首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Indole alkaloids are the main bioactive/toxic components in Gelsemium elegans Benth. To determine the distribution and contents of indole alkaloids in its different medicinal parts, a novel and rapid method using ultra‐high performance LC (UPLC) with MS/MS has been established and validated with an optimized ultrasound/microwave‐assisted extraction method. Four constituents, namely, humantenidine, humantenmine, gelsemine, and koumine, were simultaneously determined in 6 min. Chromatographic separation was achieved on an ultra‐high performance LC BEH C18 column with a gradient mobile phase consisting of methanol and water (containing 0.1% formic acid both in methanol and water) at a flow rate of 0.3 mL/min. The detection was performed on a triple quadrupole electrospray MS/MS by positive ion multiple‐reaction monitoring mode. All the analytes showed good linearity (r ≥ 0.9934) within a concentration range from 0.1–25 μg/mL with a LOQ of 25–50 ng/mL. The overall intra‐ and intervariations of four components were <4.7% with an accuracy of 97.3–101.3%. The analysis results showed that there were remarkable differences in the distribution and contents of four chemical markers in the roots, stems, and leaves of G. elegans Benth. The findings can provide necessary and meaningful information for the rational utilization of its resources.  相似文献   

2.
A fast, sensitive, and efficient ultra‐fast LC–ESI‐MS/MS method was developed for the simultaneous quantitation of six highly toxic Aconitum alkaloids, that is, aconitine, mesaconitine, hypaconitine, benzoylaconine, benzoylmesaconine, and benzoylhypaconine, in rat plasma after oral administration of crude ethanol extracts from Aconiti kusnezoffii radix by ultrasonic extraction, reflux extraction for 1 h, and reflux extraction for 3 h, respectively. The separation of six Aconitum alkaloids and aminopyrine (internal standard) was performed on an InertSustain® C18 column, and the quantification of the analytes was performed on a 4000Q ultra‐fast LC–MS/MS system with turbo ion spray source in the positive ion and multiple‐reaction monitoring mode. Absolute recoveries ranged within 65.06–85.1% for plasma samples. The intra‐ and interday precision and accuracy of analytes were satisfactory. The methods were validated with sensitivity reaching the lower LOQ for aconitine, mesaconitine, hypaconitine, benzoylaconine, benzoylmesaconine, and benzoylhypaconine, which were 0.025, 0.025, 0.050, 0.025, 0.025, and 0.100 ng/mL, respectively. The method was successfully applied to a pharmacokinetic study of six Aconitum alkaloids in rat plasma after oral administration of crude ethanol extracts from the raw root of Aconitum kusnezoffii Reichb. by three different extraction processes.  相似文献   

3.
A confirmatory method for detecting five ergot alkaloids, ergocristine, ergotamine, ergonovine, ergocornine and alpha-ergokryptine, in rye flour is described using high performance liquid chromatography coupled to tandem mass spectrometry detection by monitoring two transition reactions per analyte. The procedure entails a liquid-liquid extraction followed by a clean-up step using a C18 solid-phase extraction (SPE) cartridge. An analogue compound, methysergide hydrogen maleinate, was used to assess both repeatability sample preparation and potential MS response fluctuations. The method was fully validated according to the European Union (EU) criteria. Detection and quantification limits of all analytes were calculated ranging from 7 to 11 microg/kg and from 23 to 37 microg/kg, respectively. Fifteen rye flour samples were investigated with the newly developed method, and none of them were above the current Swiss limits of 200mg/kg for total ergot alkaloids.  相似文献   

4.
A sensitive and selective confirmatory method for milk‐residue analysis of ten quinolones and eight cephalosporins by LC‐MS/MS has been developed herein. For the chromatographic separation of target analytes, a Perfectsil ODS‐2 (250 × 4 mm, 5 μm) analytical column was used and gradient elution was applied, using a mobile phase of 0.1% w/w TFA in water and 0.1% w/w TFA in ACN. Ultrasound‐assisted matrix solid‐phase dispersion procedure was applied for the extraction and clean‐up procedure of antimicrobials agents from milk matrix using a mixture of Bond Elut Plexa sorbent and QuEChERS. The method was validated meeting the European Legislation determining selectivity, linearity response, trueness, precision (repeatability and between‐day reproducibility), decision limit, detection capability, and ruggedness following the Youden approach. Recoveries of all antibiotics ranged from 81.7 to 117.9%, while RSD values were lower than 13.7%. Limits of quantification for all examined compounds ranged from 2.4 to 15.0 μg/kg, substantially lower than the maximum residue limits established by the European Union (30–100 μg/kg).  相似文献   

5.
Saflufenacil is a new protoporphyrinogen‐IX‐oxidase inhibitor herbicide. When used, it can enter the soil and has a high risk to reach and contaminate groundwater and aquatic systems. A rapid and sensitive method of ultra‐performance LC with MS/MS was developed for the simultaneous determination of saflufenacil and its two metabolites in soil samples. A modified quick, easy, cheap, effective, rugged, and safe method was applied as the pretreatment procedure. The method was validated by five types of soil samples collected from several regions of China, which all showed good linearity (R2 ≥ 0.9914) and precision (RSD ≤ 26.2%). The average recoveries of the three analytes ranged between 74.1 and 118.9% at spiking levels of 3–300 μg/kg. The method limits of detection (S/N 3:1) and method limits of quantification (S/N 10:1) achieved are in the ranges of 0.25–2.75 and 0.83–9.16 μg/kg, respectively. This indicated that the developed ultra‐performance LC with MS/MS method is a promising analytical tool for monitoring the environmental risks posed by saflufenacil.  相似文献   

6.
Amantadine‐functionalized magnetic microspheres (Fe3O4@SiO2@ADME) were prepared and applied as magnetic solid‐phase extraction (MSPE) adsorbents for the enrichment and analysis of five opium alkaloids in hotpot seasoning samples with liquid chromatography coupled to quadrupole linear ion trap mass spectrometry (LC‐QqQLIT‐MS/MS). The adsorbents could strongly adsorb the opium alkaloids via hydrogen‐bonding, hydrophobic, and π–π conjugation effects. The established MSPE, combined with stable isotope‐labeled internal standards could reduce the matrix effect significantly. In the LC‐QqQLIT‐MS/MS analysis, the precursor and product ions of the analytes were monitored quantitatively and qualitatively by the multiple reaction monitoring and enhanced product ion mode, improving the reliability of detection for real samples. Under the optimum conditions, the limits of detection and limits of quantification were found to be in the range of 0.05–0.8 μg/kg and 0.25–2.5 μg/kg, respectively, and the recoveries of all targets were in the range 80.1–115.3%, with the intra‐day and inter‐day relative standard deviations being less than 9.4 and 10.7%, respectively. Finally, the proposed method was successfully applied to the determination of illegal additives of opium alkaloids in hotpot seasoning samples.  相似文献   

7.
A novel, sensitive, and reliable LC‐MS/MS method for multiresidue analysis of nine β‐agonists (salbutamol, terbutaline, cimaterol, fenoterol, clorprenaline, ractopamine, tulobuterol, clenbuterol, and penbuterol) in four farm animal muscles was developed. Muscle matrix was extracted with acetonitrile–10% sodium carbonate solution, and then was subjected to cleanup using a SPE cartridge packed with new polymer synthesized in acetone. Chromatographic separation of the components was performed on a Luna C18 column using 0.1% of formic acid in water and acetonitrile. The mass spectrometer was operated in the positive electrospray mode. Good precision and accuracy were obtained for all analytes (except for fenoterol) at the spiked three levels of 1.0, 10, and 50 μg/kg. The decision limit and detection capability of nine β‐agonists ranged from 0.04 to 0.18 and 0.15 to 0.69 μg/kg, respectively. The method developed was successfully applied to the monitoring of nine β‐agonists in pork, beef, mutton, and chicken from Chinese markets.  相似文献   

8.
建立了蔬菜和水果中腈吡螨酯残留量的超高效液相色谱-串联质谱(UPLC-MS/MS)分析方法。样品经乙腈均质提取,混合使用乙二胺-N-丙基硅烷(PSA)和C18两种基质分散净化剂净化,净化液过膜后直接进行UPLC-MS/MS检测。通过考察腈吡螨酯在不同果蔬样品中的基质效应发现,采用UPLC-MS/MS检测蔬菜和水果中腈吡螨酯残留量时,腈吡螨酯在不同种类样品中存在不同程度的基质减弱效应,采用空白基质溶液稀释标准建立校正的标准曲线外标法定量以消除基质效应。结果表明,腈吡螨酯在0.05~10μg/L浓度范围内具有良好的线性关系,相关系数不低于0.999 6。在0.000 05~2 mg/kg范围内进行加标回收率实验,平均回收率为81.1%~99.3%,相对标准偏差为4.7%~9.3%,方法的定量下限为0.043μg/kg,检出限为0.013μg/kg。  相似文献   

9.
The prerequisites for forensic confirmatory analysis by LC/MS/MS with respect to European Union guidelines are chromatographic separation, a minimum number of two MS/MS transitions to obtain the required identification points and predefined thresholds for the variability of the relative intensities of the MS/MS transitions (MRM transitions) in samples and reference standards. In the present study, a fast, sensitive and robust method to quantify tramadol, chlorpheniramine, dextromethorphan and their major metabolites, O‐desmethyltramadol, dsmethyl‐chlorpheniramine and dextrophan, respectively, in human plasma using ibuprofen as internal standard (IS) is described. The analytes and the IS were extracted from plasma by a liquid–liquid extraction method using ethyl acetate–diethyl‐ether (1:1). Extracted samples were analyzed by ultra‐high‐performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC‐ESI‐MS/MS). Chromatographic separation was performed by pumping the mobile phase containing acetonitrile, water and formic acid (89.2:11.7:0.1) for 2.0 min at a flow rate of 0.25 μL/min into a Hypersil‐Gold C18 column, 20 × 2.0 mm (1.9 µm) from Thermoscientific, New York, USA. The calibration curve was linear for the six analytes. The intraday precision (RSD) and accuracy (RE) of the method were 3–9.8 and ?1.7–4.5%, respectively. The analytical procedure herein described was used to assess the pharmacokinetics of the analytes in 24 healthy volunteers after a single oral dose containing 50 mg of tramadol hydrochloride, 3 mg chlorpheniramine maleate and 15 mg of dextromethorphan hydrobromide. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
Aptamers are single‐stranded oligonucleotides with high affinity and specificity and are widely used in targets separation and enrichment. Here, an aptamer‐affinity column (AAC) was firstly prepared in‐house through a covalent immobilization strategy. Then, ochratoxin A (OTA) in ginger powder was absorbed and enriched using the new aptamer‐based clean‐up technology for the first time, and was further analyzed by ultra high performance liquid chromatography with fluorescence detection. After optimization, the average recoveries for blank samples spiked with OTA at 5, 15, and 45 μg/kg ranged from 85.36 to 96.83%. Furthermore, the AAC exhibited a similar accuracy as an immunoaffinity column to clean up OTA in ginger powder. Above all, it exhibited better reusability, twice that of the immunoaffinity column, had lower toxicity and cost, and took less time. Of 25 contaminated ginger powder samples, OTA contamination levels ranged from 1.51 to 4.31 μg/kg, which were lower than the European Union (EU) regulatory limits. All the positive samples were further confirmed by ultra‐fast LC with MS/MS. In conclusion, the method of clean‐up based on the AAC coupled to ultra‐HPLC with fluorescence detection was rapid, specific, and sensitive for the quantitative analysis of OTA in a complex matrix.  相似文献   

11.
Pesticides, which are used as plant protection products, can enter the food chain, and exposure to these xenobiotics can cause a wide array of health problems in humans. Therefore, the objective of the present study was to develop an analytical method for the simultaneous determination of residual spinosad (sum of spinosyn A and D), temephos and piperonyl butoxide in porcine muscle, egg, milk, eel, flatfish and shrimp (sampling period: February to June 2018) using liquid chromatography–triple quadrupole tandem mass spectrometry (LC–MS/MS). The target analytes were extracted with a combination of acidified acetonitrile and ethyl acetate and subsequently purified with original QuEChERS kits (composed of magnesium sulfate and sodium chloride) as well as n‐hexane. All analytes were separated on a reversed‐phase analytical column using a mobile phase of (A) 0.1% formic acid containing 10 mm ammonium formate in distilled water and (B) methanol. Good linearity (R2 ≥ 0.980) was achieved over the tested concentration range (3.5–35 μg/kg for spinosyn A; 1.5–15 μg/kg for spinosyn D; 5–50 μg/kg for temephos and piperonyl butoxide) in matrix‐matched standard calibrations. Fortified samples at three spiking levels yielded recoveries in the range of 71–105% with relative standard deviations ≤9.2%. The applicability of the method was evaluated via evaluating samples collected from a large wholesale market located in Seoul, and none of the samples contained any of the target analytes. In conclusion, the current approach is simple, efficient and reliable and can successfully determine the residual levels of spinosad, temephos and piperonyl butoxide in complex animal‐derived food products.  相似文献   

12.
The objective of this study was to develop a sensitive and reliable ultra performance liquid chromatography‐tandem mass spectrometry (UPLC‐MS/MS) method for simultaneous quantitation of three monoterpene glycosides (paeoniflorin, alibiflorin and oxypaeoniflorin) and four alkaloids (tetrahydropalmatine, corydaline, dehydrocorydaline and berberine), the main active ingredients of Radix Paeoniae Rubra extract (RPE) and Corydalis yanhusuo extract (CYE) in Huo Luo Xiao Ling Dan (HLXLD), and to compare the pharmacokinetics of these active ingredients in normal and arthritic rats orally administrated with HLXLD or RPE/CYE alone. The analytes and internal standard (IS) (geniposide) were separated on a XBridge C18 column (150 × 4.6 mm, 3.5 µm) using gradient elution with the mobile phase consisting of methanol and 0.01% formic acid in water at a flow rate of 0.6 ml/min. The detection of the analytes was performed on Acquity UPLC‐MS/MS system with an electrospray ionization and multiple reaction monitoring mode via polarity switching between negative (for monoterpene glycosides) and positive (for alkaloids) ionization mode. The lower limits of quantification were 2.5, 1, 0.5, 0.2, 0.2, 0.02 and 0.01 ng/ml for paeoniflorin, alibiflorin, oxypaeoniflorin, tetrahydropalmatine, corydaline, dehydrocorydaline and berberine, respectively. Intra‐day and inter‐day precision and accuracy of analytes were well within acceptance criteria (15%). The mean extraction recoveries of analytes and IS from rat plasma were all more than 83.1%. The validated method has been successfully applied to determination of the analytes. Results showed that there were remarkable differences in pharmacokinetic properties of the analytes between herbal formula and single herb group, normal and arthritic group. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
The efficiency of two extraction techniques—ultrasound‐assisted extraction and pressurized liquid extraction—are compared and evaluated in the determination of parabens in compost samples. The extraction parameters for each technique were accurately optimized. The selected compounds were detected and quantified using ultra‐performance LC MS/MS, operating in negative ESI and in SRM mode. The analytes were separated in less than 5 min. Ethylparaben (ring‐13C6 labeled) was used as an internal standard. Two selective, sensitive, and accurate analytical methods were developed and validated. The LODs of the methods ranged from 3 to 7 ng/g and the LOQs from 10 to 23 ng/g, while inter‐ and intraday variability was under 6% in all cases. The methods were validated separately by using matrix‐matched calibration and recovery assays with spiked samples. Recovery rates ranged from 94.0 to 105.0%. Compost samples were taken from different composting plants. Although the statistical comparison demonstrated no statistically significant differences between the two extraction techniques, the method based on pressurized liquid extraction was more sensitive than the ultrasound extraction based method.  相似文献   

14.
This paper describes the first validated method for the determination of 39 mycotoxins in wheat and maize using a single extraction step followed by liquid chromatography with electrospray ionization triple quadrupole mass spectrometry (LC/ESI-MS/MS) without the need for any clean-up. The 39 analytes included A- and B-trichothecenes (including deoxynivalenol-3-glucoside), zearalenone and related derivatives, fumonisins, enniatins, ergot alkaloids, ochratoxins, aflatoxins and moniliformin. The large number and the chemical diversity of the analytes required the application of the positive as well as the negative ion ESI mode in two consecutive chromatographic runs of 21 min each. The solvent mixture acetonitrile/water/acetic acid 79 + 20 + 1 (v/v/v) has been determined as the best compromise for the extraction of the analytes from wheat and maize. Raw extracts were diluted 1 + 1 and were injected without any clean-up. Ion-suppression effects due to co-eluting matrix components were negligible in the case of wheat, whereas significant signal suppression for 12 analytes was observed in maize, causing purely proportional systematic errors. Method performance characteristics were determined after spiking blank samples on multiple levels in triplicate. Coefficients of variation of the overall process of <5.1% and <3.0% were obtained for wheat and maize, respectively, from linear calibration data. Limits of detection ranged from 0.03 to 220 microg/kg. Apparent recoveries (including both the recoveries of the extraction step and matrix effects) were within the range of 100 +/- 10% for approximately half of the analytes. In extreme cases the apparent recoveries dropped to about 20%, but this could be compensated for to a large extent by the application of matrix-matched standards to correct for matrix-induced signal suppression, as only a few analytes such as nivalenol and the fumonisins exhibited incomplete extraction. For deoxynivalenol and zearalenone, the trueness of the method was confirmed through the analysis of certified reference materials.  相似文献   

15.
An ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) method has been developed for the simultaneous determination of carvedilol and its pharmacologically active metabolite 4′‐hydroxyphenyl carvedilol in human plasma using their deuterated internal standards (IS). Samples were prepared by solid‐phase extraction using 100 μL human plasma. Chromatographic separation of analytes was achieved on UPLC C18 (50 × 2.1 mm, 1.7 µm) column using acetonitrile‐4.0 mm ammonium formate, pH 3.0 adjusted with 0.1% formic acid (78:22, v/v) as the mobile phase. The multiple reaction monitoring transitions for both the analytes and IS were monitored in the positive electrospray ionization mode. The method was validated over a concentration range of 0.05–50 ng/mL for carvedilol and 0.01‐10 ng/mL for 4′‐hydroxyphenyl carvedilol. Intra‐ and inter‐batch precision (% CV) and accuracy for the analytes varied from 0.74 to 3.88 and 96.4 to 103.3% respectively. Matrix effect was assessed by post‐column analyte infusion and by calculation of precision values (coefficient of variation) in the measurement of the slope of calibration curves from eight plasma batches. The assay recovery was within 94–99% for both the analytes and IS. The method was successfully applied to support a bioequivalence study of 12.5 mg carvedilol tablets in 34 healthy subjects. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
In this study, a specific and sensitive LC–MS/MS method for the simultaneous analysis of type‐B trichothecenes (deoxynivalenol, 3‐acetyldeoxynivalenol, and 15‐acetyldeoxynivalenol) and the de‐epoxy metabolite of deoxynivalenol (de‐epoxy‐deoxynivalenol) in chicken muscle, liver, kidney, and fat tissues was developed and validated. The method involved an extraction step using ethyl acetate, followed by the evaporation of the supernatant, which was further purified by an Oasis HLB SPE cartridge (Waters, Milford, MA, USA). Chromatographic separation was performed on a C18 column by detection with MS in multiple‐reaction monitoring mode and using a gradient elution program with 0.1% formic acid in water and methanol. The correlation coefficients (r) for each calibration curve were >0.99 within the experimental concentration range. The extraction recoveries ranged from 73.7 to 106.4%, with intraday and interday RSD < 11.6% at three levels of concentrations of 2, 10, and 100 μg/kg. The decision limits and the detection capabilities of the analytes in the chicken tissues ranged from 0.16 to 0.92 and 0.68 to 2.07 μg/kg, respectively. The results demonstrated the applicability of this sensitive procedure to the determination of trichothecenes in chicken tissue samples.  相似文献   

17.
In this study, a sensitive hydrophilic interaction liquid chromatography (HILIC) method was developed to determine pseudojervine (PJV), veratrosine (VTS), jervine (JV), veratramine (VTM), veramarine (VA) and veratroylzygadenine (VTG) in rat plasma. Separations were carried out using LC–MS/MS with a Chrom Matrix HP amide column (5 m, 10 cm × 3.0 mm i.d.). The mobile phases were (A) 0.01 mm formic acid and (B) acetonitrile. Good linearity was found for all analytes (R2 > 0.995) in the concentration range from 5 to 1000 μg/L with LLOQ at 5 μg/L for VTM and VTS; and from 1 to 1000 μg/L with LLOQ at 1 μg/L for PJV, JV, VA and VTG. Accuracy of the assay varied from 90.5 to 108.1%. The extraction recovery and matrix effect of six analytes ranged from 72.2 to 95.5% and from 79.2 to 98.4%. According to the stability test, six analytes in rat plasma were stable during the analysis process. On the basis of validation of the assay, the pharmacokinetics of the six steroid alkaloids were investigated after oral administration of Lilu extracts to rats.  相似文献   

18.
A simple and rapid method for the simultaneous determination of seven isoquinoline alkaloids, protopine, chelidonine, coptisine, stylopine, sanguinarine, berberine, and chelerythrine, in Chelidonium majus L. (Ch. majus) samples by ultra‐performance LC method with photodiode array detection is described. The baseline separation of these compounds was performed with (A) acetonitrile–(B) ammonium acetate (10 mM, adjusted to pH 3.0 with acetic acid) as the mobile phase using a C18 RP column (2.1×100 mm, 1.7 μm). Optimized conditions resulted in excellent peak shapes. The seven alkaloids were completely separated within 20 min. Good linear behaviors (r≥0.9992) over the investigated concentration ranges were observed for all the analytes. Validation proved the repeatability of the method was good and recovery was satisfactory. The validated method was successfully applied for 20 batches of Ch. majus. These results demonstrated that the ultra‐performance LC photodiode array method proposed was very useful in the analysis and quality control of Ch. majus.  相似文献   

19.
Uncaria Hook (UH) alkaloids are involved in the beneficial effects of Yokukansan. However, the pharmacokinetics of UH alkaloids after oral administration of Yokukansan has not yet been sufficiently investigated. Therefore, we developed and validated a sensitive and specific high‐performance liquid chromatography with tandem mass spectrometry (LC/MS/MS) method for the simultaneous quantitation of seven UH alkaloids (corynoxeine, isocorynoxeine, rhynchophylline, isorhynchophylline, hirsutine, hirsuteine and geissoschizine methyl ether) in rat plasma and brain. After protein precipitation with acetonitrile, chromatographic separation was performed using an Ascentis Express RP‐amide column, with gradient elution with 0.2% formic acid and acetonitrile at 0.3 mL/min. All analytes in the plasma and brain showed good linearity over a wide concentration range (r > 0.995). Intra‐day and inter‐day variations of each constituent were 8.6 and 8.0% or less in the plasma, and 14.9 and 15.0% or less in the brain, respectively. The validated LC/MS/MS method was applied in the pharmacokinetic studies of UH alkaloids after oral administration of Yokukansan to rats. In the plasma, rhynchophylline, hirsutine, hirsuteine and geissoschizine methyl ether were detected, but only geissoschizine methyl ether was detected in the brain. These results suggest that geissoschizine methyl ether is an important constituent of the pharmacological effects of Yokukansan. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
The application of LC separation and mobile phase additives in addressing LC-MS/MS matrix signal suppression effects for the analysis of pesticides in a complex environmental matrix was investigated. It was shown that signal suppression is most significant for analytes eluting early in the LC-MS analysis. Introduction of different buffers (e.g. ammonium formate, ammonium hydroxide, formic acid) into the LC mobile phase was effective in improving signal correlation between the matrix and standard samples. The signal improvement is dependent on buffer concentration as well as LC separation of the matrix components. The application of LC separation alone was not effective in addressing suppression effects when characterizing complex matrix samples. Overloading of the LC column by matrix components was found to significantly contribute to analyte-matrix co-elution and suppression of signal. This signal suppression effect can be efficiently compensated by 2D LC (LC-LC) separation techniques. The effectiveness of buffers and LC separation in improving signal correlation between standard and matrix samples is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号