase column and detected by UV detection at a wavelength of 254 nm. Methanol-water-perchloric acid-ammonia (80:20:0.4:0.4, v/v) was used as the mobile phase at pH of 7.0-7.5. The detection limit of both compounds was 0.1 microgram/ml in rat plasma. The method was applied to pharmacokinetic studies of glycyrrhetinic acids in rats. The results suggest that the pharmacokinetics appeared to be non-linear in nature.  相似文献   

4.
An analytical method based on high-performance liquid chromatographic (HPLC) with ultraviolet (UV) detection was developed for determination of scopolin in rat plasma using aesculin as internal standard (IS). After protein precipitation of plasma sample with methanol, the supernatant was directly injected and analyzed. Chromatographic separation was achieved on a C18 column using methanol and distilled water (22:78, v/v) containing 0.2% (v/v) glacial acetic acid as mobile phase with a column temperature of 30 degrees C. The UV detector was set at 338 nm. The calibration curve was linear over the range of 0.105-13.125 microg/mL with a correlation coefficient of 0.9998. The retention times of aesculin and scopolin were 10.4 and 12.8 min, respectively. The recoveries for plasma samples of 0.105, 4.725 and 13.125 microg/mL were 91.08, 95.30 and 96.10%, respectively. The RSD of intra- and inter-day assay variations was less than 7.35%. The lower limit of detection was 0.03 microg/mL .This HPLC assay is a simple, sensitive and accurate and was successfully applied to the pharmacokinetic study of scopolin in rats.  相似文献   

5.
An improved HPLC method was developed for the determination of piperacillin and tazobactam in human plasma and pharmacokinetic study in Chinese healthy volunteers. Piperacillin and tazobactam in human plasma were extracted by solid-phase extraction and separated on a C(18) column and detected at 220 nm. The mobile phase for piepracillin consisted of 0.01 mol/L sodium dihydrogen phosphate (pH = 4.65) and acetonitrile (71:29, v/v), and that for tazobactam was 0.05 mol/L sodium dihydrogen phosphate (pH = 4.45) and methanol (90:10, v/v). The method was linear in the range 0.25-320.00 microg/mL for piperacillin (r(2) = 0.995) and 0.25-64.00 microg/mL for tazobactam (r(2) = 0.994). The lower limit of quantification of both compounds was 0.25 microg/mL. The intra- and inter-day precisions of piperacillin and tazobactam at three concentrations were all less than 9.2% and accuracies were within the range 97.0-108.0%. The method was used to investigate the pharmacokinetics of piperacillin and tazobactam in 12 volunteers who were intravenously given a dosage of 1.25, 2.50 and 3.75 g in three periods. The results showed that piperacillin sodium-tazobactom sodium (4:1) for injection in Chinese people fits linear dynamics, and the administred dosage can be adjusted with therapeutic effect.  相似文献   

6.
7.
A sensitive and specific method using liquid chromatography–electrospray tandem mass spectrometry (LC‐MS/MS) for the determination of pinaverium bromide in human plasma was developed and validated. Pinaverium bromide and an internal standard (paclitaxel) were isolated from plasma samples by precipitating plasma, and determined by LC‐MS/MS in multiple‐reaction monitoring mode. The main metabolite of pinaverium bromide and endogenous substances in plasma did not show any interference. The calibration curve was linear over the plasma concentration range of 10.0–10000.0 pg/mL with a correlation coefficient of 0.9979. The relative standard derivations intra‐ and inter‐day at 30.0, 300.0 and 8000.0 pg/mL in plasma were less than 15%. The absolute recoveries of pinaverium bromide and the internal standard were 99.7–111.7 and 106.2%, respectively. The lower limit of quantitation was 10 pg/mL. The analytical method was successfully applied to study the pharmacokinetics of pinaverium bromide tablets in healthy Chinese volunteers. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
An HPLC‐MS/MS method has been developed and validated for the determination of venlafaxine enantiomers in human plasma and applied to a pharmacokinetic study in healthy Chinese volunteers. The method was carried out on a vancomycin chiral column (5 µm, 250 × 4.6 mm) maintained at 25°C. The mobile phase was methanol–water containing 30 mmol/L ammonium acetate, pH 3.3 adjusted with aqueous ammonia (8:92, v/v) at the flow rate 1.0 mL/min. A tandem mass spectrometer with an electrospray interface was operated in the multiple reaction monitoring mode to detect the selected ions pair at m/z 278.0 → 120.8 for venlafaxine enantiomers and m/z 294.8 → 266.7 for estazolanm (internal standard). The method was linear in the concentration range of 0.28–423.0 ng/mL. The lower limit of quantification was 0.28 ng/mL. The intra‐and inter‐day relative standard deviations were less than 9.7%. The method was successfully applied for the evaluation of pharmacokinetic profiles of venlafaxine enantiomers in 18 healthy volnteers. Validation parameters such as the specificity, linearity, precision, accuracy and stability were evaluated, giving results within the acceptable range. Pharmacokinetic parameters of the venlafaxine enantiomers were measured in the 18 healthy Chinese volunteers who received a single regimen with venlafaxine hydrochloride capsules. The results show that AUC(0–∞), Cmax and t1/2 between S‐venlafaxine and R‐venlafaxine are significantly different (p < 0.05). Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
A sensitive solid-phase extraction/high-performance liquid chromatographic method with ultraviolet detection was established for the analysis of salvianolic acid B in rabbit plasma. The analyte was separated on a reversed-phase column with trifluoroacetic acid-methanol-acetonitrile (70:10:20, v/v/v) as mobile phase at a flow rate of 1 mL/min, and ultraviolet detection at 315 nm. The calibration curve for salvianolic acid B was linear over the range 35-1400 microg/L with coefficients of correlation >0.999. The inter-day and intra-day precisions of analysis were <15%, and assay accuracy ranged from 95.3 to 109.1%. This method is suitable for determining salvianolic acid B in plasma and thus investigating the pharmacokinetics of salvianolic acid B.  相似文献   

10.
A sensitive, simple and highly reliable high-performance liquid chromatographic method using fluorescence detection is reported for the determination of pindolol in plasma. This method involves a single extraction of pindolol from alkalinized plasma into methyl tert.-butyl ether followed by a back-extraction into dilute hydrochloric acid. Injection of the dilute acid phase directly onto an octyl (LC-8) bonded-phase column provides the final separation, and detection of pindolol is achieved by monitoring the intrinsic fluorescence of pindolol at 315 nm following excitation at 255 nm. The method is sensitive enough to measure with confidence pindolol plasma concentrations of 2 ng/ml using a 2-ml sample. No internal standard is required. This method has been applied to the analysis of 1500 human plasma samples by two different laboratories.  相似文献   

11.
A high-performance liquid chromatographic method for an effective determination of glafenine and its main metabolite, glafenic acid, is described. The assay involves separate extraction procedures for glafenine and for its metabolite, but the same internal standard (floctafenine) and the same chromatographic conditions (including a 5-micron C8 column, a quaternary solvent mixture of water-acetonitrile-diethylamine-acetic acid and an ultraviolet detector set at 360 nm). For 1 ml of plasma, the detection limit is 0.05 mg/l for glafenine and 0.25 mg/l for glafenic acid. Compared with previously described techniques, this assay uses a very low glafenine linearity range, which allows the true pharmacokinetics of this drug to be described for the first time.  相似文献   

12.
A new liquid chromatographic tandem mass spectrometric method for the determination of mirtazapine and demethylmirtazapine in human plasma has been developed and fully validated. The article describes in detail the bioanalytical procedure and summarizes the validation results obtained. The samples were extracted using liquid-liquid extraction with a mixture of 1-chlorobutane/isopropanol/ethyl acetate (88:2:10, (v/v/v)). The chromatographic separation was performed on a reversed-phase XTerrra MS C8 column ( i.d.; 3.5 μm particle size) using a mobile phase consisting of 0.010 M ammonium formate (pH 7.8) and acetonitrile (35:65, (v/v)), pumped at a flow rate of 0.80 ml min−1. The analytes were detected using a Finnigan LCQ advantage ion-trap mass spectrometer with positive electrospray ionization in selected reaction monitoring (SRM) mode. Tandem mass spectrometric detection enabled the quantitation of both compounds down to 0.10 ng ml−1. Calibration graphs were linear (r better than 0.990, n=11), in concentration ranges 0.10 to 200 ng ml−1 for mirtazapine demethylmirtazapine. The intra- and inter-day R.S.D. values were less than 14.8 and 16.6% for mirtazapine and demethylmirtazapine, respectively. The method was successfully applied to a kinetic study in order to assess the main pharmacokinetic parameters of mirtazapine and demethylmirtazapine.  相似文献   

13.
A highly sensitive, selective and rapid liquid chromatography–electrospray ionization mass spectrometry (LC‐MS) method has been developed and validated for simultaneous determination of moxifloxacin (MFX) and ketorolac (KTC) in rat plasma. Gemifloxacin (GFX) was used as an internal standard (IS). A simple protein precipitation method was used for the extraction of analytes from rat plasma. Effective chromatographic separation of MFX, KTC and GFX was achieved on a Kromasil C18 column (100 × 4.6 mm, 5 µm) using a mobile phase consisting of acetonitrile–10 mm ammonium acetate (pH 2.5)–0.1% formic acid (50:25:25) in an isocratic elution, followed by detection with positive ion electrospray ionization mass spectrometry using target ions of [M + H]+ at m/z 402 for MFX, m/z 256 for KTC and m/z 390 for GFX in selective ion recording mode. The method was validated over the calibration range of 5–100 ng/mL for MFX and 10–6000 ng/mL for KTC. The method demonstrated good performances in terms of intra‐ and inter‐day precision (0.97–5.33%) and accuracy (93.91–101.58%) for both MFX and KTC, including lower and upper limits of quantification. The recoveries from spiked control samples were >75% for MFX and >79% for KTC. The matrix effect was found to be negligible and the stability data were within acceptable limits. Further, the method was also successfully applied to a single‐dose pharmacokinetic study in rats. This method can be extended to measure plasma concentrations of both drugs in human to understand drug interaction and adverse effects. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
A rapid and sensitive high-performance liquid chromatographic (HPLC) method is developed for the determination of tetramethylpyrazine phosphate, an antiplatelet aggregation agent, in 100 microL of dog plasma. Sample preparations are carried out by deproteinization with an internal standard (carbamazepine) solution in acetonitrile. An aliquot of the supernatant (20 microL) is directly injected into an HPLC apparatus with methanol-phosphate buffer (0.01M, pH 3.0) (62:38, v/v) as the mobile phase at a flow rate of 1.0 mL/min. Separation is performed with a C18 column at 30 degrees C. The peak is detected using a UV detector set at 279 nm. The capacity factors are 1.48 for tetramethylpyrazine phosphate and 2.09 for carbamazepine, with a total run time of 10 min. The calibration curve is linear in the 0.2-50-microg/mL range. The limit of detection is 0.05 microg/mL. Mean recoveries are 92.6-98.1%. The within- and between-day variation coefficients are less than 4.9% and 7.5%, respectively. The present method has been successfully used to provide pharmacokinetic data after oral administration of tetramethylpyrazine phosphate pulsincap capsules and immediate-release tablets to dogs.  相似文献   

15.
A fast, sensitive, and specific liquid chromatographic/tandem mass spectrometric method was developed and validated for determination of tetracycline in human plasma. Tetracycline and oxytetracycline [internal standard (IS)] were extracted from the plasma by protein precipitation. The mobile phase consisted of acetonitrile-formic acid 0.1% (48 + 52, v/v), run at a flow rate of 1 ml/min (split 1:5). Detection was performed by positive electrospray ionization in multiple reaction monitoring mode, monitoring the transitions 444.8 > 410.0 and 461.0 > 426.0 for tetracycline and IS, respectively. The analysis was performed in 3.5 min and the method was linear in the plasma concentration range of 50-6000 ng/mL. The mean extraction recoveries for tetracycline and IS from plasma were 92.14 and 94.04%, respectively. Method validation investigated parameters such as the linearity, precision, accuracy, specificity, and stability, giving results within the acceptable range. The proposed method was successfully applied for determination of tetracycline in human plasma samples to support bioequivalence studies.  相似文献   

16.
17.
18.
A sensitive analysis of pentaerythritol in plasma has been devised, based on the formation or its tetra-p-methoxybenzoate derivative and high-performance liquid chromatography employing an ultraviolet photometric detector. The method permits analysis of pentaerythritol in the ppm range.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号