首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
A simple, fast and direct method is presented for detecting traces of solid explosives on cotton swabs or in particulate samples: ions are transferred into a mass spectrometer after thermal desorption and corona discharge chemical ionization in ambient air; specificity is enhanced using ambient ion/molecule reactions or by conventional tandem mass spectrometry.  相似文献   

2.
Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last 9 years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification. Difficulties with ion identification can be solved through modified instrumentation, including accurate-mass or MS/MS capabilities for analyte identification. More difficult problems include quantification because of the ambient nature of the sampling process. To characterize and improve sample volatilization, ionization, and introduction into the mass spectrometer interface, a method of visualizing mass transport into the mass spectrometer is needed. Schlieren imaging is a well-established technique that renders small changes in refractive index visible. Here, schlieren imaging was used to visualize helium flow from a plasma-based ADI-MS source into a mass spectrometer while ion signals were recorded. Optimal sample positions for melting-point capillary and transmission-mode (stainless steel mesh) introduction were found to be near (within 1 mm of) the mass spectrometer inlet. Additionally, the orientation of the sampled surface plays a significant role. More efficient mass transport resulted for analyte deposits directly facing the MS inlet. Different surfaces (glass slide and rough surface) were also examined; for both it was found that the optimal position is immediately beneath the MS inlet.
Figure
?  相似文献   

3.
We have designed and constructed an atmospheric pressure laser desorption/chemical ionization (AP-LD/CI) source that utilizes a laser pulse to desorb intact neutral molecules, followed by chemical ionization via reagent ions produced by a corona discharge. This source employs a heated capillary atmospheric pressure inlet coupled to a quadrupole ion trap mass spectrometer and allows sampling under normal ambient air conditions. Preliminary results demonstrate that this technique provides approximately 150-fold increase in analyte ions compared to the ion population generated by atmospheric pressure infrared matrix-assisted laser desorption/ionization (AP-IR-MALDI).  相似文献   

4.
The development of a new configuration of chemical ionization (CI)‐based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub‐ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high‐voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can also be analyzed directly by approaching the sample to the sampling nozzle. When combined with heated nitrogen or other desorption methods, its application can also be extended to non‐volatile compounds, and the consumption for helium can be kept minimum solely for maintaining the stable discharge and gas phase ionization. Applications to non‐proximate sample analysis, direct determination of active ingredients in drug tablets and the detection of trace explosive such as hexamethylene triperoxide diamine are demonstrated. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
This work presents the unique features of a novel configuration of a synchronized dual-polarity time-of-flight mass spectrometer for comprehensive surface imaging. Mass spectrometry imaging of surface samples covering positive and negative ion modes is difficult due to rapid signal depletion. This limitation is overcome here by dual-polarity time-of-flight mass spectrometry (DP-TOFMS) via two separate TOF mass analyzers that are installed above a sample surface. The new instrument eliminates the polarity bias characteristic of most mass spectrometers, which is important for the analysis of samples with diverse physical and chemical properties. The experimental results show for the first time that the spatial distribution of positive and negative ions of various photolabile samples can be distinguished, including pigments and conventional matrix-assisted laser desorption/ionization samples. The different positive and negative ion distributions suggest that accurate quantitative information can only be obtained when the entire sample region is examined by DP-TOFMS, which was unfeasible in the past. Such a comprehensive diagnostic method is essential for the molecular imaging of trace compositions in delicate biological tissues, as demonstrated here with a Phyllanthus urinaria leaf that only produced ion signals in the first examination and not in the subsequent measurements.  相似文献   

6.
Rezenom YH  Dong J  Murray KK 《The Analyst》2008,133(2):226-232
We have used an infrared laser for desorption of material and ionization by interaction with electrosprayed solvent. Infrared laser-assisted desorption electrospray ionization (IR LADESI) mass spectrometry was used for the direct analysis of water-containing samples under ambient conditions. An ion trap mass spectrometer was modified to include a pulsed Er:YAG laser at 2.94 microm wavelength coupled into a germanium oxide optical fiber for desorption at atmospheric pressure and a nanoelectrospray source for ionization. Analytes in aqueous solution were placed on a stainless steel target and irradiated with the pulsed IR laser. Material desorbed and ablated from the target was ionized by a continuous stream of charged droplets from the electrosprayed solvent. Peptide and protein samples analyzed using this method yield mass spectra similar to those obtained by conventional electrospray. Blood and urine were analyzed without sample pretreatment to demonstrate the capability of IR LADESI for direct analysis of biological fluids. Pharmaceutical products were also directly analyzed. Finally, the role of water as a matrix in the IR LADESI process is discussed.  相似文献   

7.
The efficiency of desorption/ionization becomes more critical as the sampled surface area decreases. Desorption electrospray and desorption nanoelectrospray belong to ambient ionizations and enable direct surface analysis including mass spectrometric imaging. Lateral resolution in tens of micrometers was demonstrated for desorption nanoelectrospray previously, but sensitivity of the surface scan can be an issue. For desorption electrospray, the drag force in the source is driven by the flow of used gases and vacuum suction. Ion signal intensity can be improved by controlling the nebulizing gas flow rate or auxiliary pumping of a closed compartment in front of the mass spectrometer inlet. Because nanoelectrospray generates charged droplets without the assistance of a nebulizing gas, only vacuum suction drives the gas flow. In this study, the effect of pressure drop between the atmospheric and evacuated region of a mass spectrometer on the ion signal intensity was investigated for desorption nanoelectrospray. A modification of the commercial inlet was designed. An auxiliary pump was directly connected to an inner compartment of the modified mass spectrometer inlet through a needle valve that enabled the regulation of the reduced pressure. Adjustment of the pressure drop significantly increased signal intensity (more than one order of magnitude in some cases). To a lesser extent, the temperature of a heated capillary (an integral part of the inlet) also influenced the signal intensity. The applicability of desorption nanoelectrospray equipped with pressure regulation was demonstrated by the analysis of synthetic cathinones or a pill of paracetamol. Because pressure in the inlet depends on the diameters of orifices and the power of vacuum systems of mass spectrometers, the effect of the pressure regulation can be different for different instruments. Nevertheless, the presented results confirmed the importance of pressure drop‐driven transport for desorption nanoelectrospray efficiency and can encourage its new applications.  相似文献   

8.
Emary WB  Isern-Flecha I  Wood KV  Ridley TY  Cooks RG 《Talanta》1986,33(12):1001-1007
The coupling of a caesium ion source to a triple quadrupole mass spectrometer is described. The potential of this combination for examining thermally labile, non-volatile molecules, such as thiamine hydrochloride, is examined. Emphasis is placed on the advantages the various scanning modes of tandem mass spectrometry provide in ion structure elucidation and the investigation of desorption ionization mechanisms. Use of the caesium ion source for desorption of neutral molecules which are chemically ionized by an auxiliary gas is demonstrated. This procedure may be especially useful for examining non-volatile, non-ionic samples.  相似文献   

9.
Ion source pressure plays a significant role in the process of ionization and the subsequent ion transmission inside a mass spectrometer. Pressurizing the ion source to a gas pressure greater than atmospheric pressure is a relatively new approach that aims to further improve the performance of atmospheric pressure ionization sources. For example, under a super‐atmospheric pressure environment, a stable electrospray can be sustained for liquid with high surface tension such as pure water, because of the suppression of electric discharge. Even for nano‐electrospray ionization (nano‐ESI), which is known to work with aqueous solution, its stability and sensitivity can also be enhanced, particularly in the negative mode when the ion source is pressurized. A brief review on the development of super‐atmospheric pressure ion sources, including high‐pressure electrospray, field desorption and superheated ESI, and the strategies to interface these ion sources to a mass spectrometer will be given. Using a recent ESI prototype with an operating temperature at 220 °C under 27 atm, we also demonstrate that it is possible to achieve an online Asp‐specific protein digestion analysis in which the whole processes of digestion, ionization and MS acquisition could be completed on the order of a few seconds. This method is fast, and the reaction can even be monitored on a near‐real‐time basis. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
质谱作为一种具有高准确度、高灵敏度、高选择性的检测仪器,在公共安全领域有着重要的应用前景.公共安全领域的需求主要涉及毒品、毒物、爆炸物等化学物质的现场快速检测,因其影响广泛,检测结果需非常准确.作为实验室分析仪器,质谱的准确性和速度能满足公共安全的应用需求,但作为现场快速检测的仪器仍需要一定改进.现场快速检测一方面要求...  相似文献   

11.
Ambient mass spectrometry has attracted substantial attention in recent years. Among ambient ionization methods, thermal desorption ionization stands out because of two attributes: (1) simplicity, rendering the technique suitable for in-field applications, and (2) ability to couple with a variety of gas-phase ionization methods thereby broadening the range of molecules that can be analyzed with this method. Here, we report on improving the performance of a direct analysis in real time (DART) source by implementing atmospheric pressure photoionization (APPI) downstream of the desorption region. At identical desorption and ion sampling conditions, APPI leads to detection of radical molecular ions from non-polar compounds that are absent from the spectra generated by DART alone. Moreover, a factor of 3–5 improvement in sensitivity is observed using APPI for positive ions commonly detected by DART and DART-APPI. Using helium and nitrogen as desorption gases, APPI shows identical performance regardless of desorption gas type. In contrast, a dramatic decrease in sensitivity is observed for DART operated with nitrogen compared to DART with helium. Comparable performance for DART and DART-APPI are observed in negative ion mode, although both show a drastic improvement in the absence of the Vapur interface. This interface creates a differentially pumped chamber prior to inlet of the mass spectrometer and reduces the mass spectrometer gas load when helium is used as desorption gas.  相似文献   

12.
A single gas‐assisted electrospray ion source developed for ambient mass spectrometry is introduced in this paper. Simultaneous self‐aspiration and electrospray could be achieved by using a constant sheath gas flow supplied from a mini air pump. A gas dynamic study of the spray module is carried out for structural optimization. The entire device exhibits a simplified design and has been systematically characterized through both simulated and experimental investigations. According to the results, the ion source exhibited satisfactory stability and the ability for quantitative operation in routine electrospray ionization mass spectrometry. Furthermore, the ion source can be operated as a desorption electrospray ionization source to perform direct desorption/ionization of the solid samples. The versatile source described here appears to provide a practical approach to perform ambient mass spectrometry analysis with unrestricted sampling operation, and the extensive gas dynamic studies together with the experimental characterization are believed to be helpful in building self‐aspirating spray devices. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

13.
Sonic spray ionization is shown to create a supersonic cloud of charged droplets able to promote efficient desorption and ionization of drugs directly from the surfaces of commercial drug tablets at ambient conditions. Compared with desorption electrospray ionization (DESI), desorption sonic spray ionization (DeSSI) is advantageous since it uses neither heating nor high voltages at the spray capillary. DeSSI therefore provides a more friendly environment in which to perform ambient mass spectrometry (MS). DeSSI-MS is herein evaluated for the analysis of drug tablets, and found to be, in general, as sensitive as DESI-MS. The (high) voltage-free DeSSI method provides, however, cleaner mass spectra with less abundant solvent cluster ions and with enough abundant analyte signal for tandem mass spectrometry (MS/MS). These features may therefore facilitate the DeSSI-MS detection of low molar mass components or impurities, or both. The higher-velocity supersonic DeSSI spray also facilitates matrix penetration thus providing more homogenous sampling and longer lasting ion signals.  相似文献   

14.
This report describes a new high-resolution linear time-of-flight mass spectrometer that has been constructed at this institute. The instrument is used for investigations of both direct and matrix-assisted laser desorption/ionization of large molecules. A unique feature of this new instrument is the incorporation of a 10-cm postsource pulse-focusing region for enhancing the resolution of the detected ion signals. This technique can correct for both high initial ion translational energies and long durations of ion formation and is expected to be particularly well suited for laser desorption/ionization applications. Results of calculations are presented to illustrate the gains in mass resolution that may be expected for a variety of ion formation conditions. In addition, initial experimental results are presented that demonstrate the capability of this new instrument to produce high-resolution ion signals. Signals with mass resolutions as high as 2750 (full width at half maximum) have been obtained for both direct and matrix-assisted laser desorption/ionization signals.  相似文献   

15.
An atmospheric pressure ionization source based on desorption electrospray ionization technology for a bench-top hybrid FTICR mass spectrometer is described. The ion source was characterized using low-molecular-weight-weight pharmaceutical samples. The dependences of signal intensities on various experimental parameters (solvent composition, surface temperature, spray voltage, etc.) were studied. Based on the results obtained, plausible mechanisms of desorption electrospray ionization for the analytes under the study are discussed.  相似文献   

16.
薛震  邱波  林广欣  赖丛芳  罗海 《化学进展》2008,20(4):594-601
本文介绍了一种新近发展起来的质谱离子化方法——解吸电喷雾电离(desorption electrospray ionization, DESI)及其最新研究进展。该方法首次于2004年提出后,由于其具有样品无需前处理就可以在常压条件下从各种载物表面直接分析固相,或凝固相样品等优势而得到了迅速的发展。本文描述了DESI的基本原理、离子源的结构和相关优化的参数,并对该离子化方法中所用的载物表面进行了总结。在实际应用方面,本文综述了DESI技术在常压气相化学反应产物监测,合成高聚物表征,爆炸物和化学战毒剂检测,以及在药品,生物代谢产物和生物组织表面分析方面的应用成果,同时对DESI的基础应用研究方向进行了分析和展望。  相似文献   

17.
The ionization mechanisms of several atmospheric pressure ion sources based on desorption and ionization of samples deposited on a surface were studied. Home‐built desorption electrospray ionization (DESI), laserspray ionization (LSI), and atmospheric pressure matrix‐assisted laser desorption/ionization (AP‐MALDI) sources were characterized using low‐molecular‐weight compounds, in particular fluorescent dyes. Detection of the desorbed and ionized species was performed by laser‐induced fluorescence and ion cyclotron resonance mass spectrometry. The dependences of the signal intensities on various experimental parameters were studied. The data obtained reveals common features, such as formation of solvated species and clusters in the ionization processes, in all of the techniques considered. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
本研究以721矿和745矿嗜酸性氧化亚铁硫杆菌为研究对象,采用常压化学电离质谱直接分析其代谢产物,分别考察了顶空采样( Headspace sampling)、界面采样( Interface sampling)和中性解吸采样( Neutral desorption sampling)3种进样方式对电离效果的影响。在优化条件下,常压化学电离质谱对微生物纯菌种和混合菌种的代谢产物均具有良好的分析能力,可根据获得的代谢产物指纹谱图结合主成分分析( PCA)方法和聚类分析( CA)方法区分2个放射性强弱不同区域共4类嗜酸性微生物样品,并对主要胺类、酯类等代谢成分进行串联质谱鉴定,为耐辐射微生物的相关研究提供了一种可借鉴的分析方法。  相似文献   

19.
Ambient mass spectrometry: bringing MS into the “real world”   总被引:1,自引:0,他引:1  
Mass spectrometry has recently undergone a second contemporary revolution with the introduction of a new group of desorption/ionization (DI) techniques known collectively as ambient mass spectrometry. Performed in an open atmosphere directly on samples in their natural environments or matrices, or by using auxiliary surfaces, ambient mass spectrometry (MS) has greatly simplified and increased the speed of MS analysis. Since its debut in 2004 there has been explosive growth in the applications and variants of ambient MS, and a very comprehensive set of techniques based on different desorption and ionization mechanisms is now available. Most types of molecules with a large range of masses and polarities can be ionized with great ease and simplicity with the outstanding combination of the speed, selectivity, and sensitivity of MS detection. This review describes and compares the basis of ionization and the concepts of the most promising ambient MS techniques known to date and illustrates, via typical analytical and bioanalytical applications, how ambient MS is helping to bring MS analysis deeper than ever into the “real world” open atmosphere environment—to wherever MS is needed.  相似文献   

20.
Electrospray droplet impact (EDI)/secondary ion mass spectrometry (SIMS) is a new desorption/ionization technique for mass spectrometry in which highly charged water clusters produced from atmospheric‐pressure electrospray are accelerated in vacuum by several kV and impact on the sample deposited on the metal substrate. In this study, we applied EDI/SIMS directly to fruits, such as bananas, strawberries, grapes and apples. The major components in the fruits – fructose, glucose, sucrose and organic acids – could be observed with strong signal intensities. EDI/SIMS was also applied to the analysis of different regions of strawberries and apples. Compared with matrix‐assisted laser desorption/ionization (MALDI), ion signals with lower background signals could be obtained, particularly for the low molecular weight analytes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号