首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Uslu  Bengi  &#;zden  Tugba 《Chromatographia》2013,76(21):1487-1494

High efficiency and less elution are the basic requirements of high-speed chromatographic separation. In this study, a new gradient reverse phase chromatographic methods were developed using HPLC and UPLC systems for simultaneous determination of enalapril maleate (ENL) and hydrochlorothiazide (HCZ) in pharmaceutical dosage forms. The chromatographic separations of ENL and HCZ were achieved on a Waters μ-Bondapak C 18, (300 × 3.9 mm, 10 μm) and Waters Acquity BEH C18 (100 × 2.1 mm, 1.7 μm) columns for HPLC within 5.30 min and UPLC within a short retention time of 1.95 min, respectively. A linear response was observed over the concentration range 0.270–399 μg mL−1 of ENL, 0.260–399 μg mL−1 of HCZ for HPLC system and 0.270–399 μg mL−1 of ENL and 0.065–249 μg mL−1 of HCZ for UPLC system. Also, limit of detection for ENL was 1.848 ng mL−1 and 31.477 ng mL−1 for HCZ, 2.804 ng mL−1 for ENL and 2.943 ng mL−1 for HCZ using HPLC and UPLC, respectively. The proposed methods were validated according to ICH guideline with respect to precision, accuracy, and linearity. Forced degradation studies were also performed for both compounds in bulk drug samples to demonstrate the specificity and stability indicating power of the HPLC method. Comparison of system performance with conventional HPLC was made with respect to analysis time, efficiency, and resolution.

  相似文献   

2.
Aksoy  B.  K&#;&#;&#;kg&#;zel  &#;.  Rollas  S. 《Chromatographia》2007,66(1):57-63

The objective of the current study was the development and subsequent validation of a simple, sensitive, precise and stability-indicating reversed-phase HPLC method for the determination of ciprofloxacin HCl in pharmaceutical dosage forms in the presence of its potential impurities. The chromatographic separation of ciprofloxacin HCl and its related compounds was achieved on an Inertsil ODS3 column using UV detection. The optimized mobile phase consisted of phosphoric acid solution: acetonitril. The proposed method provided linear responses within the concentration range 250–750 μg mL−1 for ciprofloxacin HCl and 0.5–1.5 μg mL−1 for its related compounds. LOD and LOQ values for the active substance were 5.159 and 15.632 μg mL−1, respectively. Correlation coefficients (r) of the regression equations for the impurities were greater than 0.99 in all cases. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 1% in all instances. No interference from any components of pharmaceutical dosage forms or degradation products was observed.

  相似文献   

3.

This paper describes the validation of an isocratic LC method for the assay of linezolid in tablets. Validation parameters such as linearity, precision, accuracy, specificity, limit of detection, limit of quantitation and robustness were determined. LC was carried out by reversed phase technique on an RP-18 column with a mobile phase composed of 1% acetic acid:methanol:acetonitrile (50:25:25, v/v/v). Linezolid and your combination drug product were exposed to acid, base, oxidation, dry heat and photolytic stress conditions. A linear response (r > 0.9999) was observed in the range of 8.0–20.0 μg mL−1. The retention time of linezolid was 4.6 min. The method showed good recoveries and intra- and inter-day relative standard deviations were less than 1.0%. The LOD and LOQ were 0.21 and 0.63 μg mL−1, respectively. The developed LC method for determination of related substances and assay determination of linezolid can be used to evaluate the quality of regular production samples. It can also be used to test the stability samples of linezolid.

  相似文献   

4.

Praziquantel (PZQ) is a highly lipophilic drug with low aqueous solubility. Despite this, it is well absorbed from the gastrointestinal tract. In this study, a simple LC method was developed and validated, in order to monitor the concentration of PZQ in TC-199 buffer in vitro, in the rat everted gut sac absorption model. PZQ was analyzed by a reversed-phase LC method with an isocratic mobile phase containing acetonitrile and water in the proportions 45:55. The flow-rate was 1 mL min−1 and PZQ was determined by measuring absorbance at 215 nm, at 25 °C. The method was found to be specific, as none of the components of TC-199 or intestinal sac artefacts interfered with the drug peak. Recovery was within acceptable statistical limits. The limit of detection was 0.54 μg mL−1 and the limit of quantitation was 1.63 μg mL−1. The calibration curve was found to be linear in the concentration range of 10–90 μg mL−1 PZQ. The proposed method was found to be rapid and selective and hence can be applied in the monitoring of the absorption of PZQ in in vitro everted gut sac absorption studies.

  相似文献   

5.
Fang  Lina  Wang  Qiudi  Bi  Kaishun  Zhao  Xu 《Chromatographia》2016,79(23):1659-1663

A sensitive and simple HPLC method for simultaneous determination of PAC-1 (first procaspase-activating compound), phenol red, and permeability markers (carbamazepine and furosemide) in perfusion samples was developed and validated to assess intestinal absorption of PAC-1 using single-pass intestinal perfusion technique (SPIP) in rats. The chromatographic separation was carried out on a Kromasil C18 column (150 mm × 4.6 mm, 5 μm) with acetonitrile–methanol–30 mmol L−1 phosphate buffer (pH 3.0, 25:10:65, v/v/v) as mobile phase at a flow rate of 1.0 mL min−1, and the wavelength of the UV detector was set at 281 nm. The calibration curves were linear in the ranges of 2.40–48.0 μg mL−1 for PAC-1; 3.60–72.0 μg mL−1 for carbamazepine; 3.20–64.0 μg mL−1 for furosemide, and 4.80–96.0 μg mL−1 for phenol red (r > 0.999). Both the intra- and inter-day precisions (RSD%) of all analytes were less than 6.8 % at three concentration levels, while accuracy ranged from 95.4 to 104.5 %. Data obtained in all method validation studies indicated that the method was suitable for the intended purpose. The effective permeability values (P eff) considering water flux with the help of non-permeable marker phenol red was calculated to be 0.42 × 10−4, 0.62 × 10−4, 0.32 × 10−4 cm s−1 for PAC-1; 0.72 × 10−4, 0.77 × 10−4, 0.52 × 10−4 cm s−1 for carbamazepine; 0.20 × 10−4, 0.16 × 10−4, 0.12 × 10−4 cm s−1 for furosemide in duodenum, jejunum and ileum, respectively. The P eff value can be increased by co-perfusion with verapamil, indicating that absorption of PAC-1 is efficiently transported by P-glycoprotein (P-gp) in the gut wall.

  相似文献   

6.

A simple and rapid development of a stability-indicating LC method for determination of chloroquine diphosphate in the presence of its hydrolysis, oxidative and photolysis degradation products is described. Stress testing showed that chloroquine diphosphate was degraded under basic conditions and by photolytic treatment but was stable under the other stress conditions investigated. Separation of the drug from its degradation products was achieved with a Nova Pack C18 column, 0.01 M PIC B7 and acetonitrile (40:60 v/v) pH 3.6, as mobile phase. Response was linear over the range 0.08–5.70 μg mL−1 (= 0.996), with limits of detection and quantification (LOD and LOQ) of 0.17 and 0.35 μg mL−1, respectively.

  相似文献   

7.

A simple, reproducible, and efficient liquid chromatographic method was developed with UV detection. Water (0.05% TFA):acetonitrile (0.05% TFA) was used as the mobile phase in a gradient system for the determination of procyanidin B2 (PB2) and epicatechin (EC) in the bark of Guazuma ulmifolia Lam. The analysis was performed using a Phenomenex Gemini RP C18 column (5 μm) as stationary phase, at 30 °C, with a flow rate of 0.8 mL min−1, at a wavelength of 210 nm for detection and determination. The main validation parameters of the method were also determined. Calibration curves were found to be linear, with ranges of 20.00–150.00 (PB2) and 10.00–110.00 μg mL−1 (EC). The correlation coefficients of linear regression analysis were between 0.9981 and 0.9988, and the detection limits were between 2.89 and 2.54 μg mL−1. The contents of PB2 and EC were successfully determined, with satisfactory reproducibility and recovery. Recoveries of the PB2 and EC were 103.00 and 104.01%, respectively. The method was successfully applied to the determination of procyanidins in the bark of G. ulmifolia.

  相似文献   

8.
Lu  Yingnian  Wu  Kefeng  Liang  Nianci  Chen  George G. 《Chromatographia》2009,70(11):1599-1603

ent-11α-Hydroxy-15-oxo-kaur-16-en-19-oic acid (5F), a diterpenoid isolated from the Chinese herb Pteris semipinnata L, has been suggested to show antitumor properties. A simple and sensitive LC method was developed for the determination of 5F in rabbit plasma. The method involved liquid–liquid extraction using ethyl acetate under acidic conditions using naproxen as an internal standard. Separations were performed on a reversed-phase column with a mixture of 1% (v/v) glacial acetic acid and methanol (45:55, v/v) as mobile phase and UV detection was utilized at 242 nm. The calibration plot was linear in the range 0.20–10.0 μg mL−1 (correlation coefficients r 2 > 0.998). The detection limit was 0.20 μg mL−1, mean extraction recovery was above 82%, intra-day precision of the method was less than 6.4%, and inter-day precision was better than 8.7%, respectively. The validated assay was found to be suitable for the pharmacokinetic study of 5F in rabbits.

  相似文献   

9.
Jin  Wei  Yang  Yong-Jian  Wang  Wei-Yu  Ye  Jian-Nong 《Chromatographia》2009,69(11):1221-1226

A suitable method that allows, for the first time, the simultaneous determination of nine antibiotics which may help the therapy of acne vulgaris by rapid liquid chromatography with diode array detection in 7 min is presented in this work. An SB RP18 (50 × 4.6 mm; 1.8 μm particle size) column was used with the mobile phase consisting of a mixture of 0.1 mol L−1 potassium dihydrogen phosphate (pH 2.5) and acetonitrile at the gradient elution program. The correlation coefficients were all above 0.9999 in the linear range between 4–100 μg mL−1, the average spiked recoveries (n = 6) were 92.2–103.2% with RSD ranging from 0.04 to 4.5% depending on the target analytes. The method detection limits were in the range of 0.02–0.2 μg mL−1 in anti-acne cosmetics. The analysis of real cosmetic preparations demonstrated the fitness for the whole analytical procedure. The proposed method appeared therefore as a sound alternative for official testing method, which could overcome the general problems of time consuming, lack of the specificity and precision difficulty.

  相似文献   

10.

A simple, rapid, and stability-indicating reversed-phase high-performance liquid chromatographic (LC) method for analysis for dutasteride has been successfully developed. Chromatography was performed on a 150 mm × 4.6 mm C18 column with acetonitrile–water 60:40 (v/v) as isocratic mobile phase at 1.0 mL min−1. Ultraviolet detection of dutasteride was at 210 nm. Its retention time was approximately 10 min and its peak was symmetrical. Response was a linear function of concentration over the range 0.2–1 μg mL−1 (R 2 = 0.997) and the limits of detection and quantitation were was 0.05 and 0.10 μg mL−1, respectively. The method was validated for linearity, precision, repeatability, sensitivity, and selectivity. Selectivity was validated by subjecting dutasteride stock solution to photolytic, acidic, basic, oxidative, and thermal degradation. The peaks from the degradation products did not interfere with that from dutasteride. The method was used to quantify dutasteride in pharmaceutical preparations.

  相似文献   

11.
Belal  Fathalla  Elbrashy  Amina  Eid  Manal  Nasr  Jenny Jeehan 《Chromatographia》2009,69(11):1201-1209

A simple, stability-indicating, reversed-phase liquid chromatographic method was developed for the determination of lacidipine in the presence of its degradation products. The analysis was carried out using a 150 mm × 4.6 mm i.d., 5 μm particle size Nucleodur MN-C18 column. Mobile phase containing a mixture of acetonitrile and 0.02 M phosphate buffer (70:30) at pH = 5.0 was pumped at a flow rate of 1 mL min−1 with UV-detection at 254 nm. The method showed good linearity in the range of 0.06–15 μg mL−1 with a limit of detection (S/N = 3) of 0.016 μg mL−1 (3.5 × 10−8 M). The suggested method was successfully applied for the analysis of lacidipine in bulk and in commercial tablets with average recoveries of 100.19 ± 0.81% and 100.05 ± 0.69%, respectively. The results were favorably compared to those obtained by a reference method. The suggested method was utilized to investigate the kinetics of alkaline, acidic, peroxide and photo-induced degradation of the drug. The apparent first-order rate constant, half-life times and activation energies of the degradation process were calculated. The pH profile curve was derived. The proposed method was successfully applied to the content uniformity testing of tablets.

  相似文献   

12.
Xu  Fan  Xu  Guili  Shang  Beicheng  Yu  Fang 《Chromatographia》2009,69(11):1421-1426

A simple, specific and sensitive liquid chromatographic method has been developed for the assay of ketorolac in human plasma and urine. The clean-up of plasma and urine samples were carried out by protein precipitation procedure and liquid–liquid extraction, respectively. Separation was performed by a Waters sunfire C18 reversed-phase column maintained at 35 °C. The mobile phase was a mixture of 0.02 M phosphate buffer (pH adjusted to 4.5 for plasma samples and to 3.5 for urine samples) and acetonitrile (70:30, v/v) at a flow rate of 1.0 mL min−1. The UV detector was set at 315 nm. Nevirapine was used as an internal standard in the assay of urine sample. The method was validated over the concentration range of 0.05–8 and 0.1–10 μg mL−1 for ketorolac in human plasma and urine, respectively. The limits of detection were 0.02 and 0.04 μg mL−1 for plasma and urine estimation at a signal-to-noise ratio of 3. The limits of quantification were 0.05 and 0.1 μg mL−1 for plasma and urine, respectively. The extraction recoveries were found to be 99.3 ± 4.2 and 80.3 ± 3.7% for plasma and urine, respectively. The intra-day and inter-day standard deviations were less than 0.5. The method indicated good performance in terms of specificity, linearity, detection and quantification limits, precision and accuracy. This assay demonstrated to be applicable for clinical pharmacokinetic studies.

  相似文献   

13.

Mercury exists in two forms in environment, inorganic salts and organic compounds. Determination of mercury is very important, due to its health effects. In the present research, diphenylation of mercury using phenylboronic acid as a derivatization reagent was used for the determination of Hg(II) in real water samples. A simple, rapid and cheap method named dispersive liquid–liquid microextraction was used for the extraction of analyte under the following conditions: extraction solvent 16 μL of carbon tetrachloride, disperser solvent 1 mL of ethanol and sample volume 5 mL. Under the optimal conditions, the enrichment factor for diphenylmercury was 931 and the limit of detection calculated on the basis of five replicates was 0.004 μg mL−1. The repeatability of the method expresses as relative standard deviation was 5.1 (n = 6). The linear range was between 0.01 and 10 μg mL−1. The performance of the proposed technique was evaluated for the determination of mercury in different environmental water samples.

  相似文献   

14.

An LC-DAD method was developed for determination of lobeline from in vitro and in vivo cultures of Lobelia inflata. Samples were extracted with 0.1 N HCl–acetonitrile (1:1, v/v), and purified by solid-phase extraction. Optimized conditions resulted in high recovery. LC separations were performed on an Eurosphere C8 reversed-phase column using 30:70 (v/v) acetonitrile–0.1% trifluoroacetic acid as a mobile phase. Quantitative determination of lobeline was performed by external standard method at 250 nm, in the range of 2.4–80 μg mL−1. Validation studies proved that the repeatability of the method was good and the recovery was satisfactory. In vitro organized cultures contained considerable amount of lobeline (herb: 175 μg g−1, root: 100 μg g−1). When these cultures were transplanted into the open field, the lobeline content increased significantly (herb: 323 μg g−1, root: 833 μg g−1). Plants obtained from seed propagation contained 382 μg g−1 lobeline in the herb. For direct characterization of di-substituted piperidine alkaloids in extracts of L. inflata, tandem mass spectrometric method was developed using electrospray ionization. Analysis was performed in the positive ion mode on a triple quadropole LC–MS system. LC separations were achieved on Eurosphere C8 column with a modified mobile phase (acetonitrile–30 mM ammonium formate, pH 2.80) to ensure proper molecular ionization. The identification and structural elucidation of the alkaloids were performed by comparing their changes in molecular mass (ΔM), full-scan MS–MS spectra with those of lobeline, norlobelanine and lobelanidine. These alkaloids and ten other derivatives were identified in the plant extracts. Three piperidine alkaloids were reported in L. inflata for the first time.

  相似文献   

15.
Yang  Xiao-ming  Zhang  Xiu-li  Chen  Yong-chang  Liu  Fang 《Chromatographia》2009,69(5-6):593-596

A sensitive and simple LC method for the quantification of ginkgolic acids in mice plasma has been developed. Following acetonitrile deproteinization, samples were separated on a SinoChrom ODS-AP C18 column. The mobile phase was 3% (v/v) acetic acid water solution–methanol (8:92, v/v) at a flow rate of 1.0 mL min−1. Detection was at 310 nm. Calibration curve was linear over the range of 0.25–50 μg mL−1 with intra- and inter-day precisions (RSD%) of less than 9.5%. The extraction recovery ranged from 87.0 to 90.2% (RSD 2.4–6.4%) for ginkgolic acids. The method was successfully applied to the pharmacokinetic study of ginkgolic acids in mice after oral dosing of 1.0 g kg−1.

  相似文献   

16.
Xiong  Xunyu  Zhang  Qunzheng  Xiong  Fengmei  Tang  Yuhai 《Chromatographia》2008,67(11):929-934

A simple and sensitive method was developed for the determination of three nonsteroidal anti-inflammatory drugs (NSAIDs)—ibuprofen, naproxen and fenbufen in human plasma. The method involved in column liquid chromatographic separation and chemilumenescence (CL) detection based on the CL reaction of NSAIDs, potassium permanganate (KMnO4) and sodium sulfite (Na2SO3) in sulfuric acid (H2SO4) medium. The chromatographic separation was carried out using a reversed-phase C18 column, which allowed the selective determination of the three medicines in the complicated samples. The special features of the CL detector provided lower LOD for determination than that of existing chromatographic alternatives. The results indicated that the linear ranges were 0.01–10.0 μg mL−1 for ibuprofen, 0.001–1.0 μg mL−1 for naproxen, and 0.01–10.0 μg mL−1 for fenbufen. The limits of detection were 0.5 ng mL−1 for ibuprofen, 0.05 ng mL−1 for naproxen and 0.5 ng mL−1 for fenbufen (S/N = 3). All average recoveries were in the range of 90.0–102.3%. Finally, the method had been satisfactorily applied for the determination of ibuprofen, naproxen and fenbufen in human plasma samples.

  相似文献   

17.
Zhang  Wei-Dong  Qi  Lian-Wen  Yang  Xiao-Lin  Lu  Yao-Wen  Li  Ping  Yang  Zhong-Lin 《Chromatographia》2008,67(11):1021-1022

A simple, sensitive, and validated liquid chromatographic method has been developed for the determination of tectorigenin in rat plasma and application to a pharmacokinetic study after oral administration of tectorigenin or its prodrug tectoridin. The analysis was performed on a Kromasil C18 analytical column using gradient elution with acetonitrile 0.1% phosphonic acid water at 0.8 mL min−1. The detection wavelength for UV detection was set at 264 nm. The established method was fully validated with parameters as follows: the intra- and inter-day assay precisions (CV) of three analytes were in the range of 4.2–13.3% and accuracies were between 98.0 and 107.5%; the calibration curve was linear with r 2 > 0.99 over a concentration range of 0.02–2 μg mL−1; the lower limit of quantification was 0.02 μg mL−1; tectorigenin showed stable in rat plasma after 12 h incubation at room temperature, 15 days storage at −80 °C and three freeze/thaw cycles, as well as in reconstitute buffer for 24 h at 25 °C; and the mean recoveries of tectorigenin were 92.3 ± 3.2, 95.5 ± 2.9 and 94.5 ± 3.0% with quality control levels of 0.02, 0.2 and 2 μg mL−1, respectively. In conclusion, this method is simple, economic, and sensitive enough for in vivo pharmacokinetic studies of tectorigenin.

  相似文献   

18.
Liu  Yongmei  Liao  Mengya  Zhang  Cuiwei  Bai  Yuli  Song  Honglian  Zhang  Yiwen  Wang  Xin 《Chromatographia》2015,78(23):1485-1489

A precise and sensitive LC method for the determination of repertaxin enantiomeric purity has been developed and validated. Baseline separation with a resolution higher than 2.0 was accomplished within 20 min using a Chiralpak AD-H column (250 × 4.6 mm; particle size 5 μm) and n-hexane:2-propanol (90:10 v/v) as mobile phase at a flow rate of 1 mL min−1. Eluted analytes were monitored by UV detection at 260 nm. The effects of mobile phase composition, temperature and flow rate on enantiomeric selectivity and on resolution of enantiomers were investigated. Calibration curves were plotted within the concentration range between 0.002 and 1.0 mg mL−1 (n = 3), and relative standard deviation (RSD) of the inter-batch assay and intra-batch assay was less than 1.27 and 1.16 %. LOD and LOQ for repertaxin were 0.65 and 2.19 μg mL−1; those for its enantiomer were 0.70 and 2.34 μg mL−1, respectively. The method was evaluated and validated by analysis of bulk samples of repertaxin of different enantiomeric purity. It was demonstrated that the method was accurate, robust, and sensitive, and enabled practical analysis of real samples.

  相似文献   

19.
Dogan-Topal  B.  Ozkan  S. A.  Uslu  B. 《Chromatographia》2007,66(1):25-30

A rapid, sensitive, and specific reverse phase high performance liquid chromatography with diode array detection procedure for the simultaneous determination of abacavir, efavirenz and valganciclovir in spiked human serum is described. Separation was performed on a 5 μm Waters Spherisorb column (250 × 4.6 mm ID) with acetonitrile: methanol:KH2PO4 (at pH 5.00) (40:20:40 v/v/v) isocratic elution at a flow rate of 1.0 mL min−1. Calibration curves were constructed in the range of 50–30,000 ng mL−1 for abacavir and efavirenz, and 10–30,000 ngmL−1 for valganciclovir in serum samples. The limit of detection and limit of quantification concentrations of the HPLC method were 3.80 and 12.68 ng mL−1 for abacavir, 2.61 and 8.69 ng mL−1 for efavirenz, 1.30 and 4.32 ng mL−1 for valganciclovir. The method has been applied, without any interference from excipients or endogenous substances, for the simultaneous determination of these three compounds in human serum.

  相似文献   

20.
Deng  Weijie  Zhang  Xiangnian  Sun  Zhiping  Yin  Jilin  Zhou  Zheng  Han  Liping  Zhao  Shujin 《Chromatographia》2012,75(11):629-633

A new and simple high-performance liquid chromatography with evaporative light scattering detector method for the determination of Kryptofix 2.2.2 (K-222) in the radiopharmaceuticals of 2-deoxy-2-[18F]fluoro-d-glucose ([18F]FDG) and 3′-deoxy-3′-[18F]fluorothymidine ([18F]FLT) was developed. A C18 column was used and the mobile phase was 10 % (v/v) methanol and 90 % (v/v) water (0.1 % trifluoroacetic acid, v/v) at a flow rate of 0.2 mL min−1. The drift tube temperature was 40 °C. The pressure of nebulizing gas (N2) was 3.0 bar. The gain was 10. Good separation of K-222 from main related substances could be achieved. Excellent linearity (r 2 = 0.9995) was obtained over the range of 5–100 μg mL−1. The precision ranged from 0.68 to 5.16 % (RSD) and the accuracy ranged from −3.05 to 2.62 % (RE). The limit of detection was 2 μg mL−1. This method offers simple, rapid and quantitative detection of K-222, thus making it acceptable for routine determination.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号