首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this article, the effect of spray solvent on the analysis of selected lipids including fatty acids, fat‐soluble vitamins, triacylglycerols, steroids, phospholipids, and sphingolipids has been studied by two different ambient mass spectrometry (MS) methods, desorption electrospray ionization‐MS (DESI‐MS) and desorption atmospheric pressure photoionization‐MS (DAPPI‐MS). The ionization of the lipids with DESI and DAPPI was strongly dependent on the spray solvent. In most cases, the lipids were detected as protonated or deprotonated molecules; however, other ions were also formed, such as adduct ions (in DESI), [M‐H]+ ions (in DESI and DAPPI), radical ions (in DAPPI), and abundant oxidation products (in DESI and DAPPI). DAPPI provided efficient desorption and ionization for neutral and less polar as well as for ionic lipids but caused extensive fragmentation for larger and more labile compounds because of a thermal desorption process. DESI was more suitable for the analysis of the large and labile lipids, but the ionization efficiency for less polar lipids was poor. Both methods were successfully applied to the direct analysis of lipids from pharmaceutical and food products. Although DESI and DAPPI provide efficient analysis of lipids, the multiple and largely unpredictable ionization reactions may set challenges for routine lipid analysis with these methods. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
3.
Desorption electrospray ionization mass spectrometry (DESI‐MS) is employed in the forensic analysis of chemical components present in condoms and imaging of latent fingerprints as circumstantial evidence of sexual assault. Polymers such as nonoxynol‐9, polyethylene glycol, and polydimethylsiloxane, as well as small molecules additives such as N‐methylmorpholine, N‐octylamine, N,N‐dibutyl formamide, and isonox 132, commonly used in lubricated condom formulations, were successfully characterized by DESI. The results suggest that DESI‐MS is useful for identification of this type of evidence, and it has advantages over conventional extractive techniques, in terms of speed of analysis and ease of use. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
Molecular images of documents were obtained by sequentially scanning the surface of the document using desorption atmospheric pressure chemical ionization mass spectrometry (DAPCI‐MS), which was operated in either a gasless, solvent‐free or methanol vapor‐assisted mode. The decay process of the ink used for handwriting was monitored by following the signal intensities recorded by DAPCI‐MS. Handwritings made using four types of inks on four kinds of paper surfaces were tested. By studying the dynamic decay of the inks, DAPCI‐MS imaging differentiated a 10‐min old from two 4 h old samples. Non‐destructive forensic analysis of forged signatures either handwritten or computer‐assisted was achieved according to the difference of the contour in DAPCI images, which was attributed to the strength personalized by different writers. Distinction of the order of writing/stamping on documents and detection of illegal printings were accomplished with a spatial resolution of about 140 µm. A Matlab® written program was developed to facilitate the visualization of the similarity between signature images obtained by DAPCI‐MS. The experimental results show that DAPCI‐MS imaging provides rich information at the molecular level and thus can be used for the reliable document analysis in forensic applications. © 2013 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons, Ltd.  相似文献   

5.
丁薛璐  段忆翔 《中国科学:化学》2014,(5):24-25,674,679
近年来,常压开源质谱解吸/离子化(ambient desorption/ionization mass spectrometry)技术的开发促进了质谱分析的蓬勃发展.作为常压开源质谱技术的一大重要分支,基于等离子体的常压质谱解吸/离子化技术因无需样品预处理、无溶剂化过程、高灵敏度、高通量、能实时在线检测样品等优点,受到了学术界及仪器制造、化学和生物分析等相关产业界的广泛关注.本文从离子源的种类、原理及应用等角度对目前我国在开源质谱领域中自主研发的基于等离子体的常压离子源的研究进展进行了总结,并对此类等离子体常压离子源的发展进行了展望,重点涉及微波等离子体源、常压微辉光放电等离子体源和解吸电晕束离子源.  相似文献   

6.
Desorption electrospray ionization mass spectrometry (DESI‐MS) requires little to no sample preparation and has been successfully applied to the study of biologically significant macromolecules such as proteins. However, DESI‐MS and other ambient methods that use spray desorption to process samples during ionization appear limited to smaller proteins with molecular masses of 25 kDa or less, and a decreasing instrumental response with increasing protein size has often been reported. It has been proposed that this limit results from the inability of some proteins to easily desorb from the surface during DESI sampling. The present study investigates the apparent mass dependence of the instrumental response observed during the DESI‐MS analysis of proteins using spray desorption collection and reflective electrospray ionization. Proteins, as large as 66 kDa, are shown to be quantitatively removed from surfaces by using spray desorption collection. However, incomplete dissolution and the formation of protein–protein and protein–contaminant clusters appear to be responsible for the mass‐dependent loss in sensitivity for protein analysis. Alternative ambient mass spectrometry approaches that address some of the problems encountered by spray desorption techniques for protein analysis are also discussed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
Electrospray laser desorption ionization is an ambient ionization technique that generates neutrals via laser desorption and ionizes those neutrals in an electrospray plume and was utilized to characterize inks in different layers of copy paper and banknotes of various currencies. Depth profiling of inks was performed on overlapping color bands on copy paper by repeatedly scanning the line with a pulsed laser beam operated at a fixed energy. The molecules in the ink on a banknote were desorbed by irradiating the banknote surface with a laser beam operated at different energies, with results indicating that different ions were detected at different depths. The analysis of authentic $US100, $100 RMB and $1000 NTD banknotes indicated that ions detected in ‘color‐shifting’ and ‘typography’ regions were significantly different. Additionally, the abundances of some ions dramatically changed with the depth of the aforementioned regions. This approach was used to distinguish authentic $1000 NTD banknotes from counterfeits. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
Electrospray laser desorption ionization mass spectrometry (ELDI/MS) was used to rapidly distinguish authentic banknotes from counterfeits of the US dollar and the New Taiwan dollar. The banknotes' surfaces were irradiated with a pulsed ultraviolet laser, after which the desorbed ink compounds entered an electrospray plume and formed ions via interactions with charged solvent species. Authentic banknotes were found to differ from their counterfeit equivalents in their surface chemical compositions. The detected chemical compounds included various polymers, plasticizers and inks; these results were comparable with those obtained using solvent extraction followed by electrospray ionization mass spectrometry analysis. Because of the high spatial resolution of the laser beam, ELDI/MS analysis resulted in minimal damage to the banknotes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
Displaced dual‐mode imaging (DDI) is introduced as a method for simultaneous imaging in positive and negative‐ion mode on the same sample with desorption electrospray ionization imaging, as well as a method for simultaneous imaging in full‐scan and tandem mass spectrometry (MS/MS) mode. DDI is performed by using a smaller row distance in the y‐direction than the desired image resolution and recording for example every second row in positive‐ion mode and the other half of the rows in negative‐ion mode, thus resulting in two separate images. This causes some degree of oversampling, which is thus utilized to obtain complementary mass spectrometric of the sample. Imaging with both polarities is exemplified on an imprint of a Hypericum perforatum leaf containing secondary metabolites which ionize in both polarites and a mouse kidney containing phospholipids which ionize in positive or negative mode only. Simultaneous full‐scan and MS/MS imaging was demonstrated on the same mouse kidney, as the mouse had been given a relatively low dose of the antidepressive drug amitriptyline. While the full‐scan data allowed imaging of the endogenous phospholipids, the drug and its metabolites were only visible in the MS/MS images. The latter approach is useful, for example in whole‐body imaging experiments where the full‐scan data gives an overview of the tissue, and the MS/MS mode provides the sensitivity to image trace amounts of drugs and metabolites. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
Chemical profiling of barley (Hordeum vulgare) leaves was demonstrated using direct and indirect desorption electrospray ionization (DESI) imaging mass spectrometry. Direct DESI analysis of the untreated leaves was not possible despite a significant content of hydroxynitrile glucosides known to reside in the epidermis of the leaves. Instead, the epidermis was stripped off the leaves, thus allowing direct DESI imaging to be performed on the back of the epidermis. Furthermore, indirect DESI imaging was performed by making imprints in porous Teflon of the intact leaves as well as of the stripped epidermis. The DESI images reveal accumulation of hydroxynitrile glucosides in the leaf epidermis, homogeneously distributed throughout the surface. The indirect DESI approach enables relative quantitation, confirming variations of hydroxynitrile glucosides content in primary leaves of three different cultivars of barley seedlings. The study presents an example of how to overcome the morphological barriers from the plant surface and perform rapid and repeatable DESI imaging. In addition, a comparison is made of direct and indirect DESI imaging, contributing to the characterization of the recently developed method of indirect DESI imaging of plant material via porous Teflon imprints.  相似文献   

11.
The S-nitrosylation of proteins is involved in the trafficking of nitric oxide (NO) in intra- and extracellular milieus. To establish a mass spectrometric method for identifying this post-translational modification of proteins, a synthetic peptide and transthyretin were S-nitrosylated in vitro and analyzed by electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The intact molecular ion species of nitrosylated compounds was identified in the ESI mass spectrum without elimination of the NO group. However, the labile nature of the S-NO bond was evident when the in-source fragmentation efficiently generated [M + H - 30](+) ions. The decomposition was prominent for multiply charged transthyretin ions with high charge states under ordinary ESI conditions, indicating that the application of minimum nozzle potentials was essential for delineating the stoichiometry of nitrosylation in proteins. With MALDI, the S-NO bond cleavage occurred during the ionization process, and the subsequent reduction generated [M + H - 29](+) ions.  相似文献   

12.
Ambient desorption/ionization mass spectrometry (MS) has gained growing interest during the last decade due to its high analytical performance and yet simplicity. Here, one of the recently developed ambient desorption/ionization MS sources, the flowing atmospheric‐pressure afterglow (FAPA) source, was investigated in detail regarding background ions and typical ionization patterns in the positive as well as the negative ion mode for a variety of compound classes, comprising alkanes, alcohols, aldehydes, ketones, carboxylic acids, organic peroxides and alkaloids. A broad range of signals for adducts and losses was found, besides the usually emphasized detection of quasimolecular ions, i.e. [M + H]+ and [M ? H]? in the positive and the negative mode, respectively. It was found that FAPA–MS is best suited for polar analytes containing nitrogen and/or oxygen functionalities, e.g. carboxylic acids, with low molecular weights and relatively high vapor pressures. In addition, the source was used in proof‐of‐principle studies, illustrating the capabilities and limitations of the technique: Firstly, traces of cocaine were detected and unambiguously identified on euro banknotes using FAPA ionization in combination with tandem MS, suggesting a correlation between cocaine abundance and age of the banknote. Secondly, FAPA–MS was used for the identification of acidic marker compounds in organic aerosol samples, indicating yet‐undiscovered matrix and sample surface effects of ionization pathways in the afterglow region. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
This report focuses on the heterogeneous distribution of small molecules (e.g. metabolites) within dry deposits of suspensions and solutions of inorganic and organic compounds with implications for chemical analysis of small molecules by laser desorption/ionization (LDI) mass spectrometry (MS). Taking advantage of the imaging capabilities of a modern mass spectrometer, we have investigated the occurrence of “coffee rings” in matrix-assisted laser desorption/ionization (MALDI) and surface-assisted laser desorption/ionization (SALDI) sample spots. It is seen that the “coffee-ring effect” in MALDI/SALDI samples can be both beneficial and disadvantageous. For example, formation of the coffee rings gives rise to heterogeneous distribution of analytes and matrices, thus compromising analytical performance and reproducibility of the mass spectrometric analysis. On the other hand, the coffee-ring effect can also be advantageous because it enables partial separation of analytes from some of the interfering molecules present in the sample. We report a “hidden coffee-ring effect” where under certain conditions the sample/matrix deposit appears relatively homogeneous when inspected by optical microscopy. Even in such cases, hidden coffee rings can still be found by implementing the MALDI-MS imaging technique. We have also found that to some extent, the coffee-ring effect can be suppressed during SALDI sample preparation.  相似文献   

14.
A single gas‐assisted electrospray ion source developed for ambient mass spectrometry is introduced in this paper. Simultaneous self‐aspiration and electrospray could be achieved by using a constant sheath gas flow supplied from a mini air pump. A gas dynamic study of the spray module is carried out for structural optimization. The entire device exhibits a simplified design and has been systematically characterized through both simulated and experimental investigations. According to the results, the ion source exhibited satisfactory stability and the ability for quantitative operation in routine electrospray ionization mass spectrometry. Furthermore, the ion source can be operated as a desorption electrospray ionization source to perform direct desorption/ionization of the solid samples. The versatile source described here appears to provide a practical approach to perform ambient mass spectrometry analysis with unrestricted sampling operation, and the extensive gas dynamic studies together with the experimental characterization are believed to be helpful in building self‐aspirating spray devices. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

15.
Desorption ElectroSpray Ionization (DESI) ‐ Orbitrap Mass Spectrometry (MS) was evaluated as a new tool for the characterization of various industrial synthetic polymers (poly(ethylene glycol), poly(propylene glycol), poly(methylmethacrylate), poly(dimethylsiloxane)) and copolymers, with masses ranging from 500 g.mol−1 up to more than 20 000 g.mol−1. Satisfying results in terms of signal stability and sensitivity were obtained from hydrophobic surfaces (HTC Prosolia) with a mixture water/methanol (10/90) as spray solvent in the presence of sodium salt. Taking into account the formation of multiplied charged species by DESI‐MS, a strategy based on the use of a deconvolution software followed by the automatic assignment of the ions was described allowing the rapid determination of Mn, Mw and PDI values. DESI‐Orbitrap MS results were compared to those obtained from matrix‐assisted laser desorption/ionization‐ time‐of‐flight MS and gel permeation chromatography. An application of DESI‐Orbitrap MS for the detection and identification of polymers directly from cosmetics was described. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
Continuous flow infrared matrix‐assisted laser desorption electrospray ionization (CF IR MALDESI) mass spectrometry was demonstrated for the on‐line analysis of liquid samples. Samples in aqueous solution were flowed through a 50 µm i.d. fused‐silica capillary at a flow rate of 1–6 µL/min. As analyte aqueous solution flowed through the capillary, a liquid sample bead formed at the capillary tip. A pulsed infrared optical parametric oscillator (OPO) laser with wavelength of 2.94 µm and a 20 Hz repetition rate was focused onto the capillary tip for sample desorption and ablation. The plume of ejected sample was entrained in an electrospray to form ions by MALDESI. The resulting ions were sampled into an ion trap mass spectrometer for analysis. Using CF IR MALDESI, several chemical and biochemical reactions were monitored on‐line: the chelation of 1,10‐phenanthroline with iron(II), insulin denaturation with 1,4‐dithiothreitol, and tryptic digestion of cytochrome c. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
Betaines belong to the naturally occurring osmoprotectants or compatible solutes present in a variety of plants, animals and microorganisms. In recent years, metabolomic techniques have been emerging as a fundamental tool for biologists because the constellation of these molecules and their relative proportions provide with information about the actual biochemical condition of a biological system. Therefore, identification and characterization of biologically important betaines are crucial, especially for metabolomic studies. Most of the natural betaines are derived from amino acids and related homologues. Although, theoretically, all the amino acids can be converted to corresponding betaines by simple methylation of the amine group, only a few of the amino acid‐derived betaines were fully characterized in the literature. Here, we report a combined electrospray ionization tandem and high‐resolution mass spectrometry study of all the betaines derived from amino acids, including the isomeric betaines. The decomposition pathway of protonated, sodiated and potassiated molecule ions that enable unambiguous characterization of the betaines including the isomeric betaines and overlapping ionic species of different betaines is distinctive. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
Despite cyanoacrylate fuming being widely used in the forensic science field, its mechanism is not well understood. In this study, matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry is used to study latent fingerprints that have been cyanoacrylate fumed in an attempt to gain insight into the fuming mechanism. In the negative mode mass spectrometry data, four compounds related to the polymerization of cyanoacrylate are identified and their structures are determined from accurate mass and MS/MS. A mechanism is proposed for the formation of these compounds that are regarded as intermediates in the polymerization reaction. In addition, based on the fuming of standard endogenous compounds, we suggest that fatty acids and amino acids are the major catalytic nucleophiles that initiate the polymerization reactions.  相似文献   

19.
20.
Reactive intermediates play key roles for reaction mechanism elucidation. A suitable tool for identifying the key intermediates is crucial and highly desirable. In this study, surface desorption dielectric‐barrier discharge ionization (reactive SDDBDI) was developed for characterization of the reactive intermediates. In reactive SDDBDI, the plasma is doped with a reagent before the plasma ions are directed at a cover slip surface bearing another analyte. Different from SDDBDI, reactive SDDBDI can be used both as an ambient ionization source and as a means to produce reagent ions for ambient ion/molecule reactions. The online derivation of 4‐aminophenol with trifluoroacetic anhydride demonstrated that reactive SDDBDI can be used for chemical analysis where improved specificity or sensitivity is required. The utility of this approach for real‐time detection of reactive intermediate was demonstrated by the Schiff‐base and Eberlin reactions. The formed intermediates and products could be readily detected and identified by tandem mass spectrometry. These results indicate that reactive SDDBDI can be used to generate reagent ions that undergo ion/molecule reactions in the open air with an analyte at condensed phase on a surface. Reactive SDDBDI has high‐efficiency ion transmission and high MS sensitivity. It is thus a potential tool to perform ambient ion/molecule reactions and detect reactive intermediates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号