首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We present a method for the quantitation of glucagon from rat plasma by protein precipitation and LC/MS. No internal standard was used, as a labeled standard was not available and similar peptides did not show comparable extraction characteristics to glucagon. The LC system included a Keystone C18, 300 A pore size column; a linear gradient was used with a mobile phase consisting of water and acetonitrile, each with 0.2% acetic acid and 0.02% trifluoroacetic acid. Glucagon was detected with the mass spectrometer in positive ion mode monitoring the 4+ charge state at m/z 871.7. The method had an approximated limit of detection of 1 ng/mL. The lower limit of quantitation (LLOQ) was 25 ng/mL (7.2 fmol/mL), which could be reduced with an appropriate internal standard. External calibration was used and calibration curves were found to be linear over the range from 25 to 1000 ng/mL (7.2 to 290 fmol/mL). The method showed a high degree of precision and accuracy both within and between runs at four validation points, including the LLOQ.  相似文献   

2.
Development and validation of simple, rapid, and reliable high-performance liquid chromatography (HPLC)-UV method for quantification of major tyrosine kinase inhibitors, imatinib, dasatinib, and nilotinib, in human plasma is presented. Chromatographic separation of the drugs is achieved on an RP-C(18) column at flow rate of 0.9 mL/min at 35°C; eluate is monitored at 267 nm. Mean intra-day and inter-day precision for all compounds are 2.5 and 13.3%; mean accuracy is 13.9%; extraction recovery ranges within 40.24 and 81.81%. Calibration curves range from 10 to 0.005 μg/mL. Limits of detection are 10 ng/mL for imatinib and nilotinib, 50 ng/mL for dasatinib; limits of quantitation are 50 ng/mL for imatinib and nilotinib, 100 ng/mL for dasatinib. Although this method allows the detection of dasatinib, levels found in patients plasma are close to the limit of detection, then below the limit of quantitation. Quantification with HPLC-mass spectrometry, then, is required for dasatinib to give a correct evaluation. In conclusion, the sensitivity of this new method is sufficient to perform therapeutic monitoring and pharmacokinetic studies of imatinib and nilotinib but not dasatinib in CML patients.  相似文献   

3.
In this study, QuEChERS combined with dispersive liquid‐liquid microextraction is developed for extraction of ten pesticides in complex sample matrices of water and milk. In this regard, effective factors of proposed extraction technique combined with gas chromatography with flame ionization detector were designed, modeled, and optimized using central composite design, multiple linear regression, and Nelder–Mead simplex optimization. Later, univariate calibration model for ten pesticides was developed in concentration range of 0.5–100 ng/mL. Surprisingly, quadratic calibration behavior was observed for some of the pesticides. In this regard, Mandel's test was used for evaluating linearity and types of calibration equation. Finally, four pesticides followed linear calibration curve with sensitivity (0.23–0.66 mL/ng), analytical sensitivity (0.20–0.32), regression coefficient (0.988–0.995), limit of detection (0.39–1.83 ng/mL), and limit of quantitation (1.30–6.10 ng/mL) and six of them followed quadratic calibration curve with sensitivity (0.18–0.93 mL/ng), analytical sensitivity (0.25–0.86), regression coefficient (0.944–0.999), limit of detection (0.59–1.92 ng/mL), and limit of quantitation (1.96–6.40 ng/mL). The calculated limits of detection were below the maximum residue limits according to European Union pesticides database of European Commission. Finally, the proposed analytical method was used for determination of ten pesticides in water and milk samples.  相似文献   

4.
A liquid chromatography/mass spectrometry (LC/MS) analytical procedure, using a single column for sample clean-up, enrichment and separation, has been developed for the determination of the peptide AM336 in monkey cerebrospinal fluid (CSF). CSF samples were injected and analyzed using a polymer-coated mixed-function high-performance liquid chromatography (HPLC) column with gradient elution and application of a timed valve-switching event. The mass spectrometer was operated in the positive electrospray ionization (ESI(+)) mode with single ion recording (SIR) at m/z 920. The method was validated, yielding calibration curves with correlation coefficients greater than 0.9892. Assay precision and accuracy were evaluated by direct injection of AM336-fortified CSF samples at three concentration levels. Analyzed concentrations ranged from 99.93 to 113.1% of their respective theoretical concentrations with coefficients of variation below 9.0%. An evaluation of the signal-to-noise (S/N) ratio for a 200 ng/mL calibration standard, considered to be the lower limit of quantitation (LLOQ), resulted in an estimated limit of detection (LOD) of 31.2 ng/mL. Preliminary data suggest the possibility of using this method to analyze AM336 also in plasma samples, pending the successful outcome of additional investigations.  相似文献   

5.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay was developed and validated to quantify a novel marine-derived depsipeptide, Aplidin, in human plasma. The method was validated to demonstrate the specificity, recovery, limit of quantitation (LOQ), accuracy, and precision of measurements. The calibration range for Aplidin was established using Aplidin standards from 0.05-50 ng/mL in blank human plasma. The multiple reaction monitoring, based on the transition m/z 1110.7 --> 295.3, was specific for Aplidin, and that based on the transition m/z 1112.6 --> 297.3 was specific for didemnin B (the internal standard); no endogenous materials interfered with the analysis of Aplidin and didemnin B from blank human plasma. The assay was linear over the concentration range 0.05-50.0 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9979 to 0.9999. The mean intra- and interday accuracies for all calibration standards (n = 12) ranged from 97 to 106% (相似文献   

6.
Jabor VA  Bonato PS 《Electrophoresis》2001,22(7):1399-1405
A capillary electrophoresis method for the simultaneous quantitation of praziquantel and its main metabolite trans-4-hydroxypraziquantel enantiomers in human plasma was developed and validated using cyclodextrin-modified micellar electrokinetic chromatography. Sample clean-up involved a single-step liquid-liquid extraction of plasma with toluene after the addition of NaCl. The complete enantioselective analysis was obtained in less than 7 min using 2% w/v sulfated beta-cyclodextrin as chiral selector and 20 mmol/L sodium deoxycholate as surfactant, in 20 mmol/L sodium borate buffer, pH 10. A 50 microm x 42 cm uncoated fused-silica capillary was used for the analysis, performed at a voltage of 18 kV and at 20 degrees C. The calibration curves were linear over the 125-625 ng/mL concentration range. The mean recoveries for praziquantel and trans-4-hydroxypraziquantel were up to 96 and 71%, respectively, with good precision. All four enantiomers were quantified at two concentration levels (200 and 600 ng/mL) with precision and accuracy below 15%. The quantitation limit was 50 ng/mL for (-)-(R)- and (+)-(S)-praziquantel and 62.5 ng/mL for (-)-(R)- and (+)-(S)-trans-4-hydroxypraziquantel, using 1 mL of human plasma.  相似文献   

7.
A sensitive and specific liquid chromatography-electrospray ionization mass spectrometry method is developed and validated for the identification and quantitation of azithromycin in human plasma. After the addition of the internal standard and 1.0M sodium hydroxide solution, plasma samples are extracted with a methylene chloride-ethyl acetate mixture (20:80, v/v). The organic layer is evaporated under a stream of nitrogen at 40 degrees C. The residue is reconstituted with 200 microL of the mobile phase. The compounds are separated on a prepacked Shimadzu Shim-pack VP-ODS C18 (5 microm, 150 mm x 2.0 mm) column using a mixture of acetonitrile-water (65:35) (0.5% triethylamine, pH was adjusted to 6.2 with acetic acid) as the mobile phase. Detection is performed on a single quadrupole mass spectrometer by selected ion monitoring mode via electrospray ionization source. The method is fully validated and linear calibration curves are obtained in the concentration ranges from 5 to 2000 ng/mL. The intra- and inter-batch relative standard deviations at four different concentration levels are all < 10%. The limit of detection and quantitation are 2 ng/mL and 5 ng/mL, respectively. The proposed method enables the unambiguous identification and quantitation of azithromycin for pharmacokinetic, bioavailability, or bioequivalence studies.  相似文献   

8.
A high‐performance liquid chromatographic (HPLC) method was developed for the analysis of the stilbene, oxyresveratrol. This method involves the use of a Luna® C18 column with ultraviolet detection at 320 nm. The mobile phase consisted of acetonitrile, water and formic acid (30 : 70 : 0.04 v/v) with a flow rate of 0.6 mL/min. The calibration curves were linear over the range of 0.5–100.0 μg/mL. The mean extraction efficiency was between 98.9 and 109%. The precision of the assay was 0.069–18.4% (RSD%), and within 20% at the limit of quantitation (0.5 μg/mL). The bias of the assay was <15% and within 15% at the limit of quantitation. This assay was successfully applied to pre‐clinical pharmacokinetic samples from rat urine and to nutraceutical product analysis. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
We present a method for the quantitation of motilin from rat plasma by protein precipitation and liquid chromatography/mass spectrometry (LC/MS). Using external calibration, the method was linear over the concentration range 10-1000 ng/mL with an initial sample volume of 150 microL. The LC system included a C(18) column with a 300 A pore size. A linear gradient was used with a mobile phase consisting of water and acetonitrile, each with 0.2% acetic acid and 0.02% trifluoroacetic acid. Motilin was detected with the mass spectrometer in positive ion mode monitoring the 4+ charge state at m/z 675.5. The approximated limit of detection was less than 1 ng/mL and the lower limit of quantitation (LLOQ) was 10 ng/mL. The method showed a high degree of precision and accuracy both within and between runs at five validation points, including the LLOQ.  相似文献   

10.
A simple and rapid method was developed for the quantitation of antalarmin from plasma using high performance liquid chromatography coupled with electrospray ionization mass spectrometry (ESI/MS). Separation of antalarmin from interfering compounds was achieved using reversed phase chromatography on a C-8 micro-column with an isocratic mobile phase comprised of 80% acetonitrile, 20% water, and 5 mM triethylamine. Detection by ESI/MS was accomplished in positive ion mode using single ion monitoring of the protonated molecular ions of antalarmin and its 13C2-isotopimer. The area ratio of the integrated peaks of interest in the extracted ion chromatogram was used for quantitation. The lower limit of detection was 1 picogram (pg) and the quantitation showed a linear response up to 4 nanograms loaded on column. To achieve acceptable accuracy at or around the limit of quantitation of 20 pg, a 1/x weighting was applied to the calibration data. Accuracy and precision variation for intra and inter-day validation were below the acceptable limit (15%) for pharmacokinetic studies.  相似文献   

11.
A method of analysis of piceatannol in biological fluids is necessary to study the kinetics of in vitro and in vivo metabolism and determine its concentration in foodstuffs. A novel and simple high-performance liquid chromatographic method was developed for simultaneous determination of piceatannol and products of its metabolism in rat serum and liver microsomes. Serum, or microsomes (0.1 mL), were precipitated with acetonitrile after addition of the internal standard, 4-methylumbelliferone. Separation was achieved on a phenomenex C(18) column (250 x 4.6 mm i.d., 5 microm) equipped with a phenomenex C(18) (4 x 3.0 mm i.d., 5 microm) guardcolumn with fluorescence excitation at 320 nm and emission at 420 nm. Separation was also possible with UV detection at 310 nm. The fluorescent calibration curves were linear ranging from 0.05 to 100 microg/mL. The mean extraction efficiency was >95%. Precision of the assay was <10% (coefficient of variation), and was within 10% at the limit of quantitation (0.05 ng/mL). Bias of the assay was lower than 7%. The limit of detection was 50 ng/mL for a 0.1 mL sample. The assay was applied successfully to the in vitro kinetic study of metabolism of piceatannol in rat liver microsomes and pharmacokinetics in rats. Three metabolites of piceatannol have been identified. .  相似文献   

12.
A liquid chromatography electrospray ionization tandem mass spectrometry (LC/ESI–MS/MS) method was developed and validated to measure GDC-0084 in human plasma and cerebrospinal fluid (CSF). Reverse-phase chromatography with gradient elution was performed using a C18 column (50 × 2.0 mm, 3 μm). Solid-phase extraction of plasma and CSF was employed to give excellent recovery. MS detection was performed with positive ion screening in multiple reaction monitoring mode. The precursor to the product ions (Q1 → Q3) selected for GDC-0084 and GDC-0084-d6 were 383.2 → 353.2 and 389.2 → 353.2, respectively. A separate calibration curve was established for human plasma and CSF. Both calibration curves, ranging from 0.2 to 200 ng/mL, were linear and had acceptable intra- and inter-day precision and accuracy. The lower limit of quantitation and limit of detection for GDC-0084 in human plasma were 0.2 ng/mL (signal/noise ≥47) and 0.005 ng/mL (signal/noise ≥3.5), respectively, and for GDC-0084 in human CSF were 0.2 ng/mL (signal/noise ≥19.7) and 0.04 ng/mL (signal/noise ≥7.2). This method was successfully applied to analyze serial plasma samples obtained from children with diffuse intrinsic pontine gliomas and other midline gliomas who participated in pharmacokinetic studies as part of a phase I clinical trial of GDC-0084.  相似文献   

13.
Accurate and reproducible HPLC methods were developed and validated for the determination of concentrations of luteolin (LT) and tetra‐acetyl‐luteolin (TALT) in rat plasma. HPLC analyses were performed on an Agilent TC‐C18 column protected by a guard Agilent Zorbax Eclipse Plus. The mobile phase for LT was a binary mixture of acetonitrile–water (40:60, v/v) containing 0.5% phosphoric acid at a flow rate of 1.0 mL/min, and that for TALT was a binary mixture of methanol–water (70 : 30, v/v) containing 0.5% glacial acetic acid at the same flow rate. The UV detection wavelength for both analytes was set at 350 nm. The calibration curve was linear over the range of 40–1800 ng/mL, the lower limit of quantitation was 40 ng/mL and the lower limit of detection was 20 ng/mL for both LT and TALT. The intra‐ and inter‐day precision (RSD) values for all samples were within 7.9%. The concentration–time curves of LT and TALT after oral administration (30 mg/kg) were both fitted to a two‐compartment model. The pharmacokinetic characteristics of TALT were better than that of LT in the maximum plasma concentration (Cmax) and the area under the concentration–time curve (AUC). Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
A simple, rapid, and sensitive high-performance liquid chromatographic method is developed for the determination of ibafloxacin in rabbit plasma. Plasma proteins are precipitated with acetonitrile, and after extraction with methylene chloride followed by desecation, ibafloxacin is determined by reversed-phase chromatography with fluorescence detection exciting at 330 nm and emission at 368 nm. Peaks corresponding to ibafloxacin and the internal standard (salycilic acid) are obtained at 9.8 and 5.2 min, respectively. The method is validated for a limit of quantitation of 10 ng/mL. The intraday relative standard deviation ranges from 4.78-7.15%, and the interday precision ranges from 1.32-4.03%. The method shows linearity for the two calibration curves used (10-100 ng/mL and 100-2000 ng/mL). The procedure described is applied successfully to a pharmacokinetics study of ibafloxacin in rabbits.  相似文献   

15.
A sensitive and rapid liquid chromatography/electrospray ion trap mass spectrometry (LC/MS/MS) method has been developed for the quantitative determination of medroxyprogesterone acetate (MPA) in human plasma. Plasma samples (1.0 mL) were simply extracted with pentane and the extracts were analyzed by HPLC with the detection of the analyte in the selective reaction monitoring (SRM) mode. The determination of MPA was accurate and reproducible, with a limit of quantitation of 0.05 ng/mL in plasma. The standard calibration curve for MPA was linear (r = 0.998) over the concentration range 0.05-6.0 ng/mL in human plasma. Analysis precision over the concentration range of MPA was lower than 18.8% (relative standard deviation, RSD) and accuracy was between 96.2 and 108.7%.  相似文献   

16.
This paper reports a rapid and sensitive method for determination of the anti-inflammatory compound vicenin-2 in L. ericoides Mart. using liquid chromatography-tandem mass spectrometry. Separation of the compound of interest was performed on a VP-ODS(18) (150 x 2 mm, Shimadzu, Japan) column and a pre-column packed with GPV-ODS C(18) (5 x 2 mm, Sigma-Aldrich, USA) with acetonitrile-water (15:85) mobile phase containing 2% acetic acid using isocratic flow at 0.5 mL/min for 2 min. Multiple-reaction monitoring of vicenin-2 was performed using electrospray positive ionization. The linear calibration curves were generated using a concentration range of 5-2500 ng/mL with correlation coefficients >0.99. The values of limit of detection and limit of quantitation were found to be 1 and 5 ng/mL, respectively. The method developed based on LC-ESIMS/MS is advantageous because it permits the rapid and selective detection of vicenin-2. Furthermore, the method can be easily applied to the routine analysis of vicenin-2 in plant extracts using a minimal amount of sample.  相似文献   

17.
An analytical method was developed for the determination of sulfamethoxazole (SMZ) in the presence of trimethoprim (TMP) by normal fluorescence. When both analytes are present a selective derivatization with fluorescamine of SMZ gives an intense fluorescent derivative with no interference from the other compound. The reaction was optimized to obtain the best analytical performance. The detection limit and the lower limit of quantitation of SMZ in the reaction medium was 5.2 ng/mL. The intra-day precision (relative standard deviation) was 1.51% for a 100 ng/mL SMZ standard solution and the inter-day precision over 7 days for a 100 ng/mL solution in the presence of 20 ng/mL TMP solution was 2.5%. The method has been applied to three pharmaceutical preparations containing both compounds, without any separation steps required.  相似文献   

18.
Wogonin and oroxylin A in Scutellariae Radix, schisandrin in Chinensis Fructus, paeoniflorin in Moutan Cortex and emodin in Polygoni Cuspidate Rhizome et Radix are anti‐inflammatory active compounds. A method for simultaneous determination of the five compounds in rat was developed and validated using high‐performance liquid chromatography with tandem mass spectrometry (HPLC–MS/MS). The separation was performed on a Symmetry C18 column (4.6 × 50 mm, 3.5 μm) with acetonitrile and 0.1% formic acid aqueous solution as the mobile phases. The detection was performed using multiple‐reaction monitoring with electrospray ionization source in positive–negative ion mode. The calibration curves showed good linearity (r ≥ 0.9955). The lower limit of quantification (LLOQ) was 5 ng/mL for wogonin and schisandrin, 10 ng/mL for oroxylin A and emodin, and 15 ng/mL for paeoniflorin, respectively. The relative standard deviations of intraday and interday precisions were <11.49 and 14.28%, respectively. The extraction recoveries and matrix effects were acceptable. The analytes were stable under the experiment conditions. The validated method has been successfully applied to pharmacokinetic studies of the five compounds in rats after oral administration of Hu‐gan‐kan‐kang‐yuan capsule. This paper would be a valuable reference for pharmacokinetic studies of Chinese medicine preparations containing the five compounds.  相似文献   

19.
An analytical method was developed for the determination of sulfamethoxazole (SMZ) in the presence of trimethoprim (TMP) by normal fluorescence. When both analytes are present a selective derivatization with fluorescamine of SMZ gives an intense fluorescent derivative with no interference from the other compound. The reaction was optimized to obtain the best analytical performance. The detection limit and the lower limit of quantitation of SMZ in the reaction medium was 5.2 ng/mL. The intra-day precision (relative standard deviation) was 1.51% for a 100 ng/mL SMZ standard solution and the inter-day precision over 7 days for a 100 ng/mL solution in the presence of 20 ng/mL TMP solution was 2.5%. The method has been applied to three pharmaceutical preparations containing both compounds, without any separation steps required. Received: 28 December 1998 / Revised: 28 April 1999 / Accepted: 30 April 1999  相似文献   

20.
A sensitive method has been developed for the direct quantitation of the methyl phosphotriester DNA adduct of thymidyl(3'-5')thymidine (dTp(Me)dT) from enzymatic DNA hydrolysates prepared from cultured cells treated with low levels of N-methyl-N-nitrosourea (MNU) and methyl methane sulfonate (MMS), by rapid and selective liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (LC/APCI-MS/MS). The lower limit of quantitation was 0.1 ng/mL (6.4 adducts per 10(8) nucleotides). Linearity of the calibration curve was greater than 0.999 from 0.1 to 50 ng/mL. Intra-day precision for three levels of quality control samples ranged from 4.27 to 15.62%. Interday precision ranged from 2.46 to 11.95%. Using this method, the levels of dTp(Me)dT in DNA enzymatic hydrolysates obtained from a series of incubations of mouse lymphoma cells with low doses of MNU (50 microM) were quantified.  相似文献   