首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, rapid and reproducible capillary isotachophoretic on-line coupled with capillary zone electrophoresis (CITP-CZE) method for the determination of IMz in food packaging extracts and its residues in apples is described. A good separation of the IMZ from other sample constituents was achieved within 15 minutes without any sample clean up. Method characteristics (linearity, accuracy, intra-assay and detection limit) were determined. Less amount of time involved, sufficient sensitivity and low running cost are the important attributes of CITP-CZE method.  相似文献   

2.
Limited by the lack of a sensitive, universal detector, many capillary-based liquid-phase separation techniques might benefit from techniques that overcome modest concentration sensitivity by preconcentrating large injection volumes. The work presented employs selective solid-phase extraction by immunoaffinity capillary electrochromatography (IACEC) to enhance detection limits. A model analyte, fluorescein isothiocyanate (FITC) biotin, is electrokinetically applied to a capillary column packed with an immobilized anti-biotin-IgG support. After selective extraction by the immunoaffinity capillary, the bound analyte is eluted, migrates by capillary zone electrophoresis (CZE), and is detected by laser-induced fluorescence. The column is regenerated and reused many times. We evaluate the performance of IACEC for selective trace enrichment of analytes prior to CZE. The calibration curve for FITC-biotin bound versus application time is linear from 10 to 300 seconds. Recovery of FITC-biotin spiked into a diluted urinary metabolites solution was 89.4% versus spiked buffer, with a precision of 1.8% relative standard deviation (RSD).  相似文献   

3.
An on-line coupled capillary isotachophoresis--capillary zone electrophoresis (cITP-CZE) method for the determination of domoic acid in shellfish and algae is described. The optimised cITP-CZE electrolyte system was 10 mM HCl + 20 mM beta-alanine (BALA) + 0.05% hydroxyethylcellulose (leading electrolyte), 5 mM caproic acid (terminating electrolyte) and 20 mM caproic acid + 20 mM BALA + 0.1% HPMC (background electrolyte). A clear separation of the domoic acid from the other components of methanolic sample extract was achieved within 25 min. Method characteristics, i.e., linearity (0-200 microg/l), accuracy (recovery 101+/-3%), intra-assay repeatability (2.4%) and detection limit (1.5 microg/l) were determined. Speed of analysis, low laboriousness, high sensitivity and low running cost are the typical attributes of the cITP-CZE method. Developed method was successfully applied to analysis of shellfish samples and food supplements containing algae extract.  相似文献   

4.
An on-line coupled capillary isotachophoresis-capillary zone electrophoresis method for the determination of glycyrrhizin in liqueurs is described. The optimised electrolyte system was 5 mM HCl+11 mM varepsilon-aminocaproic acid+0.05% hydroxyethylcellulose+30% methanol (leading electrolyte), 5 mM caproic acid+30% methanol (terminating electrolyte) and 20 mM caproic acid+10 mM histidine+0.1% hydroxyethylcellulose+30% methanol (background electrolyte). Method characteristics, i.e., linearity (20-500 ng/ml), accuracy (recovery 99+/-4%), intra-assay repeatability (2%), intermediate repeatability (3.8%) and detection limit (8 ng/ml) were determined. Speed of analysis, low laboriousness, high sensitivity and low-running cost are the typical attributes of the capillary isotachophoresis-capillary zone electrophoresis method. Developed method was successfully applied to analysis of liqueurs with liquorice extract and some foods (sweets and food supplements) containing liquorice. Found levels of glycyrrhizin in liqueurs, sweets and food supplements varied between 1-16 mg/l, 850-1050 mg/kg and 1.6-1.8 g/kg, respectively.  相似文献   

5.
Transient states in the evolution of electrophoretic systems comprising aqueous solutions of weak monovalent acids and bases are simulated. The mathematical model is based on the system of nonstationary partial differential equations, expressing the mass and charge conservation laws while assuming local chemical equilibrium. It was implemented using a high resolution finite-difference algorithm, which correctly predicted the behavior of the concentration, pH and conductivity fields at low computational expense. Both the regular and the irregular modes of separation in capillary zone electrophoresis and isotachophoresis are considered. It is shown that the results of separation, particularly zone order, strongly depend on pH distribution. Simulation data as well as simple analytical assessments may help to predict and correctly interpret the experimental results.  相似文献   

6.
An on-line coupled capillary isotachophoresis - capillary zone electrophoresis method for the determination of lysozyme in selected food products is described. The optimized electrolyte system consisted of 10 mM NH(4)OH + 20 mM acetic acid (leading electrolyte), 5 mM epsilon -aminocaproic acid +5 mM acetic acid (terminating electrolyte), and 20 mM epsilon -aminocaproic acid +5 mM acetic acid +0.1% m/v hydroxypropylmethylcellulose (background electrolyte). A clear separation of lysozyme from other components of acidic sample extract was achieved within 15 min. Method characteristics, i.e., linearity (0-50 micrograms/mL), accuracy (recovery 96+/-5%), intra-assay (3.8%), quantification limit (1 microgram/ml), and detection limit (0.25 microgram/mL) were determined. Low laboriousness, sufficient sensitivity and low running costs are important attributes of this method. The developed method is suitable for the quantification of the egg content in egg pasta.  相似文献   

7.
Online combination of transient ITP and CZE is employed for the determination of Cd(II), Pb(II), Cu(II), Ni(II), and Zn(II). Acetic acid is used for creating the transient isotachophoretic state. alpha-Hydroxyisobutyric acid and 4-aminopyridine are used as BGEs for the separation and indirect UV detection. At optimum conditions, the method allows to determine the metals at levels of 40-120 microg/L, about 50 times more sensitive than conventional CZE. In combination with a 20-fold evaporative concentration, the method is suitable for environmental monitoring of the heavy metals in snow samples.  相似文献   

8.
A method for determination of nine brominated phenols as environmental risk compounds was developed by on-line coupled capillary isotachophoresis and capillary zone electrophoresis (ITP–CZE). For ITP step, 1 × 10−2 mol L−1 hydrochloric acid with 3 × 10−2 mol L−1 ammediol pH 9.1 was used as the leading electrolyte, and 3 × 10−2 mol L−1 β-alanine with 2 × 10−2 mol L−1 sodium hydroxide pH 10.05 was used as the terminating electrolyte. As the background electrolyte for CZE separation, 2.5 × 10−2 mol L−1 β-alanine with 2.5 × 10−2 mol L−1 lysine pH 9.6 was used. All electrolytes contained 0.05% or 0.1% (m/v) hydroxyethylcellulose to suppress the electroosmotic flow. UV detection at wavelength 220 nm was used. Detection limits in order of tens of nmol L−1 were achieved. Good repeatability of migration times (less than 0.33% RSD) and good repeatability of peak areas (less than 7.19% RSD) at concentration level 5 × 10−8 mol L−1 were observed. Developed ITP–CZE method was applied to determination of brominated phenols in spiked tap and river water samples.  相似文献   

9.
Some oxyhalides can be found in drinking waters as inorganic disinfection byproducts. An on-line coupled capillary isotachophoresis—capillary zone electrophoresis (CITP-CZE) method was developed for the analysis of chlorate, chlorite and bromate in water. The optimized CITP-CZE electrolyte system consisted of the following: 10 mM—HCl+20 mM—β-Alanine (leading electrolyte), 5 mM—succinic acid (terminating electrolyte), and 10 mM—succinic acid +5 mM—β-Alanine +0.1% HPMC (carrier electrolyte). A clear separation of oxyhalides from other components of drinking water was achieved within 25 min. Method characteristics, i.e., linearity (0–200 ng/mL), accuracy (88–110%), intra-assay (3–5%), quantification limit (5–15 ng/mL), and detection limit (2–5 ng/mL), were determined. Minimum labor requirements, sufficient sensitivity and low running cost are important attributes of this method. It was found that the developed method is useful for the routine analysis of oxyhalides in water.  相似文献   

10.
A new approach was described to achieve very sensitive analysis of peptide hormone of brain and intestine by capillary electrophoresis coupled with a transient isotachophoresis (tITP) preconcentration method. The system used was electrospray ionization mass spectrometry (ESI-MS) as detector and equipped with a sheath flow configuration. The effects of sample matrix, pH and concentration of leading electrolyte (LE), sample injection time, and ESI-MS instrumental parameters on the efficiency of the sample stacking were investigated in detail. Under the optimized conditions, lower than micromole (0.01 microM) concentrations of the peptides were easily detected. Compared to traditional hydrodynamic injection methods, about 40-230-fold increase in detection sensitivity was obtained by this technique. A distinguishing feature of the described approach is that the background electrolyte can serve as terminating electrolyte (TE), which simplifies the process of the experiments. The method was further evaluated by the analysis of low concentration active peptide mixtures spiked in hypothalamus tissue of the rat.  相似文献   

11.
Transient isotachophoresis (tITP) can improve the sensitivity of capillary electrophoresis (CE). In general, it was carried out under the condition of suppressed electroosmotic flow (EOF). However, some special conditions, such as extreme low pH background electrolyte and coating were needed to achieve the requirements of suppressed EOF. In this work, an approach of tITP under the strong counter-EOF in open system (counter-EOF-tITP) is presented for the rapid and sensitive preconcentrating the reduced glutathione (GSH) and the oxidized glutathione (GSSG) without modifying the capillary and the commercial CE instrument. The parameters of the experimental system, such as the concentration of leading electrolyte, the injected amount of terminating electrolyte and the injected pressure of sample were investigated in detail to understand the mechanism of counter-EOF-tITP. The sensitivity enhancement factors were of 320 for GSH and 280 for GSSG. In addition, the detection limit of 23.4 and 18.0 μg L−1 for GSH and GSSG was achieved, respectively. The method's applicability was demonstrated by determining GSH and GSSG in tomato and human serum.  相似文献   

12.
Single drop microextraction (SDME) can be in-line coupled with capillary electrophoresis by attaching a drop to the tip of a capillary. With a 2-layer drop comprised of an aqueous basic acceptor phase covered with a thin organic layer, acidic analytes in an aqueous acidic donor phase can be extracted into the organic layer and then back-extracted into the acceptor phase. However, preconcentration of amino acids and peptides by SDME is difficult since their zwitterionic properties prevent them from being partitioned in the middle organic phase. When amino acids were derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F), amino acids without a charged side chain were converted to carboxylic acids. In the acidic donor phase, those NBD-amino acids were predominantly neutral and they were successfully concentrated into the basic acceptor phase. In the meantime, amino acids with a charged side chain after NBD-F derivatization were not concentrated via SDME. With this selective SDME, we were able to extract acidic and neutral amino acids obtaining several hundred-fold enrichments within 5 min at 25 °C, while leaving basic amino acids—Arg, Lys, and His—in the acidic donor phase. Furthermore, detection sensitivity was enhanced by employing laser-induced fluorescence detection. We then applied this technique to the selective concentration of peptides.  相似文献   

13.
《Electrophoresis》2017,38(16):2018-2024
Capillary ITP (CITP) and CZE were applied to the determination of effective charges and ionic mobilities of polycationic antimicrobial peptides (AMPs). Twelve AMPs (deca‐ to hexadecapeptides) containing three to seven basic amino acid residues (His, Lys, Arg) at variable positions of peptide chain were investigated. Effective charges of the AMPs were determined from the lengths of their ITP zones, ionic mobilities, and molar concentrations, and from the same parameters of the reference compounds. Lengths of the ITP zones of AMPs and reference compounds were obtained from their CITP analyses in cationic mode using leading electrolyte (LE) composed of 10 mM NH4OH, 40 mM AcOH (acetic acid), pH 4.1, and terminating electrolyte (TE) containing 40 mM AcOH, pH 3.2. Ionic mobilities of AMPs and singly charged reference compounds (ammediol or arginine) were determined by their CZE analyses in the BGE of the same composition as the LE. The effective charges numbers of AMPs were found to be in the range 1.65–5.04, i.e. significantly reduced as compared to the theoretical charge numbers (2.86–6.99) calculated from the acidity constants of the analyzed AMPs. This reduction of effective charge due to tightly bound acetate counterions (counterion condensation) was in the range 17–47% depending on the number and type of the basic amino acid residues in the AMPs molecules. Ionic mobilities of AMPs achieved values (26.5‐38.6) × 10−9 m2V−1s−1 and in most cases were in a good agreement with the ratio of their effective charges and relative molecular masses.  相似文献   

14.
Platinum adducts are supposed to be the cytotoxic lesions in DNA after platinum-containing anticancer therapy. Various adducts are formed upon interaction of platinum complexes with nucleotides, but contribution of individual adducts to antitumor activity and toxicity of platinum complexes still remains to be examined. A capillary zone electrophoresis (CZE) method is described that is suitable to separate individual platinum adducts. We investigated the formation of adducts following the reaction of cis-diamminedichloroplatinum (II) (cisplatin) with various DNA nucleotides. Baseline separation of unmodified and modified nucleotides (adducts) was achieved using uncoated fused-silica capillaries and basic separation buffers. In order to elucidate the observed peak pattern, a coupled CZE-electrospray ionization-mass spectrometry (ESI)-MS approach was applied. After incubation of mononucleotides with cisplatin, monochloro, monoaqua and bifunctional adduct species were detected. Consequently, the migration order of nucleotides and individual platinum adducts could be determined. Moreover, the time-dependent conversion from monochloro to monoaqua and subsequently to bifunctional adducts was monitored. In conclusion, individual platinum adducts were separated by CZE and identified by CZE-ESI-MS. Formation and conversion of distinct species were confirmed. Potential applications comprise studies of novel platinum complexes, investigations of platinum-adduct formation with DNA, and determination of platinum-DNA adducts in cells.  相似文献   

15.
In this report aimed on further development of a high-sensitivity capillary gel electrophoresis (CGE) method for analysis of DNA fragments, we firstly explored online transient isotachophoresis (tITP) preconcentration combined with fluorescence detection (FD). The fluorescence signal (excitation: 488 nm; emission: 590 nm) was generated using the intercalating dye of ethidium bromide (EB). It was found when the leading electrolyte (LE) was injected behind the sample zone, such a special tITP mode has significant advantages to solve the bubble formation issue and to improve the analytical performance stability. Two standard DNA samples, a 50 bp DNA step ladder and the φX174/HaeIII digest, were used to evaluate the qualitative and quantitative abilities of the tITP-FD approach. A highly diluted sample (10,000-fold in the water, e.g. the φX174/HaeIII digest diluted from 500 μg/ml to the 50 ng/ml level) was enriched and detected; the LOD was down to 0.09 ng/ml for the 72 bp fragment, apparently improved more than 1000-fold in comparison with UV detection. Although the RSD of peak areas (n = 3) was around 15.5% for the sample was electrokinetically injected, good linearity of peak area response showed that the proposed method is suitable for quantitative analysis.  相似文献   

16.
Stutz H  Bordin G  Rodriguez AR 《Electrophoresis》2004,25(7-8):1071-1089
A capillary zone electrophoresis (CZE) method with preceding cationic transient capillary isotachophoresis (tCITP-CZE) was developed for uncoated fused-silica capillaries to analyze metal-binding proteins (MBPs) of clinical relevance. UV detection was followed by mass spectrometry (MS). Optimization was done with model proteins of properties similar to relevant human MBPs. Using 1.0 mol x L(-1) formic acid (pH 1.78) as electrolyte resulted in up to 165000 plates m(-1) in CZE and 230000 plates m(-1) in combination with tCITP and analysis time was less than 5 min in uncoupled mode. Cationic tCITP with 125 mmol x L(-1) ammonium formate, buffered to pH 4.00, as leading electrolyte improved sample loadability considerably in comparison with sample stacking without impairing resolution. Following systematic optimization of the electrospray ionization process (ESI) the coupled system ((tCITP)-CZE-UV-ESI-MS) was tested with protein model mixtures and human MBPs. Repeatability of migration times was < 0.64% in pure CZE mode and in tCITP-CZE mode and < 0.83% in CZE-ESI-MS coupled mode. Mass accuracy was < 0.015%. Limits of detection were found to be in the range 50-160 fmol.  相似文献   

17.
CE is gaining great popularity as a well‐established separation technique for many fields such as pharmaceutical research, clinical application, environmental monitoring, and food analysis, owing to its high resolving power, rapidity, and small amount of samples and reagents required. However, the sensitivity in CE analysis is still considered as being inferior to that in HPLC analysis. Diverse enrichment methods and techniques have been increasingly developed for overcoming this issue. In this review, we summarize the recent advances in enrichment techniques containing off‐line preconcentration (sample preparation) and on‐line concentration (sample stacking) to enhancing sensitivity in CE for trace analysis over the last 5 years. Some relatively new cleanup and preconcentration methods involving the use of dispersive liquid–liquid microextraction, supercritical fluid extraction, matrix solid‐phase dispersion, etc., and the continued use and improvement of conventional SPE, have been comprehensively reviewed and proved effective preconcentration alternatives for liquid, semisolid, and solid samples. As for CE on‐line stacking, we give an overview of field amplication, sweeping, pH regulation, and transient isotachophoresis, and the coupling of multiple modes. Moreover, some limitations and comparisons related to such methods/techniques are also discussed. Finally, the combined use of various enrichment techniques and some significant attempts are proposed to further promote analytical merits in CE.  相似文献   

18.
Praus P 《Talanta》2004,62(5):977-982
An isotachophoresis (ITP)–capillary zone electrophoresis (CZE) combination was used for the determination of chlorite in drinking waters. No sample preparation is needed and no interfering by other anions in tap water was observed. The reached limits of detection with conductivity detector were 0.012–0.017 mg l−1. By four-fold sample loading with a 30 μl valve, 0.005 mg l−1 of chlorite was determined with R.S.D.=3.3%. The concentrations of 0.05 and 0.20 mg l−1 were measured with R.S.D. of 2.2 and 2.7%, respectively. The recoveries of chlorite from drinking water were 96–106% in the range of 0.02–0.20 mg l−1. The R.S.D. values of migration times (inter-day) were up to 1.3%. The time for analysis is about 15 min.  相似文献   

19.
An on-capillary adsorptive phase in combination with capillary electrophoresis (CE), frequently referred to as preconcentration CE, for quantitative analysis of low peptide concentrations was developed. The capillary containing the on-line analyte preconcentrator can be constructed within 5 min from commercially available extraction disks. These disks contain poly(styrenedivinylbenzene) adsorbent particles incorporated in a matrix of inert Teflon, creating a mechanically stable sorbent. Therefore, no frits are needed in the capillary to hold the stationary phase in place. Several parameters, such as the required minimal elution volume, required elution strength, sample application speed or ionic strength, and the capacity were investigated and special interest was given to the quantitative properties of the method. Instead of nL injections, volumes up to a least 25 microL are possible, yielding improvements in detection limits of 3-4 orders of magnitude. The observed limit of detection for both model peptides was 20 pg, corresponding to a 20 microL injection of a 1 ng/mL solution of both model peptides. Using low-wavelength UV detection, reproducibility and linearity in the low nanogram range were satisfactory. No influence of matrix salt concentrations was observed, extending the use of CE to all kinds of samples.  相似文献   

20.
The performance of a biotrickling filter for treatment of concentrated waste gases was investigated. The macrokinetics of methylmethacrylate degradation in the biotrickling filter is studied by measuring the degradation product methacrylic acid in the drain of the filter. The drain was analysed using isotachophoresis (ITP) and capillary zone electrophoresis (CZE). The CZE analyses were carried out in an I.D. 75 microm capillary at 20 kV (negative inlet polarity) using a 0.01 M Tris-acetate buffer of pH 4.45. The electroosmotic flow (EOF) was suppressed by addition of CTA and PVA to the buffer. Detection was at 214 nm. After filtration through a 0.45-microm filter, samples were directly injected. The calibration graph was linear between 10 and 800 mg/l methacrylic acid, with an analysis time under 2 min.  相似文献   