首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
In this article, a novel method termed as temperature-assisted ionic liquid dispersive liquid-liquid microextraction (TA IL-DLLME) combining high performance liquid chromatography with diode array detection (HPLC-DAD) was developed for the determination of anthraquinones in Radix et Rhizoma Rhei samples. The ionic liquid (1-hexyl-3-methylimidazolium hexafluorophosphate) was used to replace volatile organic solvent as an extraction solvent for the extraction of anthraquinones (aloe-emodin, rhein, emodin, chrysophanol and physcion) from Radix et Rhizoma Rhei. Several important parameters influencing the extraction efficiency of TA IL-DLLME such as the type and volume of extraction solvent and disperser solvent, sample pH, extraction time, extraction temperature, centrifugation time as well as salting-out effects were optimized. Under the optimal conditions, the spiked recovery for each analyte was in the range of 95.2-108.5%. The precisions of the proposed method were varied from 1.1% to 4.4% (RSD). All the analytes exhibited good linearity with correlation coefficients (r2) ranging from 0.9986 to 0.9996. The limits of detection for all target analytes were ranged from 0.50 to 2.02 μg L−1 (S/N = 3). The experimental results indicated that the proposed method was successfully applied to the analysis of anthraquinones in Radix et Rhizoma Rhei.  相似文献   

2.
溶剂浮选法分离富集大黄中的有效成分   总被引:1,自引:0,他引:1  
采用溶剂浮选法对大黄提取液中的芦荟大黄素、大黄素、大黄酚以及大黄素甲醚进行了分离富集,并用高效液相色谱法分别测定了其含量。考察了料液浓度、浮选溶剂、浮选时间、浮选液pH值、氮气流速和电解质NaCl浓度对浮选效率的影响,并与泡沫浮选法和溶剂萃取法进行了比较。结果表明:溶剂萃取效果最差,泡沫浮选次之,溶剂浮选法分离富集效果最好。当料液浓度为6.4mg/mL,浮选时间为30min,浮选液pH一1~2,氮气流速为20mL/min,电解质NaCl浓度为0.4mol/L时,溶剂浮选效率最佳。  相似文献   

3.
苦黄注射液中大黄蒽醌含量测定方法改进   总被引:2,自引:0,他引:2  
按苦黄注射液原质量标准(草案)中测定方法,大黄蒽醌用氯仿提取,阴性试验结果为苦黄注射液大黄蒽酯标示量的16.50%(n=5),结果偏高;改用石油醚提取,降为6.15%,重复性试验的RSD为1.44%(n=5),加标回收率为101.8%(n=5),显色在1-4h内稳定,表明该法是可行的。  相似文献   

4.
Radix et Rhizoma Asari is a traditional Chinese medicine, and has many pharmacological effects, such as calming, analgesia, anti‐inflammation, antiarrhythmic, antihypertensive, antivirus, etc. But few studies have screened the active compounds from extracts of Radix et Rhizoma Asari for tumor therapy. In this study, a two‐dimensional liquid chromatography system was built to screen active compounds acting on epidermal growth factor receptor (EGFR) from Radix et Rhizoma Asari. The screening result showed that asarinin from Radix et Rhizoma Asari was the targeted component that could act on EGFR specificity. The competitive binding assay and molecular docking assay results showed asarinin binding with EGFR in similar manner as with gefitinib, which was used as a positive control drug. Then the antitumor effect of asarinin was studied through cell growth assay in vitro. The results showed that gefitinib and asarinin could inhibit highly expressed EGFR cell growth in a dose‐dependent manner in the range of dose from 0.10 to 102.4 μM. This two‐dimensional liquid chromatography system will be a useful method in drug discovery from natural medicinal herbs for searching potential antitumor candidates.  相似文献   

5.
A fast method for simultaneous determination of five compounds (one coumarin, two alkaloids and two bibenzyls) in Dendrobium spp. using pressurized liquid extraction and ultra‐performance liquid chromatography coupled with photo diode array detection was developed. The separation was performed on an Acquity UPLC BEH C18 column (50 mm×2.1 mm id, 1.7 μm) with gradient elution of phosphate buffer (pH=7.1, 20 mM) and acetonitrile within 6 min. The method was validated for linearity, LOD and LOQ, precision and accuracy. All calibration curves showed good linearity (R2≥0.9999) within test ranges. The overall intra‐ and inter‐day variations (RSDs) of five analytes were less than 2.5%, and the detection recoveries were between 95.6 and 102.3%. The developed method was successfully applied to quantitative analysis of five investigated compounds in different species of Dendrobium. The results showed that there were great variations of their contents, though all these materials were officially used as Chinese herb, Shihu. In addition, the chromatographic fingerprints of Dendrobium spp. were also investigated.  相似文献   

6.
色谱指纹谱用于中药大黄抗肿瘤活性成分的筛选   总被引:2,自引:0,他引:2  
采用液相色谱-质谱联用方法分析了中药大黄经过SD大鼠肝匀浆体外代谢前后的指纹谱中色谱峰面积、保留值的差异。指出5种游离型蒽醌化合物在SD大鼠肝匀浆体外代谢体系中只有大黄酚发生代谢反应转化为芦荟大黄素。考察了体外代谢条件下,肝匀浆浓度与代谢时间对大黄酚转化及其代谢产物的影响。SD大鼠体外抗肿瘤试验表明,大黄代谢物对于人宫颈癌(HeLa)细胞的抑制活性略高于其提取物。通过比较芦荟大黄素、大黄酸、大黄素、大黄酚、大黄素甲醚的活性,并结合大黄酚的体外代谢反应的考察,解释了大黄代谢物对肿瘤细胞活性的抑制率的提高是由大黄酚的代谢产物芦荟大黄素浓度的增加引起的。  相似文献   

7.
The aim of this study was to investigate the influence of compatibility on the contents of main compounds in Paeoniae Radix Alba and Atractylodis Macrocephalae Rhizoma. Ten compounds were separated on an Inertsil ODS‐SP Extend C18 column (250 mm × 4.6 mm, 5 μm) and detected by a diode array detector with the mobile phase consisting of aqueous phosphoric acid (0.1%, v/v; A) and acetonitrile (B) by linear gradient elution. All analytes showed good linearity over a wide concentration range (r2 ≥ 0.9989). The limits of detection and quantification were <8.10 and 10.80 μg/mL, respectively. The intra‐ and interday variations were <4.36%. The average recoveries were observed from 94.90 to 103.38%, with relative standard deviation ranging from 1.23 to 3.15% for the analytes. The established method was reliable enough for global quality evaluation of Paeoniae Radix Alba, Atractylodis Macrocephalae Rhizoma, and their co‐decoctions.  相似文献   

8.
Benzotriazole UV stabilizers are emerging compounds used in personal care products and can enter surface water after passing through wastewater treatment plants without being removed. Because these analytes are strongly hydrophobic, there is an environmental risk of accumulation in solid matrices and magnification through the trophic chain. In this work, a method based on stir bar sorption extraction with liquid desorption is presented for the extraction of benzotriazole UV stabilizers from water samples. Stir bar sorptive extraction was combined with ultra‐high performance LC with MS/MS detection. All important factors affecting the stir bar sorptive extraction procedure are discussed, and the optimized method was applied to seawater and wastewater samples from Gran Canaria Island, providing good selectivity and sensitivity with LODs and limits of quantification in the range of 18.4–55.1 and 61.5–184 ng/L, respectively. Recoveries between 68.4–92.2% were achieved for the more polar compounds, whereas the recoveries were lower for the two less polar compounds, most likely due to their strong absorption into the polydimethylsiloxane stir bar phase that does not allows the complete desorption. The repeatability studies gave RSDs of between 6.45 and 12.6% for all compounds in the real samples.  相似文献   

9.
An efficient method using ultra‐performance LC coupled with triple quadrupole MS was developed for the rapid determination of 12 major active components in Pien Tze Huang (PZH), a well‐known traditional Chinese formula. Chromatographic separation was achieved on a Waters XBridge BEH RP18 column (50 mm × 2.1 mm id, 1.7 μm) with a gradient mobile phase (A: 0.1% aqueous formic acid and B: acetonitrile with 0.1% formic acid) at a flow rate of 0.8 mL/min. The chromatographic peaks of 12 components were identified by comparing their retention time and MS data with the related reference compounds. Multiple‐reaction monitoring was employed for the quantitative analysis. Ten batches of PZH were analyzed with a good linear regression relationship (r, 0.9987–0.9995), intraday precisions (RSD, 2.05–4.80%), interday precisions (RSD, 1.99–4.98%), repeatability (RSD, 2.21–4.20%), stability (RSD, 3.52–4.81%), and recovery (95.63–104.80%). By using this established method, the present study offered highly sensitive, specific, and speedy determination of 12 major components, which promoted the quality control investigation of PZH greatly.  相似文献   

10.
Benzotriazole ultra‐violet stabilisers are compounds widely used in personal care products, which can reach the environment after passing through wastewater treatment plants. In this work, we develop a novel method to evaluate the presence of seven compounds in marine sediments and sewage sludges using microwave‐assisted extraction followed by a clean‐up step based in on‐line solid phase extraction coupled to ultra‐high‐performance liquid chromatography with MS/MS detection. This method allows for fast and efficient extraction from the solid matrix, subsequent automatic on‐line purification and preconcentration, and analysis. For the optimised method, LOD were from 53.3 to 146 ng/kg and LOQ were in the range of 176–486 ng/kg. The method was validated for different environmental solid samples with satisfactory recoveries and relative standard deviations, between 46.1 and 83.9 and 7.8 and 15.5% (sludges) and 50.1 and 87.1% and 8.83 and 16.3% (sediments), respectively. Finally, the studied analytes were quantified in concentrations between 0.18 and 24.0 ng/g in real samples of marine sediments and sewage sludges from Gran Canaria Island (Spain).  相似文献   

11.
An ultra‐performance LC in combination with MS/MS method was established to evaluate the quality of Wu‐yao (the dried root of Lindera aggregata (Sims) Kosterm. (Lauraceae)) through simultaneous quantitation of five sesquiterpene lactones, linderagalactone D ( 1 ), linderagalactone C ( 2 ), hydroylindestenolide ( 3 ), neolinderalactone ( 4 ) and linderane ( 5 ). All compounds were separated on a Waters Acquity ultra‐performance LC HSS T3 column (2.1 mm×100 mm, 1.8 μm particle size) with linear gradient elution of acetonitrile and 0.1% formic acid. An ESI interface in the positive mode was employed prior to MS detection. All the compounds showed good linearity (R2≥0.9992). The recoveries, measured at three concentration levels, varied from 97.3 to 103.4% with RSDs <4.8%. The simple, rapid and reliable method was successfully applied to quantify the five components in 13 samples of Wu‐yao from different areas.  相似文献   

12.
A high-performance liquid chromatographic (HPLC) method coupled with ultraviolet (UV) and electrospray ionization time-of-flight mass spectrometry (ESI-TOF/MS) was established for simultaneous qualitative and quantitative determination of nine phenolic acids and six diterpenoids in Radix et Rhizoma Salviae Miltiorrhizae (RRSM). The optimal chromatographic conditions were achieved on a Zorbax C(18) column by gradient elution with 0.1% (v/v) aqueous formic acid and acetonitrile as mobile phase at the flow rate of 1.0 mL/min. The detection wavelength at 281 nm was chosen to determine the 15 bioactive components, namely danshensu (1), protocatechuic acid (2), protocatechuic aldehyde (3), caffeic acid (4), rosmarinic acid (5), lithospermic acid (6), salvianolic acid B (7), salvianolic acid A (8), salvianolic acid C (9); dihydrotanshinone I (10), cryptotanshinone (11), tanshinone I (12), methylene tanshiqunone (13), tanshinone IIA (14) and miltirone (15). Additionally, LC-ESI-TOF/MS was used to make definite identification of the constituents in samples in comparison with those reference compounds. The validation of the method included tests of linearity, sensitivity, repeatability, stability and recovery. The proposed method was successfully applied to quantify the 15 components in 21 samples; significant variations were demonstrated in the contents of the samples from diverse species and origins. The developed method could be used to effectively and comprehensively evaluate the quality of RRSM for its clinical safety and efficacy.  相似文献   

13.
Saflufenacil is a new protoporphyrinogen‐IX‐oxidase inhibitor herbicide. When used, it can enter the soil and has a high risk to reach and contaminate groundwater and aquatic systems. A rapid and sensitive method of ultra‐performance LC with MS/MS was developed for the simultaneous determination of saflufenacil and its two metabolites in soil samples. A modified quick, easy, cheap, effective, rugged, and safe method was applied as the pretreatment procedure. The method was validated by five types of soil samples collected from several regions of China, which all showed good linearity (R2 ≥ 0.9914) and precision (RSD ≤ 26.2%). The average recoveries of the three analytes ranged between 74.1 and 118.9% at spiking levels of 3–300 μg/kg. The method limits of detection (S/N 3:1) and method limits of quantification (S/N 10:1) achieved are in the ranges of 0.25–2.75 and 0.83–9.16 μg/kg, respectively. This indicated that the developed ultra‐performance LC with MS/MS method is a promising analytical tool for monitoring the environmental risks posed by saflufenacil.  相似文献   

14.
A new fast and effective analysis method has been developed to simultaneously determine 16 polycyclic aromatic hydrocarbons in reclaimed water samples by ultra‐performance convergence chromatography with photodiode array detection and solid‐phase extraction. The parameters of ultra‐performance convergence chromatography on the separation behaviors and the crucial condition of solid‐phase extraction were investigated systematically. Under optimal conditions, the 16 polycyclic aromatic hydrocarbons could be separated within 4 min. The limits of detection and quantification were in the range of 0.4–4 and 1–10 μg/L in water, respectively. This approach has been applied to a real industrial wastewater treatment plant successfully. The results showed that polycyclic aromatic hydrocarbons were dramatically decreased after chemical treatment procedure, and the oxidation procedure was effective to remove trace polycyclic aromatic hydrocarbons.  相似文献   

15.
In this work, various types of metal‐organic frameworks were synthesized, and their affinities toward buprenorphine were evaluated using dispersive solid‐phase extraction. The extracted buprenorphine was determined by ultra high performance liquid chromatography‐ultraviolet detection system. The highest extraction recovery was observed by employing zeolitic imidazole framework‐67. Then, a facile and fast extraction method was designed for the extraction and purification of the target drug. Optimization of the extraction method was carried out by the design of experiment approach. A linearity range of 1–1000 μg/L with the limit of detection of 0.15 μg/L and relative standard deviations (50 μg/L, n = 5) of 3.4% was obtained for standard sample analysis. Under optimized experimental and instrumental conditions, the relative recoveries were in the range of 95 to 111%. Eventually, zeolitic imidazole framework‐67 was successfully employed for the extraction and determination of buprenorphine in the biological fluids with satisfactory results.  相似文献   

16.
An approach for rapid optimization of dual-mode gradient high performance liquid chromatography (HPLC) by response surface methodology (RSM) was developed for fast simultaneous separation of hydrophilic and hydrophobic components in Radix et Rhizoma Salviae Miltiorrhizae (Danshen) and its preparations. The aim of this study was to achieve a high throughput RSM optimization using a short ultra-high performance liquid chromatographic (UHPLC) column to simultaneously optimize flow rate and solvent gradient, and then transfer the optimized method to conventional HPLC for routine analytical purposes. The optimization was designed with Box Behnken design (BBD) and the global Derringer's desirability was used for describing the multicriteria response variables. Sixty-two designed experiments were performed by UHPLC with a short sub-2 μm column (2.1 mm × 50 mm, 1.7 μm) and a total running time of only 5 h. The predicted gradient profile was further transferred to a long UHPLC column (2.1 mm × 100 mm, 1.7 μm) and a conventional HPLC columns (2.1 mm × 100 mm, 3.5 μm and 4 mm × 100 mm, 5 μm, respectively). Compared to the published methods, the newly developed dual-mode gradient is faster and more efficient at simultaneously separating hydrophilic and hydrophobic components in Danshen and its preparations.  相似文献   

17.
Graphene‐based pipette tip solid‐phase extraction was combined with ultra‐high performance liquid chromatography and tandem mass spectrometry for the determination of carbamate pesticide residues in fruit juice samples. Four milligrams of graphene was used as sorbent material to pack a 1000 μL pipette tip for the extraction of pirimicarb, propoxur, isoprocarb, fenobucarb, and diethofencarb from 3 mL of fruit juice sample. The whole extraction process was finished in 12 min, and the volume of eluent used was only 1.5 mL. Under the optimized conditions, good linear relationship (R > 0.999) and lower limits of detection (0.0022–0.033 ng/mL) were achieved. The recoveries at three spiked levels ranged from 80.90 to 124.60% with relative standard deviations less than 4.88%. Compared with commercially available sorbents including propylsulfonic acid silica, graphitized carbon black, and C18, graphene was superior in extraction efficiency. The proposed method is simple, rapid, sensitive, selective, and solvent saving.  相似文献   

18.
A method based on accelerated solvent extraction combined with rapid‐resolution LC–MS for efficient extraction, rapid separation, online identification and accurate determination of the saikosaponins (SSs) in Radix bupleuri (RB) was developed. The RB samples were extracted by accelerated solvent extraction using 70% aqueous ethanol v/v as solvent, at a temperature of 120°C and pressure of 100 bar, with 10 min of static extraction time and three extraction cycles. Rapid‐resolution LC separation was performed by using a C18 column at gradient elution of water (containing 0.5% formic acid) and acetonitrile, and the major constituents were well separated within 20 min. A TOF‐MS and an IT‐MS were used for online identification of the major constituents, and 27 SSs were identified or tentatively identified. Five major bioactive SSs (SSa, SSc, SSd, 6″‐O‐acetyl‐SSa and 6″‐O‐acetyl‐SSd) with obvious peak areas and good resolution were chosen as benchmark substances, and a triple quadrupole MS operating in multiple‐reaction monitoring mode was used for their quantitative analysis. A total of 16 RB samples from different regions of China were analyzed. The results indicated that the method was rapid, efficient, accurate and suitable for use in the quality control of RB.  相似文献   

19.
Matrix effects in determination of three β‐receptor agonists including salbutamol (SAL), clenbuterol, and terbutaline in animal‐derived foodstuffs were studied by ultra‐performance LC‐MS/MS with cleanup of immunoaffinity SPE column (IAC). Some animal tissue samples including pig liver, swine muscle, and fish muscle were hydrolyzed by the mixed enzyme solution or HCl solution, and the cleanup efficiencies with SAL IAC, MCX SPE column, and C18‐SCX tandem columns were examined and compared by using spiked experiments. The results showed that the matrix effects in the determination of SAL and terbutaline can be eliminated with SAL IAC cleanup, and the average recoveries of SAL were 77.4~81.5%, 79.0~80.3%, and 85.0~87.2% in pig liver, swine muscle, and fish muscle, respectively. The decision limit (ccα) and detection capability (ccβ) for SAL in pig liver were 0.02 and 0.05 μg/kg, respectively.  相似文献   

20.
赵唐娟  陈娟  师彦平 《色谱》2017,35(1):32-46
针对中药复方制剂六味地黄丸的质量控制提出了一种多指标全药材整体分析新策略。从组成六味地黄丸的每一味药材中选取1~2个药效成分,即选取熟地黄中的毛蕊花糖苷、山茱萸中的莫诺苷和马钱苷、牡丹皮中的丹皮酚和芍药苷、山药中的尿囊素、茯苓中的茯苓酸、泽泻中的23-乙酰泽泻醇B作为六味地黄丸的质量控制指标成分,采用快速、简便、高效的超声细胞粉碎提取(UCGE)法对这8个指标成分进行同步提取。用响应曲面分析中的Box-Behnken模式对UCGE提取过程中对提取效率影响较大的料液比、提取时间和提取温度等参数进行了优化。得到最优的提取条件:料液比1∶45(g/mL)、提取时间40 min、提取温度20℃。进一步利用超高效液相色谱-二极管阵列检测(UPLC-PAD)技术实现多指标成分在同一根色谱柱上的同步分离和检测,从而建立六味地黄丸的多指标全药材整体色谱。采用HSS T3色谱柱(50 mm×2.1 mm,1.8μm),以乙腈-水为流动相进行梯度洗脱,基于指标成分的紫外光谱特征选择5个检测波长同时检测,并进行了线性关系、检出限、定量限、精密度、稳定性、重复性、准确性等方法学验证。该研究为六味地黄丸质量标准的建立提供了依据,同时也为中药复方制剂提供了一种质量控制新模式和新理念。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号