首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
基于稀土Eu(Ⅲ)掺杂的类普鲁士蓝膜修饰的铂电极为工作电极,建立了测定羟考酮的毛细管电泳-电致化学发光分析方法。考察了检测电位、运行缓冲溶液的酸度及浓度、分离电压、进样条件等对电泳分离效果及检测灵敏度的影响。在最佳的实验条件下,羟考酮可在4 min内得到分离,其ECL强度值与羟考酮的质量浓度在7.0×10-2~7.0μg/mL和7.0~70.0μg/mL范围内呈良好的线性关系,检出限为4.2×10-2μg/mL(3σ),峰高和迁移时间的相对偏差分别为3.6%和0.48%(n=6)。方法用于兔血浆中羟考酮含量的检测,加标回收率在99.7%~101.0%之间。  相似文献   

2.
布比卡因是一种外科局部麻醉剂,使用过量会导致中枢神经系统和心脏血管系统中毒[1],可引起心脏停博.高效液相色谱和毛细管电泳(CE)[2]是该药常用的检测方法.  相似文献   

3.
Bao Y  Yang F  Yang X 《Electrophoresis》2011,32(12):1515-1521
A CE‐electrochemiluminescence(CE‐ECL) detection system, CE/tris(2,2′‐bipyridyl) ruthenium(II)ECL with ionic liquid, was established for the determination of diester‐diterpenoid aconitum alkaloids (aconitine (AC), mesaconitine (MA) and hypaconitine (HA)) in traditional Chinese herbal medicine. Running buffer containing 25 mM borax‐20 mM 1‐ethyl‐3‐methylimidazolium tetrafluoroborate at pH 9.15 was used, which resulted in significant changes in separation and obvious enhancement in ECL intensity for AC, MA and HA with similar structures. End‐column detection was achieved in 50 mM phosphate buffer with 5 mM (pH 9.15) at applied detection voltage of 1.20 V when the distance between the Pt working electrode and outlet of capillary (50 cm×25 μm id) was set at 150 μm. One single quantitative analysis of three alkaloids was achieved at a separation voltage of 15 kV within 10 min. Moreover, two extraction processes (ethanol extraction and ethyl ether extraction after basification) were investigated. The result showed that ethanol extraction process has higher extraction efficiency than ethyl ether extraction process. Under the optimized conditions, the detection limits of AC, MA and HA were 5.62×10?8, 2.78×10?8 and 3.50×10?9 mol/L (S/N=3), respectively. The method was successfully applied to determine the amounts of AC, MA and HA in the aconitum herbal samples.  相似文献   

4.
In the present study, we propose the first HPLC method coupled to postcolumn derivatization for the determination of rimantadine in human urine samples. The analyte and amantadine (internal standard) were isocratically separated using an RP monolithic stationary phase (100 × 4.6 mm id) with a mobile phase consisting of CH3OH/phosphate buffer (25 mmol/L, pH 3.0) at a volume ratio of 50:50. Postcolumn derivatization involved on‐line reaction with o‐phthalaldehyde (20 mmol/L) and N‐acetyl‐cysteine (5 mmol/L) at alkaline medium (100 mmol/L borate pH 11.0). Spectrofluorimetric detection at λex/λem = 340/455 nm enabled the selective and sensitive determination of rimantadine in urine samples at a range of 50–500 ng/mL with an LOD of 5 ng/mL. Human urine samples were analyzed successfully after SPE using hydrophilic‐lipophilic balanced RP cartridges (30 mg/mL, Oasis HLB). Recoveries ranged between 89.7 and 102.7%.  相似文献   

5.
M Zhou  Y Li  C Liu  Y Ma  J Mi  S Wang 《Electrophoresis》2012,33(16):2577-2583
A CE electrochemiluminescence (CE-ECL) method for simultaneous determination of lappaconitine hydrobromide (LH) and isopropiram fumarate (IF) has been first established, with a chemically modified platinum electrode by europium (III)-doped Prussian blue analogue film as a working electrode. The conditions for CE separation and ECL detection are discussed and optimized in detail. It has been proved that 20 mmol/L phosphate buffer (pH 8.5) containing 5% (v/v) ACN and 0.17 mol/L SDS could achieve the most favorable resolution, and the high sensitivity of detection was obtained by maintaining the detection potential at 1.23 V. Under optimized conditions, a baseline separation for the two analytes was achieved within 6 min, and the standard curves were linear in the range of 1.0×10(-7) ~ 5.0 × 10(-5) g/mL for LH and 4.0 × 10(-8) ~ 1.0 × 10(-5) g/mL for IF with the detection limits (3σ) of 6.6 × 10(-8) g/mL for LH and 3.7 × 10(-8) g/mL for IF, respectively. The precisions of intra- and interday measurements for LH and IF were less than 4.21 and 2.61%, respectively. The applicability of the proposed method was illustrated in the determination of LH and IF in rabbit plasma with recoveries between 95.6 and 103.0%.  相似文献   

6.
Ying Gao  Yuanhong Xu  Jing Li 《Talanta》2009,80(2):448-453
CE/Ru(bpy)32+ electrochemiluminescence (ECL) system with the assistance of ionic liquids (ILs) was successfully established for sensitive determination of verticine and verticinone in Bulbus Fritillariae for the first time. Migration behavior of alkaloid largely relies on the hydrogen bonding interactions between alkyl imidazolium cations in ILs and the alkaloids. Running buffer containing 40 mmol/L 1-butyl-3-methylimidazolium tetrafluoroborate (BMImBF4) IL-8 mmol/L phosphate resulted in significant changes in separation selectivity for alkaloids with similar structures. The highest sensitivity of the detection was obtained by maintaining the detection potential at 1.2 V. Under the optimized conditions, relative standard derivations of the ECL intensity and the migration time were 3.27 and 2.84% for verticine and 4.42 and 1.69% for verticinone, respectively. The standard curves were linear between 1 × 10−8 and 1 × 10−6 mol/L for verticine and between 5 × 10−8 and 1 × 10−6 mol/L for verticinone, respectively. Detection limits of 1.25 × 10−10 mol/L for verticine and 1 × 10−10 mol/L for verticinone were obtained (S/N = 3). Developed method was successfully applied to determine the amounts of alkaloids in Bulbus Fritillariae.  相似文献   

7.
A simple, rapid and sensitive CE method coupled with electrochemiluminescence (ECL) detection for direct analysis of ibandronate (IBAN) has been developed. Using a buffer solution of 20 mM sodium phosphate (pH 9.0) and a voltage of 13.5 kV, separation of IBAN in a 30‐cm length capillary was achieved in 3 min. ECL detection was performed with an indium tin oxide working electrode bias at 1.6 V (versus a Pt wire reference) in a 200‐mM sodium phosphate buffer (pH 8.0) containing 3.5 mM Ru(bpy)32+ (where bpy=2,2′‐bipyridyl). Derivatization of IBAN prior to CE‐ECL analysis was not needed. Linear correlation (r=0.9992, n=7) between ECL intensity and analyte concentration was obtained in the range of 0.25–50 μM IBAN. The LOD of IBAN in water was 0.08 μM. The developed method was applied to the analysis of IBAN in a drug formulation and human urine sample. SPE using magnetic Fe3O4@Al2O3 nanoparticles as the extraction phase was employed to pretreat the urine sample before CE‐ECL analysis. The linear range was 0.2–12.0 μM IBAN in human urine (r=0.9974, n=6). The LOD of IBAN in urine was 0.06 μM. Total analysis time including sample preparation was <1 h.  相似文献   

8.
《Electroanalysis》2005,17(18):1675-1680
We developed a sensitive, simple and low cost method to determine methimazole based on capillary electrophoresis with electrochemical detection (CE‐EC) at a carbon fiber microdisk electrode (CFE). We investigated the effects of detection potential, the concentration and pH value of the phosphate buffer, and injection time as well as separation voltage on the detection of methimazole. Under the optimized conditions: the detection potential at 1.30 V, 10 mmol/L phosphate buffer (pH 7.0), injection time 30 s at a height of 20 centimeter and separation voltage at 15 kV, the linear range was obtained from 1.0×10?7 to 2.0×10?4 mol/L, covering 3 orders of magnitude with a correlation coefficient of 0.9995. The LOD (S/N=3) obtained was 5.0×10?8 mol/L. The RSD of migration time and peak current for 2.0×10?4 mol/L methimazole was 1.04% and 1.54% (n=10), respectively. The method was also used to analyze methimazole tablets and human urine sample.  相似文献   

9.
A novel method of CE coupled with dual electrochemical detection has been developed for the determination of pathological metabolites of phenylalanine in urine samples. Factors influencing the separation and detection were examined and optimized. Five aromatic acid metabolites and a major coexisting interfering compound uric acid could be well separated within 23 min at a separation voltage of 16 kV using a 35 mmol/L SDS/60 mmol/L H3BO3‐Na2B4O7 running buffer (pH 8.2). Highly linear response was obtained for these five biomarker compounds over three orders of magnitude with detection limits ranging from 6.6 to 0.064 μg/mL (S/N=3). The average recovery and RSD were within the range of 92.6–121.0 and 1.0–12.0%, respectively. The proposed method has been used to detect the unconjugated aromatic acids simultaneously in urine samples with the advantages of obtaining more information about target analytes and avoiding redundant measurements and high assay cost, thus could find potential applications involving assays of biomarker compounds for the purpose of fast diagnose of some metabolic diseases including phenylketonuria.  相似文献   

10.
A sensitive, simple and reproducible method was developed for preconcentration and determination of trimipramine (TPM) enantiomers in biological samples using electromembrane extraction combined with cyclodextrin‐modified capillary electrophoresis (CE). During the extraction, TPM enantiomers migrated from a 5 mL sample solution through a thin layer of 2‐nitrophenyl octyl ether NPOE immobilized in the pores of a hollow fiber, and into a 20 μL acidic aqueous acceptor phase presented inside the lumen of the fiber. A Box–Behnken design and the response surface methodology (RSM) were used for the optimization of different variables on extraction efficiency. Optimized extraction conditions were: NPOE as supported liquid membrane, inter‐electrode distance of 5 mm, stirring rate of 1000 rpm, 51 V potential difference, 34 min as the extraction time, acceptor phase pH 1.0 and donor phase pH 4.5. Then, the extract was analyzed using optimized cyclodextrin (CD)‐modified CE method for the separation of TPM enantiomers. Best results were achieved using 100 mM phosphate running buffer (pH 2.0) containing 10 mM α‐CD as the chiral selector, applied voltage of 18 kV and 20°C. The range of quantitation for both enantiomers was 20–500 ng/mL. The method was very reproducible so that intra‐ and interday RSDs (n=6) were <6%. The limits of quantitation and detection for both enantiomers were 20 and 7 ng/mL, respectively. Finally, this method was successfully applied to determine the concentration of TPM enantiomers in plasma and urine samples without any pre‐treatment.  相似文献   

11.
In the current work, two eco‐friendly analytical methods based on capillary electrophoresis (CE) and reversed phase liquid chromatography (RPLC) were developed for simultaneous determination of the most commonly used anticancer drugs for Hodgkin's disease: methotrexate (MTX), vinblastine, chlorambucil and dacarbazine. A background electrolyte (BGE) of 12.5 mmol/L phosphate buffer at pH 7.4 and 0.1 µmol/L 1‐butyl‐3‐methyl imidazolium bromide (BMImBr) ionic liquid (IL) was used for CE measurements at 250 nm detection wavelength, 20 kV applied voltage and 25 °C. The rinsing protocol was significantly improved to reduce the adsorption of IL on the interior surface of capillary. Moreover, RPLC method was developed on α‐1‐acid glycoprotein (AGP) column. Mobile phase was 10 mmol/L phosphate buffer at pH 6.0 (100% v/v) and flow rate at 0.1 mL/min. As AGP is a chiral column, it was successfully separated l ‐MTX from its enantiomer impurity d ‐MTX. Good linearity of quantitative analysis was achieved with coefficients of determinations (r2) >0.995. The stability of drugs measurements was investigated with adequate recoveries up to 24 h storage time under ambient temperature. The limits of detection were <50 and 90 ng/mL by CE and RPLC, respectively. The using of short‐chain IL as an additive in BGE achieved 600‐fold sensitivity enhancement compared with conventional Capillary Zone Electrophoresis (CZE). Therefore, for the first time, the proposed methods were successfully applied to determine simultaneously the analytes in human plasma and urine samples at clinically relevant concentrations with fast and simple pretreatments. Developed IL‐assisted CE and RPLC methods were also applied to measure MTX levels in patients’ samples over time. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

12.
Liu J  Yang X  Wang E 《Electrophoresis》2003,24(18):3131-3138
Capillary electrophoresis (CE) with tris(2,2'-bipyridyl) ruthenium (II) (Ru(bpy)3(2+)) electrochemiluminescence (ECL) detection technique was developed for the analysis of four polyamines (putrescine (Put), cadaverine (Cad), spermidine (Spd), and spermine (Spm)) analysis. The four polyamines contain different amine groups, which have different ECL activity. There are several parameters which influence the resolution and ECL peak intensities, including the buffer pH and concentrations, separation voltage, sample injection, electrode materials, and Ru(bpy)3(2+) concentrations. Polyamines are separated by capillary zone electrophoresis in an uncoated fused-silica capillary (50 cmx25 micro m (ID) filled with acidic phosphate buffer (200 mmol/L phosphate, pH 2.0) - 1mol/L phosphoric acid (9:1 v/v) and a separation voltage of 5 kV (25 micro A), with end-column Ru(bpy)3(2+) ECL detection. A 5 mmol/L Ru(bpy)3(2+) solution plus 200 mmol/L phosphate buffer (pH 11.0) is added into the reagent reservoir. The calibration curve is linear over a concentration range of two or three orders of magnitude for the polyamines. The analysis time is less than 25 min. Detection limits for Put and Cad are 1.9x10(-7) mol/L and 7.6x10(-9) mol/L for Spd and Spm, respectively. Intraday and interday relative standard deviations of ECL peak intensities are less than 8%. The main advantages of this CE-ECL detection technique for polyamines analysis presented herein are the omission of chemical derivatization of the analytes and the high selectivity.  相似文献   

13.
The fast separation capability of a novel miniaturized capillary electrophoresis with an amperometric detection (μCE‐AD) system was demonstrated by determining clenbuterol and salbutamol in real samples. The effects of several factors such as the acidity and concentration of the running buffer, the separation voltage, the applied potential and the injection time on CE‐AD were examined and optimized. Under the optimum conditions, the two β‐agonists could be baseline separated within 60 s at a separation voltage of 2 kV in a 90 mmol/L H3BO3‐Na2B4O7 running buffer (pH 7.4), which was not interfered by ascorbic acid and uric acid. Highly linear response was obtained for above compounds over three orders of magnitude with detection limits ranging from 1.20×10?7 to 6.50×10?8 mol/L (S/N=3). This method was successfully used in the analysis of feed and meat products with relatively simple extraction procedures.  相似文献   

14.
李旭菲  杨燕英  周考文 《色谱》2012,30(9):938-942
建立了同时检测氯丙嗪、异丙嗪及其主要代谢物的毛细管电泳电致化学发光新方法。最佳实验条件为: 检测电位1.20 V,钌联吡啶浓度5 mmol/L,检测池磷酸缓冲溶液40 mmol/L (pH 6.5),分离磷酸缓冲溶液18 mmol/L (pH 4.8),进样电压11 kV,进样时间8 s,分离电压13.5 kV。方法的检出限(3σ)分别为氯丙嗪8.3×10~7 g/L、异丙嗪7.2×10~6 g/L、氯丙嗪亚砜1.9×10~5g/L和异丙嗪亚砜3.7×10~6g/L,各组分的电化学发光强度和迁移时间的相对标准偏差(RSD)分别不超过3%和1%。本方法具有简便、快速、灵敏、进样量少和不受共存物干扰等特点,可在不必预分离的情况下直接同时连续测定家犬尿样中的氯丙嗪、异丙嗪、氯丙嗪亚砜和异丙嗪亚砜。  相似文献   

15.
以稀土铕离子(Ⅲ)掺杂的类普鲁士蓝膜(Eu-PB)修饰铂电极为工作电极,采用毛细管电泳-电致化学发光法(CE-ECL)对土壤中的多抗霉素B进行检测.分别对毛细管电泳分离条件和电致化学发光检测条件进行优化,并探讨了体系产生电致化学发光的机理.在优化实验条件下,多抗霉素B可在4 min内得到分离,其ECL强度值与多抗霉素B...  相似文献   

16.
Xia Li  Derong Zhu  Tianyan You 《Electrophoresis》2011,32(16):2139-2147
CE coupled with dual electrochemical (EC) and electrochemiluminescence (ECL) detection was optimized for simultaneous analysis of six cardiovascular drugs (alprenolol, propafenone, acebutolol, verapamil, atenolol and metoprolol) via central composite design. Following this study, three critical electrophoretic factors governing the CE separation were investigated: Tris‐H3PO4 buffer concentration, buffer pH value and separation voltage. A modified chromatographic response was adopted for evaluating CE separation quality. Optimum conditions were achieved using Tris‐H3PO4 buffer 35.6 mM (pH 2.3) separated at 13.9 kV, which was employed experimentally and led to the successful simultaneous separation of the above six drugs. The good agreement of the chromatographic response was observed between predicted data and actual experimental results using these optimized conditions (RSD=3.75%). The proposed method was validated for linearity, repeatability and sensitivity, and subsequently successfully applied to determine six basic drugs in urine samples.  相似文献   

17.
We present a method for simultaneous determination of the aminopolycarboxylic acids DTPA, EDTA and NTA in dishwashing detergents, paper mill waters, and natural waters by capillary electrophoresis (CE). The complexing agents were examined as their copper(II) complexes and separated by conventional CE with reversed polarity of the applied voltage. The optimum separation conditions were established by varying the pH and phosphate and tetradecyltrimethylammonium bromide (TTAB) concentrations in the run buffer. The separations were carried out in a fused-silica capillary (61 cm×75 m i.d.) filled with phosphate buffer (80 mmol L–1, TTAB concentration 0.5 mmol L–1, pH 7.1, voltage –20 kV) using direct UV detection at 191 and 254 nm. With this CE method all the peaks in the electropherograms were properly separated, the calibration plots gave good correlation coefficients and all three complexing agents could be detected in less than 4 min. Linear calibration plots were obtained for CuDTPA, CuEDTA and CuNTA; limits of detection were 0.03 mmol L–1 for all complexing agents and recoveries for all tested samples were within the range 104±7%. Results obtained from dishwashing detergent samples were found to be reliable and comparable with those from HPLC (R2=0.989) and UV–Vis (R2=0.985) methods.  相似文献   

18.
The coupling of Ru(bpy)32+ based electrochemiluminescence (ECL) detection with capillary electrophoresis (CE) was developed for the simultaneous determination of the two major active ingredients (atropine and scopolamine) in Flos daturae. Parameters related to the separation and detection were discussed and optimized. It was proved that 20 mM phosphate buffer at pH 8.48 could achieve the most favorable resolution, and the high sensitivity of detection was obtained by maintaining the detection potential at 1.2 V. Under the optimized conditions: ECL detection at 1.2 V, 20 mM phosphate buffer at pH 8.48, 5 mM Ru(bpy)32+ and 50 mM phosphate buffer at pH 7.48 in the detection reservoir, detection limits of 5 × 10−8 mol/l for atropine and 1 × 10−6 mol/l for scopolamine were obtained. Relative standard derivations of the ECL intensity and the migration time were 5.16 and 0.71% for atropine and 5.07 and 1.22% for scopolamine, respectively. Developed method was successfully applied to determine the amounts of both alkaloids in Flos daturae. A baseline separation for atropine and scopolamine was achieved within 11 min.  相似文献   

19.
A novel, simple and sensitive method for the enantioseparation and determination of DL ‐tetrahydropalmatine (DL ‐THP) was developed using ACE in combination with partial filling technique and field‐amplified sample injection. A chiral selector, i.e. BSA, was used for the enantioseparation of DL ‐THP in ACE. Effects of BSA concentration, pH and separation voltage on the effectiveness of the enantiomer separation were evaluated. In an optimal condition, D ‐ and L ‐THP were completely enantio‐separated in less than 9 min by partially filling an electrophoretic capillary with 50 μmol/L BSA (50 mbar, 100 s) and carrying out an electrophoresis with 20 mmol/L phosphate buffer (pH 7.4) at 15 kV. The sensitivity was further improved by making use of field‐amplified sample injection to lower the LOD (defined as S/N=3) down to 6 ng/mL. Real samples were also tested and promising results for the determination of DL ‐THP enantiomers were obtained.  相似文献   

20.
We report the development and validation of a stability‐indicating reversed‐phase high‐performance liquid chromatography method with precolumn derivatization for the separation and identification of the impurities of ripasudil hydrochloride hydrate, a novel protein kinase inhibitor. 2,3,4,6‐Tetra‐O‐acetyl‐β‐d ‐glucopyranosyl isothiocyanate was chosen as the derivatizing reagent and triethylamine was added as catalyst. 200 μL sample solution (1 mg/mL), 600 μL derivatizing reagent (1 mg/mL), and 200 μL triethylamine solution (1%, v/v) were mixed and reacted at 40°C for 30 min. The separation was achieved on an Inertsil C18 ODS‐3 (250 mm × 4.6 mm, 5 μm) column using mobile phases including 10 mmol monopotassium phosphate buffer (pH 3.0) and methanol in gradient mode. The column temperature was adjusted at 25°C and the flow rate at 1 mL/min. The detection was carried out at 220 nm. Different precolumn derivatization conditions as well as the high‐performance liquid chromatography conditions were optimized. Ripasudil hydrochloride hydrate and its four impurities were detected and quantitated, among which two new compounds were characterized. The proposed method was validated and proven to be selective, accurate, and precise and suitable for the quantitative analysis of ripasudil hydrochloride hydrate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号