首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The doubly labeled water method provides an objective and accurate measure of total energy expenditure in free‐living subjects and is considered the gold‐standard method for this measurement. Its use, however, is limited by the need to employ isotope ratio mass spectrometry (IRMS) to obtain the high‐precision isotopic abundance analyses needed to optimize the dose of expensive 18O‐labeled water. Recently, cavity‐ring down spectroscopy (CRDS) instruments have become commercially available and may serve as a less expensive alternative to IRMS. We compared the precision and accuracy of CRDS with those of IRMS for the measurement of total energy expenditure from urine specimens in 14 human subjects. The relative accuracy and precision (SD) for total body water was 0.5 ± 1% and for total energy expenditure was 0.5 ± 6%. The CRDS instrument displayed a memory between successive specimens of 5% for 18O and 9% for 2H. The memory necessitated carefully ordering of specimens to reduce isotopic disparity, performance of several injections of each specimen to condition the analyzer, and use of a mathematical memory correction on subsequent injections. These limited the specimen throughput to about one urine specimen per hour. CRDS provided accuracy and precision for isotope abundance measurements of urine that were comparable with those of IRMS. The memory problems were easily recognized by our experienced laboratory staff, but future efforts should be aimed at reducing the memory of the CRDS so that it would be less likely to result in poor reproducibility in laboratories using doubly labeled water for the first time. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
In doubly labelled water studies, biological sample enrichments are mainly measured using off-line techniques (equilibration followed by dual-inlet introduction) or high-temperature elemental analysis (HT-EA), coupled with an isotope-ratio mass spectrometer (IRMS). Here another continuous-flow method, (CF-EA/IRMS), initially dedicated to water, is tested for plasma and urine analyses.The elemental analyser configuration is adapted for each stable isotope: chromium tube for deuterium reduction and glassy carbon reactor for 18O pyrolysis. Before on-line conversion of water into gas, each matrix is submitted to a short and easy treatment, which is the same for the analysis of the two isotopes. Plasma is passed through centrifugal filters. Urine is cleaned with black carbon and filtered (0.45 microm diameter).Tested between 150 and 300 ppm in these fluids, the D/H ratio response is linear with good repeatability (SD<0.2 ppm) and reproducibility (SD<0.5 ppm). For 18O/16O ratios (from 2000 to 2200 ppm), the same repeatability is obtained with a between-day precision lower than 1.4 ppm. The accuracy on biological samples is validated by comparison to classical dual-inlet methods: 18O analyses give more accurate results. The data show that enriched physiological fluids can be successfully analysed in CF-EA/IRMS.  相似文献   

3.
The doubly labelled water method is valuable for measuring energy expenditure in humans. It usually involves blood or urine sampling, which might be difficult in neonates and children with cerebral palsy or other disabilities. We therefore aimed to validate a method making use of saliva samples analyzed by automated thermal conversion elemental analyzer in combination with isotope ratio mass spectrometry (TC‐EA/IRMS). The subjects received labelled water orally and urine and saliva samples were collected and analyzed. Deuterium as well as oxygen18 was measured in one single run using a peak jump method. Excellent linearity was found for measurement of enrichments of deuterium (R2 = 0.9999) and oxygen18 (R2 = 0.9999). The intra‐assay precision and the inter‐assay precision of the measurement of two standards were good for both deuterium and oxygen18. The variation between urine and saliva samples was small (4.83% for deuterium and 2.33% for oxygen18 n = 40). Saliva sampling is to be preferred, therefore, as it can be easily collected and is non‐invasive. Moreover, its time of production is almost exactly known. The TC‐EA/IRMS method is a good alternative to the more laborious off‐line IRMS measurements. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Su CJ  Srimurugan S  Chen C  Shu HC 《Analytical sciences》2011,27(11):1107-1113
Novel sol-gel titania film coated needles for solid-phase dynamic extraction (SPDE)-GC/MS analysis of desomorphine and desocodeine are described. The high thermal stability of titania film permits efficient extraction and analysis of poorly volatile opiate drugs. The influences of sol-gel reaction time, coating layer, extraction and desorption time and temperature on the SPDE needle performance were investigated. The deuterium labeled internal standard was introduced either during the extraction of analyte or directly injected to GC after the extraction process. The latter method was shown to be more sensitive for the analysis of water and urine samples containing opiate drugs. The proposed conditions provided a wide linear range (from 5-5000 ppb), and satisfactory linearity, with R(2) values from 0.9958 to 0.9999, and prominent sensitivity, LOQs (1.0-5.0 ng/g). The sol-gel titania film coated needle with SPDE-GC/MS will be a promising technique for desomorphine and desocodeine analysis in urine.  相似文献   

5.
The theory of pH-stat chelatometric titrations recently developed [Anal. Chim. Acta 456 (2002) 313] is experimentally substantiated here. The titrations of four representative doubly charged cations having different behaviour (copper, zinc, calcium, magnesium) are taken as examples. Copper is titratable between pH 3 and 5, zinc between 3 and 6, calcium between 6 and 10, and magnesium between 7 and 10. The shapes of the titration plots agree well with the theory, accounting for simultaneous equilibria involving proton exchange. The technique yields accurate and precise results, which compare favourably with those of other instrumental techniques, in particular photometric titrations.  相似文献   

6.
Nucleophilic mixed chromium(II) and chromium(III) acetylides are generated from the smooth reduction of primary 1,1,1-trichloroalkanes with chromium(II) chloride in the presence of an excess amount of triethylamine at room temperature. These species arise from chromium(III) vinylidene carbenoids. It has been demonstrated that uncommon low-valent Cr(II) acetylides are formed by C-H insertion of Cr(II)Cl(2) into terminal alkynes, formed in situ through the Fritsch- Buttenberg-Wiechell (FBW) rearrangement, whereas Cr(III) acetylides are concomitantly generated by HCl elimination from the chromium(III) vinylidene carbenoid. Both divergent pathways result, overall, in the formation of nucleophilic acetylides. In situ trapping with electrophilic aldehydes afforded propargyl alcohols. Furthermore, deuteration experiments and the use of deuterium labeled 1,1,1-trichloroalkane substrates demonstrated the prevalence of low-valent Cr(II) acetylides, potentially useful, yet highly elusive synthetic intermediates.  相似文献   

7.
An off-line technique is described for the preparation of H(2) from water prior to analysis of delta(2)H by dual-inlet isotope ratio mass spectrometry. H(2) is produced from sample water by reaction with LiAlH(4). This provides a rapid and inexpensive method for the analysis of delta(2)H in small (10 microL) samples of water. Precision was +/- 4.2 to 8.0 (1sigma(n), n = 8) delta(2)H(VSMOW) for samples between 428 and 1500 delta(2)H(VSMOW), +/- 14.5 delta(2)H(VSMOW) for water enriched to 3750 delta(2)H(VSMOW) and +/- 26.0 delta(2)H(VSMOW) for water enriched to 6100 delta(2)H(VSMOW). Accuracy was +/- 1.1 to 4.2 delta(2)H(VSMOW) for water standards from natural abundance to 1000 delta(2)H(VSMOW) (the highest enrichment at which water of accepted delta(2)H is currently available). This method for delta(2)H determination is most appropriate for use with small (<50 microL) samples of high delta(2)H enrichment such as those produced from doubly labelled water studies of small animals. The levels of measurement precision of delta(2)H would contribute 2.6-3.8% to the precision error in estimates of small animal energy expenditure made using the doubly labelled water technique when duplicate analyses are performed.  相似文献   

8.
建立了碱消解-火焰原子吸收光谱法测定土壤中六价铬的方法.讨论了pH值对六价铬测定的影响.干扰实验的结果表明同等含量的三价铬对六价铬测定无干扰.实验对比了无背景校正、氘灯背景校正、塞曼背景校正三种工作方式,分别对低、中、高三个水平土壤六价铬标准物质进行了测定,结果表明,低含量的土壤样品用塞曼背景校正方式测定的结果更准确,...  相似文献   

9.
A simple and sensitive method has been developed for species selective determination of chromium(III) and chromium(VI) in water by electrothermal atomic absorption spectrometry. The procedure is based on selective absorption of Cr(III) on a cellulose micro column (pH 11, 0.5 mol L(-1) NaCl). Total chromium was subsequently determined after appropriate reduction of Cr(VI) to Cr(III). Recoveries of more than 97% were found. A concentration factor of 100 was achieved. The relative standard deviations (n=10) at the 40 ng L(-1) level for chromium(III) and chromium(VI) were 2.3% and 1.8% and corresponding limits of detection (based on 36) were 1.8 ng L(-1) and 5.1 ng L(-1), respectively. No interference effects have been observed from other investigated species and the method has been successfully applied to natural water samples.  相似文献   

10.
A gas chromatographic-mass spectrometric (GC-MS) method involving thermally stable, volatile chelates was investigated for measurements of isotope ratios of chromium, nickel, zinc and copper. The chelating agents acetylacetone, trifluoroacetylacetone, sodium diethyldithiocarbamate and lithium bis (trifluoroethyl)dithiocarbamate [Li(FDEDTC])] were used. Experimental conditions for the preparation of chelates and the mass spectrometric operating parameters for precise and accurate measurement of isotope ratios were optimized using a general-purpose mass spectrometer. Imprecision values of 1–4% were obtained for measurements of different isotope ratios using chelates containing about 10 ng of metal. The capability of this technique for the accurate determination of natural and altered isotope ratios was also evaluated for these elements using Li(FDEDTC) as a chelating agent. This GC-MS method obviates the need for a more specialized mass spectrometer such as a thermal ionization or inductively coupled plasma mass spectrometer for trace metal determination. The technique gives detection limits down to parts per 109 levels and offers considerable potential for isotope dilution measurements.  相似文献   

11.
A new radiochemical group separation method using APDC reagent in the extraction procedure has been developed. The method has been applied to the radiochemical separation for activated biological samples and also to the preconcentration technique for sea water samples. The transition elements are extracted into chloroform phase from the pH 3.0 aqueous phase and only manganese is subsequently extracted from the pH 7.0 aqueous phase. The validity of the method is demonstrated by analyzing the NBS standard reference materials. In the specimens preconcentrated from the sea water samples adjusted pH to 5.5, vanadium, manganese, copper and zinc can be determined.  相似文献   

12.
研究了在含钻铬锰永磁合金中,在酸性环境及加热条件下,以过硫酸铵将锰氧化成MnO_2·xH_2O而沉淀分离。滤液经掩蔽其它元素后,加过量乙二胺四乙酸二钠盐标准溶液,以氯化锌标准溶液返滴定测定钴。铬及锰以氧化还原法连续测定。方法准确度高,精密度好,回收率大于99.6%,结果满意。  相似文献   

13.
Pteridines and their derivatives are important cofactors in the process of cell metabolism, and the level of urinary excretion of these compounds is considered as an important clinical criterion. In this work, a new separation method involving hydrophilic interaction chromatography (HILIC) with tandem mass spectrometric detection has been developed for the simultaneous analysis of 12 pteridines including oxidized, di‐ and tetrahydroforms, namely neopterin, 7,8‐dihydroneopterin, biopterin, 7,8‐dihydrobiopterin, 5,6,7,8‐tetrahydrobiopterin, dimethylpterin, dimethyltetrahydropterin, pterin, isoxanthopterin, xanthopterin, sepiapterin and pterin‐6‐carboxylic acid, in human urine without oxidative pretreatments. The stabilizing agent (dithiothreitol) at various concentrations and the stability of oxidized, di‐ and tetrahydroforms during the sample's short‐term storage and processing and of the extracts were tested. In the developed method, 12 pteridines were chromatographically separated on an ZIC‐HILIC column by gradient elution, and the run time was 20 min. Matrix effect was evaluated and several dilutions of urine were tested in order to study the evolution of signal suppression. Spiked recovery studies demonstrated that the technique was both accurate (83.1–116.7%) and precise (RSD 1.4–15.6%). Finally, several clinical urine specimens without oxidative pretreatments were examined with the new technique and compared with previous reports.  相似文献   

14.
A rapid and accurate gas chromatographic (GC) method is described for the determination of chloramphenicol, thiamphenicol and their metabolites excreted in human urine. These excretions were pre-treated with diazomethane and N,O-bis(trimethylsilyl)acetamide, so that they could be easily subjected to GC with satisfactory separation from each other and also from other urinary excretions, and could be determined simultaneously. The structures of the metabolites were confirmed by GC combined with mass spectrometric measurements of the GC peaks. The application of the method to urine specimens enabled more precise results for the amounts of metabolites present to be obtained; the excretion of thiamphenicol glucuronide was not observed.  相似文献   

15.
A method for the determination of chromium species has been developed and successfully applied to both fresh and sea water samples. The method utilizes pre-concentration of total chromium, chromium(ni) and particulate chromium at natural pH with accurate and precise analysis by a single flameless atomic absorption procedure. A minimal blank allows for a reliable detection limit of 0.02 nM, which is sufficient for most natural waters with chromium concentrations in the range 0.01–10 nM. Immediate shipboard preconcentration of the samples minimizes storage problems. The method is simple and rapid; 20 samples can be analysed in duplicate for total chromium, chromium(III) and particulate chromium in one day with routinely available reagents and equipment.  相似文献   

16.
A liquid chromatographic-electrospray ionization-tandem mass spectrometric method for the quantification of the opiates morphine, codeine, and their metabolites morphine-3-beta-D-glucuronide (M-3-G), morphine-6-beta-D-glucuronide (M-6-G) and codeine-6-beta-D-glucuronide (C-6-G) in human urine has been developed and validated. Identification and quantification were based on the following transitions: 286 to 201 and 229 for morphine, 300 to 215 and 243 for codeine, 462 to 286 [corrected] for M-3-G, 462 to 286 for M-6-G, and 476 to 300 for C-6-G. Calibration by linear regression analysis utilized deuterated internal standards and a weighting factor of 1/X. The method was accurate and precise across a linear dynamic range of 25.0 to 4000.0 ng/ml. Pretreatment of urine specimens using solid phase extraction was sufficient to limit matrix suppression to less than 40% for all five analytes. The method proved to be suitable for the quantification of morphine, codeine, and their metabolites in urine specimens collected from opioid-dependent participants enrolled in a methadone maintenance program.  相似文献   

17.
We have developed a simple and convenient method for the determination of Cr(III), Cr(VI), and the total chromium concentrations in natural water and urine samples that use a flow injection on-line desalter-inductively coupled plasma-mass spectrometry system. When using aqueous ammonium chloride (pH 8) as the stripping solution, the severe interference from sodium in the matrix can be eliminated prior to inductively coupled plasma-mass spectrometry measurement, and the Cr(VI) level can be determined directly. To determine the total concentration of Cr in natural water and urine samples, we used H2O2 or HNO3 to decompose the organic matter and convert all chromium species into the Cr(VI) oxidation state. To overcome the spectral interference caused by the matrix chloride ion in the resulting solutions, we employed cool plasma to successfully suppress chloride-based molecular ion interference during the inductively coupled plasma-mass spectrometry measurement. By significantly eliminating interference from the cationic and anionic components in the matrices prior to the inductively coupled plasma-mass spectrometry measurement, we found that the detection limit reached 0.18 μg L 1 (based on 3 sigma). We validated this method through the analysis of the total chromium content in two reference materials (NIST 1643c and 2670E) and through measuring the recovery in spiked samples.  相似文献   

18.
A method is described for the determination of cobalt in beryllium or beryllium oxide by extraction of the cobalt thiocyanate complex with acetylacetone (2:4-pentanedione). The method is accurate to ±2% or 2 μg of cobalt, whichever is greater. Of the 68 elements investigated only manganese and chromium interfere in 10 mg amounts. No interference was observed when 1g of each had been removed by ion-exchange or volatilisation (of chromium only) before extraction.  相似文献   

19.
Aldimines react with reducing agents, such as Grignards, phenylsilane or zinc in the presence of titanium(IV) isopropoxide to form amines and reductively coupled imines (diamines). Using deuterium labeled reagents, the mechanism of reduction to form amines is described. Reducing agents, such as the Grignard and zinc result in the formation of low valent titanium (LVT), which in turn reduces the imine. On the other hand, phenylsilane reacts by a distinctly different mechanism and where a hydrogen atom from silicon is directly transferred to the titanium coordinated imine.  相似文献   

20.
Acid digestion procedures are described for the dissolution of human head hair in routine determinations of cadmium, chromium, mercury, lead and zinc in the same sample solution by means of atomic absorption spectrometry. The techniques employed are atomization in a Massman graphite furnace or in an air—acetylene flame; the cold-vapor cell is used for mercury. The entire analytical procedure is tested with powdered homogenized head hair samples, previously analyzed by other analytical techniques. Comparison of the results demonstrates that the proposed technique is at least as precise and accurate as the other procedures used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号