首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A novel photonic suspension array was developed for multiplex immunoassay. The carries of this array were silica colloidal crystal beads (SCCBs). The codes of these carriers are the characteristic reflection peak originated from their structural periodicity, and therefore they do not suffer from fading, bleaching, quenching, and chemical instability. In addition, because no dyes or materials related with fluorescence are included, the fluorescence background of SCCBs is very low. With a sandwich format, the proposed suspension array was used for simultaneous multiplex detection of tumor markers in one test tube. The results showed that the four tumor markers, α-fetoprotein (AFP), carcinoembryonic antigen (CEA), carcinoma antigen 125 (CA 125) and carcinoma antigen 19-9 (CA 19-9) could be assayed in the ranges of 1.0-500 ng mL−1, 1.0-500 ng mL−1, 1.0-500 U mL−1 and 3.0-500 U mL−1 with limits of detection of 0.68 ng mL−1, 0.95 ng mL−1, 0.99 U mL−1 and 2.30 U mL−1 at 3σ, respectively. The proposed array showed acceptable accuracy, detection reproducibility, storage stability and the results obtained were in acceptable agreement with those from parallel single-analyte test of practical clinical sera. This technique provides a new strategy for low cost, automated, and simultaneous multiplex immunoassay.  相似文献   

2.
A new suspension array built upon laboratory-prepared functional fluorescence-encoded polystyrene beads (FFPBs) was developed for multiplex immunodetection of tumor markers. The FFPBs were synthesized by copolymerizing rhodamine 6G (R6G) and carboxyl function groups on the surface of the seed beads forming a core-shell structure. The fabrication process was facile and the encoding fluorescence intensity of the beads can be precisely controlled by adjusting the quantity of R6G. In present work, we demonstrated that the quantity variation of impregnated R6G had negligible effect on the coupling efficiency of biomolecules onto the surface of the FFPBs. The R6G encoding fluorescence remained good monodispersity upon capture probe coupling and immunocomplex formation. No fluorescence resonance energy transfer was observed between the R6G doped in the bead shell and fluorophore used for antibody labeling. Under the optimal conditions, the proposed suspension array allowed simultaneous detection of α-fetoprotein, carcinoembryonic antigen, and prostate specific antigen in the ranges of 0.07-500 ng mL−1, 1-2000 ng mL−1, and 0.5-500 ng mL−1, respectively, with detection limits of 0.0626 ng mL−1, 0.554 ng mL−1, and 0.250 ng mL−1. Test on clinical serum samples demonstrated that the results obtained with suspension array were in good agreement with those of the reference electrochemiluminescence immunoassay method. We conclude that the laboratory-made FFPBs are sufficient as the microcarrier for the construction of suspension array in clinical diagnosis.  相似文献   

3.
Biosensors for environmental pollutants and food contaminants   总被引:4,自引:0,他引:4  
This review article provides an overview of the most recent literature on biosensors for environmental pollutants and food contaminants. Due to the large number of publications, only papers published between 2000 and January 2003 were considered. Also, while not all of the published literature could be reviewed here, over 200 references are cited to provide a good overview of research undertaken in the last two years. Older publications are covered by a number of earlier review articles. This article provides an introduction into the field including specific consideration of the application areas, describes the typical biosensor assay format used, and is subsequently structured according to the biorecognition elements used (i.e., nucleic acids, enzymes, whole cells, tissue and whole organisms, antibodies and receptors, and biomimetic materials). In addition, a section on microbiosensing systems is provided. Since only very few microbiosensors with applications in environmental and food systems have been published, enabling technology is also covered in this article.Abbreviations BOD biological oxygen demand - cfu colony forming units - DNP dinitrophenol - GFP green fluorescent protein - NASBA nucleic acid sequence-based amplification - PCR polymerase chain reaction - ppt parts per trillion - QCM quartz crystal microbalance - SPR surface plasmon resonance  相似文献   

4.
This work investigates the use of electronic tongues for environmental monitoring. Electronic tongues were based on arrays of potentiometric sensors plus a complex data processing by artificial neural networks and data transmission by radiofrequency. A first application, intended for a system simulating real conditions in surface water, performed a simultaneous monitoring of ammonium, potassium, sodium, chloride, and nitrate ions. The proposed system allowed us to assess the effect of natural biodegradation stages for these species. A second application was used to monitor concentrations of ammonium, potassium, and sodium in the ‘Ignacio Ramírez’ dam (Mexico). The electronic tongue used here allowed us to determine the content of the three cations in real water samples, although a high matrix effect was encountered for sodium determination. The implemented radio transmission worked robustly during all the experiments, thus demonstrating the viability of the proposed systems for automated remote applications.  相似文献   

5.
Biosensors for environmental monitoring A global perspective   总被引:2,自引:0,他引:2  
The intention of this article is to reflect the advances and describe the trends on biosensors for environmental applications. Biosensors are useful analytical tools for environmental monitoring, capable of providing results in real time, simple to use, portable and cost-effective. Some examples of biosensors in advanced stage of development, which have been applied to real samples, as well as of commercial devices, are given. Biosensors designed for measurement of either specific chemicals or their biological effects, such as toxicity biosensors and endocrine effect biosensors, are discussed. This overview also addresses the support provided by public institutions for biosensor research in the USA, Japan and, especially, in Europe. Future prospects of biosensor technology, with special emphasis in the development of new sensing elements, are foreseen.  相似文献   

6.
STEINFELD  Jeffrey I. 《中国化学》1999,17(3):204-211
The ability to monitor a broad range of chemical species in the atmosphere, geosphere, and hydrosphere is a key technology for addressing global environmental issues. This report surveys several high sensitivity spectroscopic techniques for this purpose, including Frequency-Modulation-Enhanced Remote Sensing, In-traCavity Laser Absorption Spectroscopy, Cavity RingDown Spectroscopy, and Raman Spectroscopy.  相似文献   

7.
This article provides an overview of the applications of biosensors in analysis and monitoring of endocrine-disrupting compounds (EDCs) in the environment. Special attention is devoted to the various types of physical-chemical signal transduction elements, biological mechanisms employed as sensing elements and techniques used for immobilisation of the bioreceptor molecules on the transducer surface. Two different classes of biosensors for EDCs are considered: biosensors that measure endocrine-disrupting effects, and biosensors that respond to the presence of a specific substance (or group of substances) based on the specific recognition of a biomolecule. Several examples of them are presented to illustrate the power of the biosensor technology for environmental applications. Future trends in the development of new, more advanced devices are also outlined.  相似文献   

8.
This paper reports the assessment of total arsenic and six arsenic species (As(III), As(V), MMA, DMA, AsBet, AsCol) as contaminants of mussel samples collected around the island of Sardinia and in the Gulf of Venice. The samples were analysed using cation- and anion-exchange HPLC-HG-AFS for speciation and ICP-AES for the total As determination. To ensure the robustness of the routine analytical method, the technique was validated using a candidate reference material, BCR-710, and good agreement was obtained. It was recognised that higher total arsenic concentration in mussels does not necessarily result in higher toxicity of mussel samples.  相似文献   

9.
Traceability is now considered to be a key concept in chemical and biological measurement sciences. While this concept is increasingly used in many areas, it is still prone to misunderstandings with respect to more ‘classical' terms such as e.g. accuracy. Traceability implies that measurement data are linked to stated references through an unbroken chain of comparisons, all with stated uncertainties. What does the word ‘stated references' mean when it is applied to complex environmental analysis? This paper discusses how traceability can be conceived in the context of environmental monitoring, in particular the various stated references (documented standards, reference materials, environmental specimens) to which chemical environmental data may be linked to.  相似文献   

10.
突发环境事件现场应急监测仪器技术现状及展望   总被引:1,自引:0,他引:1  
突发环境事件现场应急监测是环境监测工作的重要组成部分.与常规实验室环境监测分析相比,现场应急监测的时效性要求更高,需要做到对环境污染物的快速定性与半定量分析.本文在分析现场应急监测仪器技术的基本特点基础上,从现场应急监测的环境介质、待监测项目、监测仪器技术分类等方面入手,重点对国内光谱法、色谱/质谱法和电化学法等类别的现场应急监测仪器技术现状进行了总结,最后对现场应急监测仪器技术的未来发展趋势进行了展望.  相似文献   

11.
Personal-care products (PCPs) are organic chemicals widely used in human life daily. Among the most recently studied PCPs, we can find ultraviolet filters, preservatives, antimicrobials, musk fragrances, insect repellents and siloxanes. PCPs are increasingly important emerging organic contaminants due to their presence in environmental waters.We present a review of the most important extraction and chromatographic techniques used to determine PCPs in waters. We also review data regarding the occurrence of these compounds in different kinds of environmental waters and the removal of these compounds in sewage-treatment plants.  相似文献   

12.
Sample preparation frequently is considered the most critical stage of the analytical workflow. It affects the analytical throughput and costs; moreover, it is the primary source of error and possible sample contamination. To increase efficiency, productivity, and reliability, while minimizing costs and environmental impacts, miniaturization and automation of sample preparation are necessary. Nowadays, several types of liquid-phase and solid-phase microextractions are available, as well as different automatization strategies. Thus, this review summarizes recent developments in automated microextractions coupled with liquid chromatography, from 2016 to 2022. Therefore, outstanding technologies and their main outcomes, as well as miniaturization and automation of sample preparation, are critically analyzed. Focus is given to main microextraction automation strategies, such as flow techniques, robotic systems, and column-switching approaches, reviewing their applications to the determination of small organic molecules in biological, environmental, and food/beverage samples.  相似文献   

13.
Fluorescence polarization immunoassay (FPIA) is a homogeneous (without separation) competitive immunoassay method based on the increase in fluorescence polarization (FP) of fluorescent-labeled small antigens when bound by specific antibody. The minimum detectable quantity of FPIAs with fluorescein label (about 0.1 ng analyte) is comparable with chromatography and ELISA methods, although this may be limited by sample matrix interference. Because of its simplicity and speed, FPIA is readily automated and therefore suitable for high-throughput screening (HTS) in a variety of application areas. Systems that involve binding of ligands to receptor proteins are also susceptible to analysis by analogous FP methods employing fluorescent-labeled ligand and HTS applications have been developed, notably for use in candidate drug screening.  相似文献   

14.
Bisphenol A (BPA) is a well-known endocrine-disrupting industrial compound that is found throughout many aspects of our daily life; from the water we drink and the food we eat to the babies’ bottles and children’s plastic toys. Chronic exposure to BPA may result in some severe medical issues which account for the great importance of its monitoring and removal from everyday products. The use of molecularly imprinted polymers (MIPs) for that purpose has acquired a lot of traction in recent decades. MIPs are artificial antibodies with selective recognition cavities for specifically targeted substances. They are created using a variety of synthetic methods and employed in numerous types of sensors to be used in a wide range of applications. In this review, we focus on the different production methods of MIPs and the varied types of electrochemical and optical sensors that employed MIPs to detect and analyze BPA. Finally, the broad variety of applications of MIPs in environmental, foodstuff, and biological samples are thoroughly examined. Future expected trends and prospective developments are also assessed.  相似文献   

15.
16.
We review the state-of-the-art application of nanoparticles (NPs) in electrochemical analysis of environmental pollutants. We summarize methods for preparing NPs and modifying electrode surfaces with NPs. We describe several examples of applications in environmental electrochemical sensors and performance in terms of sensitivity and selectivity for both metal and metal-oxide NPs. We present recent trends in the beneficial use of NPs in constructing electrochemical sensors for environmental monitoring and discuss future challenges.NPs have promising potential to increase competitiveness of electrochemical sensors in environmental monitoring, though research has focused mainly on development of methodology for fabricating new sensors, and the number of studies for optimizing the performance of sensors and the applicability to real samples is still limited.  相似文献   

17.
Progress in the development of a micro-fluidic system for colorimetric monitoring of ammonia in drinking and wastewater is described. The ultimate goal is to have a miniaturised instrument that can produce accurate, reliable measurements, is easy to operate, has minimal power consumption, and can operate autonomously for a year. In this study, the indophenol reaction is incorporated into a simple, reliable analytical micro-fluidic system. Absorbance measurements for the blue ammonia-indophenol complex formed in the micro-fluidic system are shown. A key issue is the limiting stability of hypochlorite, a reagent used in the assay. The effects of hypochlorite concentration and impurities on the stability of hypochlorite are investigated and discussed. Decomposition is shown to be very dependent on the presence of heavy-metal impurities. With low levels of these catalytic metals and careful storage, hypochlorite has been shown to be stable for over a year.  相似文献   

18.
Environmental analysis is a potential key application for chemical sensors owing to their inherent ability to detect analytes on-line and in real time in distributed systems. Operating a chemosensor in a natural environment poses substantial challenges in terms of ruggedness, long-term stability and calibration. This article highlights current trends of achieving both the necessary selectivity and ruggedness: one way is deploying sensor arrays consisting of robust broadband sensors and extracting information via chemometrics. If using only a single sensor is desired, molecularly imprinted polymers offer a straightforward way for designing artificial recognition materials. Molecularly imprinted polymers can be utilized in real-life environments, such as water and air, aiming at detecting analytes ranging from small molecules to entire cells. Figure    相似文献   

19.
This paper reviews the latest developments and analytical applications of chemiluminescence detection coupled to capillary electrophoresis (CE-CL). Different sections considering the most common CL systems have been included, such as the tris(2,2?-bipyridine)ruthenium(II) system, the luminol and acridinium derivative reactions, the peroxyoxalate CL or direct oxidations. Improvements in instrumental designs, new strategies for improving both resolution and sensitivity, and applications in different fields such as clinical, pharmaceutical, environmental and food analysis have been included. This review covers the literature from 2010 to 2015.  相似文献   

20.
Endocrine-disrupting chemicals (EDCs) are capable of interfering with normal hormone homeostasis by acting on several targets and through a wide variety of mechanisms. Unwanted exposure to EDCs can lead to a wide spectrum of adverse health effects, especially when exposure is during critical windows of development. Feed and food are considered to be among the main routes of inadvertent exposure to EDCs, so there is an important need for efficient detection of EDCs in these matrices.We describe in vitro bioassays that can complement current analytical chemistry in order to detect unwanted EDCs and describe their action, emphasizing assays that can measure effects on nuclear receptor signaling or hormone production. We outline both validated and unvalidated in vitro assays currently available in the scientific community for detecting and studying the effects of EDCs, and discuss their possible role in the food-safety context. We conclude by identifying gaps in the current battery of in vitro assays available for EDCs and suggest future possibilities for development and validation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号