首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the simultaneous screening and confirmation of the presence of fourteen tertiary amine stimulants in human urine by gas chromatography-mass spectrometry (GC-MS) in combination with liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated. Solid phase extraction (SPE) and liquid-liquid extraction (LLE) approaches were utilized for the pre-treatment of the urine samples. The study indicated that the capillary temperature played a significant role in the signal abundances of the protonated molecules of cropropamide and crotethamide under positive ion electrospray ionization (ESI) conditions. In addition, comparison studies of two different pre-treatment approaches as well as the two ionization modes were conducted. The LODs of the developed method for all the analytes were lower than the minimum required performance limit (MRPL) as set forth in the World Anti-Doping Agency (WADA) technical document for laboratories. The human urine sample obtained after oral administration of prolintane·HCl was successfully analyzed by the developed method, which demonstrated the applicability and reliability of the method for routine doping control analysis.  相似文献   

2.
A confirmatory method for the determination of illicit drugs based on micro-solid phase extraction with modified tips, made of a functionalized fiberglass with apolar chains of octadecylsilane into monolithic structure, has been developed in this study. Drugs belonging to different chemical classes, such as amphetamine, methamphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, methylenedioxymethylamphetamine, cocaine, benzoylecgonine, ketamine, mescaline, phencyclidine and psilocybine were analyzed. The quantitation was performed by liquid chromatography-tandem mass spectrometry and the analytes were detected in positive ionization by means of an electrospray source. The limits of quantification ranged between 0.3 ng mL−1 for cocaine and 4.9 ng mL−1 for psilocybine, with coefficients of determination (r2) >0.99 for all the analytes as recommended in the guidelines of Society of Forensic Toxicologists-American Association Forensic Sciences.  相似文献   

3.
In this article, a laboratory-made sol-gel derived fiber with butyl methacrylate/hydroxy-terminated silicone oil (BMA/OH-TSO) coating was first used for headspace solid-phase microextraction (HS-SPME) of medium and long chain fatty acids after derivatization and applied to the analysis of fatty acids in lung tissues by coupling to gas chromatography-mass spectrometry (GC-MS). The experimental parameters for derivatization, HS-SPME and desorption were optimized. Fatty acids in cancerous lung tissues from five patients with lung cancer were determined under the optimized conditions. Normal lung tissues from the same five patients were used as controls. This fiber showed higher extraction efficiency for fatty acids after derivatization when compared with commercial polydimethylsiloxane (PDMS) and polydimethylsiloxane-divinylbenzene (PDMS/DVB) fibers due to the three-dimensional network in the coating. The method presented in this paper showed satisfactory precision, accuracy, linearity and limits of detection (LODs). The relative standard deviation values were below 13.3% (n = 5) and the recoveries obtained ranged from 76.35% to 107.0%. The results obtained using the SPME method were also compared with those got by using liquid-liquid extraction (LLE) technique. It was found that the sensitivity could be enhanced by the SPME method. The analysis of the cancerous lung tissues and normal controls from five patients with lung cancer indicated that the main components of lung tissue were palmitic acid (C16:0), stearic acid (C18:0) and lignoceric acid (C24:0). A comparison between the levels of the fatty acids in cancerous lung tissues and normal controls from the same a patient with lung cancer shows that most of the saturated fatty acids showed higher levels in cancerous lung tissues, while unsaturated fatty acids showed higher levels in normal controls on the whole.  相似文献   

4.
Fatty acids have multitudinous biological functions and play a crucial role in many biological processes, but due to poor ionization efficiency and lack of appropriate internal standards, the comprehensive quantification of fatty acids by liquid chromatography-tandem mass spectrometry is still challenging. In this study, a new, accurate, and reliable method for quantifying 30 fatty acids in serum using dual derivatization was proposed. Indole-3-acetic acid hydrazide derivants of fatty acids were used as the internal standard and indole-3-carboxylic acid hydrazide derivants of them were used to quantify. The derivatization conditions were systematically optimized and the method validation results showed good linearity with R2 > 0.9942, low detection limit (0.03–0.6 nM), precision (1.6%–9.8% for intra-day and 4.6%–14.1% for inter-day), recovery (88.2%–107.2% with relative standard deviation < 10.5%), matrix effect (88.3%–105.2% with the relative standard deviation < 9.9%) and stability (3.4%–13.8% for fatty acids derivants in 24 h at 4°C and 4.2%–13.8% for three freeze-thaw cycles). Finally, this method was successfully applied to quantify fatty acids in serum samples of Alzheimer's patients. In contrast to the healthy control group, nine fatty acids showed a significant increase in the Alzheimer's disease group.  相似文献   

5.
采用液液萃取和SPE净化提取水产品中的脱氢胆酸,并建立液相色谱-串联质谱的检验方法。样品以乙酸乙酯和二氯甲烷提取后采用C18柱进行分离,乙腈以及超纯水为流动相洗脱,电喷雾电离负离子模式扫描,多反应监测测定,外标法定量分析。标准溶液在0.05~2 ng/mL范围内呈线性关系,相关系数大于0.99,方法定量限为0.05μg/kg,平均回收率在90.4%~110.0%,相对标准偏差在6.5%~12%。  相似文献   

6.
建立了使用超高效液相色谱-串联质谱(UHPLC-MS/MS)高效、快速直接测定茶叶中游离氨基酸的方法。通过对质谱、色谱条件及氨基酸提取条件的优化,以含0.2%(体积分数)甲酸的5 mmol/L乙酸铵水溶液和甲醇为流动相进行梯度洗脱,在电喷雾离子(ESI)源正离子扫描模式下检测,通过UHPLC-MS/MS测定,共解析了茶叶中的20种氨基酸。结果表明,茶氨酸(Thea)、Arg、Asn和Asp在50~500 μg/L范围内线性关系良好,其他氨基酸在10~250 μg/L范围内线性关系良好,相关系数均大于0.99;加标回收率为92.3%~109.2%,相对标准偏差为2.00%~9.88%,检出限为0.001~0.011 mg/L,定量限为0.010~0.053 mg/L。该方法灵敏、准确,具有良好的重复性和稳定性,可有效检测出茶叶中的20种氨基酸及氨基类成分。  相似文献   

7.
周晓晴  吕小丽  万建春  郭平  郭丹  席慧婷 《色谱》2019,37(10):1064-1070
建立了一种测定奶粉中氯酸盐和高氯酸盐含量的高效液相色谱-串联质谱方法。样品经0.1%(v/v)甲酸水-乙腈提取,10000 r/min下离心10 min后,上清液经PRiME HLB固相萃取柱净化;采用离子交换色谱分离,色谱柱为Thermo Scientific Acclaim TRINITY P1复合离子交换柱(50 mm×2.1 mm,3 μm),以乙腈和20 mmol/L乙酸铵溶液为流动相进行梯度洗脱,MS/MS检测,内标法定量。结果显示,氯酸盐和高氯酸盐分别在2.0~40.0 μg/L和1.0~20.0 μg/L范围内线性关系良好,相关系数(r2)大于0.999,方法的定量限分别为15.0和7.5 μg/kg。氯酸盐和高氯酸盐分别在30.0、60.0、120.0 μg/kg和15.0、30.0、60.0 μg/kg 3个水平下的加标回收率为89.24%~107.85%,相对标准偏差为3.15%~10.42%(n=6)。该方法简便快捷、准确可靠,能适用于奶粉样品的测定。  相似文献   

8.
向平  沈敏  沈保华  严慧 《色谱》2008,26(4):469-472
采用液相色谱-串联质谱(LC-MS/MS)建立了毛发中司坦唑醇的分析方法,并将其应用于单次给药动物实验中的动物毛样品分析。将10 mg样品碱水解后加入戊烷提取,然后进行LC-MS/MS分析,采用正离子电喷雾电离、多反应监测模式测定,方法的最低定量限为25 pg/mg。剃去豚鼠背部中央的毛,以60 mg/kg的剂量于豚鼠腹腔注射司坦唑醇,然后隔天在同一部位剃取其毛,两周内该豚鼠毛中均能检出司坦唑醇;给药后豚鼠毛中司坦唑醇的含量在第1周内保持稳定,在给药后第10天达到峰值。所建立的方法毛发取样量少,特异性强,灵敏度高,适用于毛发中司坦唑醇的分析。  相似文献   

9.
林慧  徐春祥  颜春荣  张征  王岁楼 《色谱》2013,31(9):914-919
建立了牛肉中刚果红的检测方法。定性方法采用液相色谱-串联四极杆飞行时间质谱对未知物进行质谱谱图库匹配,定量分析采用超高效液相色谱-串联三重四极杆质谱。牛肉样品中的刚果红经液液萃取净化后,采用Agilent ZORBAX Eclipse Plus C18 Rapid Resolution HD色谱柱(50 mm×2.1 mm, 1.8 μm)进行分离,流动相为95%(体积分数)甲醇,流速为0.2 mL/min。AB 4000+三重四极杆质谱仪在电喷雾负离子化(ESI)及MRM模式下定量。结果显示,刚果红在0.03~1 mg/L浓度范围内,线性关系良好(相关系数为0.9998),精密度良好(RSD小于5%),回收率为88%~91%,检出限约为0.01 mg/L。本方法快速简便,重现性好,可以为牛肉及其他肉制品中刚果红的定量提供良好的解决方案。  相似文献   

10.
An improved analytical method for determination of human pharmaceuticals in natural and wastewaters with ng L−1 sensitivity is presented. The method is applicable to pharmaceuticals from a wide range of therapeutic classes including antibiotics, analgesics, anti-inflammatories and anti-cancer compounds. Pharmaceuticals were extracted from waters using solid-phase extraction, and after concentration, analysed by high performance liquid chromatography with tandem mass spectrometric detection (HPLC-MS/MS). Identification of each compound was secured using retention time and by the selected reaction monitoring of two transitions, one of which was additionally used for quantification. Limits of detection ranged from 0.03 to 0.96 ng L−1 and were up to two orders of magnitude lower than those of previously published methods. The method was validated using spiked samples prepared from tap, river and sea water as well as wastewater effluents, collected from the North of Scotland. Analysis of wastewater effluents revealed the presence of mefenamic acid, ibuprofen, erythromycin, diclofenac and trimethoprim. None of the selected pharmaceuticals were detected in river, tap or sea water samples.  相似文献   

11.
稻谷副产品中脂肪酸的气相色谱-质谱分析   总被引:1,自引:0,他引:1  
对稻谷副产品脂肪酸的组成和含量进行分析测定. 采用索氏提取法提取了稻谷副产品中的脂肪油, 再进行甲酯化处理, 利用气相色谱-质谱法对其脂肪酸组成及含量进行了分析测定. 结果表明, 从稻糠、稻叶、稻秆中鉴定出的脂肪酸分别占其总检出量的96.72%、 71.77%和92.63%, 不饱和脂肪酸含量分别为72.88%、 45.26%和66.96%.  相似文献   

12.
采用正交试验优化的QuEChERS方法处理样品,建立了牛奶中包括前体药物和代谢物在内12种苯并咪唑类(BZs)兽药残留的高效液相色谱-串联质谱检测方法.方法在1~500μg/kg范围内线性良好,相关系数为0.9980~0.9996,平均回收率72.4%~108.3%,RSD为1.4%~9.7%,检出限低于0.5μg/k...  相似文献   

13.
The bioequivalence of two Florfenicol (FF) products in pigs was evaluated. A 2?×?2 crossover trial with a 14 days wash-out period was performed. The pigs were orally administered in a single dose (2?mg/kg b.w of FF). Serum samples were analyzed using a liquid chromatography-tandem mass spectrometry method. The limit of quantification was 0.1?ng/mL, and the calibration range was 1.0–100.0?ng/mL. Furthermore, intraday and interday were 5.43–9.09% and 6.23–9.68%, respectively. The areas under the curve (AUC0–48) for the test product B of FF and reference product A were 7289.61?±?1750.44 and 6545.01?±?2766.25?h?×?ng/mL, respectively. The highest concentrations of FF in the serum (Cmax) were 726.05?±?211.77 and 641.97?±?117.94?ng/mL. The mean retention times (MRT) was 7.91?±?1.98 and 7.76?±?2.89?h while the half-lives (T1/2) were 4.07?±?1.71 and 4.99?±?3.30?h. From the analysis of variance results, the p values of Cmax and AUC0–∞ for the 90% confidence interval were 0.492 and 0.320 (p?>?0.05), respectively. A comparison between the test product and the reference product showed no significant difference. Both products showed bioequivalence after being administered in pigs.  相似文献   

14.
章涛  孙红文 《色谱》2010,28(5):498-502
全氟化合物是一种新型持久性有机污染物,污水处理厂是其一个主要污染来源。目前还没有建立起一种统一的污泥样品中全氟化合物的分析方法。本文报道了一种基于液相萃取和高效液相色谱-串联质谱联用技术测定污泥中的7种全氟烷基羧酸及其2种不饱和氟调酸前体物、2种全氟烷基磺酸及其5种磺酰胺衍生物前体物的方法。实验对萃取剂(甲醇)的pH值、超声萃取温度与时间、洗脱剂体积进行了优化,确定了中性溶剂、40℃下超声萃取10min,Envicarbon柱净化的前处理方法,并成功地应用于实际污泥样品中全氟化合物的测定。方法的回收率为74%~141%(不饱和氟调酸除外),线性范围为0.1~20μg/L(羧酸系列)及0.25~50μg/L(磺酸系列)内线性关系良好(r20.99),定量限为0.6~30μg/kg(干重)。内标物质的使用可有效消除环境基质引起的仪器离子抑制现象,使定量更加准确。  相似文献   

15.
建立了固相萃取-高效液相色谱-串联质谱(HPLC-MS/MS)同时检测人体尿液中N-乙酰基-S-(3,4-二羟基丁基)-L-半胱氨酸(DHBMA)、N-乙酰基-S-(3-羟基丙基)半胱氨酸(3-HPMA)、N-乙酰基-S-(2-氰乙基)-L-2-氨基-3-巯基羧酸(CEMA)和苯巯基尿酸(SPMA)的检测方法。冰冻的人体24 h尿液在室温下解冻,混合均匀后离心过滤,经C18固相萃取小柱净化富集后在多反应监测模式下采用HPLC-MS/MS进行定量分析。在3个添加水平下,尿液中DHBMA、3-HPMA、CEMA和SPMA的加标回收率分别为105.6%~124.4%、102.7%~106.5%、103.2%~103.9%和101.7%~104.3%,相对标准偏差为2.6%~7.7%。以不低于3倍的信噪比估算DHBMA、3-HPMA、CEMA和SPMA的检出限分别为0.062、0.031、0.020和0.003 μg/L。应用该方法检测了37例吸烟和非吸烟者的24 h尿液样本,结果发现吸烟者尿液中3-HPMA、SPMA和CEMA的平均含量比非吸烟者高3到6倍。  相似文献   

16.
高效液相色谱-串联质谱法测定食品中曲酸   总被引:2,自引:0,他引:2  
黄娟  刘艳  丁涛  张晓燕  陈惠兰  沈崇钰  吴斌  牛雯 《色谱》2012,30(6):578-583
建立了食品中新型防腐剂曲酸的高效液相色谱-串联质谱的定量测定方法。动物禽肉、鱼虾甲壳类、酱菜类、水果蔬菜、面制品等固体样品经乙腈提取;酱及酱油、醋、酒、饮料、糖浆等液体样品经水稀释,乙酸锌和亚铁氰化钾沉淀蛋白;以C18柱为分离柱,流动相为乙腈和5 mmol/L乙酸铵甲酸溶液,采用电喷雾串联四极杆质谱进行检测。选择1个母离子和2个子离子进行选择反应监测,以13C6-曲酸作为内标,选择信号最强的子离子进行定量测定。固体类基质中的定量限(按信噪比(S/N)大于10计)为0.1 mg/kg;液体类基质中的定量限为2.5 mg/kg。在0.1~2.0 mg/L范围内呈现良好的线性关系,相关系数r>0.99。各种基质在3个添加水平的平均回收率在72.6%~114%之间,相对标准偏差均小于11.4%。本方法简单实用,准确可靠,适用范围包括了食品中可能使用曲酸这种食品添加剂的大部分基质,可以满足进出口食品中曲酸的定性和定量要求。  相似文献   

17.
何嘉雯  温家欣  赖宇红  刘亚雄  曹雅静  陈俏 《色谱》2019,37(12):1331-1336
建立了高效液相色谱-串联质谱法测定酵素食品中新型减肥类非法添加物匹可硫酸钠的分析方法。针对现有方法不适用的果冻、软糖型样品,开发了新的前处理方法。样品经水提取、聚酰胺净化,使用Thermo Accucore RP-MS色谱柱(100 mm×2.1 mm,2.6 μm),以乙腈-10 mmol/L乙酸铵(15:85,v/v)等度洗脱,流速0.3 mL/min,柱温35℃,多反应监测(MRM)模式下质谱检测,外标法定量。结果表明,匹可硫酸钠在5~500 μg/L范围内线性关系良好,相关系数(r)为0.9999,方法检出限为0.05 mg/kg。匹可硫酸钠在各基质样品中的加标回收率为89.2%~111.8%,相对标准偏差为2.5%~10.4%。按上述方法检测152批次酵素食品,检出阳性样品58批次,检出率为38.2%。该法准确、灵敏,可用于酵素食品中匹可硫酸钠的测定。  相似文献   

18.
A new method for determination of fatty acid amides in polyethylene packaging film was developed using gas chromatography/mass spectrometry (GC/MS). Liquid extraction, Soxhlet extraction ultrasonic-assisted extraction and pressurized solvent extraction (PSE) methods were compared and the results showed that pressurized solvent extraction was the best for extracting these compounds. After extraction, solvent was blown by nitrogen and a trifluoroethyl derivation step was carried out. The derivative compounds were identified and quantified by GC/MS using an HP-Innowax column. The retention times were 6.20 min for derivative hexadecanoamide, 8.56 min for derivative octadecanamide, 8.84 min for derivative oleamide and 13.68 min for derivative erucamide, respectively. The detection limits were 61.0 ng g−1, 74.0 ng g−1, 103.0 ng g−1, and 105.0 ng g−1, respectively, and the linearity were good. The proposed method was applied satisfactorily to determine these chemicals in different types of polyethylene samples.  相似文献   

19.
建立了分析测定水环境中十氯酮的液相色谱-串联质谱法。水样经液液萃取、净化后,采用Eclipse plus C18柱(100 mm×2.1 mm,3.5 μm)分离,乙腈和水为流动相进行梯度洗脱,在电喷雾负离子多反应监测模式下进行检测,同位素内标法定量。结果表明:采用液相色谱-质谱联用技术,证实了十氯酮在甲醇中以半缩醛的形式存在,而在丙酮/乙腈中以偕二醇的形式存在。由于十氯酮极性较强,在净化时难以洗脱,并且不耐酸,所以不能与其他有机氯农药一起分析。十氯酮在5~100 μg/L范围有良好的线性关系,相关系数r2=0.999,检出限及定量限分别为0.70 ng/L和2.8 ng/L;在5、40和100 ng/L 3个浓度添加水平的平均回收率为95.1%~98.9%,相对标准偏差为3.85%~4.72%。本方法具有良好的灵敏度、回收率和重现性,适用于水环境中十氯酮的测定。  相似文献   

20.
孙春艳  纪颖鹤  秦昆明  高珣  赵龙山 《色谱》2019,37(12):1297-1304
建立了一种同时测定吉非替尼中4种基因毒性杂质3-氯-4-氟苯胺、3,4-二氟苯胺、3-氟-4-氯苯胺和3,4-二氯苯胺的高效液相色谱-串联质谱(HPLC-MS/MS)方法。用Inertsil ODS-3柱(100 mm×3.0 mm,3μm)为色谱柱,以0.1%(体积分数,下同)甲酸水溶液-0.1%甲酸乙腈溶液为流动相,在电喷雾正离子模式下进行测定。该方法在特异性、线性、精密度、准确性、稳定性和耐用性方面得到了验证。4种基因毒性杂质在0.6~96.0μg/L范围内与峰面积呈良好线性关系。检测限和定量限分别为0.2~2.0μg/L和0.6~6.0μg/L。所有杂质的回收率为91.0%~98.5%。检测后,在批号16052301和R16052501-1样品中仅检测到3-氯-4-氟苯胺,但低于杂质限度(6 mg/L)。该方法简便可靠,可用于吉非替尼中4种基因毒性杂质的测定,并为质量控制提供参考。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号