首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A simple and sensitive liquid chromatography–electrospray ionization–tandem mass spectrometry (LC‐ESI‐MS/MS) technique was developed and validated for the determination of sibutramine and its N‐desmethyl metabolites (M1 and M2) in human plasma. After extraction with methyl t‐butyl ether, chromatographic separation of analytes in human plasma was performed using a reverse‐phase Luna C18 column with a mobile phase of acetonitrile–10 mm ammonium formate buffer (50:50, v/v) and quantified by ESI‐MS/MS detection in positive ion mode. The flow rate of the mobile phase was 200 μL/min and the retention times of sibutramine, M1, M2 and internal standard (chlorpheniramine) were 1.5, 1.4, 1.3 and 0.9 min, respectively. The calibration curves were linear over the range 0.05–20 ng/mL, for sibutramine, M1 and M2. The lower limit of quantification was 0.05 ng/mL using 500 μL of human plasma. The mean accuracy and the precision in the intra‐ and inter‐day validation for sibutramine, M1 and M2 were acceptable. This LC‐MS/MS method showed improved sensitivity and a short run time for the quantification of sibutramine and its two active metabolites in plasma. The validated method was successfully applied to a pharmacokinetic study in human. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

2.
A rapid, sensitive and specific liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantification of heteroclitin D in rat plasma after using gambogic acid as internal standard (IS). Chromatographic separation was done on a Thermo Hypersil GOLD column (30 × 2.1 mm, 3 µm) using a mobile phase consisting of methanol–water–formic acid (80:20:0.1, v/v/v). The mass spectrometer worked with positive electrospray ionization in multiple reaction monitoring mode, using target ions at [M + H]+ m/z 483.3 for heteroclitin D and [M + H]+ m/z 629.3 for the IS. The standard curve was linear (R2 ≥0.995) over the concentration range 9.98–2080 ng/mL and had good back‐calculated accuracy and precision. The intra‐ and interday precision and accuracy determined on three quality control samples (29.94, 166.4 and 1872 ng/mL) were ≤12.8 and –8.9–3.6%, respectively. The extraction recovery was ≥88.2% and the lower limit of quantification was 9.98 ng/mL. The method was successfully applied to evaluate pharmacokinetics of heteroclitin D in Sprague–Dawley rats following a single intravenous bolus injection of 2.0 mg/kg heteroclitin. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
Dimethylacetamide (DMA) is a solvent used in the preparation of intravenous busulfan, an alkylating agent used in blood or marrow transplantation. DMA may contribute to hepatic toxicity, so it is important to monitor its clearance. The aim of this study was to develop an HPLC‐UV assay for measurement of DMA in human plasma. After precipitation of plasma proteins with acetonitrile followed by dilution (1:4) with water, the extract was injected onto the HPLC and detected at 195 nm. Separation was performed using a Cogent‐HPS 5 μm C18 column (250 × 4.6 mm) preceded by a Brownlee 7 μm RP18, pre‐column (1.5 cm × 3.2 mm). The mobile phase was 25 mm sodium phosphate buffer (pH 3), containing 2.5% (v /v) acetonitrile and 0.0005% (v /v) sodium‐octyl‐sulfonate. Using a flow rate of 1 mL/min, the retention times of DMA and the internal standard (IS), 2‐chloroacetamide, were 9.5 and 3.5 min, respectively. Peak area ratio (DMA:IS) was a linear function of concentration from 1 to 1000 μg/mL. There was excellent intraday precision (<5% for 5–700 μg/mL DMA), accuracy (<3% deviation from the true concentration) and recovery (74–98%). The limits of detection and quantification were 1 and 5 μg/mL, respectively. In eight children who received intravenous busulfan, DMA concentrations ranged from 110 to 438 μg/mL.  相似文献   

4.
Dexmedetomidine (Dex) is a selective central α2‐agonist with anesthetic properties and has been used in clinical practice for sedation in the intensive care unit (ICU) after operations. In this study, an analytical assay for the determination of Dex in a small amount of plasma was developed for the application to pediatric ICU trials. The quantification of Dex was constructed using the original stable isotope Dex‐d3 for electrospray ionization‐tandem mass spectrometry (ESI‐MS/MS) in the selected reaction monitoring mode. A rapid ultra‐performance liquid chromatography technique was adopted using ESI‐MS/MS with a runtime of 3 min. Efficacious concentration levels (50 pg/mL to 5 ng/mL) could be evaluated using a very small amount of plasma (10 μL) from patients. The lower limit of the quantification was 5 pg/mL in the plasma (100 µL). For sample preparation, a solid‐phase extraction was used along with the OASIS‐HLB cartridge type. Recovery values ranged from 98.8 to 100.3% for the intra‐ [relative standard deviation (RSD), 0.9–1.3%] and inter‐ (RSD, 0.9–1.5%) day assays. A stable test had recovery values that ranged from 97.8 to 99.7% with an RSD of 1.0–1.9% for the process/wet extract, bench‐top, freeze–thaw and long‐term tests. This method was used to measure the Dex levels in plasma from pediatric ICU patients. In the clinical ICU trial, the small amount of blood (approximate plasma volume, 200 μL) remaining from blood gas analysis was reused and targeted for the clinical analysis of Dex in plasma. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
A simple, rapid and sensitive method using UPLC‐MS/MS was established and validated for simultaneous determination of gelsemine and koumine in rat plasma after oral administration of Gelsemium elegans Benth extract. Plasma was performed with methanol precipitation and berberine was chosen as the internal standard. Plasma samples were separated on an Acquity UPLC® BEH C18 column (3.0 × 50 mm, 1.7 μm) with gradient elution using acetonitrile and 0.1% formic acid aqueous solution as the mobile phase at a flow rate of 0.4 mL/min. Multiple reaction monitoring mode in positive ion mode was utilized for detection. The calibration curves were linear over the range of 0.2–100 ng/mL for gelsemine and 0.1–50 ng/mL for koumine, with the lower limits of quantification 0.2 and 0.1 ng/mL, respectively. The intra‐ and inter‐precision and accuracy were well within the acceptable ranges. The developed method was successfully applied to an in vivo pharmacokinetic study in rat after oral administration of 10 mg/kg Gelsemium elegans Benth extract.  相似文献   

6.
A highly sensitive and rapid ultraperformance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed and validated for simultaneous quantification of the four main bioactive compounds, i.e. baicalin, baicalein, wogonoside and wogonin, in rat plasma after oral administration of Radix Scutellariae extract. Clarithromycin was used as an internal standard (IS). Plasma samples were processed by protein precipitation with methanol. The separation was performed on an Acquity BEH C18 column (100 × 2.1 mm, 1.7 μm) at a flow rate of 0.4 mL/min, using 0.1% formic acid–acetonitrile as mobile phase. The MS/MS ion transit ions monitored were 447.5 → 270.1 for baicalin, 270.1 → 168.1 for baicalein, 461.2 → 284.0 for wogonoside, 284.2 → 168.1 for wogonin and 748.5 → 158.1 for IS. Method validation was performed according to US Food and Drug Administration guidelines and the results met the acceptance criteria. The lower limit of quantification (LLOQ) achieved was 1.13 ng/mL for baicalin, 1.23 ng/mL for baicalein, 0.82 ng/mL for wogonoside and 0.36 ng/mL for wogonin. The calibration curves obtained were linear (r > 0.99) over the concentration range ~ 1–1000 ng/mL. The intra‐ and inter‐day precision was <15% and the accuracy was within ±14.7%. After validation, this method was successfully applied to a pharmacokinetic study of Radix Scutellariae extract.  相似文献   

7.
In this study, a sensitive HPLC‐UV assay was developed and validated for the determination of LASSBio‐1736 in rat plasma with sodium diclofenac as internal standard (IS). Liquid–liquid extraction using acetonitrile was employed to extract LASSBio‐1736 and IS from 100 μL of plasma previously basified with NaOH 0.1 M. Chromatographic separation was carried on Waters Spherisorb®S5 ODS2 C18 column (150 × 4.6 mm, 5 μm) using an isocratic mobile phase composed by water with triethylamine 0.3% (pH 4), methanol and acetonitrile grade (45:15:40, v/v/v) at a flow rate of 1 mL/min. Both LASSBio‐1736 and IS were eluted at 4.2 and 5 min, respectively, with a total run time of 8 min only. The lower limit of quantification was 0.2 μg/mL and linearity between 0.2 and 4 μg/mL was obtained, with an R2 > 0.99. The accuracy of the method was >90.5%. The relative standard deviations intra and interday were <6.19 and <7.83%, respectively. The method showed the sensitivity, linearity, precision, accuracy and selectivity required to quantify LASSBio‐1736 in preclinical pharmacokinetic studies according to the criteria established by the US Food and Drug Administration and European Medicines Agency. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
Abivertinib represents a highly selective irreversible epidermal growth factor receptor tyrosine kinase inhibitor. Two major metabolites of abivertinib, M7 and MII-6, were detected in human plasma, which are recommended to be monitored for safety reasons in clinical trial. A high-throughput quantification method utilizing liquid chromatography–tandem mass spectrometry was designed and verified to quantify abivertinib's primary metabolites in human plasma. Solid-phase extraction was used to process the plasma, and then the analytes underwent a gradient elution separation in an Aquity UPLC BEH C18 column (1.7 μm, 2.1 × 50 mm) with mobile phase A (10 mm ammonium acetate containing 0.1% formic acid) and mobile phase B (methanol–acetonitrile, 2:8, v/v, with 0.1% formic acid). Ion transitions of M7 (m/z 490.2 → 405.1) and MII-6 (m/z 476.2 → 391.1) were monitored under multiple reaction monitoring mode and electrospray ionization in positive ion mode. This simultaneous determination method was found to have acceptable precision, accuracy and linearity in the 0.5–500 ng/mL range for M7 and the 0.5–500 ng/mL range for MII-6, accompanied by a mild matrix effect but high recovery. Further stability assessments indicated that both analytes remained stable throughout the entire experimental process from harvesting whole blood to plasma extraction and analysis.  相似文献   

9.
An LC–MS/MS method was developed and validated for the simultaneous quantification of edaravone and taurine in beagle plasma. The plasma sample was deproteinized using acetonitrile containing formic acid. Chromatographic separations were achieved on an Agilent Zorbax SB‐Aq (100 × 2.1 mm, 3.5 μm) column, with a gradient of water (containing 0.03% formic acid) and methanol as the mobile phase at a flow rate of 0.3 mL/min. The analyte detection was carried out in multiple reaction monitoring mode and the optimized precursor‐to‐product transitions of m/z [M+H]+ 175.1 → 133.0 (edaravone), m/z [M+H]+ 189.1 → 147.0 (3‐methyl‐1‐p‐tolyl‐5‐pyrazolone, internal standard, IS), m/z [M–H]? 124.1→80.0 (taurine), and m/z [M–H]? 172.0 → 80.0 (sulfanilic acid, IS) were employed to quantify edaravone, taurine, and their corresponding ISs, respectively. The LOD and the lower LOQ were 0.01 and 0.05 μg/mL for edaravone and 0.66 and 2 μg/mL for taurine, respectively. The calibration curves of these two analytes demonstrated good linearity (r > 0.99). All the validation data including the specificity, precision, recovery, and stability conformed to the acceptable requirements. This validated method has successfully been applied in the pharmacokinetic study of edaravone and taurine mixture in beagle dogs.  相似文献   

10.
A sensitive, simple method for quantification of chloroquine (CQ) and desethylchloroquine (MCQ) in whole blood and plasma from Plasmodium vivax patients has been developed using HPLC with diode array detection (DAD). Solid‐phase extraction on Isolute‐96‐CBA was employed to process 100 μL of plasma/whole blood samples. CQ, MCQ and quinine were separated using a mobile phase of phosphate buffer 25 mm , pH 2.60–acetonitrile (88:12, v/v) with 2 mm sodium perchlorate on a Zorbax SB‐CN 150 × 4.6 mm, 5 μm column at a flow rate of 1.2 mL/min, at ambient temperature in 10 min, with the DAD wavelength of 343 nm. The method was linear over the range of 10–5000 ng/mL for both CQ and MCQ in plasma and whole blood. The limit of detection was 4 ng/mL and limit of quantification was 10 ng/mL in both plasma and blood for CQ and MCQ. The intra‐, inter‐ and total assay precision were <10% for CQ and MCQ in plasma and whole blood. In plasma, the accuracies varied between 101 and 103%, whereas in whole blood, the accuracies ranged from 97.0 to 102% for CQ and MCQ. The method is an ideal technique with simple facilities and instruments, bringing about good separation in comparison with previous methods. © 2016 The Authors Biomedical Chromatography Published by John Wiley & Sons Ltd  相似文献   

11.
We developed and validated an accurate and sensitive LC–MS/MS method for the simultaneous quantitation of ginsenoside Rg3 and Rh2 epimers (R‐Rg3, S‐Rg3, R‐Rh2, and S‐Rh2) in rat plasma. Analytes were extracted from 0.1 mL aliquots of rat plasma by liquid–liquid extraction, using 2 mL of ethyl acetate. In this assay, dioscin (500 ng/mL) was used as an internal standard. Chromatographic separation was conducted using an Acclaim RSLC C18 column (150 × 2.1 mm, 2.2 μm) at 40°C, with a gradient mobile phase consisting of 0.1% formic acid in distilled water and in acetonitrile, a flow rate of 0.35 mL/min, and a total run time of 20 min. Detection and quantification were performed using a mass spectrometer in selected reaction‐monitoring mode with negative electrospray ionization at m/z 783.4 → 161.1 for R‐Rg3 and S‐Rg3, m/z 621.3 → 161.1 for R‐Rh2 and S‐Rh2, and m/z 867.2 → 761.5 for the internal standard. For R‐Rg3 and S‐Rg3, the lower limit of quantification was 5 ng/mL, with a linear range up to 500 ng/mL; for R‐Rh2 and S‐Rh2, the lower limit of quantification was 150 ng/mL, with a linear range up to 6000 ng/mL. The coefficient of variation for assay precision was less than 10.5%, with an accuracy of 86.4–112%. No relevant cross‐talk or matrix effect was observed. The method was successfully applied to a pharmacokinetic study after oral administration of 400 mg/kg and 2000 mg/kg of BST204, a fermented ginseng extract, to rats. We found that the S epimers exhibited significantly higher plasma concentrations and area under curve values for both Rg3 and Rh2. This is the first report on the separation and simultaneous quantification of R‐Rg3, S‐Rg3, R‐Rh2, and S‐Rh2 in rat plasma by LC‐MS/MS. The method should be useful in the clinical use of ginseng or its derivatives.  相似文献   

12.
Nitazoxanide (NTZ) is a broad‐spectrum antimicrobial agent. Tizoxanide (T) and tizoxanide glucuronide (TG) are the major circulating metabolites after oral administration of NTZ. A rapid and specific LC–MS/MS method for the simultaneous quantification of T and TG in mouse plasma was developed and validated. A simple acetonitrile‐induced protein precipitation method was employed to extract two analytes and the internal standard glipizide from 50 μL of mouse plasma. The purified samples were resolved using a C18 column with a mobile phase consisting of acetonitrile and 5 mm ammonium formate buffer (containing 0.05% formic acid) following a gradient elution. An API 3000 triple quadrupole mass spectrometer was operated under multiple reaction‐monitoring mode with electrospray ionization. The precursor‐to‐product ion transitions m/z 264 → m/z 217 for T and m/z 440 → m/z 264 for TG were used for quantification. The developed method was linear in the concentration ranges of 1.0–500.0 ng/mL for T and 5.0–1000.0 ng/mL for TG. The intra‐ and inter‐day precision and accuracy of the quality control samples at low, medium and high concentrations exhibited an RSD of <13.2% and the accuracy values ranged from ?9.6 to 9.3%. We used this validated method to study the pharmacokinetics of T and TG in mice following oral administration of NTZ. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
A sensitive and reliable bioanalytical method was established for quantitati\ve and pharmacokinetic investigation of nine ginsenosides and seven bufadienolides in rat plasma after the oral administration of Shexiang Baoxin Pill by liquid chromatography–electrospray ionization tandem mass spectrometry, using tinidazole and digoxin as internal standards (ISTDs). All of the analytes and ISTDs obtained satisfactory recoveries by solid‐phase extraction using an Oasis HLB μElution Plate, which was eluted with methanol and ethyl acetate successively, and chromatographic separation was achieved on a Shim‐pack XR‐ODSIIcolumn (75 × 2.0 mm, 2.2 μm) with gradient elution using a mixture of acetonitrile–0.1% formic acid solution (v /v) as the mobile phase at a flow rate of 0.3 mL/min. Detection was carried out by a triple‐quadrupole tandem mass spectrometry with positive/negative ion switching multiple reaction monitoring mode. All analytes showed good linearity over a wide concentration range (r 2 > 0.99). The lower limit of quantification was in the range 0.625–12.5 ng/mL for bufadienolides and 2–5.5 ng/mL for ginsenosides, and the mean recoveries of all analytes were in the range 78.29–99.35%. The intra‐ and inter‐day precisions (RSD) were in the range 0.08–12.38% with the accuracies between 86.09 and 99.40%. The validated method was then successfully applied to pharmacokinetic study of the above 16 compounds in rat plasma. Pharmacokinetic results indicated that the developed extraction and analytical method could be employed as a rapid, effective technique for pharmacokinetic study of multiple components, especially various polarity that are difficult to extract simultaneously.  相似文献   

14.
For the first time, an HPLC method was developed and validated for the determination of stemoninine in plasma after oral and intravenous administration of the extract of the roots of Stemona tuberosa to rats. Plasma samples were analyzed on a Waters reversed‐phase C18 column using a gradient mobile‐phase of eluent A (water containing 0.1% formic acid and 0.2% triethylamine, pH 3.68) and eluent B (acetonitrile–water, 50:50, v/v). The flow rate was 1.0 mL/min and the detector wavelength was 210 nm. The Waters Oasis solid‐phase extraction cartridge was applied for the preparation of plasma samples with high recovery. A good linear relationship was obtained in the concentration range of 1.55–124 µg/mL (r = 0.9995). The limits of quantification and detection were 1.55 and 0.42 µg/mL, respectively. The average recoveries ranged from 91.11 to 96.43% in plasma at stemoninine concentrations of 3.10, 62.0 and 99.2 µg/mL. Intra‐ and inter‐batch coefficient of variations were 3.27–5.37% and 2.49–3.92%, respectively. This method was successfully applied to pharmacokinetic studies after oral and intravenous administration of Stemona tuberosa extract in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
A selective and sensitive liquid chromatography tandem mass spectrometry method was developed for the simultaneous determination of salviaflaside and rosmarinic acid in rat plasma. Sample preparation was carried out through liquid–liquid extraction with ethyl acetate using curculigoside as internal standard (IS). The analytes were determined by selected reaction monitoring operated in the positive ESI mode. Chromatographic separation was performed on an Agilent Eclipse Plus C18 column (100 × 4.6 mm, 1.8 μm) with a mobile phase consisting of methanol–water–formic acid (50:50:0.1, v/v/v) at a flow rate of 0.3 mL/min. The run time was 1.9 min per sample and the injection volume was 5 μL. The method had an LLOQ of 1.6 ng/mL for salviaflaside and 0.94 ng/mL for rosmarinic acid in plasma. The linear calibration curves were fitted over the range of 1.6–320 ng/mL for salviaflaside and 0.94–188 ng/mL for rosmarinic acid in plasma with correlation coefficients (r2) >0.99. Intra‐ and inter‐day precisions (relative standard deviation) were < 13.5%, and accuracies (relative error) were between −8.6% and 14.5% for all quality control samples. The method was validated and applied to the pharmacokinetics of salviaflaside and rosmarinic acid in plasma after oral administration of Prunella vulgaris extract to rats.  相似文献   

16.
A rapid and sensitive liquid chromatography with tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the simultaneous determination of luteolin, luteolin‐7‐O β ‐D‐glucopyranoside, physalin A, physalin D and physalin L in rat plasma. Scutellarein and dexamethasone were used as the internal standards (IS). Plasma samples were prepared by liquid‐liquid extraction with ethyl acetate. The five constituents were separated on an Acquity UPLC BEH C18 column (100 mm × 2.1 mm, 1.7 μm). A gradient elution procedure was used with acetonitrile (A)‐0.1% aqueous formic acid (B). Mass spectrometric detection was performed in negative ion multiple reaction monitoring mode with an electrospray ionization (ESI) source. This method showed good linearity (r 2 > 0.997) over a concentration range of 2.0–500 ng/mL with a lower limit of quantification of 2.0 ng/mL for all five compounds. The inter‐ and intra‐day accuracy ranged from 91.7 to 104%, and precisions (RSD) were <6.46% for all analytes. The extraction recoveries of all analytes were >85%. This validated method was successfully applied for the first time to the pharmacokinetic study of five ingredients after oral administration of 70% ethanol extract of Chinese lantern in rats.  相似文献   

17.
《Analytical letters》2012,45(7):1365-1379
Abstract

A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC–ESI–MS) method was developed and validated for the identification and quantification of indapamide in human plasma. After the addition of the internal standard (IS) and 0.1 M sodium hydroxide solution, plasma samples were extracted with diethyl ether. The organic layer was evaporated under a stream of nitrogen at 40°C. The residue was reconstituted with 200 µL methanol. The compounds were separated on a stainless‐steel column (C18 Shim‐pack 5 µm 150 mm×2.0 mm I.D., Shimadzu) at a flow rate of 0.2 mL/min by a gradient elution. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via an electrospray ionization (ESI) source. The method was proved to be sensitive and specific by testing six different plasma batches. Linearity was established for the range of concentrations 0.5–100.0 ng/mL with a coefficient of determination (r) of 0.9998 and good back‐calculated accuracy and precision. The intra‐ and inter‐day precision (RSD%) was lower than 10% and accuracy ranged from 85% to 115%. The lower limit of quantification was identifiable and reproducible at 0.2 ng/mL with 0.2 mL plasma. The proposed method enables the unambiguous identification and quantification of indapamide for pharmacokinetic, bioavailability, or bioequivalence studies.  相似文献   

18.
A sensitive and selective RP‐HPLC method has been developed and validated for the quantification of a highly potent poly ADP ribose polymerase inhibitor talazoparib (TZP) in rat plasma. Chromatographic separation was performed with isocratic elution method. Absorbance for TZP was measured with a UV detector (SPD‐20A UV–vis) at a λmax of 227 nm. Protein precipitation was used to extract the drug from plasma samples using methanol–acetonitrile (65:35) as the precipitating solvent. The method proved to be sensitive and reproducible over a 100–2000 ng/mL linearity range with a lower limit of quantification (LLQC) of 100 ng/mL. TZP recovery was found to be >85%. Following analytical method development and validation, it was successfully employed to determine the plasma protein binding of TZP. TZP has a high level of protein binding in rat plasma (95.76 ± 0.38%) as determined by dialysis method.  相似文献   

19.
A sensitive and efficient liquid chromatography tandem mass spectrometry method was developed and validated for the simultaneous determination of piperaquine (PQ) and its N ‐oxidated metabolite (PQ‐M) in plasma. A simple protein precipitation procedure was used for sample preparation. Adequate chromatographic retention was achieved on a C18 column under gradient elution with acetonitrile and 2 mm aqueous ammonium acetate containing 0.15% formic acid and 0.05% trifluoroacetic acid. A triple‐quadrupole mass spectrometer equipped with an electrospray source was set up in the positive ion mode and multiple reaction monitoring mode. The method was linear in the range of 2.0–400.0 ng/mL for PQ and 1.0–50.0 ng/mL for PQ‐M with suitable accuracy, precision and extraction recovery. The lower limits of detection (LLOD) were established at 0.4 and 0.2 ng/mL for PQ and PQ‐M, respectively, using 40 μL of plasma sample. The matrix effect was negligible under the current conditions. No effect was found for co‐administrated artemisinin drugs or hemolysis on the quantification of PQ and PQ‐M. Stability testing showed that two analytes remained stable under all relevant analytical conditions. The validated method was successfully applied to a pharmacokinetic study performed in rats after a single oral administration of PQ (60 mg/kg).  相似文献   

20.
We describe a simple, rapid, selective and sensitive HPLC method coupled with fluorescence detection for simultaneous determination of 10 kinds of biogenic amines (BAs: tryptamine, 2‐phenethylamine, putrescine, cadaverine, histamine, 5‐hydroxytryptamine, tyramine, spermidine, dopamine and spermine). BAs and IS were derivated with dansyl chloride. Fluorescence detection (λex/λem = 340/510 nm) was used. A satisfactory result for method validation was obtained. The assay was shown to be linear over the ranges 0.005–1.0 μg/mL for tryptamine, 2‐phenethylamine and spermidine, 0.025–1.0 μg/mL for putrescine, 0.001–1.0 μg/mL for cadaverine, 0.25–20 μg/mL for histamine, 0.25–10 μg/mL for 5–hydroxytryptamine and dopamine, and 0.01–1.0 μg/mL for tyramine and spermine. The limits of detection and the limits of quantification were 0.3–75.0 ng/mL and 1.0–250.0 ng/mL, respectively. Relative standard deviations were ≤5.14% for intra‐day and ≤6.58% for inter‐day precision. The recoveries of BAs ranged from 79.11 to 114.26% after spiking standard solutions of BAs into a sample at three levels. Seven kinds of BAs were found in rat plasma, and the mean values of tryptamine, 2‐phenethylamine, putrescine, cadaverine, histamine, spermidine and spermine determined were 52.72 ± 7.34, 11.45 ± 1.56, 162.56 ± 6.26, 312.75 ± 18.11, 1306.50 ± 116.16, 273.89 ± 26.41 and 41.51 ± 2.07 ng/mL, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号