首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The protocol and various matrices were examined for quantification of biomolecules in both the low ca. 1200 amu and mid mass 6000–12000 amu ranges using an internal standard. Comparative studies of different matrices of MALDI quantitative analysis showed that the best accuracy and standard curve linearity were obtained for two matrices: (a) 2,5-dihydroxybenzoic acid (DHB) combined with a comatrix of fucose and 5-methoxysalicylic acid (MSA) and (b) ferulic acid/fucose. In the low mass range, the quantitative limit was in the 30 fmol range and in the mid mass range the quantitative limit was in the 250 fmol range. Linear response was observed over 2–3 decades of analyte concentration. The relative error of the standard curve slope was 1.3–1.8% with correlation coefficients of 0.996–0.998.The main problem for quantitative measurement was suppression of the signal of the less concentrated component (analyte or internal standard) by the more concentrated component. The effect was identified with saturation of the matrix by the analyte. The threshold of matrix saturation was found to be in the range of 1/(3000–5000) analyte/matrix molar ratio. To avoid matrix saturation the (analyte+internal standard) to matrix molar ratio should be below this threshold. Thus the internal standard concentration should be as low as possible.DHB/MSA/fucose and ferulic acid/fucose matrices demonstrated good accuracy and linearity for standard curves even when the internal standard had chemical properties different from the analyte. However, use of an internal standard with different chemical properties requires highly stable instrumental parameters as well as constant (analyte+internal standard)/matrix molar ratio for all samples.  相似文献   

2.
Sample preparation is crucial to the success of experiments in biological mass spectrometry. In proteomics, digestion of the proteins into peptides is a key step for “bottom-up” approaches. Often, the use of enzymes requires physiological conditions, producing peptides that must be extracted or further purified before mass analysis. Chemical cleavage reagents offer more flexibility and can be more compatible with downstream mass analysis. Expanding on prior work using acid hydrolysis, proteolysis with matrix-assisted laser desorption ionization (MALDI) matrices is presented. This sample preparation can be performed rapidly with a minimum of reagents and sample handling, but it must first be evaluated in terms of digestion efficiency, missed cleavages, and side reactions before implementation for in-gel digestion and in-solution digestion using minimal volumes of protein. Time courses of acid hydrolysis are shown for protein standards, illustrating the sensitivity of this type of sample preparation, minimization of side reactions, and performance for proteins in mixtures. To illustrate the potential for sensitive detection of a specific protein, MALDI matrix hydrolysis is used to digest a protein immunoprecipitated from cell lysate.  相似文献   

3.
In this report, first use of size-selected gold nanoparticles (AuNPs) as matrixes for matrix assisted laser desorption/ionization (MALDI) is described for peptides and proteins. In comparison with conventional organic acid MALDI matrixes, the optimum matrix-to-analyte ratio with AuNP matrixes is reduced by 10-14 orders of magnitude. Significant differences in the relative abundances of the ions observed in positive and negative mode MALDI-time-of-flight mass spectrometry (TOFMS) are revealed as the AuNP size distribution is decreased from 10 to 2 nm, whereby 2-nm AuNPs exhibit quantum confinement effects prevalent in quantum dots. AuNP matrixes allow for selective analyte ionization, as demonstrated in the selective MALDI-TOFMS of phosphotyrosine in a background of phosphoserine and phosphothreonine peptides.  相似文献   

4.
5.
A new technique has been developed for the formation of gas-phase electrons and ions by electric field assisted thermal desorption ionization at atmospheric pressure. Experiments were carried out using a sharp tungsten wire tip coated with a thin solid sample film which was irradiated by a 10.6 μm infrared laser. By applying a strong electric field on the laser-irradiated tungsten wire tip, abundant ions such as alkali ions, halide ions, and also multiply charged negative ions S(2)O(6)(2-) and S(2)O(8)(2-), were formed. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   

6.
7.
The need for high‐throughput methodologies providing both qualitative and quantitative information has grown substantially in the pharmaceutical laboratory in recent years. Currently, tandem mass spectrometry (MS/MS) using quadrupole technology offers analysis in the minutes time scale. The use of matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) offers the advantage of speed and automation and enables analysis in the seconds time scale with accurate mass capabilities that are not typically found in quadrupole MS/MS. However, one of the limitations of MALDI for the analysis of small molecules is the abundance of interfering matrix peaks in the low molecular weight region of the mass spectrum. Described herein is an evaluation of a pre‐prepared MALDI target plate that has been coated with a thin layer of α‐cyano‐4‐hydroxycinnamic acid (CHCA) and nitrocellulose. This modified plate has been shown to suppress or eliminate CHCA matrix signals without any significant loss of analyte sensitivity when compared with analysis of the same sample using an unmodified target plate. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

8.
A CE separation of hydrophobic peptides followed by fractionation onto a prestructured MALDI target and off-line MS analysis was performed. An improved and partially automated manufacturing procedure of the previously described MALDI target is presented. This target is structurally coated with silicone and especially developed for hydrophobic peptides and proteins. Here, the target plate was designed specifically for the CE fraction collection. Different solvents were evaluated to meet the requirements of peptide solubility and compatibility to both the CE and MALDI methods and to the fractionation procedure. CE-MALDI-MS analysis of nine highly hydrophobic peptides from cyanogen bromide-digested bacteriorhodopsin is demonstrated.  相似文献   

9.
Gas phase ions for valine, glutamate, phenylalanine, angiotensin, bradykinin, LH-RH, and bombesin were formed through matrix assisted laser desorption-ionization (MALDI) in air at ambient pressure and were characterized by ion mobility spectrometry (IMS). The IMS drift tube was operated at 100 °C with air as the drift gas and without an ion shutter. Responses were obtained using α-cyano-4-hydroxycinnamic acid as the matrix and a Nd-YAG laser at 355 nm with an unfocused beam at 6 mJ per pulse and 7 mm2 cross section. Matrix and analyte were applied to a borosilicate glass target and microgram amounts of sample provided responses lasting 10 to 15 s with the laser operated at 11 Hz. Detection limits for the peptides were estimated to be 10 to 100 pmol per laser shot. The mobility spectra for individual amino acids and peptides exhibited multiple peaks with spectral distortions and raised baselines. These features and calculated values for reduced mobilities were consistent with the existence of clusters between analyte ions and matrix neutrals and the dissociation of these clusters in the drift region of the analyzer. Mobility spectra with distinctive peaks were not obtained for MALDI-IMS of peptides larger than 5700 amu, though ion formation was suggested from the depletion of matrix signal.  相似文献   

10.
我们发展了一种利用基质辅助激光解析电离飞行时间质谱技术(MALDI-TOF MS)分析对金属离子具有较高亲和力的寡核苷酸G-四链体的方法.考察了不同基质:3-羟基吡啶甲酸(3-HPA)与柠檬酸氢二铵(DHC)混合基质、3,4-二胺基苯基苯甲酮(DABP)及DABP/DHC混合基质,应用于G-四链体分析的效果.实验结果表...  相似文献   

11.
Gold nanoparticles (AuNPs) were applied and optimized as matrix for matrix‐assisted laser desorption/ionization mass spectrometry analysis of animal tissues, and enabled histological analysis of animal tissues at molecular level by imaging mass spectrometry (IMS). AuNPs were coated on animal tissue in a solvent‐free manner via argon ion sputtering. Metabolites, including neurotransmitters, fatty acids and nucleobases, were directly detected from mouse brain tissue. Based on region‐specific chemical profiles, fine histological features of mouse brain tissue and heterogeneous regions of tumor tissue were both revealed. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

12.
A quantum dots (QDs) assisted laser desorption/ionization mass spectrometric (QDA‐LDI‐MS) strategy was proposed for qualitative and quantitative analysis of a series of carbohydrates. The adsorption of carbohydrates on the modified surface of different QDs as the matrices depended mainly on the formation of hydrogen bonding, which led to higher MS intensity than those with conventional organic matrix. The effects of QDs concentration and sample preparation method were explored for improving the selective ionization process and the detection sensitivity. The proposed approach offered a new dimension to the application of QDs as matrices for MALDI‐MS research of carbohydrates. It could be used for quantitative measurement of glucose concentration in human serum with good performance. The QDs served as a matrix showed the advantages of low background, higher sensitivity, convenient sample preparation and excellent stability under vacuum. The QDs assisted LDI‐MS approach has promising application to the analysis of carbohydrates in complex biological samples. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
The intact noncovalent structure of the homo-oligomeric complexes of streptavidin (52 kDa), alcohol dehydrogenase (150 kDa), and beef liver catalase (240 kDa) have been observed using the matrix 2,6-dihydroxyacetophenone in an organic solvent. Intact streptavidin tetramers could also be observed with ferulic acid and other hydroxyacetophenone derivatives. Intact complexes are observed only for the first shot at a given position, which may be due to physical segregation or precipitation of the noncovalent complexes at the crystal surface. This effect is independent of the macroscopic crystal structure or the type of substrate (hydrophobic versus hydrophilic). Observation of intact complexes is not affected by addition of less than 10 mM salts or buffers, and appears to be independent of the pH stability range of the protein samples investigated.  相似文献   

14.
15.
We report quantitative MALDI-TOF measurements for polydimethylsiloxane (PDMS) of two different molecular weights using the relative ratio of the signal intensities of integrated oligomer distributions for these two molecular weight distributions. By reporting the ratio of intensities of the integrals of two oligomer distributions, we assume that the ionization and desorption efficiencies, crystallization conditions and other factors affecting intensity are similar. Poly(methyl methacrylate) (PMMA-33,000) was mixed with PDMS samples to show whether the presence of another material might affect the desorption efficiency. Quantitative values for the number-average molecular weight (Mn), weight-average molecular weight (Mw) and polydispersities (D) were calculated using the oligomer distributions. The results show a linear relationship between the analyte concentrations and the signal intensities in the range from 1,000 Da to 10,000 Da, and the desorption efficiency of these two PDMS materials was the same even in the presence of PMMA.  相似文献   

16.
This work presents several critical details for making cIEF-MALDI-MS a robust technique which will allow for more routine application and aid in automation. This includes emphasis on the hardware necessary for syringe pump mobilization and proper protocol for preventing disruption from gas bubbles. Following these guidelines, excellent elution time reproducibility is demonstrated for six pI markers (RSD <5%). Additionally, the pI markers are used to calibrate the pH gradient and determine experimental pIs of proteins detected offline by mass spectrometry. This was demonstrated using a standard protein mixture of myoglobin and two forms of β-lactoglobulin. Experimental determination of protein pIs and molecular weights were found to be in agreement with literature values. The technical details discussed provide a sound foundation for applying the offline coupling of MALDI-MS with cIEF.  相似文献   

17.
Cheng YC  Chen KH  Wang JS  Hsu WL  Chien CC  Chen WY  Tsao CW 《The Analyst》2012,137(3):654-661
This study developed a rapid, sensitive, and matrix-free method for the determination of amphetamine (AMP), methamphetamine (MA), codeine (COD), morphine (MOR), and ketamine (KET) using nanostructured silicon surface assisted laser desorption/ionization mass spectrometry (nSi-MS). The nanostructured silicon (nSi) chip used in this study was created by employing the metal-assisted etching process. Drug standard tests were applied to the nSi chip platform to evaluate the nSi-MS performance, including detection sensitivity, limit of detection, linearity, and repeatability. Real urine samples obtained from drug addict detainees were directly applied to the nSi chip for drug analysis. By observing the nSi-MS spectra, the target drug peaks can be identified; and an antibody pull-down assay was performed to confirm the specificity of the detected targets. nSi-MS drug quantification was assayed, yielding comparable results with those from using the GC-MS approach. The advantages of applying nSi-MS to analyze AMP, MA, COD, MOR, and KET in the urine of addicts are simple, extremely small urine volumes (~10 μL), and a fast analysis procedure (<15 minutes).  相似文献   

18.
19.
Gold nanoparticles (AuNPs) have been studied as a potential solid-state matrix for laser desorption/ionization mass spectrometry (LDI-MS) but the efficiency in ionization remains low. In this report, AuNPs are capped by a self-assembled monolayer of cysteamine and modified with α-cyano-4-hydroxycinnanic acid (CHCA) for effective MALDI measurements. CHCA-terminated AuNPs offer marked improvement on peptide ionization compared with citrate-capped or cysteamine-capped AuNPs. The coating also effectively suppresses formation of Au cluster ions and analyte fragment ions, leading to cleaner mass spectra. Addition of glycerol and citric acid to the peptide/AuNPs sample further improves the performance of these AuNPs for LDI-MS analysis. Glycerol appears to enhance the dispersion of AuNPs in sample spots, increasing the sample ionization and shot-to-shot reproducibility, while citric acid serves as an external proton donor, providing high production of protonated analyte ions and reducing fragmentation of peptides on the nanoparticle-based surface. Optimal ratios of citric acid, glycerol, and AuNPs in sample solution have been systematically studied. A more than 10-fold increase for desorption ionization of peptides can be achieved by combining 5% glycerol and 20 mM citric acid with the CHCA-terminated AuNPs. The applicability of the CHCA-AuNPs for LDI-MS analysis of protein digests has also been demonstrated. This work shows the potential of AuNPs for SALDI-MS analysis, and the improvement with chemical functionalization, controlled dispersion, and use of an effective proton donor.  相似文献   

20.
Monovalent cations often associate with peptides and proteins under mass spectrometry (MS) conditions, resulting in a discernable, but often misleading, adduct cluster pattern. These adduct cluster peaks reduce the signal intensity of specific peptide species by splitting the ion population into multiple mass peaks, suppressing the ionization of neighboring low-abundance peaks, and interfering with identification of post-translational modifications. Further, monovalent contaminants tend to form a distribution of matrix cluster peaks in matrix-associated laser desorption/ionization time-of-flight (MALDI-TOF) spectra causing interference and suppression in the mass range below 1400 Da. The most common method for reduction or elimination of adduct clusters is solid-phase extraction via a pipette tip or spin column, which often leads to loss of low-abundance peptide components. In this study we describe the use of a commercially available surfactant blend that markedly reduces the adduction of monovalent cations during peptide analysis by MALDI-TOFMS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号