首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Zhou S  Tan J  Chen Q  Lin X  Lü H  Xie Z 《Journal of chromatography. A》2010,1217(52):8346-8351
A novel open tubular (OT) column covalently modified with hydrophilic polysaccharide, carboxymethylchitosan (CMC) as stationary phase has been developed, and employed for the separations of basic proteins and opium alkaloids by capillary electrochromatography (CEC). With the procedures including the silanization of 3-aminopropyltrimethoxysilane (APTS) and the combination of glutaraldehyde with amino-silylated silica surface and CMC, CMC was covalently bonded on the capillary inner wall and exhibited a remarkable tolerance and chemical stability against 0.1 mol/L HCl, 0.1 mol/L NaOH or some organic solvents. By varying the pH values of running buffer, a cathodic or anodic EOF could be gained in CMC modified column. With anodic EOF mode (pH<4.3), favorable separations of basic proteins (trypsin, ribonuclease A, lysozyme and cytochrome C) were successfully achieved with high column efficiencies ranging from 97,000 to 182,000 plates/m, and the undesired adsorptions of basic proteins on the inter-wall of capillary could be avoided. Good repeatability was gained with RSD of the migration time less than 1.3% for run-to-run (n=5) and less than 3.2% for day-to-day (n=3), RSD of peak area was less than 5.6% for run-to-run (n=5) and less than 8.8% for day-to-day (n=3). With cathodic EOF mode (pH>4.3), four opium alkaloids were also baseline separated in phosphate buffer (50 mmol/L, pH 6.0) with column efficiencies ranging from 92,000 to 132,000 plates/m. CMC-bonded OT capillary column might be used as an alternative medium for the further analysis of basic proteins and alkaline analytes.  相似文献   

2.
A novel polymethacrylate‐based monolithic column with covalently bonded zwitterionic functional groups was prepared by in situ copolymerization of N,N‐dimethyl‐N‐methacryloxyethyl N‐(3‐sulfopropyl) ammonium betaine (SPE), pentaerythritol triacrylate (PETA), and vinylsulfonic acid (VS) in a binary porogenic solvent consisting of cyclohexanol and ethylene glycol. This monolith was developed as a separation column for CEC. While SPE functioned as both an electrostatic interaction stationary phase and the polar ligand provider, VS was employed to generate EOF. PETA, which has much more hydrophilicity due to a hydroxyl sub‐layer, was used to replace ethylene dimethacrylate as a cross‐linker. The monolith provided an adequate EOF when VS level was maintained at 0.6% w/w. Different monolithic stationary phases were easily prepared by adjusting the ratio of PETA/SPE in the polymerization solution as well as the composition of the porogenic solvent. The observed RSD were ≤3.6, ≤4.3 and ≤5.6% for the EOF velocity, retention time, and column efficiency, respectively. The column efficiencies greater than 145 000 theoretical plates/m for thiourea and 132 000 theoretical plates/m for charged cytidine were obtained. The poly(SPE‐co‐PETA‐co‐VS) monolith showed good selectivity for neutral and charged polar analytes. It was found that the separation mechanism of charged polar solutes was attributed to a mixed mode of hydrophilic interaction and electrostatic interaction, as well as electrophoresis. No peak tailing was observed for the separation of basic compounds, such as basic nucleic acid bases and nucleoside on the monolith.  相似文献   

3.
Xu L  Sun Y 《Journal of chromatography. A》2008,1183(1-2):129-134
The use of a phenylalanine (Phe) functionalized tentacle-type polymer coated capillary column for protein separation by open tubular capillary electrochromatography (OTCEC) was demonstrated in this work. The tentacle-type stationary phase was prepared from silanized fused-silica capillaries of 50 microm I.D. by glycidyl methacrylate graft polymerization and subsequent Phe functionalization. Due to the amphoteric functional groups of the Phe bonded on the tentacle-type polymer stationary phase, protein separation in the prepared column can be performed under both cathodic and anodic electroosmotic flow (EOF) by varying the pH values of the mobile phase. Model proteins including ribonuclease A (RNase A), myoglobin, transferrin, insulin were baseline separated under cathodic EOF with a mobile phase of pH 8.8. Comparison between the separation result of the four proteins under conditions of OTCEC and capillary zone electrophoresis indicates that the migration behavior of the four proteins in the prepared column was the result of the interplay of chromatographic retention and electrophoretic migration. Besides, three basic proteins including RNase A, cytochrome c (Cyt-c) and lysozyme (Lys) were fully resolved under anodic EOF with an acidic running buffer (pH 2.5). The elution order was the same as the isoelectric point values of the proteins (RNase A相似文献   

4.
δ‐Gluconolactone was covalently coupled with aminopropyl‐derivatized capillary, creating hydrophilic brushes on the inner wall of the capillary. The hydrophilic coating provided suppression of EOF and minimized protein adsorption, resulting in the separation of basic proteins and DNA with efficiencies up to 450 000 plates/m. The intra‐ and inter‐day repeatabilities of the coating referring to the migration times of the four tested proteins were satisfactory with RSD of no more than 1.1 and 1.8% (n=5), respectively. Two hundred consecutive runs were performed with negligible change in migration times and efficiency.  相似文献   

5.
A novel open‐tubular CEC column coated with chitosan‐graft‐(β‐CD) (CDCS) was prepared using sol‐gel technique. In the sol‐gel approach, owing to the 3D network of sol‐gel and the strong chemical bond between the stationary phase and the surface of capillary columns, good chromatographic characteristics and unique selectivity in separating isomers were shown. The column efficiencies of 55 000~163 000 plates/m for the isomeric xanthopterin and phenoxy acid herbicides using the sol‐gel‐derived CDCS columns were achieved. Good stabilities were demonstrated that the RSD values for the retention time of thiourea and isoxanthopterin were 1.3 and 1.4% (run to run, n = 5), 1.6 and 2.0% (day to day, n = 3), 2.9 and 3.1% (column to column, n = 3), respectively. The sol‐gel‐coated CDCS columns have shown improved separations of isomeric xanthopterin in comparison with CDCS‐bonded capillary column.  相似文献   

6.
Wei W  Ju H 《Electrophoresis》2005,26(3):586-592
A zwitterionic surfactant, dodecyldimethyl (2-hydroxy-3-sulfopropyl) ammonium (C12H25N+(CH3)2CH2CHOHCH2SO3-), named dodecyl sulfobetaine (DSB), was used as a novel modifier to coat dynamically capillary walls for capillary electrophoresis separation of basic proteins. The DSB coating suppressed the electroosmotic flow (EOF) in the pH range of 3-12. At high DSB concentration, the EOF was suppressed by more than 8.8 times. The DSB coating also prevented successfully the adsorption of cationic proteins on the capillary wall. Anions, such as Cl-, Br-, I-, SO4(2-), CO3(2-), and ClO4-, could be used as running buffer modifiers to adjust the EOF for better separation of analytes. Using this dynamically coated capillary, a mixture of eight inorganic anions achieved complete separation within 4.2 min with the efficiencies from 24,000 to 1,310,000 plates/m. In the presence of ClO4- as EOF adjustor, the separation of a mixture containing four basic proteins (lysozyme, cytochrome c, alpha-chymotrypsinogen A, and myoglobin) yielded efficiencies of 204,000-896,000 plates/m and recoveries of 88%-98%. Migration time reproducibility of these proteins was less than 0.5% relative standard deviation (RSD) from run to run and less than 3.1% RSD from day to day, showing promising application of this novel modifier in protein separation.  相似文献   

7.
A pyridinium‐based immobilized ionic liquid type multifunctional hybrid silica monolith was prepared by the in situ polymerization of 3‐chloropropyl‐silica matrix and 4,4′‐dipyridyl for hydrophilic interaction CEC. The obtained hybrid monolith possessed of high stable skeletal microstructures with obviously hydrophilic retention mechanism under ACN content >50% in the mobile phase. Strong and stable anodic EOF could be observed under a broad pH range from pH 3.0 to 9.0. Due to the immobilized dipyridyl groups bonded to the silica matrix surface, the resulting hydrophilic hybrid monolith possessed multiple separation interactions including hydrogen bond, π–π, and anion exchange. Excellent separations of various polar analytes including electroneutral phenols, charged acid nucleotides, and basic analytes were successfully achieved. The highest column efficiencies up to 120 000, 164 000, and 106 000 plates/m were obtained for nucleotides, nucleic acid bases, and nucleosides and nicotines, respectively. These results demonstrated that the dipyridyl‐immobilized ionic liquid functionalized hybrid monolith possessed highly mechanical stability and good chromatographic performance for hydrophilic interaction electrochromatography.  相似文献   

8.
A neutral, nonpolar monolithic capillary column was evaluated as a hydrophobic stationary phase in pressurized CEC system for neutral, acidic and basic solutes. The monolith was prepared by in situ copolymerization of octadecyl methacrylate and ethylene dimethacrylate in a binary porogenic solvent consisting of cyclohexanol/1,4‐butanediol. EOF in this hydrophobic monolithic column was poor; even the pH value of the mobile phase was high. Because of the absence of fixed charges, the monolithic capillary column was free of electrostatic interactions with charged solutes. Separations of neutral solutes were based on the hydrophobic mechanism with the pressure as the driving force. The acidic and basic solutes were separated under pressurized CEC mode with the pressure and electrophoretic mobility as the driving force. The separation selectivity of charged solutes were based on their differences in electrophoretic mobility and hydrophobic interaction with the stationary phase, and no obvious peak tailing for basic analytes was observed. Effects of the mobile phase compositions on the retention of acidic compounds were also investigated. Under optimized conditions, high plate counts reaching 82 000 plates/m for neutral compounds, 134 000 plates/m for acid compounds and 150 000 plates/m for basic compounds were readily obtained.  相似文献   

9.
In this work, an open‐tubular capillary liquid‐phase column was prepared by modifying chain polymer on the inner surface of capillary and chemical bonding of metal organic frameworks, NH2‐UiO‐66, to the brushes of chain polymer (poly(glycidyl methacrylate)). Besides advantages of facial preparation and good permeability, the chain polymer effectively increases the modification amount of NH2‐UiO‐66 nanoparticles to increase the phase ratio of open‐tubular capillary column and enhance the interactions with analytes. The results of scanning electron microscope energy‐dispersive X‐ray spectra indicated that NH2‐UiO‐66 nanoparticles were successfully bonded to the chain polymer. Because of the hydrophobic interaction and hydrogen bonding interaction between the analytes and the ligand of NH2‐UiO‐66, different analytes were well separated on the NH2‐UiO‐66‐modified poly(glycidyl methacrylate) capillary (1.12 m × 25 μm id × 365 μm od) with the high absolute column efficiency reaching 121 477 plates, benefiting from an open‐tubular column and low mass transfer resistance provided by polymer brush and metal–organic framework crystal. The relative standard deviations of the retention time for run‐to‐run, day‐to‐day, and column‐to‐column (= 3) runs are below 4.28%, exhibiting good repeatability. Finally, the column was successfully applied to separation of flavonoids in licorice.  相似文献   

10.
Enantioselective open tubular capillary electrochromatography with carboxymethyl‐β‐cyclodextrin conjugated gold nanoparticles as stationary phase was developed. This novel open tubular column was fabricated through layer‐by‐layer self‐assembly of gold nanoparticles on a 3‐mercaptopropyl‐trimethoxysilane‐modified fused‐silica capillary and subsequent surface functionalization of the gold nanoparticles through self‐assembly of 6‐mercapto‐β‐cyclodextrin. The 6‐mercapto‐β‐cyclodextrin was firstly synthesized and determined by extensive spectroscopic data. Scanning electron microscopy, energy dispersive X‐ray analysis spectroscopy, and electroosmotic flow experiments were carried out to characterize the prepared open tubular column. Then, the separation effectiveness of the open tubular column was verified by two pairs of ɑ‐tetralones derivatives enantiomers and two pairs of basic drug enantiomers (tramadol hydrochloride and zopiclone) as mode analytes. Factors that influence the enantioseparation were optimized, and under the optimized conditions, satisfactory separation results were obtained for the four enantiomers: compound A, compound B, tramadol hydrochloride, and zopiclone with resolutions of 3.79, 1.56, 1.03, 1.60, respectively. For the combination of gold nanoparticles and negatively charged carboxymethyl‐β‐cyclodextrin, the open tubular column exhibited wider separation range for neutral and basic drugs. Moreover, the repeatability and stability of the column were studied through the run‐to‐run and day‐to‐day investigations.  相似文献   

11.
Dong X  Dong J  Ou J  Zhu Y  Zou H 《Electrophoresis》2006,27(12):2518-2525
A polymer-based neutral monolithic capillary column was prepared by radical polymerization of glycidyl methacrylate and ethylene dimethacrylate in a 100 mum id fused-silica capillary, and the prepared monolithic column was subsequently modified based on a ring opening reaction of epoxide groups with 1 M lysine in solution (pH 8.0) at 75 degrees C for 10 h to produce a lysine chemically bonded stationary phases in capillary column. The ring opening reaction conditions were optimized so that the column could generate substantial EOF. Due to the zwitterionic functional groups of the lysine covalently bonded on the polymer monolithic rod, the prepared column can generate cathodic and anodic EOF by varying the pH values of running buffer during CEC separation. EOF reached the maximum of -2.0 x 10(-8) m2v(-1)s(-1) and 2.6 x 10(-8) m2v(-1)s(-1) with pH of the running buffer of 2.25 and 10, respectively. As a consequence, neutral compounds, ionic solutes such as phenols, aromatic acids, anilines, and basic pharmaceuticals were all successfully separated on the column by CEC. Hydrophobic interaction is responsible for separation of neutral analytes. In addition, the electrostatic and hydrophobic interaction and the electrophoretic migration play a significant role in separation of the ionic or ionizable analytes.  相似文献   

12.
Hsieh YL  Chen TH  Liu CP  Liu CY 《Electrophoresis》2005,26(21):4089-4097
A novel column made through the condensation reaction of TiO2 nanoparticles (TiO2 NPs) with silanol groups of the fused-silica capillary is described. EOF measurements under various buffer constitutions were used to monitor the completion of reactions. The results indicated that the EOF was dependent on the interactions between buffers and the bonded TiO2 NPs. With formate/Tris buffer, EOF reversal at pH below 5 and cathodic EOF at pH above 5 were indicated. The pI of the bonded TiO2 NPs was found at approximately ph 5. Only cathodic EOF was illustrated by substituting the mobile phase with either glutamate or phosphate buffer. It was elucidated that both glutamate and phosphate buffer yield a negative charge layer on the surface of TiO2 NPs attributable to the formation of a titanium complex. The CEC performance of the column was tested with angiotensin-type oligopeptides. Some parameters that would affect the retention behavior were investigated. The interactions between the bonded phases and the analytes were explicated by epitomized acid-base functional groups of the oligopepetides and the speciation of the surface oxide in different pH ranges. The average separation efficiencies of 3.1 x 10(4) plates/m is readily achieved with a column of 70 cm (50 cm) x 50 mum ID under an applied voltage of 15 kV, phosphate buffer (pH 6.0, 40 mM), and UV detection at 214 nm.  相似文献   

13.
《Electrophoresis》2018,39(7):941-947
In this paper, β‐cyclodextrin (β‐CD) modified gold nanoparticles (AuNPs) coated open tubular column (OT column) was prepared for capillary electrochromatography. The open tubular column was constructed through self‐assembly of gold nanoparticles on 3‐mercaptopropyl‐trimethoxysilane (MPTMS) prederivatized capillary and subsequent modification of thiols β‐cyclodextrin (SH‐β‐CD). Scanning electron microscopy (SEM), transmission electron microscopy (TEM) and ultraviolet visible spectroscopy were carried out to characterize the prepared open tubular column and synthesized gold nanoparticles. By comparing different coating times of gold nanoparticles and thiols β‐cyclodextrin, we got the optimal conditions for preparing the open tubular column. Also, the separation parameters were optimized including buffer pH, buffer concentration and applied voltage. Separation effectiveness of open tubular column was verified by the separation of four pairs of drug enantiomers including bifonazole, fexofenadine, omeprazole and lansoprazole, and satisfactory separation results were achieved for these analytes studied. In addition, the column showed good stability and repeatability. The relative standard deviation values less than 5% were obtained through intra‐day, inter‐day, and column‐to‐column investigations.  相似文献   

14.
With unique 3‐D architecture, the application of core‐based hyperbranched polyethyleneimine (CHPEI), as a capillary coating in capillary electrophoresis, is demonstrated by manipulation of the electroosmotic mobility (EOF). CHPEI coatings (CHPEI5, Mw ≈? 5000 and CHPEI25, Mw ≈? 25 000) were physically adsorbed onto the inner surface of bare fused‐silica capillary (BFS) via electrostatic interaction of the oppositely charged molecules by rinsing the capillaries with different CHPEI aqueous solutions. The EOF values of the coated capillaries were measured over the pH range of 4.0–9.0. At higher pH (pH >6) the coated capillary surface possesses excess negative charges, which causes the reversal of the EOF. The magnitudes of the EOF obtained from the coated capillaries were three‐fold lower than that of BFS capillary. Desirable reproducibility of the EOF with % RSD (n = 5) ? 2 was obtained. Effect of ionic strength, stability of the coating (% RSD = 0.3) and the dependence of the EOF on pH (% RSD = 0.5) were also investigated. The CHPEI‐coated capillaries were successfully utilized to separate phenolic compounds, B vitamins, as well as basic drugs and related compounds with reasonable analysis time (<20 min) and acceptable migration‐time repeatability (<0.7% RSD for intra‐capillary and <2% RSD for inter‐capillary).  相似文献   

15.
Continuous-bed columns containing sol-gel bonded 3 microm silica particles with mixed-mode octadecyl and propylsulfonic acid functional groups (ODS/SCX) were prepared by first packing the ODS/SCX particles into a fused-silica capillary, then filling the packed capillary with a siliceous sol-gel, curing the sol-gel, and finally drying the column with supercritical carbon dioxide. The performance of the sol-gel bonded ODS/SCX columns was evaluated for capillary electrochromatography using acetonitrile aqueous mobile phase containing phosphate buffer. The columns were mechanically strong and permeable. Both EOF velocity and current increased linearly with elevation of the applied electric field strength. The EOF velocity was high at low pH and nearly constant over a range of pH 2-9. Higher buffer concentration resulted in higher current and lower EOF velocity. The acetonitrile content had no significant effect on the EOF. Without thermosetting the column, no bubble formation was noticed with currents up to 2.5 microA. The minimum plate height of a 25/34 cm x 75 microm I.D. sol-gel bonded 3 microm ODS/SCX column was 5.7 microm (1.75 x 10(5) plates per meter) at an optimum EOF velocity of 0.92 mm s(-1). Mixtures of test aromatic compounds and aromatic hydrocarbon homologues gave symmetrical peaks when using a low pH mobile phase. The retention and elution order of aromatic compounds represented a typical reversed-phase separation mechanism similar to conventional ODS columns. The run-to-run and column-to-column retention factor reproducibility was better than 2.5% and 8.0% RSD, respectively.  相似文献   

16.
In this study, the dissolution of polysaccharides into an ionic liquid was investigated and applied as a coating onto the capillary walls of a fused‐silica capillary in open‐tubular CEC. The coating was evaluated by examining the chiral separation of two analytes (thiopental, sotalol) with three cellulose derivatives (cellulose acetate, cellulose acetate phthalate, and cellulose acetate butyrate). Baseline separation of thiopental enantiomers was achieved by use of each polysaccharide coating (Rs: 7.0, 8.1, 7.1), while sotalol provided partial resolution (Rs: 0.7, 1.0, 0.9). In addition, reproducibility of the cellulose‐coated capillaries was evaluated by estimating the run‐to‐run and capillary‐to‐capillary RSD values of the EOF. Both stability and reproducibility were very good with RSD values of less than 7%.  相似文献   

17.
1‐Butyl‐3‐[(3‐trimethoxysilyl)propyl]imidazolium chloride ionic liquid was synthesized and chemically modified onto the inner wall of a fused capillary column as a stationary phase for gas chromatography. The 1‐butyl‐3‐[(3‐trimethoxysilyl)propyl]imidazolium chloride ionic liquid bonded capillary column was evaluated in detail. The results revealed that the ionic liquid bonded capillary column exhibited high column efficiency of 1.08 × 104 plates/m, and good chromatographic separation selectivity (α ) for polar and non‐polar substances, and a good thermal stability between room temperature and 400°C. Moreover, the determination of thermodynamic parameters and the linear solvation energy relationship were further carried out. The results indicated that the chromatographic retention of each probe molecule on the ionic liquid bonded stationary phase was an enthalpy‐driven process, and the system constants of the linear solvation energy relationship signified that the dispersion interaction, the hydrogen bonding acidity and hydrogen bonding basicity were dominant interactions between probes and stationary phase among five interactions during the chromatographic separation. However, the contribution of each specific interaction for the stationary phase is ranked as the dispersion interaction > the hydrogen bonding basicity > the hydrogen bonding acidity.  相似文献   

18.
A novel tentacle-type polymer stationary phase covalently modified with branched polyethyleneimine (PEI) was developed for peptides and proteins separations by open-tubular CEC (OT-CEC). The preparation procedure included the silanization of capillary inner wall, in situ graft polymerization and PEI functionalization. A wrinkly polymer surface of multitudinous steric amine groups was evenly formed on the capillary inner wall, and anodic EOF could be gained within a wide pH range of 2.5-7.5. The electroosmotic mobility was examined for its dependence on pH as well as PEI concentrations. Good repeatability was gained with RSD for the migration time of EOF marker within 4.8% and satisfactory chemical stability was validated. Due to the existence of amine groups on the surface of tentacle-type polymer stationary phase, the silanol effect that occurs between the positively charged biomolecules and the silanols of the capillary column was greatly suppressed. Compared with a monolayer-coating capillary, seven enkephalin-related peptides were well resolved on the PEI-bonded column with high efficiencies. Favorable separations of peptides and proteins with high column efficiencies were obtained in 144,000-189,000 and 97,000-170,000 plates/m. Branched PEI-bonded tentacle-type polymer stationary phase has been proven to afford satisfactory retention and resolution of peptides and proteins.  相似文献   

19.
In this work, we developed a capillary column modified with zeolitic imidazolate framework‐8 as a novel stationary phase for open‐tubular capillary electrochromatography. To immobilize zeolitic imidazolate framework‐8 onto the inner surface of silica capillary, a bio‐inspired polydopamine functionalization was used to functionalize the capillary surface with polydopamine. First, a polydopamine layer was assembled inside the capillary. Second, due to noncovalent adsorption and covalent reaction ability, polydopamine could attract and anchor zeolitic imidazolate framework‐8 onto the inner surface of capillary. It has been demonstrated that zeolitic imidazolate framework‐8 was successfully grafted on the inner wall of the capillary by scanning electron microscopy, and Fourier transform infrared spectroscopy. The electro‐osmotic flow characteristics of capillaries were also investigated by varying the pH value and acetonitrile content of mobile phase. The zeolitic imidazolate framework‐8 coating not only increased the phase ratio of open‐tubular column, but also improved the interactions between tested analytes and the stationary phase. Three groups of isomers including acidic, basic, and neutral compounds were well separated on the zeolitic imidazolate framework‐8 bonded column, with theoretic plate numbers up to 1.9 × 105 N for catechol. The repeatability of the prepared columns was also studied, and the relative standard deviations for intra‐ and interday runs were less than 5%.  相似文献   

20.
Zhu Y  Zhou C  Qin S  Ren Z  Zhang L  Fu H  Zhang W 《Electrophoresis》2012,33(2):340-347
A novel open‐tubular capillary electrochromatography (OT‐CEC) with modified core/shell magnetic nanoparticles coating as stationary phase was introduced using external magnetic force to fix magnetic nanoparticles. The magnetic nanoparticles coating inside the capillary columns could be easily regenerated by removing and re‐applying the external magnetic field. Magnetic field intensity, concentration and flow rate of nanoparticles suspension were investigated to achieve simple and stable preparation. Mixture of five organic acids was used as the marker sample to evaluate the OT‐CEC system, and the relative column efficiency of anthranilic acid reaches 220 000 plates/m. The excellent within‐column and between‐column repeatability has been testified with the RSDs of retention time of less than 1.51 and 5.29%, respectively. The aqueous extract of rhizoma gastrodiae was analyzed by the OT‐CEC system, and 23 peaks were eluted in 30 min. Compared with conventional open‐tubular capillary column, this new system shows faster separation speed and higher column efficiency from the larger surface area of nanoparticles. It has great potential in the method development for the analysis of complex samples, since magnetic coating can effectively prolong the column life by expediently replacing stationary phase to eliminate the pollution or irreversible adsorption.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号