首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
Six commercially available analytical (4.1 or 4.6 mm i.d.) columns were evaluated under temperature-programmed high-temperature liquid chromatography (HTLC) conditions to access their stability and performance at extreme temperatures. Seven components consisting of acidic, basic and neutral compounds were analyzed under temperature-programmed conditions and solvent gradient conditions using three different mobile phase compositions (acidic, basic and neutral). Each column was checked with a two-component test mix at various stages of the evaluation to look for signs of stationary phase collapse. Three zirconia based stationary phases studied exhibited column bleed under temperature-programmed conditions. The other three columns, a polydentate silica column, a polystyrene-divinylbenzene (PS-DVB) polymeric column, and a graphitic carbon column performed well with no evidence of stationary phase degradation. The R.S.D. for the retention times and efficiencies were less than 10% for most conditions, and not more than 15% during the course of the evaluation for each column. The polydentate silica stationary phase was temperature programmed to 100 degrees C, the PS-DVB stationary phase was temperature programmed up to 150 degrees C, and the graphitic carbon column was used with temperature programming up to 200 degrees C. Comparable peak capacities and similar retention behaviors were observed under solvent gradient and temperature-programmed conditions. Temperature programming with dynamic mobile phase preheating can replace solvent gradient analysis without a loss of peak capacity when used with 4.1 or 4.6 mm columns.  相似文献   

2.
Column temperature plays two important roles in reversed-phase high-performance liquid chromatography (RP-HPLC): control of retention (k) and control of selectivity (a). While changes in retention as a function of temperature are ubiquitous, selectivity changes for any given solute pair are more pronounced for ionized samples and samples with more polar substituents. With many samples, column temperature can be selected in a manner that optimizes resolution. The selectivity effects observed for temperature changes in RP-HPLC generally are complementary to those observed for mobile phase strength changes, so it is often possible to improve resolution by simultaneous optimization of temperature and mobile phase percent organic or gradient steepness. Computer simulation is a powerful tool for such optimization experiments. This paper reviews the influence of temperature on chromatographic selectivity for RP-HPLC.  相似文献   

3.
Eleven cyanopropyl ("cyano") columns were characterized by means of a relationship developed originally for alkyl-silica columns. Compared to type-B alkyl-silica columns (i.e., made from pure silica), cyano columns are much less hydrophobic (smaller H), less sterically restricted (smaller S*), and have lower hydrogen-bond acidity (smaller A). Because sample retention is generally much weaker on cyano versus other columns (e.g., C8, C18), a change to a cyano column usually requires a significantly weaker mobile phase in order to maintain comparable values of k for both columns. For this reason, practical comparisons of selectivity between cyano and other columns (i.e., involving different mobile phases for each column) must take into account possible changes in separation due to the change in mobile phase, as well as change in the column.  相似文献   

4.
The dual gradient column, in which both the chemical property of the stationary phase and the flow velocity in the mobile phase are heterogeneous longitudinally along the column, is developed to obtain the mobile phase gradient-like elution in an isocratic condition. Here, the step-wise dual gradient columns were prepared by connecting an inlet column (I.D. 50 microm, packed with ODS) serially to an outlet column (I.D. 100-200 microm, packed with the mixture of ODS and C1 [9:1]). The retention behavior of alkylbenzenes was able to be controlled in the dual gradient column depending on the variation in the flow velocity. Moreover, the change in retention behavior induced by the flow velocity variation for the dual gradient columns was quite different from that by the variation in organic modifier content of the mobile phase in isocratic elution for a single gradient column and can induce the similar effect with an ordinary gradient elution in a mobile phase composition.  相似文献   

5.
6.
Metoprolol and a number of related amino alcohols and similar analytes have been chromatographed on aminopropyl (APS) and ethylpyridine (EPS) silica columns. The mobile phase was carbon dioxide with methanol as modifier and no amine additive was present. Optimal isocratic conditions for the selectivity were evaluated based on experiments using design of experiments. A central composite circumscribed model for each column was used. Factors were column temperature, back-pressure and % (v/v) of modifier. The responses were retention and selectivity versus metoprolol. The % of modifier mainly controlled the retention on both columns but pressure and temperature could also be important for optimizing the selectivity between the amino alcohols. The compounds could be divided into four and five groups on both columns, with respect to the selectivity. Furthermore, on the aminopropyl silica the analytes were more spread out whereas on the ethylpyridine silica, due to its aromaticity, retention and selectivity were closer. For optimal conditions the column temperature and back-pressure should be high and the modifier concentration low. A comparison of the selectivity using optimized conditions show a few switches of retention order between the two columns. On aminopropyl silica an aldehyde failed to be eluted owing to Schiff-base formation. Peak symmetry and column efficiency were briefly studied for some structurally close analogues. This revealed some activity from the columns that affected analytes that had less protected amino groups, a methyl group instead of isopropyl. The tailing was more marked with the ethylpyridine column even with the more bulky alkyl substituents. Plate number N was a better measure than the asymmetry factor since some analyte peaks broadened without serious deterioration of symmetry compared to homologues.  相似文献   

7.
Spray-dried, spherical synthetic hectorite particles have been thermally-treated at 500 degrees C for 16 h and used as adsorbent materials in reversed-phase liquid chromatography. The retention of a 22 mono and disubstituted aromatic compounds was evaluated to study the retention mechanisms on the clay mineral. The retention of solutes on the thermally-treated clays was markedly different than that measured on octadecylsilica (ODS) columns under identical conditions, but remarkably similar to retention characteristics of the same solutes on porous graphitic carbon columns. The clay columns exhibit an enhanced selectivity over the ODS column in separation of nitroaromatic positional isomers. Under identical mobile phase compositions, a selectivity, alpha, of 7.15 between ortho- and para-dinitrobenzene isomers was measured on the clay column compared to a alpha of 1.04 on the ODS column.  相似文献   

8.
Most commercially available instruments for capillary electrochromatography (CEC) have a fixed configuration and lack the flexibility to use shorter columns. Applying a blended stationary phase (a phase consisting of a given ratio of bare silica and reversed phase material) can simulate columns of different length in CEC. The goal of this work was to examine the effect of the degree of blending of reversed-phase columns (with bare silica) on the speed of the separation of neutral compounds in CEC. Optimum column packing mixture was determined from the variation of the solute retention factors as a function of the ratios of blending of reversed-phase and bare silica. By adjusting the column composition, solute retention factors and the analysis run time were halved when compared to a pure reversed-phase column of the same length. Stationary phase blending can be considered as an additional parameter to mobile phase variation, column temperature and applied electric field for the optimization of selectivity and analysis time. By adjusting the stationary phase composition, mobile phase composition, column temperature and applied electric field, the analysis run time of neutral components was decreased more than 75% when compared to a separation obtained on neat reversed-phase column of the same dimensions. The linear dependence of the retention factors as a function of the blend ratio (reversed phase/bare silica) offers a framework for designing a “blended” packed capillary column for CEC separations.  相似文献   

9.
A commercial Chromolith C18 column and two new stationary phases with mixed ligands bonded on the Kromasil silica gel support, SG-MIX and SG-Chol, were characterized using simple tests based on the retention of non-polar, basic and acidic compounds. Polar and methylene selectivity tests in acetonitrile-water and methanol-water mobile phases revealed lower hydrophobicities of the SG-MIX and SG-Chol columns in comparison to the Chromolith column. The columns were further characterized using new test criteria - gradient oligomer capacity and isomeric selectivity and peak symmetry of naphthalene di-sulphonic acids in aqueous mobile phases. The cholesterolic column shows greater gradient oligomer selectivity for the separation of oligoethylene glycol samples than the SG-MIX and the Chromolith columns. Increased retention and peak tailing, but decreased isomeric selectivity for naphthalene-di-sulphonic acids was observed with the SG-MIX column, because of interactions with various polar bonded groups.  相似文献   

10.
A high-temperature liquid chromatographic technique is employed for the separation of commercially available polymer additives to enhance the resolution and speed. Separation efficiencies and elution behaviors for seven phthalate plasticizers and five antioxidants are evaluated at elevated column temperatures and with a thermal gradient. Diamondbond C18 (octadecylsilica), Zirchrom PS (zirconia-based polystyrene), and Zirchrom PBD (zirconia-based polybutadiene) columns are selected for the study because of their thermal stability. The temperature programming is controlled with a column oven in conjunction with an independent mobile phase preheater and a post-column effluent cooling assembly. Van't Hoff plots show that the reverse-phase liquid chromatography mechanism is maintained over a wide range of column temperatures. A 1% increase of acetonitrile in the mobile phase is estimated to have a comparable effect as a 7-7.5 degrees C column temperature increase on the retention time changes.  相似文献   

11.
Molander P  Olsen R  Lundanes E  Greibrokk T 《The Analyst》2003,128(11):1341-1345
The impact of column inner diameter on chromatographic performance in temperature gradient liquid chromatography has been investigated in the present study. Columns with inner diameters of 0.32, 0.53, 3.2 and 4.6 mm were compared with respect to retention and efficiency characteristics using temperature gradients from 30 to 90 degrees C with temperature ramps of 1, 5, 10 and 20 degrees C min(-1). The columns were all of 15 cm length and were packed with 3 microm Hypersil ODS particles. Alkylbenzenes served as model compounds, and the mobile phase consisted of acetonitrile-water (50:50, v/v). The study revealed that the column ID is not a critical limiting factor when performing temperature programming in LC, at least for columns narrower than 4.6 mm inner diameter in the temperature interval 30-90 degrees C. The retention times for all components on all columns were highly comparable, with similar peak profiles without any signs of peak splitting. The use of mobile phase pre-heating when using the larger bore columns was avoided by starting the temperature gradients close to ambient. However, the relative apparent efficiency was inversely proportional to column inner diameter, making the capillary columns generally more functional towards temperature gradients than the larger bore columns with respect to chromatographic efficiency. In addition, the capillary columns possessed higher robustness towards temperature programming than the conventional columns.  相似文献   

12.
The regeneration of ion-pairing reagent distribution on liquid chromatography columns after gradient elution has been well recognized as the cause for long column equilibration time, a major drawback associated with gradient elution reverse phase ion-pair chromatography. To date, the majority of studies have focused on optimizing the separation conditions to shorten the equilibration time. There is limited understanding of the ion-pairing reagent distribution process between the mobile phase and stationary phase in the course of gradient elution, and subsequent column re-equilibration. The focus of this work is to gain a better understanding of this process. An ion-pair chromatographic system, equipped with a YMC ODS C(18) column and a mobile phase containing tetrabutylammonium (TBA) hydroxide as the ion-pairing reagent, was used in the study. The TBA distribution profile was established by measuring its concentration in the eluent fractions collected during the gradient cycle using different column equilibration times with an ion chromatographic method. Furthermore, the analyte retention time was evaluated as the function of the column equilibration time and TBA concentration in the mobile phase. The column equilibration and its impact on the method robustness will also be discussed.  相似文献   

13.
L. Szepesy  G. Rippel 《Chromatographia》1992,34(5-8):391-397
Summary Retention and selectivity in hydrophobic interaction chromatography (HIC) depend both on the type of stationary phase and on the mobile phase. In the last few years various high performance packing materials and columns have been introduced for HIC resulting in a range of different retentions and selectivity. We have investigated the effect of the stationary phase on the retention of various proteins. The retention of some solutes of different hydrophobicities were measured on three commercial HIC columns (TSK-Phenyl, Synchropack-Propyl, CAA-HIC) under isocratic conditions using water-methanol mixtures as eluent. The log kw values determined according to the literature were devalues determined according to the literature were dependent on the type and structure of the stationary phase and indicated a much less hydrophobic character for these columns than that obtained for reversed phase columns. Gradient separations were then carried out on a standard protein mixture using ammonium sulfate and sodium citrate to change the gradient time. In order to compare the effect of the stationary phase and the two salts investigated apparent capacity factors (kg) were determined and plotted against the gradient time obtained for the three columns in the two eluent system. It was shown that the type of stationary phase had a significant effect on the retention of proteins. In addition, the effect of the mobile phase composition, i.e. salt type, was considerably different on the various stationary phases. In order to exploit the potential of HIC to modulate selectivity for the separation of proteins, the combined effect of the stationary phase and the type of salt should be taken into account.Dedicated to Professor Leslie S. Ettre on the occasion of his 70th birthday.  相似文献   

14.
Effective heat dissipation is critical for reproducible and efficient separations in electrically driven separation systems. Flow rate, retention kinetics, and analyte diffusion rates are some of the characteristics that are affected by variation in the temperature of the mobile phase inside the column. In this study, we examine the issue of Joule heating in packed capillary columns used in capillary electrochromatography (CEC). As almost all commonly used CEC packings are poor thermal conductors, it is assumed that the packing particles do not conduct heat and heat transfer is solely through the mobile phase flowing through the system. The electrical conductivity of various mobile phases was measured at different temperatures by a conductivity meter and the temperature coefficient for each mobile phase was calculated. This was followed by measurement of the electrical current at several applied voltages to calculate the conductivity of the solution within the column as a function of the applied voltage. An overall increase in the conductivity is attributed to Joule heating within the column, while a constant conductivity means good heat dissipation. A plot of conductivity versus applied voltage was used as the indicator of poor heat dissipation. Using theories that have been proposed earlier for modeling of Joule heating effects in capillary electrophoresis (CE), we estimated the temperature within CEC columns. Under mobile and stationary phase conditions typically used in CEC, heat dissipation was found to be not always efficient. Elevated temperatures within the columns in excess of 23 degrees C above ambient temperature were calculated for packed columns, and about 35 degrees C for an open column, under a given set of conditions. The results agree with recently published experimental findings with nuclear magnetic resonance (NMR) thermometry, and Raman spectroscopic measurements.  相似文献   

15.
Strongly polar phenolic acids are weakly retained and often poorly separated in reversed-phase (RP) liquid chromatography. We prepared zwitterionic polymethacrylate monolithic columns for micro-HPLC by in situ co-polymerization in fused-silica capillaries. The capillary monolithic columns prepared under optimized polymerization conditions show some similarities with the conventional particulate commercial ZIC-HILIC silica-based columns, however have higher retention and better separation selectivity under reversed-phase conditions, so that they can be employed for dual-mode HILIC-RP separations of phenolic acids on a single column. The capillary polymethacrylate monolithic sulfobetaine columns show excellent thermal stability and improved performance at temperatures 60–80 °C. The effects of the operation conditions on separation were investigated, including the type and the concentration of the organic solvent in the aqueous-organic mobile phase (acetonitrile and methanol), the ionic strength of the acetate buffer and temperature. While the retention in the RP mode decreases at higher temperatures in mobile phases with relatively low concentrations of acetonitrile, it is almost independent of temperature at HILIC conditions in highly organic mobile phases. The best separation efficiency can be achieved using relatively high acetate buffer ionic strength (20–30 mmol L−1) and gradient elution with alternately increasing (HILIC mode) and decreasing (RP mode) concentration of aqueous buffer in aqueous acetonitrile. Applications of the monolithic sulfobetaine capillary columns in alternating HILIC-RP modes are demonstrated on the analysis of phenolic acids in a beer sample.  相似文献   

16.
A convenient method for the simultaneous determination of various DHPG species present in biological samples is presented. This method utilizes a cation exchange column (25 cm X 4.6 mm i.d.) coupled in series to a short reversed-phase column (5 cm X 4.6 mm i.d.). The mobile phase consists of methanol:0.005M ammonium phosphate buffer, pH 2.5. There is a large polarity difference between DHPG and its esters due to the non-polar side chain of the ester moiety. The simultaneous determination of the diesters, monoesters, and DHPG in these samples using only the cation exchange or the reversed-phase column is not possible without time-consuming gradient elution. In the reversed-phase mode alone, the esters are highly retained relative to DHPG, whereas the esters are only slightly retained on a cation exchange column and are insensitive to changes in pH and ionic strength of the mobile phase. However, a combination of these two columns provides interesting selectivity for these compounds and offers a unique way of controlling the retention times of these species relative to each other. The retention time of esters can be selectively altered (with respect to DHPG) by changing the composition of methanol in the mobile phase. In contrast, the retention time of DHPG is controlled by changing the buffer strength and pH of the mobile phase.  相似文献   

17.
Characteristics of electroosmotic flow (EOF) and the migration of neutral solutes under double stepwise gradient elution in capillary electrochromatography were studied systematically. EOF velocity proved to be the function of operation time changing with the introduction of the second mobile phase. Accordingly, the retention of components also changed. The migration of neutral solutes was studied under the following three situations; A, components eluted when the column was filled only with the first kind of mobile phase; B, solutes eluted still in the first kind of mobile phase while at that time two kinds of mobile phase coexisted in the column and C, samples eluted in the second kind of mobile phase. Equations to describe the retention times of components under these three kinds of conditions were deduced and applied to predict the retention times of 12 aromatic compounds. Relative errors between experimental and calculated values were below 5.0%, which proved the reliability of the equations. In addition, parameters that might affect the retention time of solutes, such as the transferring time of mobile phase vials, the capacity factors of components and EOF velocities two steps were studied systematically.  相似文献   

18.
Once a suitable stationary phase and column dimensions have been selected, the retention in liquid chromatography (LC) is traditionally adjusted by controlling the mobile phase composition. Solvent gradients enable achievement of good separation selectivity while decreasing the separation time as compared to isocratic elution. Capillary columns allow use of other programming parameters, i.e. temperature and applied electric fields, in addition to solvent gradient elution. This paper presents a review of programmed separation techniques in miniaturized LC, including retention modeling and method transfer from the conventional to micro- and capillary scales. The impact of miniaturized instrumentation on retention and the limitations of capillary LC are discussed. Special attention is focused on the gradient dwell volume effects, which are more important in micro-LC techniques than in conventional analytical LC and may cause significant increase in the time of analysis, unless special instrumentation and (or) pre-column flow-splitting is used. The influence of temperature upon retention is also discussed, and applications where the temperature has been actively used for retention control in capillary LC are included together with the instrumentation utilized. Finally the possibilities of additional selectivity control by applying an electric field over a packed capillary LC column are discussed.  相似文献   

19.
The promising technique of controlling chromatographic selectivity by the adjustment of individual column temperatures in systems of series-coupled columns is investigated by means of a general model incorporating the effects of temperature and mobile phase compressibility. Expressions are derived for the linear flow velocity, the effective partition coefficient and the retention time for a system of n columns assuming an ideal mobile phase gas, under conditions of constant overall pressure drop and neglect of the temperature dependence of the mobile phase viscosity. The results indicate the importance of thermodynamic parameters, relative to parameters influencing the linear flow velocity, in determining the effect of temperature on the chromatographic retention time. Numerical results are illustrated graphically for two-column systems which are discussed in greater detail. Switching of columns is also discussed and it is shown that even if thermodynamic contributions remain unchanged, non-thermodynamic contributions have a notice-able effect.  相似文献   

20.
Three types of thiol compounds (n-octadecanethiol, thiophenol, and 2-phenylethanethiol) were used to modify the gold-coated polystyrene particles (dp. 5microm) to prepare a stationary phase for capillary liquid chromatography through the formation of self-assembled monolayer. The column with n-octadecanethiol-modified gold-coated polystyrene particles (C18-Au) demonstrated the higher affinity to phenanthrene and anthracene than small aromatics compared to the ODS column. In addition, the shape selectivity between phenanthrene and anthracene in the C18-Au column was much higher than that in the ODS column (separation factors: 1.82 and 1.14, respectively). The relationship between the retention factor and acetonitrile content in the mobile phase revealed that the retention behaviors in the C18-Au column was more sensitive on the acetonitrile content than those in the ODS column. Relatively higher affinity for phenanthrene and anthracene was commonly observed in all the three thiol-modified Au columns than that for the conventional ODS column, whereas separations of benzene and nitro- and chlorobenzenes were quite different among the three thiol-modified Au and ODS columns.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号