首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A fast and easy tailored dispersive solid‐phase extraction (d‐SPE) procedure has been developed for the determination of 13 cytostatic drugs. Combined with a rapid and simultaneous ultra performance liquid chromatography/tandem mass spectrometry method for residue identification and quantification in urine, it has been fully validated and tested to study a realistic situation in working environment. The target compounds were chosen from the most common classes used in hospitals. The d‐SPE adsorbent was obtained mixing Oasis HLB® with C18 and applied to a large volume of sample (10 mL). The electrospray ionization‐mass spectrometry acquisition was conducted in a mixed period mode: six acquisition windows were in positive ionization and one in negative (for 5‐fluorouracil). The lowest limit of quantification was found at 0.04 μg/L urine for methotrexate. The absolute recovery of cytotoxic drugs was assessed at two concentrations levels and ranged from 67.1% (cytarabine) to 102.3% (etoposide) and from 65.3% (cytarabine) to 101.2% (methotrexate) for the lower and higher levels, respectively, with the relative standard deviation always <12%. This method gives the opportunity to analyze drugs in a wide molecular weight range (from 130 to 853 a.m.u.) and in a complex matrix, such as urine, without losing any of the features that a method intended for trace quantification must have. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

2.
A liquid chromatographic–electrospray ionization–time‐of‐flight/mass spectrometric (LC‐ESI‐TOF/MS) method was developed and applied for the determination of WKYMVm peptide in rat plasma to support preclinical pharmacokinetics studies. The method consisted of micro‐elution solid‐phase extraction (SPE) for sample preparation and LC‐ESI‐TOF/MS in the positive ion mode for analysis. Phenanthroline (10 mg/mL) was added to rat blood immediately for plasma preparation followed by addition of trace amount of 2 m hydrogen chloride to plasma before SPE for stability of WKYMVm peptide. Then sample preparation using micro‐elution SPE was performed with verapamil as an internal standard. A quadratic regression (weighted 1/concentration2), with the equation y = ax2 + bx + c was used to fit calibration curves over the concentration range of 3.02–2200 ng/mL for WKYMVm peptide. The quantification run met the acceptance criteria of ±25% accuracy and precision values. For quality control samples at 15, 165 and 1820 ng/mL from the quantification experiment, the within‐run and the between‐run accuracy ranged from 92.5 to 123.4% with precision values ≤15.1% for WKYMVm peptide from the nominal values. This novel LC‐ESI‐TOF/MS method was successfully applied to evaluate the pharmacokinetics of WKYMVm peptide in rat plasma.  相似文献   

3.
A sensitive, selective and robust liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed for the quantification of miglitol in rat plasma. The sample preparation procedures involved protein precipitation and unique solid‐phase extraction, which efficiently removed sources of ion suppression and column degradation interference present in the plasma. Chromatographic separation was achieved on an amide column using 10 mmol/L CH3COONH4 and CH3CN:CH3OH (90:10, v/v) as the mobile phase under gradient conditions. Detection was performed using tandem mass spectrometry equipped with an electrospray ionization interface in positive ion mode.The selected reaction monitoring transitions for miglitol and a stable isotope‐labeled internal standard were m/z 208 → m/z 146 and m/z 212 → m/z 176, respectively. The correlation coefficients of the calibration curves ranged from 0.9984 to 0.9993 over a concentration range of 0.5–100 ng/mL plasma. The quantification limit of the proposed method was more than 10 times lower than those of previously reported LC‐MS/MS methods. The novel method was successfully validated and applied to a pharmacokinetic study in rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
A gas chromatography–mass spectrometry method was developed and validated for the simultaneous automated solid‐phase extraction and quantification of cotinine and trans‐3‐hydroxycotinine in human urine. Good linearity was observed over the concentration ranges studied (R2 > 0.99). The limit of quantification was 10 ng/mL for both analytes. The limits of detection were 0.06 ng/mL for cotinine (COT) and 0.02 ng/mL for trans‐3‐hydroxycotinine (OH‐COT). Accuracy for COT ranged from 0.98 to 5.28% and the precision ranged from 1.24 to 8.78%. Accuracy for OH‐COT ranged from ?2.66 to 3.72% and the precision ranged from 3.15 to 7.07%. Mean recoveries for cotinine and trans‐3‐hydroxycotinine ranged from 77.7 to 89.1%, and from 75.4 to 90.2%, respectively. This analytical method for the simultaneous measurement of cotinine and trans‐3‐hydroxycotinine in urine will be used to monitor tobacco smoking in pregnant women and will permit the usefulness of trans‐3‐hydroxycotinine as a specific biomarker of tobacco exposure to be determined. © 2014 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd.  相似文献   

5.
A liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of GDC‐0152 in human plasma to support clinical development. The method consisted of a solid‐phase extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d7‐GDC‐0152 was used as the internal standard. A linear regression (weighted 1/concentration2) was used to fit calibration curves over the concentration range of 0.02–10.0 ng/mL for GDC‐0152. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 99.3% with a precision (%CV) of 13.9%. For quality control samples at 0.0600, 2.00 and 8.00 ng/mL, the between‐run %CV was ≤8.64. Between‐run percentage accuracy ranged from 98.2 to 99.6%. GDC‐0152 was stable in human plasma for 363 days at ?20°C and for 659 days at ?70°C storage. GDC‐0152 was stable in human plasma at room temperature for up to 25 h and through three freeze–thaw cycles. In whole blood, GDC‐0152 was stable for 12 h at 4°C and at ambient temperature. This validated LC‐MS/MS method for determination of GDC‐0152 was used to support clinical studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
A fast and simple screening procedure using solid‐phase microextraction and gas chromatography‐mass spectrometry (SPME‐GC‐MS) in full‐scan mode for the determination of volatile organic compounds (VOC) is presented. The development of a fast and simple screening technique for the simultaneous determination of various volatiles is of great importance, because of their widespread use, frequent occurrence in forensic toxicological questions and the fact that there is often no hint on involved substances at the crime scene. To simulate a screening procedure, eight VOC with different chemical characteristics were chosen (isoflurane, halothane, hexane, chloroform, benzene, isooctane, toluene and xylene). To achieve maximum sensitivity, variables that influence the SPME process, such as type of fiber, extraction and desorption temperature and time, agitation and additives were optimized by preliminary studies and by means of a central composite design. The limits of detection and recoveries ranged from 2.9 µg/l (xylene) to 37.1 µg/l (isoflurane) and 7.9% (chloroform) to 61.5% (benzene), respectively. This procedure can be used to answer various forensic and toxicological questions. The short time taken for the whole analytical procedure may make its eventual adoption for routine analysis attractive. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
A headspace solid‐phase micro‐extraction (HS‐SPME) method was employed in order to study the effect of storage conditions of human urine samples spiked with tributyltin (TBT) using gas chromatography and mass spectrometry. To render the analyte more volatile, the derivatization (ethylation) was made in situ by sodium tetraethylborate (NaBEt4), which was added directly to dilute unpreserved urine samples and in buffers of similar acidity. The stability of TBT in human urine matrix was compared with the stability of TBT in buffer solutions of similar pH value. Critical parameters of storage conditions such as temperature and time, which affect the stability of TBT in this kind of matrix, were examined extensively. The tests showed that the stability of TBT remains practically satisfactory for a maximum of 2 days of storage either at +4 or 20°C. Greater variations were observed in the concentration of TBT in human urine samples at +4°C and lower ones at ?20°C over a month's storage. The freeze–thaw cycles have negative effect on the stability and should be kept to a minimum. The results from spiked urine samples are also discussed in comparison to those acquired from buffer solutions of equal TBT concentration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
An efficient and sensitive multiresidue method has been developed for quantification and confirmation of 25 phenyl acetanilide pesticides in a wide variety of food commodities including maize, spinach, mushroom, apple, soybean, chestnut, tea, beef, cattle liver, chicken, fish, and milk. Analytes were extracted with acetone–n‐hexane (1:2, v/v) followed by cleanup using SPE. Several types of adsorbents were evaluated. Neutral aluminum and graphitized carbon black cartridge showed good cleanup efficiency. The extract was determined by GC‐MS in the selected ion monitoring mode using one target and two qualitative ions for each analyte. The limits of detection were 0.01 mg/kg for all analytes. The average recoveries ranged from 66.9 to 110.6% (mean 88.8%) and RSDs were in the range 2.0–19% (mean 10.5%) across three fortification levels. The proposed method was successfully applied to real samples in routine analysis and a satisfactory result was obtained.  相似文献   

9.
A gas chromatography–mass spectrometry assay was developed and validated for the simultaneous determination of phthalates and adipates in human serum. The phthalates and adipates studied were dimethyl phthalate, diethyl phthalate, dibutyl phthalate, benzylbutyl phthalate, di‐2‐ethylhexyl phthalate, di‐n‐octyl phthalate, diethyl adipate, dibutyl adipate, diisobutyl adipate, bis(2‐butoxyethyl) adipate and di‐2‐ethylhexyl adipate, with diisooctyl phthalate as internal standard. The extraction and cleaning up procedure was carried out with solid‐phase extraction cartridges containing dimethyl butylamine groups, which showed extraction efficiencies over 88% for each analyte and the internal standard. The calibration curves obtained were linear with correlation coefficients greater than 0.98. For all analytes, the assay gave CV% values for intra‐day precision from 4.9 to 13.3% and mean accuracy values from 91.4 to 108.4%, while inter‐day precision was 5.2–13.4% and mean accuracy 91.0–110.2%. The limits of detection for the assay of phthalates and adipates were in the range 0.7–4.5 ng/mL. The method is simple, sensitive and accurate, and allows for simultaneous determination of nanogram levels of phthalates and adipates in human serum. It was successfully applied to an investigation on the level of phthalates and adipates in a non‐occupationally exposed population.  相似文献   

10.
A simple and complete multiresidue method has been developed for the routine determination of 236 pesticides and degradation products, in meat based baby‐food. This original approach combines a modified Quick Easy Cheap Effective Rugged and Safe (QuEChERS) sample preparation method using a triple partitioning extraction step with water/ACN/hexane and a system composed of GC with programmable temperature vaporization injector hyphenated to an IT‐MS. Detection was performed in full scan mode, with one quantification ion and one identification ion. We firstly report here the hexane addition in the extraction step to eliminate a major part of lipophile co‐extracts. Direct consequences were the increasing of method sensitivity and the diminishment of the frequency of maintenance of the analytical instrument. The recovery data were obtained by spiking blank samples at three concentration levels (10, 50 and 200 μg/kg) over five replicates, yielding average recoveries in the range 70–121% with a RSD evaluated between 2–15%. Linearity was fixed in the range of 10–300 μg/kg with determination coefficients (R2) superior or equal to 0.9814 for all target analytes. Best LODs and LOQs were established as 0.03 and 0.1 μg/kg, respectively. Total instrumental analysis of all molecules was carried out in less than 1 h.  相似文献   

11.
Using bamboo‐activated charcoal as SPE adsorbent, a novel SPE method was developed for the sensitive determination of tetrabromobisphenol A and bisphenol A in environmental water samples by rapid‐resolution LC‐ESI‐MS/MS. Important parameters influencing extraction efficiency, including type of eluent, eluent volume, sample pH, volume and flow rate, were investigated and optimized. Under the optimal extraction conditions (eluent: 8 mL methanol, pH: 7; flow rate: 4 mL/min; sample volume: 100 mL), low LODs (0.01–0.02 ng/mL), good repeatability (6.2–8.3%) and wide linearity range (0.10–10 ng/mL) were obtained. Satisfied results were achieved when the proposed method was applied to determine the two target compounds in real‐world environmental water samples with spiked recoveries over the range of 80.5–119.8%. All these facts indicate that trace determination of tetrabromobisphenol A and bisphenol A in real‐world environmental water samples can be realized by bamboo‐activated charcoal SPE‐rapid resolution‐LC‐ESI‐MS/MS.  相似文献   

12.
An easy‐to‐handle magnetic dispersive solid‐phase extraction procedure was developed for preconcentration and extraction of cocaine and cocaine metabolites in human urine. Divinyl benzene and vinyl pyrrolidone functionalized silanized Fe3O4 nanoparticles were synthesized and used as adsorbents in this procedure. Scanning electron microscopy, vibrating sample magnetometry, and infrared spectroscopy were employed to characterize the modified adsorbents. A high‐performance liquid chromatography with mass spectrometry method for determination of cocaine and its metabolites in human urine sample has been developed with pretreatment of the samples by magnetic dispersive solid‐phase extraction. The obtained results demonstrated the higher extraction capacity of the prepared nanoparticles with recoveries between 75.1 to 105.7% and correlation coefficients higher than 0.9971. The limits of detection for the cocaine and cocaine metabolites were 0.09–1.10 ng/mL. The proposed magnetic dispersive solid‐phase extraction method provided a rapid, environmentally friendly and magnetic stuff recyclable approach and it was confirmed that the prepared adsorbents material was a kind of highly effective extraction materials for the trace cocaine and cocaine metabolites analyses in human urine.  相似文献   

13.
A simple, sensitive, and selective molecularly imprinted solid‐phase extraction and spectrophotometric method has been developed for the clean‐up and preconcentration of indapamide from human urine. Molecularly imprinted polymers were prepared by a non‐covalent imprinting approach using indapamide as a template molecule, 2‐(trifluoromethyl) acrylic acid as a functional monomer, ethylene glycol dimethacrylate as a crosslinker, N,N‐azobisisobutyronitrile as a thermal initiator and acetonitrile as a porogenic solvent. A non‐imprinted polymer was also prepared in the same way, but in the absence of template. Molecularly imprinted polymer and non‐imprinted polymer sorbents were dry‐packed into solid‐phase extraction cartridges. Eluates from cartridges were analyzed using a spectrophotometer for the determination of indapamide by referring to the calibration curve in the range 0.14–1.50 μg/mL. Preconcentration factor, limit of detection, and limit of quantification were 16.30, 0.025 μg/mL, and 0.075 μg/mL, respectively. A relatively high imprinting factor (9.3) was also achieved and recovery values for the indapamide spiked into human urine were in the range of 80.1–81.2%. In addition, relatively low within‐day (0.17–0.42%) and between‐day (1.1–1.4%) precision values were obtained as well. The proposed molecularly imprinted solid‐phase extraction and spectrophotometric method was successfully applied to selective extraction, preconcentration, and determination of indapamide from human urine samples.  相似文献   

14.
Perilla leaves contain many interfering substances; thus, it is difficult to protect the analytes during identification and integration. Furthermore, increasing the amount of sample to lower the detection limit worsens the situation. To overcome this problem, we established a new method using a combination of solid‐phase extraction and dispersive solid‐phase extraction to analyze pyraclostrobin in perilla leaves by liquid chromatography with ultraviolet absorbance detection. The target compound was quantitated by external calibration with a good determination coefficient (R2 = 0.997). The method was validated (in triplicate) with three fortification levels, and 79.06– 89.10% of the target compound was recovered with a relative standard deviation <4. The limits of detection and quantification were 0.0033 and 0.01 mg/kg, respectively. The method was successfully applied to field samples collected from two different areas at Gwangju and Muan. The decline in the resiudue concentrations was best ascribed to a first‐order kinetic model with half‐lives of 5.7 and 4.6 days. The variation between the patterns was attributed to humidity. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
A liquid chromatographic mass spectrometric assay for the quantification of azithromycin in human plasma was developed. Azithromycin and imipramine (as internal standard, IS) were extracted from 0.5 mL human plasma using extraction with diethyl ether under alkaline conditions. Chromatographic separation of drug and IS was performed using a C18 column at room temperature. A mobile phase consisting of methanol, water, ammonium hydroxide and ammonium acetate was pumped at 0.2 mL/min. The mass spectrometer was operated in positive ion mode and selected ion recording acquisition mode. The ions utilized for quantification of azithromycin and IS were m/z 749.6 (M + H) + and m/z 591.4 (fragment) for azithromycin, and 281.1 m/z for internal standard; retention times were 6.9 and 3.4 min, respectively. The calibration curves were linear (r2 > 0.999) in the concentration ranges of 10–1000 ng/mL. The mean absolute recoveries for 50 and 500 ng/mL azithromycin and 1 µg/ mL IS were >75%. The percentage coefficient of variation and mean error were <11%. Based on validation data, the lower limit of quantification was 10 ng/mL. The present method was successfully applied to determine azithromycin pharmacokinetic parameters in two obese volunteers. The assay had applicability for use in pharmacokinetic studies. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
A simple LC‐MS/MS method was developed and validated for quantitatively analyzing six classes of 26 abused drugs and metabolites in human urine: (1) illicit drugs; (2) opiates; (3) synthetic opioids; (4) sedative; (5) stimulants; and (6) γ‐aminobutyric acid analogs. All urine samples were diluted with a mixture of isotope‐labeled internal standards, hydrolyzed with β‐glucuronidase and directly injected in a gradient chromatographic run. The mobile phase was composed of 0.1% formic acid in water and 0.1% of formic acid in methanol. A 4.9 min run time using the multiplexing driver and ultra‐biphenyl column (50 × 2.1 mm, 5 µm, RESTEK) allowed all drugs to have sufficient resolution in a short elute time. The overlapping liquid chromatography runs and scheduled multiple reaction monitoring acquisition method resulted in a higher overall throughput for the system. The result was linear over the studied range (2–16,000 ng/mL) for all compounds with correlation coefficients r2 ≥ 0.995. The intra‐day and inter‐day precisions and accuracies were within 15% and recovery was between 83 and 115% for all analytes. Freeze–thaw stability for three cycles and long‐term stability (57 days, ?20°C) were established for all analytes. The cross‐validation between College of American Pathologists and in‐house was validated (0.06% ≤ bias ≤ 12.3%). The applicability of the method was examined by analyzing urine samples from chronic pain patients (n = 610). Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
The antipsychotics risperidone, aripiprazole and pipamperone are frequently prescribed for the treatment in children with autism. The aim of this study was to validate an ultra‐high performance liquid chromatography–mass spectrometry method for the quantification of these antipsychotics in plasma. An ultra‐high performance liquid chromatography–mass spectrometry assay was developed for the determination of the drugs and metabolites. Gradient elution was performed on a reversed‐phase column with a mobile phase consisting of ammonium acetate, formic acid in methanol or in Milli‐Q ultrapure water at a flow rate of 0.5 mL/min. The method was validated according to the US Food and Drug Administration guidelines. The analytes were found to be stable enough after reconstitution and injection of only 5 μL improved the accuracy and precision in combination with the internal standard. Calibration curves of all five analytes were linear. All analytes were stable for at least 72 h in the autosampler and the high quality control of 9‐OH‐risperidone was stable for 48 h. The method allows quantification of all analytes. The advantage of this method is the combination of a minimal injection volume, a short run‐time, an easy sample preparation method and the ability to quantify all analytes in one run. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
In a study aiming to characterize cork off‐flavour for quality control purposes, chloroanisoles were extracted and identified from cork stoppers by means of solid‐phase microextraction (SPME)–gas chromatography–ion‐trap mass spectrometry (GC–ITMS). An experimental design procedure was used to investigate the effects of some experimental parameters on the SPME of 2,4‐dichloroanisole, 2,6‐dichloroanisole, and 2,4,6‐trichloroanisole from cork stoppers by using a Carboxen‐PDMS 75 μm fibre. Variables such as extraction temperature, extraction time, and percentage of ethanol added to the matrix were optimized to improve extraction efficiency of chloroanisoles onto SPME fibre. Instrumental analysis was performed by GC–ITMS in the MS/MS mode. Preliminary analyses on standard solutions allowed selection of the appropriate ionization mode (i. e. electron impact or chemical ionization), providing for each analyte the highest instrumental response. In order to find polynomial functions describing the relationships between variables and responses, the analytical responses, i.e. the chromatographic peak areas, were processed by using the backward multiple regression analysis. For all the analytes the operating conditions providing the highest extraction yield inside the experimental domain considered were found.  相似文献   

19.
A method based on liquid chromatography with electrospray ionization high‐resolution mass spectrometry (Exactive Orbitrap) combined with solid‐phase extraction using a strong cationic exchange mixed‐mode sorbent has been developed for the determination of seven drugs of abuse, including two synthetic cathinones, as well as some of their metabolites in environmental water samples. The method provides low detection limits and a high confirmation power thanks to the diagnostic and two fragment ions monitored for each compound in high‐resolution mass spectrometry, providing six identification points for each analyte. The clean‐up step based on methanol in the extraction step adequately decreased the matrix effect, mainly for river and effluent water, and provided suitable process efficiency. Method detection and quantitation limits for environmental waters were at low nanogram per liter. The method was applied to analyze the samples of influent and effluent wastewater, as well as surface water. Codeine, methadone, and its metabolite were determined in all samples of wastewater and the metabolite of cocaine, benzoylecgonine, was found at the highest concentration.  相似文献   

20.
The abundant production of methyl tert‐butyl ether (MTBE) and its widespread use have led to an increase in the potential for human exposure. This work described a simple, fast, sensitive, reliable and low‐cost method for the simultaneous measurement of MTBE and its metabolite, tert‐butyl alcohol (TBA) in human serum by headspace solid‐phase microextraction gas chromatography–mass spectrometry. Extraction conditions were optimized and 40 °C, 10 min, 250 rpm and 0.3 g NaCl for a 1 mL sample were the optimal conditions. This method showed good analytical performance in terms of sensitivity with limits of detection in serum (1 mL) of 0.03 µg/L for MTBE and 0.05 µg/L for TBA, accuracy (mean recovery values) from 75.8% to 85.8%, precision (relative standard deviations) <10% and sample stability (biodegradation) <10% after 28 days. A verification experiment proved the reproducibility and stability of this method as well. Finally the method was used to detect 212 specimens, and the internal dose levels for MTBE in human serum were presented in China. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号