首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 928 毫秒
1.
Yang XF  Guo XQ  Zhao YB 《Talanta》2002,58(5):883-890
A flow injection (FI) method with on-line preconcentration using a mini-column loaded with 8-hydroxyquinoline immobilized on controlled pore glass (CPG-8HQ) is described for the determination of trace metals by ion chromatography (IC) with pyridine-2-6-dicarboxylic acid (PDCA) as the eluent. Copper, cadmium, lead, zinc, nickel and iron were determined at ppb level after post-column derivatization with 4-(2-pyridylazo)-resorcinol (PAR). The detection limits (3sigma) for the FI/IC system were 8.27, 0.89, 0.09, 0.06, 0.09 and 0.07 g l(-1) for Pb(2+), Cd(2+), Cu(2+) Ni(2+), Zn(2+) and Fe(3+), respectively, using 5 ml sample volume. The method was applied to the analysis of Malaysian natural waters.  相似文献   

2.
The application of sulfur-nanoparticle-loaded alumina as an efficient adsorbent for the solid-phase extraction (SPE) and determination of trace amounts of Cd, Cu, Zn, and Pb ions was investigated in marine samples using flame atomic absorption spectrometry (FAAS). The nanometer-sized sulfur particles were synthesized in situ, physically loaded onto alumina microparticles, and the parameters influencing the preconcentration of the analytes, such as the pH, solution flow rate and volume, eluent solution, and interfering ions, were examined. The results showed that the optimal conditions for quantitative recovery of the metal ions by adsorption and elution on the sulfur nanoparticles (SNPs) was achieved by employing a flow rate of 15 mL min(-1), a pH of 8.5 for the sample solutions, and an eluent composed of 3.0 mol L(-1) HNO(3) in methanol. The detection limits of this method for Cd, Zn, Cu, and Pb ions were 0.30, 0.21, 0.24, and 0.63 μg L(-1) (n=10), respectively. Application of the proposed method to the analysis of fish certified reference material (DORM-3) produced results that were in good agreement with the certified values. The proposed method was also successfully applied to the determination of analytes in marine samples, including seawater, fish, and oysters.  相似文献   

3.
A simple method for the elements preconcentration on thin-layer paraffin-treated cellulose filters was proposed. It was found that pyrrolydinedithiocarbamates of As(III), Bi, Cd, Co, Cu, Fe(III), Ni, Pb, Se(IV), V(V) and Zn obtained after mixing of sample (3-5 ml min−1) and reagent (0.7-1.0 ml min−1) streams were quantitatively recovered from 100 ml sample. The sample acidity was adjusted to pH 4.8-5.2 for preconcentration of Cd, Co, Cu, Fe(III), Ni, Pb, V(V) and Zn, and to 2 M HCl for preconcentration of As, Bi and Se. The optimum reagent concentration was found to be 0.1%. The elements were determined on the filters by X-ray fluorescence spectrometry. The detection limits achieved were 0.1-4.0 μg of element on the filter. Relative standard deviation (R.S.D.) was not higher than 0.08 while determining 5-50 μg of elements on filter. Accuracy and precision of the technique proposed were evaluated by the analysis of spiked natural samples.  相似文献   

4.
Fast-flow spherical homogeneous agarose beads were prepared by an emulsification method, and were cross-linked and activated by repeated treatment with allylbromide and bromine/water, followed by alkali. Bis(2-aminopyridyl)dioxime (APD) was synthesized by the reaction of 2-aminopyridine, and dichloroglyoxime and characterized by melting-point as well as IR, 1HNMR, 13CNMR and MS spectroscopies. APD was chemically linked to activated agarose beads to be employed for the column preconcentration of metal ions. Capacity measurements for eight metal ions indicated a high selectivity of the adsorbent towards Cu2+ with a capacity of 25.7 micromol per ml packed adsorbent. A factorial design was used for optimization of the effects of 5 different variables on the recovery of Cu2+. Under the optimized conditions, Cu2+ was quantitatively accumulated on a 0.25 ml packed column of the adsorbent in the pH range of 4 to 6, and simply eluted with 2 ml of a 1 mol 1(-1) hydrochloric acid solution. The column could tolerate salt concentrations up to 0.5 mol 1(-1), sample flow rates up to 15 ml min(-1), and sample volumes beyond 1000 ml. Matrix ions of Na+, Mg2+ and Ca2+ and potentially interfering ions of Ni2+, Cd2+, Zn2+, Fe3+ and Co2+ with relatively high concentrations did not show any significant effect on the analyte's signal. Preconcentration factors up to 500 and a detection limit of 0.16 microg 1(-1) were obtained for the determination of the analyte by flame AAS. Application of the method to the determination of natural and spiked copper in river water and seawater samples resulted in quantitative recoveries.  相似文献   

5.
The silica gel with 1-(2-thiasolylazo)-2-naphthol adsorbed was obtained. The adsorption of Cu(II) and Zn(II) from an aqueous solution onto loaded silica gel was studied. The capabilities of 1-(2-thiasolylazo)-2-naphthol immobilized for Cu(II) and Zn(II) preconcentration, visual and diffusion reflectance spectroscopic detection was evaluated. The detection limits were 10 and 15 microg.l(-1), respectively. Visual test scales for metal ions determination in the range 0.65-13 microg per sample were worked out. The developed methods were applied to Cu(II) and Zn(II) determination in natural and tap water. The obtained results agreed well with the reported value.  相似文献   

6.
Willie SN  Tekgul H  Sturgeon RE 《Talanta》1998,47(2):439-445
A rapid and simple on-line method is described for the preconcentration of Mn, Co, Ni, Cu, Zn, Cd and Pb from sea water using 8-hydroxyquinoline immobilized onto silicone tubing (Sil-8-HQ) via the Mannich reaction. Recoveries between 35 and 95% and limits of detection in the ppt range were obtained using a 2 m long Sil-8-HQ tube with a sample flow rate of 1.0 ml min(-1). A tube could be subjected to sample loading and elution cycles over 200 times. The capacity was 1.5 and 1.3 mug cm(-2) for Cu and Mn, respectively. Cu, Cd, Co, Pb, Mn, Zn and Ni were determined in coastal and open ocean seawater using flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS). Good agreement with certified values for the certified reference materials NASS-4 and CASS-3 was demonstrated when quantitation was undertaken by the method of additions.  相似文献   

7.
A sol-gel zirconia coating was developed for the preconcentration/separation of trace Cr, Cu, Cd and Pb by capillary microextraction, and the adsorbed analytes were on-line eluted for detection using inductively coupled plasma mass spectrometry (ICP-MS). By immobilizing sol-gel zirconia on the inner surface of a fused-silica capillary, the sol-gel zirconia coating was simply prepared. Its adsorption properties, stability and the factors affecting the adsorption behaviors of Cr, Cu, Cd and Pb were investigated in detail. In the pH range from 7.8 to 10, the zirconia-coated capillary (35 cm x 0.15 mm) is selective towards Cr, Cu, Cd and Pb, and the analyzed ions could be desorbed quantitatively with 0.2 mL of 0.5 mol/L HNO(3) at a rate of 0.2 mL/min. With a consumption of 1.25 mL sample solution, an enrichment factor of 6.25, and detection limits (3sigma) of 9.9 pg/mL Cr, 17.9 pg/mL Cu, 4.5 pg/mL Cd and 3.7 pg/mL Pb were obtained. The precisions for nine replicate measurements of 1 ng/mL Cr, Cu, Cd and Pb were 4.9% Cr, 2.2% Cu, 2.0% Cd and 3.2% Pb (RSD), respectively. The proposed procedure has been applied to the determination of Cr, Cu, Cd and Pb in human urine, which was subjected to microwave-assisted digestion prior to analysis, and the recoveries for these elements were 89.2-101.8%. In order to validate the developed procedure, a NIES No.10-a Rice Flour-Unpolished certified reference material and a BCR No. 184 Bovine Muscle certified reference material were analyzed, and the results are in good agreement with the certified values.  相似文献   

8.
1,2-Bis(salicylidenamino)ethane loaded onto sodium dodecyl sulfate-coated alumina was used as a new chelating sorbent for the preconcentration of traces of Pb(Ⅱ) and Cu(Ⅱ) prior to atomic absorption spectrometric determination. The influence of pH, flow rates of sample and eluent solutions, and foreign ions on the recovery of Pb(Ⅱ) and Cu(Ⅱ) by this sorbent has been studied. The retained ions were eluted with 4 mol·L nitric acid and determined by electrothermal atomic absorption spectrometry (ETAAS). The data of limit of detection (3σ) for Pb(Ⅱ) and Cu(Ⅱ) were found to be 8.57 and 2.69 ng·L^-1 respectively, while the enrichment factor for both ions was 100. The proposed method was successfully applied to determination of lead and copper in different water samples.  相似文献   

9.
《Analytical letters》2012,45(10):1991-2004
ABSTRACT

A method was developed for the preconcentration of copper, nickel and cadmium in water samples, prior to their determination by FAAS, using the Zn-piperazinedithiocarbamate complex (ZnPDC) loaded on activated carbon. In this method, Cu, Ni and Cd in liquid phase quantitatively replaced zinc on a ZnPDC-activated carbon solid phase. Afterwards, the metals on the solid phase were easily eluted by Hg (II) solution into aqueous phase, and were measured by FAAS. The optimum experimental parameters such as pH, sample volume, and effect of matrix ions for the preconcentration of the metals were investigated. The range of linearity 0-6, 0-5, 0-3 μgml?1, correlation coefficient 0.998, 0.996, 0.999, detection limits 15.7, 23.5, 11.8 ngml?1 and determination limits 136, 179, 98 ngml?1 in final Hg(II) solution were obtained for Cu, Ni and Cd, respectively. The proposed method has been employed for the determination of Cu, Ni and Cd in various standard metal alloys and natural water samples.  相似文献   

10.
A rapid separation and preconcentration method was developed for the determination of trace metals Cu, Zn, Cd, and Pb in seawater using a minicolumn packed with thiol cotton fiber (TCF) coupled with inductively coupled plasma mass spectrometry (ICP-MS). Preconcentration parameters, such as seawater sample volume and flow rate and eluent hydrochloric acid concentration, volume and flow rate, were optimized. Under the optimized conditions, trace metals Cu, Zn, Cd, and Pb in seawater can be determined with no interference from saline matrices. When a sample volume of 1500 ml and a sample flow rate of 15 ml min(-1) were used, the preconcentration factor of 1500 and RSD value of <7% at ng ml(-1) were achieved. The accuracy of the recommended method was verified by the analysis of certified reference materials.  相似文献   

11.
A sensitive and simple method for the simultaneous preconcentration of nutritionally important minerals in real samples has been reported. The method is based on the adsorption of Cu2+, Ni2+, Co2+ and Pb2+ on 4-propyl-2-thiouracil (PUT) loaded on activated carbon. The metals on the complexes are eluted using 5 mL 3 M HNO3 in acetone. The influences of the analytical parameters including pH and sample volume were investigated. The effects of matrix ions on the retentions of the analytes were also examined. The recoveries of analytes were generally higher than 95%. The detection limits for Cu2+, Ni2+, Co2+ and Pb2+ were 1.6, 1.3, 1.2, 2.3 ng ml(-1), respectively. The method has been successfully applied for these metals content evaluation in some real samples including natural water samples.  相似文献   

12.
In this work, an ordered mesoporous titania film was introduced to coat a capillary by means of sol-gel technique. Sol-gel titania coating was developed for the preconcentration/separation of trace V, Cr and Cu by capillary microextraction (CME), and the adsorbed analytes were eluted for electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) detection. By immobilizing sol-gel titania on the inner surface of a fused-silica microextraction capillary, the sol-gel titania coating was prepared easily. Its adsorption properties, stability and the factors affecting the adsorption behaviors of V, Cr and Cu were investigated in detail. At pH range of 7 to 9, the titania-coated capillary (50 cm x 0.25 mm) is selective towards V, Cr and Cu, and the target analytes could be desorbed quantitatively with 50 microl of 1.0 mol l(-1) HNO3 at the rate of 0.05 ml min(-1). With a consumption of 2 ml sample solution, an enrichment factor of 33.3, and a detection limit (3 s) of 1.1 pg ml(-1) (10.5 fg) for V; 3.3 pg ml(-1) (33.0 fg) for Cr and 6.3 pg ml(-1) (63.1 fg) for Cu respectively were obtained. The precisions Relative Standard Deviations (RSDs) for nine replicate measurements of 1 ng ml(-1) V, Cr and Cu were 3.4, 5.1 and 6.4%, respectively. The proposed method has been applied to the determination of V, Cr and Cu in human urine and lake water, and the recoveries for these elements were 89.2 approximately 105%. The developed method was also applied to the determination of the target elements in NIES No. 10-a (rice flour-unpolished) and NIES No. 9 (sargasso) certified reference materials, and the results found are in good agreement with the certified values.  相似文献   

13.
A rapid flotation method for separation and enrichment of ultra trace amounts of copper(II), cadmium(II), nickel(II) and cobalt(II) ions from water samples is established. At pH 6.5 and with sodium dodecylsulfate used as a foaming reagent, Cu2+, Cd2+, Ni2+ and Co2+ were separated simultaneously with 2-aminocyclopentene-1-dithiocarboxylic acid (ACDA) added to 1 l of aqueous solution. The proposed procedure of preconcentration is applied prior to the determination of these four analytes using inductivity coupled plasma-atomic emission spectrometry (ICP-AES). The effects of pH, concentration of ACDA, applicability of different surfactants and foreign ions on the separation efficiency were investigated. The preconcentration factor of the method is 1000 and the detection limits of copper(II), cadmium(II), nickel(II) and cobalt(II) ions are 0.078, 0.075, 0.072 and 0.080 ng ml(-1), respectively.  相似文献   

14.
A simple, rapid, sensitive and environmentally friendly separation and preconcentration procedure, based on the carrier element free coprecipitation (CEFC) of Cu(II) and Cd(II) ions by using an organic coprecipitant, 2-{[4-(4-fluorophenyl)-5-sulphanyl-4H-1,2,4-triazol-3-yl]methyl}-4-{[(4-fluorophenyl) methylene]amino}-5-(4-methylphenyl)-2,4-dihydro-3H-1,2,4-triazol-3-one (MEFMAT) was developed. The analyte ions were determined by flame atomic absorption spectrometric (FAAS) determinations. The optimum conditions for the coprecipitation process were investigated on several commonly tested experimental parameters such as pH of the solution, amount of MEFMAT, sample volume, standing time, centrifugation rate and time. The influences of some anions, cations and transition metals on the recoveries of analyte ions were also investigated, and no considerable interference was observed. The preconcentration factor was found to be 50. The detection limits for Cu(II) and Cd(II) ions based on the three times the standard deviation of the blanks (N:10) were found to be 1.49 and 0.45 μg L− 1, respectively. The relative standard deviations were found to be lower than 3.5% for both analyte ions. The method was validated by analyzing two certified reference materials (CRM-TMDW-500 Drinking Water and CRM-SA-C Sandy Soil C) and spike tests. The procedure was successfully applied to sea water and stream water as liquid samples and tobacco, hazelnut and black tea as solid samples.  相似文献   

15.
The present work displays capillary liquid chromatographic column switching methodology tailored for determination of benzo[a]pyrene tetrol isomers in biological matrices using on-line fluorescence and micro-electrospray ionization mass spectrometric detection. A well-established off-line crude solid phase extraction procedure was used in order to make the method compatible with several biological matrices. The solid phase extraction eluates were evaporated to dryness, redissolved in 1.0 ml methanol:water (10:90, v/v), loaded onto a 0.32 mm I.D. x 40 mm 5 microm Kromasil C(18) pre-column for analyte enrichment and back-flushed elution onto a 0.30 mm I.D. x 150 mm 3.5 microm Kromasil C(18) analytical column. The samples were loaded with a flow rate of 50 microl min(-1) and the tetrols were separated at a flow rate of 4 microl min(-1) with an acetonitrile:10 mM ammonium acetate gradient from 10 to 90%. A sample loading flow rate up to 50 microl min(-1) was allowed. The fluorescence excitation and emission were set to 342 and 385 nm, respectively, while mass spectrometric detection of the benzo[a]pyrene tetrols was obtained by monitoring their [M - H](-) molecular ions at m/z 319. The method was validated over the concentration range 0.1-50 ng ml(-1) benzo[a]pyrene tetrols in a cell culture medium with 100 microl injection volume, fluorescence detection and the first eluting tetrol isomer as model compound, resulting in a correlation coefficient of 0.993. The within-assay (n= 6) and between-assay (n= 6) precisions were determined to 2.6-8.6% and 3.8-9.6%, respectively, and the recoveries were determined to 97.9-102.4% within the investigated concentration range. The mass limit of detection (by fluorescence) was 3 pg for all the tetrol isomers, corresponding to a concentration limit of detection of 30 pg ml(-1) cell culture medium. The corresponding mass spectrometric mass limits of detection were 4-10 pg, corresponding to concentration limits of detection of 40-100 pg ml(-1) cell culture medium.  相似文献   

16.
Narin I  Soylak M 《Talanta》2003,60(1):215-221
1-(2-pyridylazo) 2-naphtol (PAN) impregnated Ambersorb 563 resin was used as solid phase extractor of copper, nickel, cadmium, lead, chromium and cobalt ions in aqueous solutions prior to their atomic absorption spectrometric determinations. The parameters including pH, sample volume, matrix effects were also investigated. The relative standard deviation (R.S.D.) of the combined method of sample treatment, preconcentration and determination with atomic absorption spectrometry is generally lower than 10%. The limit of detection was between 0.21 and 1.4 μg l−1. The results were used for preconcentration of analyte ions from natural water samples. The method was also applied to a stream sediment standard reference material (GBW7309) for the determination of Cu, Ni, Cd, Pb, Cr and Co.  相似文献   

17.
The determination of trace metals (Cd, Co, Cu, Fe, Ni and Pb) at concentrations found in fresh and sea waters is described. The metals are extracted as diethyldithiocarbamates from 500-ml samples into carbon tetrachloride, the extracts are evaporated to dryness and the residues are mineralized with 0.1 ml of concentrated nitric acid. This solution is used for graphite-furnace atomic absorption spectrometry after appropriate dilution. The detection limits are 10 pg Cd, 150 pg Co, 125 pg Cu, 100 pg Fe, 250 pg Ni and 100 pg Pb. The extraction/mineralization method is almost free from interferences, e.g., from trace elements at 500-fold and Na, K, Ca and Mg at million-fold amounts. The procedure is successfully applied to the determination of the above metals in deionized water, and river and sea waters.  相似文献   

18.
Narin I  Soylak M  Elçi L  Doğan M 《Talanta》2000,52(6):1041-1046
A simple preconcentration method is described for the determination of Cu, Mn, Co, Cd, Pb, Ni and Cr in water samples by flame AAS. Trace metal ions in water were sorbed as pyrocatechol violet complexes on activated carbon column at the pH range of 4–8, then eluted with 1 M HNO3 in acetone. The effect of major cations and anions of the natural water samples on the sorption of metal ions has been also investigated. The concentration of the metal ions detected after preconcentration was in agreement with the added amount. The present method was found to be applicable to the preconcentration of Cu, Mn, Co, Cd, Pb, Ni and Cr in natural water samples with good results such as R.S.D. from 3 to 8% (N=10) and detection limits under 70 ng l−1.  相似文献   

19.
A column, solid-phase extraction (SPE), preconcentration method was developed for determination of Bi, Cd, Co, Cu, Fe, Ni and Pb ions in drinking water, sea water and sediment samples by flame atomic absorption spectrometry. The procedure is based on retention of analytes in the form of pyrrolidine dithiocarbamate complexes on a short column of Chromosorb-102 resin from buffered sample solution and then their elution from the resin column with acetone. Several parameters, such as pH of the sample solution, amount of Chromosorb-102 resin, amount of ligand, volume of sample and eluent, type of eluent, flow rates of sample and eluent, governing the efficiency and throughput of the method were evaluated. The effects of divers ions on the preconcentration were also investigated. The recoveries were >95%. The developed method was applied to the determination of trace metal ions in drinking water, sea water and sediment samples, with satisfactory results. The 3σ detection limits for Cd, Cu, Fe, Ni and Pb and were found to be as 0.10, 0.44, 11, 3.6, and 10 μg l−1, respectively. The relative standard deviation of the determination was <10%. The procedure was validated by the analysis of a standard reference material sediment (GBW 07309) and by use of a method based on coprecipitation.  相似文献   

20.
Uzun A  Soylak M  Elçi L 《Talanta》2001,54(1):197-202
A method for the preconcentration of Cu, Fe, Pb, Ni, Cd and Bi as their diethyldithiocarbamate chelates was proposed using a column filled with Amberlite XAD-4 resin. The retained analytes on the resin were recovered with a small volume of acetone. The metal ions in the effluent were determined by a flame atomic absorption spectrometer. Different factors including pH of sample solution, sample volume, amount of XAD-4 resin, amount of ligand, eluent volume and matrix effects for preconcentration were examined. The recoveries for the analytes under the optimum working conditions were higher than 95%. The relative standard deviations of the determinations were below 9%. The limits of detection (3 s, n=20) for analytes were found to be between 4 and 23 mug l(-1). The proposed method was applied to the analysis of some waste waters from the organized industrial region of Kayseri.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号