共查询到20条相似文献,搜索用时 15 毫秒
1.
The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports. 相似文献
2.
Lee Chuin Chen Md. Matiur Rahman Kenzo Hiraoka 《Journal of mass spectrometry : JMS》2013,48(3):392-398
Super‐atmospheric pressure chemical ionization (APCI) mass spectrometry was performed using a commercial mass spectrometer by pressurizing the ion source with compressed air up to 7 atm. Similar to typical APCI source, reactant ions in the experiment were generated with corona discharge using a needle electrode. Although a higher needle potential was necessary to initiate the corona discharge, discharge current and detected ion signal were stable at all tested pressures. A Roots booster pump with variable pumping speed was installed between the evacuation port of the mass spectrometer and the original rough pumps to maintain a same pressure in the first pumping stage of the mass spectrometer regardless of ion source pressure. Measurement of gaseous methamphetamine and research department explosive showed an increase in ion intensity with the ion source pressure until an optimum pressure at around 4–5 atm. Beyond 5 atm, the ion intensity decreased with further increase of pressure, likely due to greater ion losses inside the ion transport capillary. For benzene, it was found that besides molecular ion and protonated species, ion due to [M + 2H]+ which was not so common in APCI, was also observed with high ion abundance under super‐atmospheric pressure condition. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
3.
Geyer R Peacock AD White DC Lytle C Van Berkel GJ 《Journal of mass spectrometry : JMS》2004,39(8):922-929
An atmospheric pressure photoionization (APPI) source and an atmospheric pressure chemical ionization (APCI) source were compared for the selective detection of microbial respiratory ubiquinone and menaquinone isoprenologues using tandem mass spectrometry. Ionization source- and compound mass-dependent parameters were optimized individually for both sources, using the available quinone standards. Detection levels for the two ion sources were determined with ubiquinone-6 (UQ6) and menaquinone-4 (MK4, vitamin K2) standards using flow injection analysis and selected reaction monitoring (SRM). With APPI the calculated lower limit of detection (LLOD) was 1.7 fmol microl(-1) for UQ6 and 2.2 fmol microl(-1) for MK4 at a signal-to-noise ratio of 3. These LLODs were at least three times lower than with APCI. The selectivity of detection afforded by SRM detection reduced complex mixture analysis to 3 min per sample by eliminating the need for chromatographic separations. The detection method was successfully applied to quinone quantification in a variety of environmental samples and cell cultures. Adequate amounts of respiratory quinones can be extracted and quantified from samples containing as low as 2 x 10(7) cells. 相似文献
4.
Organic peroxides such as the cumene hydroperoxide I (M(r) = 152 u), the di-tert-butyl peroxide II (M(r) = 146 u) and the tert-butyl peroxybenzoate III (M(r) = 194 u) were analyzed by atmospheric pressure chemical ionization mass spectrometry using a water-methanol mixture as solvent with a low flow-rate of mobile phase and unusual conditions of the source temperature (< or =50 degrees C) and probe temperature (70-200 degrees C). The mass spectra of these compounds show the formation of (i) an [M + H](+) ion (m/z 153) for the hydroperoxide I, (ii) a stable adduct [M + CH(3)OH(2)](+) ion (m/z 179) for the dialkyl peroxide II and (iii) several protonated adduct species such as protonated molecules (m/z 195) and different protonated adduct ions (m/z 227, 389 and 421) for the peroxyester III. Tandem mass spectrometric experiments, exact mass measurements and theoretical calculations were performed for characterize these gas-phase ionic species. Using the double-well energy potential model illustrating a gas-phase bimolecular reaction, three important factors are taken into account to propose a qualitative interpretation of peroxide behavior toward the CH(3)OH(2) (+), i.e. thermochemical parameters (DeltaHdegrees(reaction)) and two kinetic factors such as the capture constant of the initial stable ion-dipole and the magnitude of the rate constant of proton transfer reaction into the loose proton bond cluster. 相似文献
5.
Liying Ding Feng Hong Yongzhong Ouyang Rui Chen Shumin Zhou Huanwen Chen Xiang Fang 《Journal of mass spectrometry : JMS》2013,48(9):1042-1049
Molecular images of documents were obtained by sequentially scanning the surface of the document using desorption atmospheric pressure chemical ionization mass spectrometry (DAPCI‐MS), which was operated in either a gasless, solvent‐free or methanol vapor‐assisted mode. The decay process of the ink used for handwriting was monitored by following the signal intensities recorded by DAPCI‐MS. Handwritings made using four types of inks on four kinds of paper surfaces were tested. By studying the dynamic decay of the inks, DAPCI‐MS imaging differentiated a 10‐min old from two 4 h old samples. Non‐destructive forensic analysis of forged signatures either handwritten or computer‐assisted was achieved according to the difference of the contour in DAPCI images, which was attributed to the strength personalized by different writers. Distinction of the order of writing/stamping on documents and detection of illegal printings were accomplished with a spatial resolution of about 140 µm. A Matlab® written program was developed to facilitate the visualization of the similarity between signature images obtained by DAPCI‐MS. The experimental results show that DAPCI‐MS imaging provides rich information at the molecular level and thus can be used for the reliable document analysis in forensic applications. © 2013 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons, Ltd. 相似文献
6.
High-performance liquid chromatography (HPLC) coupled to atmospheric pressure chemical ionization (APCI) mass spectrometry was used for the separation and detection of amino acid and peptide enantiomers. With detection limits as low as 250 pg, 25 amino acids enantiomers were baseline resolved on a Chirobiotic T chiral stationary phase. APCI demonstrated an order of magnitude better sensitivity over electrospray ionization (ESI) for free amino acids and low molecular mass peptides at the high LC flow-rates necessary for rapid analysis. As the peptide chain length increased (peptides with M(r) > or = 300 Da), however, ESI proved to be the more ideal atmospheric pressure ionization source. A mobile phase consisting of 1% (w/w) ammonium trifluoroacetate in methanol and 0.1% (w/w) formic acid in water increased the sensitivity of the APCI method significantly. A step gradient was then used to separate simultaneously all 19 native protein amino acid enantiomers in less than 20 min using extracted ion chromatograms. 相似文献
7.
T. Portolés J. V. Sancho F. Hernández A. Newton P. Hancock 《Journal of mass spectrometry : JMS》2010,45(8):926-936
The potential applications of a new atmospheric pressure source for GC‐MS analysis have been investigated in this work. A list of around 100 GC‐amenable pesticides, which includes organochlorine, organophosphorus and organonitrogenated compounds, has been used to evaluate their behavior in the new source. Favoring the major formation of the molecular ion in the source has been the main goal due to the wide‐scope screening possibilities that this fact brings in comparison with the traditional, highly fragmented electron ionization spectra. Thus, the addition of water as modifier has been tested as a way to promote the generation of protonated molecules. Pesticides investigated have been classified into six groups according to their ionization/fragmentation behavior. Four of them are characterized by the abundant formation of the protonated molecule in the atmospheric pressure source, mostly being the base peak of the spectrum. These results show that wide‐scope screening could be easily performed with this source by investigating the presence of the protonated molecule ion, MH+. The developed procedure has been applied to pesticide screening in different food samples (nectarine, orange and spinach) and it has allowed the presence of several pesticides to be confirmed such as chlorpyriphos ethyl, deltamethrin and endosulfan sulfate. The availability of a quadrupole time‐of‐flight instrument made it feasible to perform additional MS/MS experiments for both standards and samples to go further in the confirmation of the identity of the detected compounds. Results shown in this paper have been obtained using a prototype source which exhibits promising features that could be applied to other analytical problems apart from those illustrated in this work. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
8.
Jun Hu Fang Wei Xu‐Yan Dong Xin Lv Mu‐Lan Jiang Guang‐Ming Li Hong Chen 《Journal of separation science》2013,36(2):288-300
The complexity of natural triacylglycerols (TAGs) in various edible oils is prodigious due to the hundreds of set is of TAG compositions, which makes the identification of TAGs quite difficult. In this investigation, the off‐line 2D system coupling of nonaqueous RP and silver‐ion HPLC with atmospheric pressure chemical ionization MS detection has been applied to the identification and quantification of TAGs in peanut oil. The method was successful in the separation of a high number of TAG solutes, and the TAG structures were evaluated by analyzing their atmospheric pressure chemical ionization mass spectra information. HPLC and MS conditions have been optimized and the fragmentation mechanisms of isomers have been validated. In addition, an internal standard approach has been developed for TAG quantification. Then this system was applied in peanut oil samples and there was a total of 48 TAGs including regioisomers that have been determined and quantified. 相似文献
9.
银离子高效液相色谱-质谱法分析血清中甘油三酯类化合物的组成 总被引:1,自引:0,他引:1
针对甘油三酯(TAG)类化合物的复杂性,建立了分析小鼠血清中TAG类化合物的方法。采用经典的氯仿-甲醇溶剂体系对血中的TAG类化合物进行提取。脂质提取物经Varian ChromSpher 5 Lipids柱分离,在0.75 mL/min的流速下以乙腈-正己烷(1:99, v/v)为流动相进行等度洗脱,采用大气压化学电离源正离子模式电离,质谱增强型全扫描、增强型子离子扫描和中性丢失扫描模式检测。根据银离子色谱对双键的保留规律以及质谱所给出的碎片离子信息,对血清中TAG类化合物进行了结构鉴定。结果表明采用该方法可以从小鼠血清中鉴定到66个TAG类化合物以及5个胆固醇酯。该方法简单,重现性好,可通用于其他样品中TAG类化合物的检测。 相似文献
10.
Hiroyuki Inoue Hiroaki Hashimoto Susumu Watanabe Yuko T. Iwata Tatsuyuki Kanamori Hajime Miyaguchi Kenji Tsujikawa Kenji Kuwayama Noriyuki Tachi Naohito Uetake 《Journal of mass spectrometry : JMS》2009,44(9):1300-1307
A novel approach to the analysis of ecstasy tablets by direct mass spectrometry coupled with thermal desorption (TD) and counter‐flow introduction atmospheric pressure chemical ionization (CFI‐APCI) is described. Analytes were thermally desorbed with a metal block heater and introduced to a CFI‐APCI source with ambient air by a diaphragm pump. Water in the air was sufficient to act as the reactive reagent responsible for the generation of ions in the positive corona discharge. TD‐CFI‐APCI required neither a nebulizing gas nor solvent flow and the accompanying laborious optimizations. Ions generated were sent in the direction opposite to the air flow by an electric field and introduced into an ion trap mass spectrometer. The major ions corresponding to the protonated molecules ([M + H]+) were observed with several fragment ions in full scan mass spectrometry (MS) mode. Collision‐induced dissociation of protonated molecules gave characteristic product‐ion mass spectra and provided identification of the analytes within 5 s. The method required neither sample pretreatment nor a chromatographic separation step. The effectiveness of the combination of TD and CFI‐APCI was demonstrated by application to the direct mass spectrometric analysis of ecstasy tablets and legal pharmaceutical products. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
11.
The major adduct of malondialdehyde with guanine, M(1)G, was measured in human urine from non-smoking healthy individuals. M1G is a mutagenic DNA lesion and a terminal product of lipid peroxidation in vivo that may be implicated in cancer related to lifestyle and diet. On the basis of a recently developed method for the quantification of M1G as an excreted deoxynucleoside using immuno-extraction purification, chemical NaBH4 reduction and liquid chromatography combined with atmospheric pressure chemical ionization tandem mass spectrometry, we demonstrate that the average 24 h excretion rate of M1G-dR is about 12 +/- 3.8 fmol kg(-1) (n = 5). 相似文献
12.
Negative-ion atmospheric pressure chemical ionization (APCI) mass spectrometry and in-source collisionally induced dissociation (CID) were employed to obtain structural information of lutein esters from marigold extract. Both molecular ions and structurally significant fragments corresponding to the loss of fatty acids were observed in high abundance in the current study. Six lutein diesters including lauroylmyristoyl-lutein (LML), dimyristoyl-lutein (dML), myristoylpalmitoyl-lutein (MPL), dipalmitoyl-lutein (dPL), palmitoylstearoyl-lutein (PSL) and distearoyl-lutein (dSL) were characterized in a marigold flower extract. Breakdown curves (plots of relative ion abundance vs. internal energy) of three lutein diesters were established by monitoring the relative ion abundance of molecular and fragment ions at different cone voltages during negative-ion APCI-LC/MS analysis. 相似文献
13.
复硝酚钠(SNP)是一种生长调节剂,在我国动物源食品检测中被列为禁用药物。由于复硝酚钠痕量分析方法不成熟,至今尚无标准检测方法,因此建立复硝酚钠中3种组分(5-硝基愈创木酚钠、对硝基酚钠和邻硝基酚钠)同时检测的方法对我国动物源食品中复硝酚钠残留水平的控制、检测标准的制定和政府相应管理措施的实行采取具有一定的理论和现实意义并兼具创新性。研究建立了高效液相色谱-大气压化学电离-串联质谱(HPLC-APCI-MS/MS)对猪肉、鸡肉、鱼肉和肝脏中复硝酚钠3种组分残留量的检测方法。样品采用氢氧化钠溶液提取,用盐酸调节pH值为酸性后,加氯化钠使溶液饱和,再用乙腈溶液反萃两次后,合并上清液并加入饱和氯化钠溶液,再经正己烷液液萃取除脂后吸出中间乙腈层,浓缩并定容后,以甲醇-水溶液作为流动相进行梯度洗脱,采用CORTECT C18色谱柱分离,大气压化学电离,在多反应监测(MRM)负离子模式下测定,外标法定量分析。5-硝基愈创木酚钠、对硝基酚钠和邻硝基酚钠分别在0.5~10、1.0~20和2.5~50 μg/L范围内线性良好,定量限分别为1.0、2.0和5.0 μg/kg,在定量限、2倍定量限和10倍定量限加标水平上的回收率分别为81.5%~98.4%、81.5%~102%和81.4%~95.1%,相对标准偏差分别为1.51%~5.98%、1.10%~8.85%和0.91%~8.61%(n=6),均符合要求,能够满足动物源食品中复硝酚钠残留量的检测要求。 相似文献
14.
di Donna L Grassi G Mazzotti F Perri E Sindona G 《Journal of mass spectrometry : JMS》2004,39(12):1437-1440
A high-throughput method is presented for the determination of rotenone in contaminated matrices. The procedure involves atmospheric pressure chemical ionization tandem mass spectrometry with a triple-quadrupole instrument and the use as internal standard of a cycloadduct derivative of rotenone itself. The method was applied to the evaluation of the decay of rotenone in olives and olive oil at various times after exposure to the contaminant. 相似文献
15.
Rhodiola rosea L. (Golden Root) has been used for a long time as an adaptogen in Chinese traditional medicine and is reported to have many pharmacological properties. A liquid chromatographic (LC) method with mass spectrometric (MS) detection based on selected ion monitoring (SIM) was developed for determining salidroside, sachaliside 1, rosin, 4-methoxycinnamyl-O-beta-glucopyranoside, rosarin, rosavin, cinnamyl-(6'-O-beta-xylopyranosyl)-O-beta-glucopyranoside, 4-methoxy-cinnamyl-(6'-O-alpha-arabinopyranosyl)-O-beta-glucopyranoside, rosiridin and benzyl-O-beta-glucopyranoside from the callus and plant extracts in one chromatographic run. Good linearity over the range 0.5-500 ng ml(-1) for salidroside, 2-2000 ng ml(-1) for rosavin and 2-500 ng ml(-1) for benzyl-O-beta-glucopyranoside was observed. The intra-assay accuracy and precision within quantitation ranges varied between -10.0 and +13.2% and between 0.7 and 9.0%, respectively. Optimization of the ionization process was performed with electrospray and atmospheric pressure chemical ionization techniques using four different additive compositions for eluents in the LC/MS scan mode, using both positive and negative ion modes. The best ionization sensitivity for the compounds studied was obtained with electrospray ionization when using pure water without any additives as the aqueous phase. 相似文献
16.
液相色谱-大气压化学电离离子阱质谱法测定烟草中的游离茄尼醇 总被引:1,自引:0,他引:1
用液相色谱/大气压化学电离离子阱质谱建立了一种分析烟草中游离茄尼醇的方法。烟草样品用甲醇振荡提取30 min,在分析前无需进行其它前处理。在1.8μm快速分离C18色谱短柱上用V(甲醇)∶V(异丙醇)=85∶15等梯度洗脱实现了茄尼醇的快速分离。用不带碰撞能量的二级质谱全扫描选择监测离子m/z 613.6进行定量,检出限为0.4μg/L,RSD为1.1%,两种添加量的回收率分别为97%和99%。方法应用于不同烟草和烟草制品样品的检测分析。 相似文献
17.
18.
Determination of polycyclic aromatic hydrocarbons in fractions in asphalt mixtures using liquid chromatography coupled to mass spectrometry with atmospheric pressure chemical ionization 下载免费PDF全文
Paulo Cicero Nascimento Luciana Assis Gobo Denise Bohrer Leandro Machado Carvalho Margareth Coutinho Cravo Leni Figueiredo Mathias Leite 《Journal of separation science》2015,38(13):2238-2244
An analytical method using liquid chromatography coupled to mass spectrometry with atmospheric pressure chemical ionization for the determination of polycyclic aromatic hydrocarbons in asphalt fractions has been developed. The 14 compounds determined, characterized by having two or more condensed aromatic rings, are expected to be present in asphalt and are considered carcinogenic and mutagenic. The parameters of the atmospheric pressure chemical ionization interface were optimized to obtain the highest possible sensitivity for all of the compounds. The limits of detection ranged from 0.5 to 346.5 μg/L and the limits of quantification ranged from 1.7 to 1550 μg/L. The method was validated against a diesel particulate extract standard reference material (NIST SRM 1975), and the obtained concentrations agreed with the certified values. The method was applied to asphalt samples after its fractionation according to ASTM D4124 and the method of Green. The concentrations of the seven polycyclic aromatic hydrocarbons quantified in the sample ranged from 0.86 mg/kg for benzo[ghi]perylene to 98.32 mg/kg for fluorene. 相似文献
19.
20.
Established and emerging atmospheric pressure surface sampling/ionization techniques for mass spectrometry 总被引:1,自引:0,他引:1
The number and type of atmospheric pressure techniques suitable for sampling analytes from surfaces, forming ions from these analytes, and subsequently transporting these ions into vacuum for interrogation by MS have rapidly expanded over the last several years. Moreover, the literature in this area is complicated by an explosion in acronyms for these techniques, many of which provide no information relating to the chemical or physical processes involved. In this tutorial article, we sort this vast array of techniques into relatively few categories on the basis of the approaches used for surface sampling and ionization. For each technique, we explain, as best known, many of the underlying principles of operation, describe representative applications, and in some cases, discuss needed research or advancements and attempt to forecast their future analytical utility. Copyright (c) 2008 John Wiley & Sons, Ltd. 相似文献