首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents a comparison of triple quadrupole tandem mass spectrometry (MS/MS) and Orbitrap high‐resolution mass spectrometry (HRMS) combined to ultrahigh performance liquid chromatography for the determination of glucocorticoids and polyether ionophores in sewage, in order to show the major benefits and drawbacks for each mass spectrometry analyser. Overall, HRMS measurements have enhanced performance in terms of confirmatory capabilities than MS/MS measurements. Moreover, similar limits of quantification, limits of detection, linear range and repeatability for glucocorticoids with both the MS/MS and HRMS methods were compared, but in the case of polyether ionophores, slightly better limits of detection and limits of quantification were obtained with the HRMS method because of the high sensitivity obtained when diagnostic ions are used for quantification instead of selected reaction monitoring transitions for these compounds. The two methods have been applied to the analysis of several influent and effluent sewage samples from sewage treatment plants located in the Tarragona region (Catalonia, Spain), showing an excellent correlation between the two methods. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
Summary Electron capture detection (ECD), low- and highresolution mass spectrometry (LR- and HRMS), and atomic emission detection (AED) were compared for the gas chromatographic (GC) detection of polychlorinated biphenyls (PCBs) present in highly contaminated marine sediments. With ECD, LRMS, and even HRMS, detection was seriously disturbed by the complex matrix of the sediments, whereas AED in the chlorine-selective mode provided excellent PCB profiles without interferences. In addition, GC-AED provided congener independent responses, which enabled accurate quantitation of all PCBs based on a single calibration curve. However, because GC-AED was less sensitive than the other techniques studied, preparation of relatively large amounts of sample (10–20 g dry sediment) was required for most analyses.  相似文献   

3.
Some aspects of both sample preparation and instrumental techniques for analysis of such acidic drugs as acetylsalicylic acid, ibuprofen, gemfibrozil, fenoprofen, naproxen, ketoprofen, and diclofenac, as well as caffeine in surface water and municipal wastewater have been studied and further developed. Water samples were filtered and target analytes were extracted by solid-phase extraction (SPE). Supelco LC-18 and Oasis HLB SPE cartridges were used to pre-concentrate samples for acidic drugs and caffeine, respectively. A methylation process was applied to acidic drugs prior to analysis while caffeine was analyzed directly. A method of gas chromatography-ion trap tandem mass spectrometry (IT-MS/MS) for analysis of the target acidic pharmaceuticals and caffeine is presented here in detail. Such parameters as collision-induced dissociation (CID) voltage, isolation time, excitation time, excitation storage level, and electron energy were adjusted in order to optimize the instrument analytical performance. After optimization, an instrument detection limit of 0.5-20 pg/microL with signal-to-noise (S/N) not less than 5 was achieved for all target analytes. It was shown that this method has good linearity within the range of 10-2000 pg/microL. The application of the optimized IT-MS/MS parameters conjointly with the sample preparation procedure resulted in method detection limits (MDLs) of 0.1-1.0 and 20 ng/L for the determination of acidic drugs and caffeine, respectively in such samples as surface water, effluent from municipal wastewater plants, as well as receiving waters.  相似文献   

4.
Endosufan, alpha and beta, and three conversion products, sulphate, ether and lactone, were simultaneously determined in human serum by means of an analytical procedure which combines extraction with organic solvents, clean-up with H(2)SO(4) and by liquid column chromatography, and detection by gas chromatography (GC) using electron capture detection (ECD) and tandem mass spectrometry (MS/MS). The procedure was validated and the values of some merit figures, such as linear range, detection and quantitation limits, accuracy, precision and recovery, obtained with the GC/ECD and the GC/MS/MS methods, were compared. The lower limits of detection in GC/ECD and GC/MS/MS were 0.03 and 0.05 microg I(-1), respectively. The recovery of the pesticides at the 20 microg I(-1) concentration level was 60-65%, with the exception of endosufan alpha. Recovery studies at higher levels (100 and 200 microg I(-1)) were independent of pesticide concentration in serum samples. The application of the proposed analytical methodology to the determination of endosulfans and their metabolites in real samples was tested by analyzing serum samples from a population living in agricultural areas of Almeria (Spain). The results show the advantage of MS/MS over the ECD detector in the analysis of serum samples where matrix interferences can be confused with target pesticides.  相似文献   

5.
Summary An analytical procedure for the individual determination of ortho and non-ortho PCB congeners in sediments, using high performance liquid chromatography (HPLC) preseparation and gas chromatography/ECD detection, is described. Gas chromatography/FTIR spectrometry (GC/FTIR) and gas chromatography/mass spectrometry (GC/MS) were employed for individual congener identification and determination. Sample extraction, clean-up of extract and selective elution procedures were optimized by using reference certified marine sediment samples. Recovery and precision were typically 83% and 16% respectively at 2 ng/g of total PCB content. The proposed procedure, tested by analyzing real sediment samples, showed a reproducibility better than 20% at 13 ng/g PCB level.  相似文献   

6.
The three most toxic coplanar PCB 77, 126 and 169 have been identified and quantified at ultra trace levels (0.02-4.8 ng/gdw) in swiss sewage sludge samples applying high resolution capillary gas chromatography (HRGC) and electron impact (EI) as well as negative ion chemical ionization (NCI) mass spectrometry (MS). NCI mass spectra have been dominated by the molecular ion as base peak and virtually no fragmentation has been observed. Detection limits of the planar PCB under single ion monitoring (SIM) conditions have been typically 100 fg for NCI-MS and 1 pg for EI-MS. NCI-MS was the preferred detection method for the determination of very low concentrations of these important contaminants in sewage sludge samples.  相似文献   

7.
Gas chromatography (GC) and ion trap mass spectrometry (MS) were combined with microchip atmospheric pressure chemical ionization (microAPCI) and microchip atmospheric pressure photoionization (microAPPI) sources. Selected polychlorinated biphenyls (PCBs, IUPAC Nos. 28, 52, 101, 118, 138, 153 and 180) were analyzed by GC/microAPCI-MS and GC/microAPPI-MS to demonstrate the applicability of the miniaturized ion sources in negative ion mode analysis. The microAPCI and microAPPI methods were evaluated in respect of detection limit, linearity and repeatability. The detection limits for the PCB congeners were somewhat lower with microAPCI than with microAPPI, whereas microAPPI showed slightly wider linear range and better repeatability. With both methods, the best results were obtained for highly chlorinated or non-ortho-chlorinated PCBs, which possess the highest electron affinities. Finally, the suitability of the GC/microAPPI-MS method for the analysis of PCBs in environmental samples was demonstrated by analyzing soil extracts, and by comparing the results with those obtained by gas chromatography with electron capture detection (GC/ECD).  相似文献   

8.
The three most toxic coplanar PCB 77, 126 and 169 have been identified and quantified at ultra trace levels (0.02–4.8 ng/gdw) in swiss sewage sludge samples applying high resolution capillary gas chromatography (HRGC) and electron impact (EI) as well as negative ion chemical ionization (NCI) mass spectrometry (MS). NCI mass spectra have been dominated by the molecular ion as base peak and virtually no fragmentation has been observed. Detection limits of the planar PCB under single ion monitoring (SIM) conditions have been typically 100 fg for NCI-MS and 1 pg for EI-MS. NCI-MS was the preferred detection method for the determination of very low concentrations of these important contaminants in sewage sludge samples.  相似文献   

9.
A new analytical method using QuEChERS procedure by gas chromatography with a nitrogen-phosphorus detector (GC-NPD) and ion trap mass spectrometry (GC-IT-MS) for the quantitative determination of tebuconazole, trifloxystrobin and its metabolite trifloxystrobin acid has been developed and validated. The analytes were extracted from five fruit and vegetable matrices using acetonitrile and subsequently cleaned up using primary secondary amine (PSA) or octadecylsilane (C18) as sorbent prior to GC analysis. The present methods provided sufficient sensitivity as reflected by the values of limit of detection (LOD) and limit of quantification (LOQ) of 0.4-7 and 1.2-20 μg/kg for GC-IT-MS/MS and GC-NPD. The recoveries were, on average, 68-117 and 68-121%, respectively, for three compounds by GC-NPD and GC-IT-MS/MS with intra-day precision achieved with an RSD of 2.7-19.1%. The inter-day precision was better than 15.1% as determined by GC-NPD. The QuEChERS procedure, by using two sorbents (PSA and C18) and the matrix-matched standards, gave satisfactory recoveries and RSD values in different matrices. IT-MS acquisition provided higher specificity and selectivity for pesticides and better limit of detection and quantification. However, the repeatability and precision of NPD method were better compared with IT-MS.  相似文献   

10.
This paper discusses the applicability of coupling liquid chromatography (LC) to mass spectrometry (MS) using a time-of-flight (TOF) mass analyzer for the analysis of heterocyclic amines (HAs). Accurate mass measurement (<2 mDa) with both MS-MS and in-source CID MS-MS was carried out to confirm the elemental composition of some fragments previously reported. Some isobaric assignments (fragments containing N versus CH2 and NH3 versus CD2H) were distinguished by taking advantage of the resolution provided by the TOF mass analyzer. On the other hand, the LC-MS analysis of HAs in MS acquisition mode was also performed. Quality parameters of the method were established. The linearity range extended over three orders of magnitude, limits of detection were in the pg level and good short-term precision values (R.S.D., 1.2-8.0%) were obtained. The LC-ESI-TOF method was applied to the determination of HAs in a lyophilized meat extract and the results obtained were comparable to those given by MS-MS with triple quadrupole and ion trap instruments.  相似文献   

11.
采用稳定同位素标记的多氯萘(PCNs)同类物为内标,建立了同位素稀释气相色谱/三重四极杆串联质谱技术测定环境样品中20种高关注的PCNs同类物的方法。结果表明:PCNs同类物的校正曲线在0.5~200 μg/L范围内线性良好(R2>0.99),检出限(LOD)为0.04~0.48 μg/L,相对标准偏差(RSD)小于15%。采用基质加标法评价该方法对实际环境样品中PCNs测定的回收率为45.2%~87.9%。为验证方法的适用性,以河流沉积物和再生铝冶炼排放的烟道气样品为对象,利用所建立的方法测定了20种PCNs同类物,并将结果与高分辨气相色谱/高分辨质谱方法的测定结果进行了比对,两种方法测定结果的RSD为0.5%~41.4%,表明所建立的同位素稀释气相色谱/三重四极杆串联质谱方法可用于实际环境样品中PCNs的定性、定量分析。  相似文献   

12.
Inductively coupled plasma-mass spectrometry (ICP-MS) was coupled to a gas chromatographic (GC) system with electron capture detector (ECD), which enables relatively easy characterization and quantification of brominated and iodinated (halogenated) volatile organic compounds (HVOCs) in aquatic and air samples. The GC-ECD system is connected in series with an ICP-MS by a directly heated transfer line and an outlet port-hole for elimination of the ECD make-up gas during ignition of the plasma. The hyphenated GC-ECD/ICP-MS system provides high selectivity and sensitivity for monitoring individual HVOCs under fast chromatographic conditions. The ECD is most sensitive for the detection of chlorinated and brominated but the ICP-MS for iodinated compounds. The greatest advantage of the use of an ICP-MS is its element-specific detection, which allows clear identification of compounds in most cases. The absolute detection limits for ICP-MS are 0.5 pg for iodinated, 10 pg for brominated, and 50 pg for chlorinated HVOCs with the additional advantage that calibration is almost independent on different compounds of the same halogen. In contrast to that detection limits for ECD vary for the different halogenated compounds and lie in the range of 0.03-11 pg. The two-dimensional GC-ECD/ICP-MS instrumentation is compared with electron impact mass spectrometry (EI-MS) and microwave induced plasma atomic emission detection (MIP-AED). Even if EI-MS has additional power in identifying unknown peaks by its scan mode, the detection limits are much higher compared with GC-ECD/ICP-MS, whereas the selective ion monitoring mode (SIM) reaches similar detection limits. The MIP-AED detection limits are at the same level as EI-MS in the scan mode.  相似文献   

13.
Gas chromatography with electron capture detector (ECD), nitrogen-phosphorus detector (NPD), and tandem mass spectrometry (MS/MS) was used to identify 36 pesticides, widely used to control various pest and diseases in vegetables, in water after a preconcentration step on C18 cartridges. The recoveries obtained ranged from 70 to 135% at a fortification level of 100 ng/L with relative standard deviations of <36.2%. The limits of detection and quantitation were < or =48 and < or =160 ng/L, respectively. Important advantages of MS/MS over ECD and NPD in the determination of pesticides are also presented. The proposed analytical methodology was applied to the determination of pesticides in groundwater samples from an agricultural area, the Campo de Dalías (Almería, Spain). The most frequently encountered pesticides were endosulfan sulfate and metalaxyl, whereas the pesticide found at the highest concentration was fenamiphos.  相似文献   

14.
The quantitative and confirmative performance of two different mass spectrometry (MS) techniques (high-resolution MS and tandem MS) was critically compared. Evaluated was a new extraction and clean-up protocol which was developed to cover more than 100 different veterinary drugs at trace levels in a number of animal tissues and honey matrices. Both detection techniques, high-resolution mass spectrometry (HRMS) (single-stage Orbitrap instrument operated at 50 000 full width at half maximum) and tandem mass spectrometry (MS/MS) (quadrupole technology) were used to validate the method according to the EU Commission Decision 2002/657/EEC. Equal or even a slightly better quantitative performance was observed for the HRMS-based approach. Sensitivity is higher for unit mass resolution MS/MS if only a subset of the 100 compounds has to be monitored. Confirmation of suspected positive findings can be done by evaluating the intensity ratio between different MS/MS transitions, or by accurate mass based product ion traces (no precursor selection applied). MS/MS relies on compound-specific optimized transitions; hence the second, confirmatory transition generally shows relatively high ion abundance (fragmentation efficacy). This is often not the case in single-stage HRMS, since a generic (not compound-optimized) collision energy is applied. Hence, confirmation of analytes present at low levels is superior when performed by MS/MS. Slightly better precision, but poorer accuracy (fortified matrix extracts versus pure standard solution) of ion ratios were observed when comparing data obtained by HRMS versus MS/MS.  相似文献   

15.
The performance of gas chromatography coupled with tandem mass spectrometry (GC/MS/MS) was tested for the simultaneous determination of twelve pyrethroid insecticides. First, a comparison of two different ionization modes, electron ionization (EI) and negative chemical ionization (NCI), was carried out using MS and MS/MS. NCI-MS/MS provided the best results in terms of selectivity and sensitivity giving very low detection limits of 0.11 to 450 fg injected. The reliability of the method was confirmed through the evaluation of quality parameters such as accuracy (70-100%), and repeatability and reproducibility, with coefficients of variation below 15% and 10%, respectively. The applicability of the GC/MS/MS method to real samples and influence of matrix effects were evaluated through the analysis of spiked water, sediment and milk at 0.25 ng L(-1) , 5 ng g(-1) dry weight (dw) and 25 ng g(-1) (dw), respectively, of each pyrethroid insecticide considered. Using GC/NCI-MS/MS, matrix spectral interferences were minimized providing method limits of detection (MLODs) of 0.05-2.59 ng L(-1) , 0.10-87.7 pg g(-1) dw, 2.29-1071 pg g(-1) lipid weight (lw) for water, sediment and milk, respectively. To the best of our knowledge, the MLOD values found in our study were better than those reported in previous studies; in particular for sediment and food samples, they were one order of magnitude lower.  相似文献   

16.
A method has been developed and optimised for the determination of two natural estrogens, estrone (E1) and 17beta-estradiol (E2), and one synthetic estrogen, 17alpha-ethynylestradiol (EE2), in river sediments at the sub-ng/g level. This procedure includes microwave-assisted solvent extraction (MASE), solid-phase extraction and high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionisation. Using sediments spiked with the three estrogens at 10 ng/g wet weight, efficient extraction (>92%) of all the three analytes was achieved by MASE, and whole-procedure recoveries ranged from 82 to 98%. Optimisation of the LC separation allowed for substantial reduction of ionisation suppression in the electrospray source to a final level of <18% suppression. Time-of-flight mass spectrometry (TOF-MS) and MS/MS were compared for the analysis of sediment extracts, with the latter technique proving to be the most selective. The method detection limits achieved by LC-MS/MS were 15, 30 and 40 pg/g for E1, E2 and EE2, respectively, which were 13-fold lower than those obtained by LC-TOF-MS. Analysis of river sediments collected from the River Ouse, UK, showed the presence of the natural estrogens at sub-ng/g level. E1 levels ranged from 0.40 ng/g (dry weight) to 3.30 ng/g while E2 levels ranged from <0.03 to 1.20 ng/g and EE2 was never detected (<0.04 ng/g).  相似文献   

17.
Ion chromatography in combination with atmospheric pressure ionization mass spectrometry (API-MS) as well as with inductively coupled plasma mass spectrometry (ICP-MS) had been compared for trace analysis of bromate. The results indicate that both techniques yield comparable results, which are in excellent agreement with standard methods for bromate determination. Furthermore, both techniques showed almost equal absolute detection limits (approximately 50 pg bromate injected). Contrary to IC-API-MS, IC-ICP-MS can tolerate a higher salt concentration in the mobile phase. This allows the use of high-capacity columns combined with large sample volumes. This lowered the concentration based detection limits by one order of magnitude for IC-ICP-MS compared to IC-API-MS (0.06 microg/l vs. 0.5 microg/l). On the other hand, IC-API-MS is able to allow a positive identification of bromate even in cases when IC does not fully separate bromate from other bromine-containing species. The performance data of both IC-MS techniques have been established by participation in an international round robin test.  相似文献   

18.
Inductively coupled plasma mass spectrometry (ICP/MS) is utilized as a detector for several organotin species separated by high-performance liquid chromatography. Detection limits obtained by ICP/MS are 3 orders of magnitude lower than those obtained with inductively coupled plasma atomic emission spectrometry (ICP/AES) detection under the same chromatographic conditions. Chromatographic detection limits are higher than conventional solution nebulization for the same compound by a factor of 20. Ion-exchange chromatography yields linear response over 3 orders of magnitude, while ion pair chromatography gives a linear response of only 2 orders of magnitude as a result of poor resolution. The relative standard deviation for the injection of 20 ng of tin compounds is less than 10%.  相似文献   

19.
对比研究了气相色谱-串联质谱(GC-MS/MS)与气相色谱-四极杆-飞行时间质谱(GC-QTOF/MS)在水果、蔬菜中208种农药多残留检测中基质效应及方法学效能的差异,提出两种仪器在农药残留检测方面的特点和适用范围,为残留检测分析提供参考。在苹果、柑橘、番茄、黄瓜4种基质,3个添加浓度(5.0、10.0和20.0 μg/kg)下,两种仪器中均有93.0%以上的农药回收率在70%~120%范围内且相对标准偏差(RSD)≤20%(n=5)。检测灵敏度方面,绝大部分农药在两种仪器的检出限均低于5.0 μg/kg,满足各国农药残留限量的要求,且GC-MS/MS灵敏度更高,线性范围更宽,定量能力更加准确。筛查确证方面,GC-QTOF/MS在快速、高通量筛查、准确定性及非目标化合物鉴定等方面表现出了优势。  相似文献   

20.
Polybrominated diphenyl ethers (PBDEs) are a class of flame retardants used globally in many consumer products and industrial applications. Traditionally, gas chromatography–high resolution mass spectrometry (GC–HR-MS) is the method of choice for analysis of PBDEs in environmental samples because it offers high sensitivity and selectivity, resulting in less interferences. However, the specificity offered by gas chromatography-triple quadrupole tandem mass spectrometry (GC–QQQ-MS/MS), operated in selected reaction monitoring mode, provides a more affordable alternative to GC–HR-MS for the analysis of PBDEs in complex environmental samples. In this study, an analytical method was developed for the analysis of 41 PBDE congeners in fish using GC–QQQ-MS/MS. Results from the analysis of three fish species [lake trout (Salvelinus namaycush), yellow perch (Perca flavescens), and round goby (Neogobius melanostomus)] using GC–QQQ-MS/MS were compared with those obtained by GC–HR-MS. These species were selected because they represent varying levels of lipid-rich matrix and contaminant loads. Instrumental limits of detection for the GC–QQQ-MS/MS ranged from 0.04 pg to 41 pg, whereas those for the GC–HR-MS ranged from 5 pg to 85 pg. The PBDE values obtained from these two methods were highly correlated, R2 values >0.7, for all three fish species, supporting the suitability of GC–QQQ-MS/MS for analysis of PBDEs in fish with varying fat content.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号