首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Thin-layer chromatography (TLC) is a widely used, fast and inexpensive method for separating complex mixtures. Unfortunately, the quality of achievable separation represents only one side. An additional problem is the unambiguous assignment of the obtained spots to defined compounds. Clear identification of spots is often not possible by common staining methods and comparison with a known reference compound. Therefore, further analytical techniques are mostly required for further structural elucidation. Mass spectrometry (MS) is a suitable method due to its high sensitivity. In particular, matrix-assisted laser desorption and ionization time-of-flight (MALDI-TOF) MS is a modern soft-ionization technique that may be easily combined with TLC. This review summarizes the so far available knowledge about direct TLC–MALDI combination and gives an overview about different molecule classes that have already been successfully analyzed by this approach. This review critically summarizes the capabilities and limitations of the direct MALDI–TLC combination and highlights in particular the problems related to sample preparation and instrumentation.

  相似文献   

2.
A straightforward procedure for direct mass spectrometric (MS) analysis of spots from thin layer chromatography (TLC) plates, without the need of an external ion source, was developed using the aluminum plate backing as spray tip. The spots were cut out shaped as a tip with a 60° angle, mounted in front of the MS orifice, and after addition of a spray solvent spectra were obtained immediately. A high-resolution time-of-flight MS was used since the method is of particular interest for rapid identification or confirmation of spots from TLC plates. The practical benefits of this technique were demonstrated by detection of by-products of organic reactions, by identification of degradation products, and by accurate confirmation of spots when UV filters in sunscreens were analyzed by TLC. Employing the described method TLC spots can be evaluated fast without the need of an external ion source or devices for analyte transfer from TLC to MS, only a basic MS instrument and a high-voltage power supply is required.
Figure
Photograph of the thin layer chromatography-spray mass spectrometry instrumental setup  相似文献   

3.
Rapid and precise identification of toxic substances is necessary for urgent diagnosis and treatment of poisoning cases and for establishing the cause of death in postmortem examinations. However, identification of compounds in biological samples using gas chromatography and liquid chromatography coupled with mass spectrometry entails time-consuming and labor-intensive sample preparations. In this study, we examined a simple preparation and highly sensitive analysis of drugs in biological samples such as urine, plasma, and organs using thin-layer chromatography coupled with matrix-assisted laser desorption/ionization mass spectrometry (TLC/MALDI/MS). When the urine containing 3,4-methylenedioxymethamphetamine (MDMA) without sample dilution was spotted on a thin-layer chromatography (TLC) plate and was analyzed by TLC/MALDI/MS, the detection limit of the MDMA spot was 0.05 ng/spot. The value was the same as that in aqueous solution spotted on a stainless steel plate. All the 11 psychotropic compounds tested (MDMA, 4-hydroxy-3-methoxymethamphetamine, 3,4-methylenedioxyamphetamine, methamphetamine, p-hydroxymethamphetamine, amphetamine, ketamine, caffeine, chlorpromazine, triazolam, and morphine) on a TLC plate were detected at levels of 0.05 − 5 ng, and the type (layer thickness and fluorescence) of TLC plate did not affect detection sensitivity. In addition, when rat liver homogenate obtained after MDMA administration (10 mg/kg) was spotted on a TLC plate, MDMA and its main metabolites were identified using TLC/MALDI/MS, and the spots on a TLC plate were visualized by MALDI/imaging MS. The total analytical time from spotting of intact biological samples to the output of analytical results was within 30 min. TLC/MALDI/MS enabled rapid, simple, and highly sensitive analysis of drugs from intact biological samples and crude extracts. Accordingly, this method could be applied to rapid drug screening and precise identification of toxic substances in poisoning cases and postmortem examinations.  相似文献   

4.
This paper presents a critical review of off-line and on-line coupling of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry to liquid column separations (e.g. HPLC, GPC and CE) and planar separations (e.g. PAGE and TLC). Off-line MALDI analysis of fractions collected from HPLC, GPC and CE or spots scraped and extracted from TLC and PAGE has already become a routine practice for many laboratories. MALDI has also been used to obtain mass spectra directly from TLC plates and PAGE. The direct analysis methods range from dot-blotted samples to two-dimensional scanning of the entire gels/plates. Various combinations of on-line coupling of MALDI with column separations are also reviewed. The review discusses the strengths and limitations associated with different off-line and on-line coupling approaches.  相似文献   

5.
This paper presents a critical review of off-line and on-line coupling of matrix-assisted laser desorption/ ionization (MALDI) mass spectrometry to liquid column separations (e.g. HPLC, GPC and CE) and planar separations (e.g. PAGE and TLC). Off-line MALDI analysis of fractions collected from HPLC, GPC and CE or spots scraped and extracted from TLC and PAGE has already become a routine practice for many laboratories. MALDI has also been used to obtain mass spectra directly from TLC plates and PAGE. The direct analysis methods range from dot-blotted samples to two-dimensional scanning of the entire gels/plates. Various combinations of on-line coupling of MALDI with column separations are also reviewed. The review discusses the strengths and limitations associated with different off-line and on-line coupling approaches.  相似文献   

6.
Yang Y  Thannhauser TW  Li L  Zhang S 《Electrophoresis》2007,28(12):2080-2094
With 2-D gel mapping, it is often observed that essentially identical proteins migrate to different positions in the gel, while some seemingly well-resolved protein spots consist of multiple proteins. These observations can undermine the validity of gel-based comparative proteomic studies. Through a comparison of protein identifications using direct MALDI-TOF/TOF and LC-ESI-MS/MS analyses of 2-D gel separated proteins from cauliflower florets, we have developed an integrated approach to improve the accuracy and reliability of comparative 2-D electrophoresis. From 46 spots of interest, we identified 51 proteins by MALDI-TOF/TOF analysis and 108 proteins by LC-ESI-MS/MS. The results indicate that 75% of the analyzed spots contained multiple proteins. A comparison of hit rank for protein identifications showed that 37 out of 43 spots identified by MALDI matched the top-ranked hit from the ESI-MS/MS. By using the exponentially modified protein abundance index (emPAI) to determine the abundance of the individual component proteins for the spots containing multiple proteins, we found that the top-hit proteins from 40 out of 43 spots identified by MALDI matched the most abundant proteins determined by LC-MS/MS. Furthermore, our 2-D-GeLC-MS/MS results show that the top-hit proteins in 44 identified spots contributed on average 81% of the spots' staining intensity. This is the first quantitative measurement of the average rate of false assignment for direct MALDI analysis of 2-D gel spots using a new integrated workflow (2-D gel imaging, "2-D GeLC-MS/MS", and emPAI analysis). Here, the new approach is proposed as an alternative to traditional gel-based quantitative proteomics studies.  相似文献   

7.
The investigation of a combined thin-layer chromatography/matrix-assisted laser desorption/ionization mass spectrometry (TLC/MALDI-MS) method for the analysis of siderophores from microbial samples is described. The investigated siderophores were enterobactin, ferrioxamine B, ferrichrome, ferrirhodin, rhodotorulic acid and coprogen. Solid-phase extraction was employed to recover the siderophores from the microbial samples. After visualization of the spots via spraying with ferric chloride or chrome azurol sulfonate assay solution, the MALDI matrix was applied to the gel surface. Several TLC/MALDI experimental parameters were optimized, such as type and concentration of MALDI matrix, as well as the type and composition of solvent to facilitate analyte transport from the inside of the TLC gel to the surface. The impact of these parameters on sensitivity, precision and ion formation of the various siderophores was studied. The detection limits for the investigated siderophores were in the range 1-4 pmol. These values were about 4-24 times higher than the detection limits obtained directly from stainless steel MALDI targets. The differences were most likely due to incomplete transport of the 'trapped' analyte molecules from the deeper layers of the TLC gel to the surface and into the matrix layer. In addition, chromatographic band broadening spread the analyte further in TLC as compared with the steel plates, resulting in less analyte per surface area. The identification of the siderophores was aided by concurrently applying a Ga(III) nitrate solution to the TLC plate during the visualization step. The resulting formation of Ga(III) complexes lead to distinctive (69)Ga/(71)Ga isotope patterns in the mass spectra. The versatility of the TLC/MALDI-MS assay was demonstrated by using it to analyze siderophores in a Pseudomonas aeruginosa sample. An iron-binding compound was identified in the sample, namely pyochelin (2-(2-o-hydroxyphenyl-2-thiazolin-4-yl)-3-methylthiazolidine-4-carboxylic acid).  相似文献   

8.
Thin layer chromatography (TLC)--a simple, cost-effective, and easy-to-operate planar chromatographic technique--has been used in general chemistry laboratories for several decades to routinely separate chemical and biochemical compounds. Traditionally, chemical and optical methods are employed to visualize the analyte spots on the TLC plate. Because direct identification and structural characterization of the analytes on the TLC plate through these methods are not possible, there has been long-held interest in the development of interfaces that allow TLC to be combined with mass spectrometry (MS)--one of the most efficient analytical tools for structural elucidation. So far, many different TLC-MS techniques have been reported in the literature; some are commercially available. According to differences in their operational processes, the existing TLC-MS systems can be classified into two categories: (i) indirect mass spectrometric analyses, performed by scraping, extracting, purifying, and concentrating the analyte from the TLC plate and then directing it into the mass spectrometer's ion source for further analysis; (ii) direct mass spectrometric analyses, where the analyte on the TLC plate is characterized directly through mass spectrometry without the need for scraping, extraction, or concentration processes. Conventionally, direct TLC-MS analysis is performed under vacuum, but the development of ambient mass spectrometry has allowed analytes on TLC plates to be characterized under atmospheric pressure. Thus, TLC-MS techniques can also be classified into two other categories according to the working environment of the ion source: vacuum-based TLC-MS or ambient TLC-MS. This review article describes the state of the art of TLC-MS techniques used for indirect and direct characterization of analytes on the surfaces of TLC plates.  相似文献   

9.
A novel method for on-tissue identification of proteins in spatially discrete regions is described using tryptic digestion followed by matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS) with MS/MS analysis. IMS is first used to reveal the protein and peptide spatial distribution in a tissue section and then a serial section is robotically spotted with small volumes of trypsin solution to carry out in situ protease digestion. After hydrolysis, 2,5-Dihydroxybenzoic acid (DHB) matrix solution is applied to the digested spots, with subsequent analysis by IMS to reveal the spatial distribution of the various tryptic fragments. Sequence determination of the tryptic fragments is performed using on-tissue MALDI MS/MS analysis directly from the individual digest spots. This protocol enables protein identification directly from tissue while preserving the spatial integrity of the tissue sample. The procedure is demonstrated with the identification of several proteins in the coronal sections of a rat brain.  相似文献   

10.
Comparative MS/MS studies of singly and doubly charged electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) precursor peptide ions are described. The spectra from these experiments have been evaluated with particular emphasis on the data quality for subsequent data processing and protein/amino acid sequence identification. It is shown that, once peptide ions are formed by ESI or MALDI, their charge state, as well as the collision energy, is the main parameter determining the quality of collision-induced dissociation (CID) MS/MS fragmentation spectra of a given peptide. CID-MS/MS spectra of singly charged peptides obtained on a hybrid quadrupole orthogonal time-of-flight mass spectrometer resemble very closely spectra obtained by matrix-assisted laser desorption/ionization post-source decay time-of-flight mass spectrometry (MALDI-PSD-TOFMS). On the other hand, comparison of CID-MS/MS spectra of either singly or doubly charged ion species shows no dependence on whether ions have been formed by ESI or MALDI. This observation confirms that, at the time of precursor ion selection, further mass analysis is effectively decoupled from the desorption/ionization event. Since MALDI ions are predominantly formed as singly charged species and ESI ions as doubly charged, the associated difference in the spectral quality of MS/MS spectra as described here imposes direct consequences on data processing, database searching using ion fragmentation data, and de novo sequencing when ionization techniques are changed.  相似文献   

11.
Fluorescent semiconductor quantum dots (QDs) exhibit great potential and capability for many biological and biochemical applications. We report a simple strategy for the synthesis of aqueous stable ZnSe QDs by using cysteine as the capping agent (ZnSe‐Cys QDs). The ZnSe QDs can act as affinity probes to enrich peptides and proteins via direct matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS) analysis. This nanoprobe could significantly enhance protein signals (insulin, ubiquitin, cytochrome c, myoglobin and lysozyme) in MALDI‐TOFMS by 2.5–12 times compared with the traditional method. Additionally, the ZnSe‐Cys QDs can be applied as heat absorbers (as accelerating probes) to speed up microwave‐assisted enzymatic digestion reactions and also as affinity probes to enrich lysozyme‐digested products in MALDI‐TOFMS. Furthermore, after the enrichment experiments, the solutions of ZnSe‐Cys QDs mixed with proteins can be directly deposited onto the MALDI plates for rapid analysis. This approach shows a simple, rapid, efficient and straightforward method for direct analysis of proteins or peptides by MALDI‐TOFMS without the requirement for further time‐consuming separation processes, tedious washing steps or laborious purification procedures. The present study has demonstrated that ZnSe‐Cys QDs are reliable and potential materials for rapid, selective separation and enrichment of proteins as well as accelerating probes for microwave‐digested reactions for proteins than the regular MALDI‐MS tools. Additionally, we also believe that this work may also inspire investigations for applications of QDs in the field of MALDI‐MS for proteomics. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
The identification of the four principal triterpenoid components of Centella asiatica has been achieved by TLC on silica gel plates and mass spectrometry, as a modification of the method described in the European Pharmacopoeia (5th edn). A combination of ethyl acetate and methanol as the mobile phase was found to be successful in separating these compounds from the rest of the main components of the extract. The spots were detected with anisaldehyde solution. The separated compounds were confirmed by MALDI -TOF mass spectrometry.  相似文献   

13.
Glycosphingolipids (GSLs) play key roles in the manifestation of infectious diseases as attachment sites for pathogens. The thin‐layer chromatography (TLC) overlay assay represents one of the most powerful approaches for the detection of GSL receptors of microorganisms. Here we report on the direct structural characterization of microbial GSL receptors by employment of the TLC overlay assay combined with infrared matrix‐assisted laser desorption/ionization orthogonal time‐of‐flight mass spectrometry (IR‐MALDI‐o‐TOF‐MS). The procedure includes TLC separation of GSL mixtures, overlay of the chromatogram with GSL‐specific bacteria, detection of bound microbes with primary antibodies against bacterial surface proteins and appropriate alkaline phosphatase labeled secondary antibodies, and in situ MS analysis of bacteria‐specific GSL receptors. The combined method works on microgram scale of GSL mixtures and is advantageous in that it omits laborious and time‐consuming GSL extraction from the silica gel layer. This technique was successfully applied to the compositional analysis of globo‐series neutral GSLs recognized by P‐fimbriated Escherichia coli bacteria, which were used as model microorganisms for infection of the human urinary tract. Thus, direct TLC/IR‐MALDI‐o‐TOF‐MS adds a novel facet to this fast and sensitive method offering a wide range of applications for the investigation of carbohydrate‐specific pathogens involved in human infectious diseases. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
In this study, we present a rapid and simple method for the separation and direct detection of glutathione by combining gold nanoparticles and MALDI–TOF‐MS with graphene as matrix. Gold nanoparticles enable the selective capture of thiol‐containing compounds. Gold nanoparticles bound with analytes can be mixed with graphene matrix for direct analysis by MALDI–TOF‐MS, which can avoid sample loss and contamination during transfer process. Compared with a conventional matrix, α‐cyano‐4‐hydroxycinnamic acid, graphene exhibits an excellent desorption/ionization efficiency, thermal and mechanical properties. The use of graphene as matrix avoids the fragmentation of analytes. Stable analysis was achieved with less background interference even at the concentration of 0.625 ng/μL. To further confirm its efficiency, the optimized approach was applied to the separation and detection of glutathione in mouse liver extraction. This result showed the great potential of detection of biologically important thiols in biochemical and biomedical research.  相似文献   

15.

Thin-layer chromatography (TLC) is a simple, fast and inexpensive separation method which can be applied to virtually all natural products including oligosaccharides. Unfortunately, however, the unequivocal identification of a TLC spot is normally difficult. Fortunately, this problem can be minimized when mass spectrometry (MS) such as matrix-assisted laser desorption and ionization time-of-flight is used to identify the TLC spots. This work is dedicated to the TLC/MS analysis of oligosaccharides derived from native chondroitin sulfate and hyaluronan. We will show that the thickness of the silica gel layer (200 versus 100 µm) has a tremendous influence on the quality of the mass spectra: a reduced silica gel thickness enhances the spectral quality and, in particular, improves the achievable signal-to-noise ratio. Additionally, unwanted formylation of the GAG oligosaccharides (which occurs due to the high moiety of formic acid in the mobile phase) can also be minimized if MS-grade HPTLC plates are used.

  相似文献   

16.
Although the most important application of matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) is "proteomics," there is growing evidence that this soft ionization method is also useful for phospholipid (PL) analysis. Although all PLs are detectable by MALDI-TOF MS, some lipid classes, particularly those with quaternary amines such as phosphatidylcholines (PCs), are more sensitively detected than others, and these suppress the signals of less sensitively detected PLs when complex mixtures are analyzed. Therefore, a separation of the total organic extract into individual lipid classes is necessary. As MALDI uses a solid sample, the direct evaluation of thin-layer chromatography (TLC) plates is possible. We report here on a method of directly coupling MALDI-TOF MS and TLC that can be easily implemented on commercially available MALDI-TOF devices. A total extract of hen egg yolk is used as a simple PL mixture to demonstrate the capabilities of this method. It will be shown that "clean" spectra without any major contributions from fragmentation products and matrix peaks can be obtained, and that this approach is even sensitive enough to detect the presence of PLs at levels of less than 1% of the total extract.  相似文献   

17.
A simple and robust impulse-driven droplet deposition system was developed for off-line liquid chromatography matrix-assisted laser desorption ionization mass spectrometry (LC-MALDI MS). The system uses a solenoid operated with a pulsed voltage power supply to generate impulses that dislodge the hanging droplets from the LC outlet directly to a MALDI plate via a momentum transfer process. There is no contact between the LC outlet and the collection surface. The system is compatible with solvents of varying polarity and viscosity, and accommodates the use of hydrophobic and hydrophilic MALDI matrices. MALDI spots are produced on-line with the separation, and do not require further processing before MS analysis. It is shown that high quality MALDI spectra from 5 fmol of pyro-Glu-fibrinopeptide deposition after LC separation could be obtained using the device, indicating that there was no sample loss in the interface. To demonstrate the analytical performance of the system as a proteome analysis tool, a range of BSA digest concentrations covering about 3 orders of magnitude, from 5 fmol to 1 pmol, were analyzed by LC-MALDI quadrupole time-of-flight MS, yielding 6 and 57% amino acid sequence coverage, respectively. In addition, a complex protein mixture of an E. coli cell extract was tryptically digested and analyzed by LC-MALDI MS, resulting in the detection of a total of 409 unique peptides from 100 fractions of 15-s intervals.  相似文献   

18.
Takashi Manabe  Ya Jin 《Electrophoresis》2010,31(16):2740-2748
Escherichia coli (strain K‐12)‐soluble proteins were analyzed by nondenaturing micro 2‐DE and MALDI‐MS‐PMF. The reported conditions of nondenaturing IEF in agarose column gels [Jin, Y., Manabe, T., Electrophoresis 2009, 30, 939–948] were modified to optimize the resolution of cellular soluble proteins. About 300 CBB‐stained spots, the apparent molecular masses of which ranged from ca. 6000 to 10 kDa, were detected. All the spots on two reference 2‐DE gels (one for wide mass range and one for low‐molecular‐mass range) were numbered and subjected to MALDI‐MS‐PMF for the assignment of constituting polypeptides. Most of the spots (310 spots out of 329) provided significant match (p<0.05) with polypeptides in Swiss‐Prot database and totally 228 polypeptide species were assigned. Activity staining of enzymes such as alkaline phosphatase and catalases was performed on the 2‐DE gels and the locations of the activity spots matched well with those of the MS‐assigned polypeptides of the enzymes. Most of the polypeptides with subunit information in Swiss‐Prot (119 polypeptides as homo‐multimers and 25 as hetero‐multimers out of the 228), such as pyruvate dehydrogenase complex which is composed of three enzymatic components, were detected at the apparent mass positions of their polymers, suggesting that the proteins were separated retaining their subunit structures. When a nondenaturing 2‐DE gel was vertically cut into 2 mm strips and one of the strips was subjected to a third‐dimension micro SDS‐PAGE (micro 3‐DE), about 190 CBB‐stained spots were detected. The assignment of the polypeptides separated on the 3‐DE gel would further provide information on protein/polypeptide interactions.  相似文献   

19.
李鹏章  王粤博 《化学进展》2012,(9):1785-1793
磷酸化作用是最重要的蛋白质翻译后修饰方式之一,它是蛋白质组学的一个重要分支,在细胞识别、细胞信息传递、基因表达和新陈代谢等方面发挥着重要作用。采用适当方法对磷酸化肽进行分析有助于我们更好地了解生理病理机制。但是直接进行质谱分析时磷酸化肽的信号强度会受到无机盐以及大量非磷酸化肽的抑制,选择性差。为解决这一难题,在质谱分析前要对磷酸化肽进行选择性富集。本文回顾了几种常用的磷酸化肽富集方法,介绍了每种方法的发展状况和常用材料,其中包括固定金属离子亲和色谱法、金属氧化物富集法、强阴阳离子交换色谱法和MALDI靶板富集法。最后总结了各种富集方法的优缺点,对有效的磷酸化肽富集策略进行了前景展望。  相似文献   

20.
A method has been developed for rapid and sensitive identification of epitope-containing peptides, based on direct MALDI-MS/MS analysis of epitope-containing peptides affinity bound to affinity beads. This technique provides sequence information of the epitope that allows unambiguous identification of the epitope either by database searching or de novo sequencing. With MALDI-MS, affinity beads with bound peptides can be placed directly on the MALDI target and analyzed. Coupling a MALDI source to an orthogonal injection quadrupole time-of-flight (QqTOF) mass spectrometer allows direct sequencing of the bound peptides. In contrast to ESI-MS/MS, elution of the affinity-bound peptides followed by additional concentration and purification steps is not required, thus reducing the potential for sample loss. Direct mass spectrometric sequencing of affinity-bound peptides eliminates the need for chemical or enzymatic sequencing. Other advantages of this direct MALDI-MS/MS analysis of epitope-containing peptides bound to the affinity beads include its sensitivity (femtomole levels) and speed. In addition, direct analysis of peptides on affinity beads does not adversely affect the high mass accuracy of a QqTOF, and database searching can be performed on the MS/MS spectra obtained. In proof-of-principle experiments, this method has been demonstrated on beads containing immobilized antibodies against phosphotyrosine, the c-myc epitope tag, as well as immobilized avidin. Furthermore, de novo sequencing of epitope-containing peptides is demonstrated. The first application of this method was with anti-FLAG-tag affinity beads, where direct MALDI MS/MS was used to determine an unexpected enzymatic cleavage site on a growth factor protein.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号