共查询到20条相似文献,搜索用时 11 毫秒
1.
A Steinmetz V Clavey N Vu-Dac H Kaffarnik J C Fruchart 《Journal of chromatography. A》1989,487(1):154-160
2.
A system for the isolation of human plasma lipid transfer protein (LTP) has been devised using a combination of conventional and high-performance ion-exchange chromatography. Following initial purification by ammonium sulphate precipitation, ultracentrifugation, hydrophobic interaction and cation-exchange chromatography, appropriate fractions were further purified using the Pharmacia fast protein liquid chromatography system. Using this method of purification, human plasma LTP has been purified more rapidly and with greater recovery than with conventional column chromatography. Whereas two forms of LTP were previously reported from the authors' laboratory [LTP-I, molecular mass (Mr) 69,000 and LTP-II, Mr 55,000], with an improved chromatographic system only one form of LTP (LTP-I) has been isolated. This suggests that LTP-II may have been a fragment of LTP-I, produced during the previously used lengthy purification process. 相似文献
3.
Prolactin and growth hormone are two peptide hormone with a very similar structure. A simple method is described for the simultaneous purification of these two peptides from canine pituitary extract by fast protein liquid chromatography. After extraction at pH 5.0 and 9.6 and anion-exchange chromatography on a MonoQ column, prolactin and growth hormone are then separated by gel filtration chromatography on two Superose columns coupled in series. The different fractions of the purification scheme are checked for the presence of the peptide hormones by sodium dodecyl sulphate gel electrophoresis in the Pharmacia PhastSystem. Each hormone is also characterized by its behaviour in a Western Blotting Detection System. 相似文献
4.
5.
A fast protein liquid chromatographic method is described for the purification of the C1 repressor of bacteriophage P1 and its truncated form C1*. By using one crude extract, both repressor proteins were purified in parallel to homogeneity and were shown to interact specifically with P1 operator DNA in vitro. The method involves an affinity chromatographic step on heparin-Sepharose, followed by a combination of ion-exchange chromatography on Q Sepharose and S Sepharose. The availability of a homogeneous preparation of the phage repressor is a prerequisite for studies on its structure-function relationship. 相似文献
6.
7.
In order to improve the sensitivity of immunometric assays, a chromatographic technique was developed that virtually eliminates components causing non-specific background. Labelled antibodies were applied to a phenyl-Sepharose column in physiological buffer. When labelled anitbodies were purified by this technique, the non-specific background of various time-resolved immunofluorometric assays was reduced 3- to 10-fold and was very close to the instrument background. The assay sensitivity was simultaneously increased by a factor of 2 to 16. This purification method might be used to improve the results of immunometric assays in general. 相似文献
8.
The separation of bovine milk proteins by fast protein liquid chromatography has been investigated by ion-exchange chromatography on Mono Q and Mono S columns and by gel filtration on a column of Superose 12. The four major casein components (alpha s1, alpha s2, beta and kappa) as well as the minor gamma-caseins were generally well separated on the Mono S column with urea-containing buffers at pH 3.8 in as short a time as 7 min, although there was considerable overlap between alpha s1- and alpha s2-casein peaks. Peak area measurements indicated that the four caseins alpha s1, alpha s2, beta and kappa were present in total casein in the approximate proportions of 3.0:0.5:3.4:0.9, in good agreement with other literature values. Whey proteins were not separated on the Mono S column, but were all well resolved by rapid analysis on the Mono Q column at pH values between 6 and 8 in buffers free of urea or 2-mercaptoethanol. Both urea and 2-mercaptoethanol were required for casein analyses on the Mono Q column, but all the casein components were then separable over a broad pH range (5.0-11.0). While urea levels of 4.5-8.0 M and pH values of 7.0 to 8.0 were most generally useful, the resolution of some components was affected by urea concentration or pH, so conditions may have to be modified for specific analysis problems. The caseins were too similar in size to be separated on the Superose 12 column but high-speed gel filtration in as little as 15 min separated all the whey proteins well, molecular weight values obtained being in good agreement with literature values. 相似文献
9.
10.
L C Chaplin 《Journal of chromatography. A》1986,363(2):329-335
Bovine whey proteins and caseins were separated by hydrophobic interaction chromatography with the new Pharmacia fast protein liquid chromatography column, phenyl-Superose. Total casein was separated using a decreasing gradient of 0.8 to 0.05 M sodium phosphate and a constant 3.75 M urea concentration at pH 6.0. The order of elution of caseins was beta less than gamma, alpha s2 less than kappa less than alpha s1, and beta-casein was always eluted first. Whey proteins were separated with a decreasing salt gradient of 1.5 to 0 M ammonium sulphate in 0.05 M sodium phosphate at pH 7.0. The order of elution was beta-lactoglobulin less than bovine serum albumin less than immunoglobulin less than alpha-lactalbumin. The elution order of proteins from the column did not correlate with the calculated average hydrophobicities but the method was considered to be a measure of the "effective" hydrophobicity of proteins and therefore of more use for attempting to relate hydrophobicity to functional properties of proteins. The method shows significant advantages over conventional techniques allowing rapid optimization of elution conditions and reducing run times from 24 h or more to less than 2 h. 相似文献
11.
Summary
125I-aprotinin has been prepared and purified by affinity chromatography in combination with hydrophobic interaction chromatography (HIC). The method allows the preparation of the labelled inhibitor practically carrier-free, in saline solution without organic modifier and the isolated compound retained inhibition activity. Recovery of radioactive material was virtually quantitative, without substantial accumulation of radioactivity on the column. Compared with currently used procedures, the method is more reliable because the labelled polypeptide is collected by following its specific chromatographic signal. 相似文献
12.
Two methods are described by which the enzymes 2-methyleneglutarate mutase and 3-methylitaconate delta-isomerase from Clostridium barkeri have been separated by high-performance liquid chromatography on a much larger scale than reported previously. First, the mutase eluted before the delta-isomerase after incubation with the mild detergent 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulphonate (CHAPS) followed by high-performance anion-exchange chromatography on Mono Q in the presence of the same detergent. Second, an even better separation, although with a lower yield of mutase, was obtained by hydrophobic interaction chromatography on phenyl-Sepharose HiLoad, whereby the enzymes were eluted in the reverse order. Final high-performance anion-exchange chromatography of the latter preparation on Mono Q at pH 8 gave highly purified 2-methyleneglutarate mutase (greater than 95% purity) which had a pink-orange colour (lambda max 280, 375, 470 and 532 nm). The enzyme was active in the absence of coenzyme B12 (adenosylcobalamin) and contained 2.1 mol of this coenzyme per homotetramer (molecular mass, m = 300 kilodalton). 相似文献
13.
14.
Chromatographia - A high-performance liquid chromatography (HPLC) method was developed for the purification of 50mg crude human chorionic gonadotropin (HCG) hormone sample in one chromatographic... 相似文献
15.
A simple procedure is described for the purification of phosphatidylcholine-hydrolyzing phospholipase C(PLC). Lecithin, the substrate for PLC, was ligated hydrophobically to octyl-Sepharose in 2 M (NH4)2SO4. The washed lecithin-conjugated resin was then used to purify PLC from crude preparations by affinity chromatography. PLC binds to the lecithin moiety in the presence of Zn2+ and is eluted with an acidic buffer containing EDTA. PLC activity was recovered in the eluate. Both sodium dodecyl sulphate polyacrylamide gel electrophoresis and pI electrofocusing showed that the eluate contained a single monomeric protein with an apparent molecular mass of 66 kDa and a pI of 5.5. 相似文献
16.
Humanized monoclonal antibodies (mAbs) hold significant promise as biopharmaceuticals. One of the main challenges faced in the purification of mAbs is their separation from bovine serum albumin, which is the main protein present in most mammalian cell culture media. This paper discusses the purification of humanized mAb hIgG1-CD4 from CHO cell culture media by hydrophobic interaction membrane chromatography using a stack of microporous synthetic membranes. The effects of solution conditions on mAb solubility and binding on the membrane were first studied. The separation of a simulated mixture of bovine albumin and the mAb was then carried out to examine the feasibility of mAb purification. Separation experiments carried out under optimized conditions demonstrated that this membrane-based technique could be used for mAb purification from cell culture media. High purity (97%) and recovery (in excess of 97%) were obtained. 相似文献
17.
Rat pancreatic secretory proteins were separated by an automated liquid chromatography system utilizing a Mono S cation-exchange column. Optimal resolution was obtained with a multistep salt and pH gradient (0.01-2 M LiCl, pH 5.3-63). A total of fourteen well-separated peaks, as well as several minor peaks, were detected by UV absorption. The main pancreatic enzymes were resolved (two amylases, two chymotrypsinogens, two trypsinogens, proelastase, lipase, prophospholipase A2, procarboxypeptidase A, procarboxypeptidase B, and ribonuclease). In addition, proteins without enzymic activity, such as lithostathine and pancreatitis-associated protein, were identified. Activation of proenzymes did not occur during the separation. At a flow-rate of 0.5 ml/min, ca. 250 micrograms to 5 mg of protein could be applied with equal resolution. The reproducibility of retention volumes and peak areas was high (less than 1% or 5% variation, respectively). When radiolabeled proteins were separated, a comparable pattern of peaks was obtained. The technique described is, therefore, not only useful for analytical and preparative separation of pancreatic proteins but can additionally serve for quantitative determination of the pancreatic isoenzyme pattern. 相似文献
18.
19.
20.
Homogeneous human placental 17 beta-hydroxysteroid dehydrogenase was obtained by a procedure consisting of two fast protein liquid chromatographic (FPLC) steps using Phenyl-Sepharose hydrophobic interaction and Blue-Sepharose affinity columns. In the first chromatography, the enzyme eluted only when an additional decrease in ionic strength was inserted after the ammonium sulphate concentration had reached zero, thus enhancing the separation. In the affinity chromatography, separation of contaminating proteins occurred at different stages of loading and washing. The specific elution of the enzyme by the co-factor NADP+ is very efficient in obtaining a homogeneous preparation in high yield. The rapidity of FPLC was further increased by a maximum simplification of the intermediate steps, and the whole procedure lasted only two days. This preparation has a yield of more than 50% and a high specific activity, catalysing the formation of 7.9 mumol of estrone from estradiol per minute at pH 9.2 and 23 degrees C. It has an apparent molecular mass of 35,000. This provides an efficient candidate for the purification of other membrane-associated proteins. 相似文献
