首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A MS‐based methodology has been developed for analysis of core‐fucosylated versus antennary‐fucosylated glycosites in glycoproteins. This procedure is applied to the glycoprotein alpha‐1‐antitrypsin (A1AT), which contains both core‐ and antennary‐fucosylated glycosites. The workflow involves digestion of intact glycoproteins into glycopeptides, followed by double digestion with sialidase and galactosidase. The resulting glycopeptides with truncated glycans were separated using an off‐line HILIC (hydrophilic interaction liquid chromatography) separation where multiple fractions were collected at various time intervals. The glycopeptides in each fraction were treated with PNGase F and then divided into halves. One half of the sample was applied for peptide identification while the other half was processed for glycan analysis by derivatizing with a meladrazine reagent followed by MS analysis. This procedure provided site‐specific identification of glycosylation sites and the ability to distinguish core fucosylation and antennary fucosylation via a double digestion and a mass profile scan. Both core and antennary fucosylation are shown to be present on various glycosites in A1AT.  相似文献   

2.
Novel 3‐aminophenylboronic acid functionalized poly(glycidyl methacrylate‐co‐ethylene dimethacrylate) microspheres were prepared for the solid‐phase extraction of glycopeptides/glycoproteins. The adsorption efficiency, maximum adsorption capacity, and specific recognition of the microspheres to glycoprotein were investigated. The results indicated excellent adsorption of glycoproteins by the microspheres, which are attributed to the well‐defined boronic acid brushes on the microsphere surfaces. Furthermore, a solid‐phase extraction microcolumn filled with the microspheres was used to efficiently enrich glycopeptides from enzymatic hydrolysates from human serum samples. The mass spectrometry results demonstrated that the method is suitable for the separation and enrichment of glycopeptides/glycoproteins from complex biological samples.  相似文献   

3.
Traveling-wave ion mobility (TWIM) coupled to mass spectrometry (MS) has emerged as a powerful tool for structural and conformational analysis of proteins and peptides, allowing the analysis of isomeric peptides (or proteins) with the same sequence but modified at different residues. This work demonstrates the use of the novel TWIM-MS technique to separate isomeric peptide ions derived from chemical cross-linking experiments, which enables the acquisition of distinct product ion spectra for each isomer, clearly indicating modification on different sites. Experiments were performed with four synthetic peptides, for which variable degrees of mobility separation were achieved. In cases of partially overlapping mobility arrival time distributions (ATDs), extracting the ATDs of fragment ions belonging to each individual isomer allowed their separation into two distinct ATDs. Accumulation over regions from the specific ATDs generates the product ion spectrum of each isomer, or a spectrum highly enriched in their fragments. The population of both modified peptide isomers was correlated with the intrinsic reactivities of different Lys residues from reactions conducted at different pH conditions.  相似文献   

4.
Ion mobility-mass spectrometry   总被引:3,自引:0,他引:3  
This review article compares and contrasts various types of ion mobility-mass spectrometers available today and describes their advantages for application to a wide range of analytes. Ion mobility spectrometry (IMS), when coupled with mass spectrometry, offers value-added data not possible from mass spectra alone. Separation of isomers, isobars, and conformers; reduction of chemical noise; and measurement of ion size are possible with the addition of ion mobility cells to mass spectrometers. In addition, structurally similar ions and ions of the same charge state can be separated into families of ions which appear along a unique mass-mobility correlation line. This review describes the four methods of ion mobility separation currently used with mass spectrometry. They are (1) drift-time ion mobility spectrometry (DTIMS), (2) aspiration ion mobility spectrometry (AIMS), (3) differential-mobility spectrometry (DMS) which is also called field-asymmetric waveform ion mobility spectrometry (FAIMS) and (4) traveling-wave ion mobility spectrometry (TWIMS). DTIMS provides the highest IMS resolving power and is the only IMS method which can directly measure collision cross-sections. AIMS is a low resolution mobility separation method but can monitor ions in a continuous manner. DMS and FAIMS offer continuous-ion monitoring capability as well as orthogonal ion mobility separation in which high-separation selectivity can be achieved. TWIMS is a novel method of IMS with a low resolving power but has good sensitivity and is well intergrated into a commercial mass spectrometer. One hundred and sixty references on ion mobility-mass spectrometry (IMMS) are provided.  相似文献   

5.
Characterization of the glycans of glycoproteins is essential for the development and production of biologics. Numerous methods are available for analyzing the glycans of glycoproteins directly and labeled glycans. Nevertheless, glycopeptides are difficult to resolve because of their exceptional complexity and the microheterogeneity of glycans. These properties represent technical challenges to efforts to insure the accurate characterization of biopharmaceuticals to comply with regulatory requirements. Therefore, we investigated the retention behavior of peptides and glycopeptides in hydrophilic interaction chromatography‐mode HPLC in the presence of ion‐pairing reagents. Anionic ion‐pairing reagents decreased the retention times of glycopeptides and improved resolution in the presence of higher concentrations or hydrophobicities of ion‐pairing reagent. Anionic ion‐pairing reagents increased retention times of larger glycans because of their increased hydrophilicity. In contrast, in the presence of cationic ion‐pairing reagents, the retention times of glycopeptides with greater numbers of sialic acid residues decreased. It is appropriate to add an anionic ion‐pairing reagent to the mobile phase for good separation of glycopeptides. The collision cross‐sectional area values of glycopeptides determined using electrospray ionization‐ion mobility spectrometry‐mass spectrometry correlated with retention times. These findings support the implementation of hydrophilic interaction chromatography‐mode HPLC to improve the characterization of glycosylated biopharmaceuticals.  相似文献   

6.
The analysis of glycosylation from native biological sources is often frustrated by the low abundances of available material. Here, ion mobility combined with electrospray ionization mass spectrometry have been used to extract the spectra of N-glycans released with PNGase F from a serial titration of recombinantly expressed envelope glycoprotein, gp120, from the human immunodeficiency virus (HIV). Analysis was also performed on gp120 expressed in the α-mannosidase inhibitor, and in a matched mammalian cell line deficient in GlcNAc transferase I. Without ion mobility separation, ESI spectra frequently contained no observable ions from the glycans whereas ions from other compounds such as detergents and residual buffer salts were abundant. After ion mobility separation on a Waters T-wave ion mobility mass spectrometer, the N-glycans fell into a unique region of the ion mobility/m/z plot allowing their profiles to be extracted with good signal:noise ratios. This method allowed N-glycan profiles to be extracted from crude incubation mixtures with no clean-up even in the presence of surfactants such as NP40. Furthermore, this technique allowed clear profiles to be obtained from sub-microgram amounts of glycoprotein. Glycan profiles were similar to those generated by MALDI-TOF MS although they were more susceptible to double charging and fragmentation. Structural analysis could be accomplished by MS/MS experiments in either positive or negative ion mode but negative ion mode gave the most informative spectra and provided a reliable approach to the analysis of glycans from small amounts of glycoprotein.  相似文献   

7.
Li J  Li X  Guo Z  Yu L  Zou L  Liang X 《The Analyst》2011,136(19):4075-4082
Desalting peptides before mass spectrometry analysis is important because salts lead to adduct formation, increased chemical noise and ion suppression effect. A high concentration of salt can clog nanoelectrospray ionization (ESI) emitters. The reverse phase C18 material is commonly used to desalt peptides because of its high binding capacity. However, peptides with high hydrophilicity, such as glycopeptides, are not retained well on this material, resulting in the loss of peptide information. To improve the efficiency of glycopeptide desalting, we introduced a hydrophilic interaction chromatography (HILIC)-based material named click maltose. Four glycoproteins, horseradish peroxidase (HRP), human serum immunoglobulin G (IgG), bovine ribonuclease B (RNase B), and α-1 acid glycoprotein (AGP) were chosen as models and their glycopeptides were desalted with click maltose, AQ C18, Empore C18 and ZipTip C18. Click maltose as a HILIC material exhibited better performance than the other three C18 materials for both number of targeted glycopeptides and their corresponding intensities. In addition, accurate glycopeptide profiling was achieved with click maltose desalting regardless of peptide lengths and glycan types.  相似文献   

8.
A capillary electrophoresis (CE) method using acidic buffers and capillaries coated with Polybrene, a cationic polymer has been developed for the separation of glycoproteins and glycopeptides. Electrophoretic conditions have been optimized to provide resolution of individual glycoforms observed for different glycoprotein preparations. These conditions were found to be entirely compatible with the operation of electrospray mass spectrometry (ESMS), which facilitated the assignments of possible carbohydrate compositions of glycopeptides arising from digests of glycoproteins. By using operating conditions enhancing the formation of oxonium fragment ions prior to mass spectral analysis, selective identification of glycopeptides was achieved for complex samples such as those from proteolytic digests or chemical cleavages. Examples of applications are presented for ribonuclease B, ovalbumin, horseradish peroxidase, and a lectin from Erithrina corallodendron using both CE-ESMS and CE with ultraviolet detection (CE-UV).  相似文献   

9.
蛋白质的糖基化是最重要的翻译后修饰之一,与蛋白质结构和功能的关系密切。凝集素亲和色谱是蛋白质糖基化研究中很常用的工具,不同的凝集素可以对不同的单糖或寡糖有特异的富集作用。麦胚凝集素(WGA)由于其特异作用的糖型广泛存在而成为使用最多的凝集素之一。在本研究中,发现将WGA用于糖肽亲和富集会导致部分肽段的降解,从而导致后续的肽段序列分析的失败。本文用4种标准蛋白质对这种现象进行了验证,结果表明肽段的降解可以发生在多个位点,其中较多地发生在酪氨酸、苯丙氨酸及亮氨酸的羧基端。这一结果提示:在糖蛋白质组研究中,如果应用WGA富集糖肽并采用质谱进行鉴定,则采用半酶切或非特异性酶切的检索策略更为合适。  相似文献   

10.
The isomeric structure of high‐mannose N‐glycans can significantly impact biological recognition events. Here, the utility of travelling‐wave ion mobility mass spectrometry for isomer separation of high‐mannose N‐glycans is investigated. Negative ion fragmentation using collision‐induced dissociation gave more informative spectra than positive ion spectra with mass‐different fragment ions characterizing many of the isomers. Isomer separation by ion mobility in both ionization modes was generally limited, with the arrival time distributions (ATD) often showing little sign of isomers. However, isomers could be partially resolved by plotting extracted fragment ATDs of the diagnostic fragment ions from the negative ion spectra, and the fragmentation spectra of the isomers could be extracted by using ions from limited areas of the ATD peak. In some cases, asymmetric ATDs were observed, but no isomers could be detected by fragmentation. In these cases, it was assumed that conformers or anomers were being separated. Collision cross sections of the isomers in positive and negative fragmentation mode were estimated from travelling‐wave ion mobility mass spectrometry data using dextran glycans as calibrant. More complete collision cross section data were achieved in negative ion mode by utilizing the diagnostic fragment ions. Examples of isomer separations are shown for N‐glycans released from the well‐characterized glycoproteins chicken ovalbumin, porcine thyroglobulin and gp120 from the human immunodeficiency virus. In addition to the cross‐sectional data, details of the negative ion collision‐induced dissociation spectra of all resolved isomers are discussed. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
The identification of glycosylation sites in proteins is often possible through a combination of proteolytic digestion, separation, mass spectrometry (MS) and tandem MS (MS/MS). Liquid chromatography (LC) in combination with MS/MS has been a reliable method for detecting glycopeptides in digestion mixtures, and for assigning glycosylation sites and glycopeptide sequences. Direct interfacing of LC with MS relies on electrospray ionization, which produces ions with two, three or four charges for most proteolytic peptides and glycopeptides. MS/MS spectra of such glycopeptide ions often lead to ambiguous interpretation if deconvolution to the singly charged level is not used. In contrast, the matrix-assisted laser desorption/ionization (MALDI) technique usually produces singly charged peptide and glycopeptide ions. These ions require an extended m/z range, as provided by the quadrupole-quadrupole time-of-flight (QqTOF) instrument used in these experiments, but the main advantages of studying singly charged ions are the simplicity and consistency of the MS/MS spectra. A first aim of the present study is to develop methods to recognize and use glycopeptide [M+H]+ ions as precursors for MS/MS, and thus for glycopeptide/glycoprotein identification as part of wider proteomics studies. Secondly, this article aims at demonstrating the usefulness of MALDI-MS/MS spectra of N-glycopeptides. Mixtures of diverse types of proteins, obtained commercially, were prepared and subjected to reduction, alkylation and tryptic digestion. Micro-column reversed-phase separation allowed deposition of several fractions on MALDI plates, followed by MS and MS/MS analysis of all peptides. Glycopeptide fractions were identified after MS by their specific m/z spacing patterns (162, 203, 291 u) between glycoforms, and then analyzed by MS/MS. In most cases, MS/MS spectra of [M+H]+ ions of glycopeptides featured peaks useful for determining sugar composition, peptide sequence, and thus probable glycosylation site. Peptide-related product ions could be used in database search procedures and allowed the identification of the glycoproteins.  相似文献   

12.
13.
We developed an efficient and convenient strategy for protein identification and glycosylation analysis of a small amount of unknown glycoprotein in a biological sample. The procedure involves isolation of proteins by electrophoresis and mass spectrometric peptide/glycopeptide mapping by LC/ion trap mass spectrometer. For the complete glycosylation analysis, proteins were extracted in intact form from the gel, and proteinase-digested glycoproteins were then subjected to LC/multistage tandem MS (MSn) incorporating a full mass scan, in-source collision-induced dissociation (CID), and data-dependent MSn. The glycopeptides were localized in the peptide/glycopeptide map by using oxonium ions such as HexNAc+ and NeuAc+, generated by in-source CID, and neutral loss by CID-MS/MS. We conducted the search analysis for the glycopeptide identification using search parameters containing a possible glycosylation at the Asn residue with N-acetylglucosamine (203 Da). We were able to identify the glycopeptides resulting from predictable digestion with proteinase. The glycopeptides caused by irregular cleavages were not identified by the database search analysis, but their elution positions were localized using oxonium ions produced by in-source CID, and neutral loss by the data-dependent MSn. Then, all glycopeptides could be identified based on the product ion spectra which were sorted from data-dependent CID-MSn spectra acquired around localized positions. Using this strategy, we successfully elucidated site-specific glycosylation of Thy-1, glycosylphosphatidylinositol (GPI)-anchored proteins glycosylated at Asn23, 74, and 98, and at Cys111. High-mannose-type, complex-type, and hybrid-type oligosaccharides were all found to be attached to Asn23, 74 and 98, and four GPI structures could be characterized. Our method is simple, rapid and useful for the characterization of unknown glycoproteins in a complex mixture of proteins.  相似文献   

14.
Chen Y  Cao J  Yan G  Lu H  Yang P 《Talanta》2011,85(1):70-75
A novel two-step protease digestion and glycopeptide capture approach has been developed. It is different from traditional tryptic digestion, glycopeptide enriching and identification approach in glycoproteomics. Here, proteins were first digested by Lys-C into relatively large peptides. Glycopeptides among them were selectively captured by hydrazide resin through oxidized glycans. After thorough washing steps, trypsin was used as a second protease to in situ release non-glycosylated part (named as LT-peptides) from glycopeptides. Subsequently, the remaining part of glycopeptides on resin was de-glycosylated by peptide-N-glycosidase F, and collected as DG-peptides. Finally, both LT- and DG-peptides could be analyzed by mass spectrometer, achieving glycoprotein and glycosite identification. The approach was applied to cell lysate after positive validation by a model glycoprotein: 143 N-glycoproteins identified from DG- and LT-fraction both. In those glycoproteins, 189 DG-peptide-revealed N-glycosites got further confirmation by neighboring LT-peptides, which, in the meantime, made 109 glycoproteins get improved sequence coverage with increase even up to 350% (averagely 79.4%). Through controllable release, separate identification and combined interpretation of non-glycopeptides (newly introduced LT-peptides here) and traditional de-glycopeptides, the approach could not only achieve routine N-glycosite identification, but also provide further proofs of N-glycosites and increase glycoprotein sequence coverage.  相似文献   

15.
In this study, the classical semiempirical relationships between the electrophoretic mobility and the charge-to-mass ratio (me vs. q/Mα) were used to model the migration behaviour of peptides and glycopeptides originated from the digestion of recombinant human erythropoietin (rhEPO), a biologically and therapeutically relevant glycoprotein. The Stoke’s law (α = 1/3), the classical polymer model (α = 1/2) and the Offord’s surface law (α = 2/3) were evaluated to predict migration of peptides and glycopeptides, with and without sialic acids (SiA), in rhEPO digested with trypsin and trypsin–neuraminidase. The Stoke’s law resulted in better correlations for the set of peptides used to evaluate the models, while glycopeptides fitted better with the classical polymer model. Once predicted migration times with both models, it was easy to simulate their separation electropherogram. Results were later validated predicting migration and simulating separation of a different set of rhEPO glycopeptides and also human transferrin (Tf) peptides and glycopeptides. The excellent agreement between the experimental and the simulated electropherograms with rhEPO and Tf digests confirmed the potential applicability of this simple strategy to predict, in general, the peptide–glycopeptide electrophoretic map of any digested glycoprotein.  相似文献   

16.
陈刚  白泉  耿信笃 《色谱》2006,24(5):425-431
通过对硅胶基质进行化学改性键合伴刀豆球蛋白(Con A),制备了对糖蛋白具有特异亲和作用的亲和色谱固定相;该固定相非特异性吸附弱,对于糖蛋白和糖肽的分离效果良好。对亲和色谱的分离条件进行了优化,以标准糖蛋白核糖核酸酶B(RNase B)为模型,对其进行了纯化;用糖苷酶切除糖链,并对切除糖链前后的RNase B用胰蛋白酶酶解;用基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)对亲和色谱分离得到的糖蛋白、糖链及糖肽进行了分析,确定了RNase B的一级结构、糖含量、糖基化位点及糖连接方式。该方法快速准确,适于糖蛋白和糖肽的分离表征。将其应用于血清中糖蛋白及酶解后血清中糖肽的分离富集,取得了很好的效果。  相似文献   

17.
Analysis of small amounts of glycoproteins by high performance liquid chromatography (HPLC) and liquid secondary ion mass spectrometry (LSIMS) together with enzyme digestion has been investigated using fetuin as a model. Preliminary data indicates that 71% of the expected peptides were detected by LSIMS analysis of 200 pmol total digest. HPLC profiles of peptides and glycopeptides were obtained from 2 nmol of digest using a reversed phase (C18) column eluted in a solvent system containing TFA, water and acetonitrile. This has provided glycopeptides for subsequent oligosaccharide analysis. Strategies are reviewed for the chromatographic characterization of oligosaccharides following their release from glycopeptides by chemical and enzymatic procedures.  相似文献   

18.
Mass spectrometric analyses of various N-glycans binding to proteins and peptides are highly desirable for elucidating their biological roles. An approach based on collision-induced dissociation (CID) MS(n) spectra acquired by electrospray ionization linear ion trap time-of-flight mass spectrometry (ESI-LIT-TOFMS) in the positive- and negative-ion modes has been proposed as a direct method of assigning N-glycans without releasing them from N-glycopeptides. In the positive-ion mode of this approach, the MS(2) spectrum of N-glycopeptide was acquired so that a glycoside-bond cleavage occurs in the chitobiose residue (i.e., GlcNAcbeta1-4GlcNAc, GlcNAc: N-acetylglucosamine) attached to asparagine (N), and two charges on the [M+H+Na](2+) precursor ion are shared with both of the resulting fragments. These fragments are sodiated B(n)-type fragment ions of oligosaccharide (N-glycan) and a protonated peptide ion retaining one GlcNAc residue on the asparagine (N) residue. The structure of N-glycan was assigned by comparing MS(3) spectra derived from both the sodiated B(n)-type fragment ions of N-glycopeptide and the PA (2-aminopyridine) N-glycan standard (i.e., MS(n) spectral matching). In a similar manner, the structural assignment of sialylated N-glycan was performed by employing the negative-ion CID MS(n) spectra of deprotonated B(n)-type fragment ions of N-glycopeptide and the PA N-glycan standard. The efficacy of this approach was tested with chicken egg yolk glycopeptides with a neutral and a sialylated N-glycan, and human serum IgG glycopeptides with neutral N-glycan isomers. These results suggest that the approach based on MS(n) spectral matching is useful for the direct and simple structural assignment of neutral and sialylated N-glycans of glycopeptides.  相似文献   

19.
A surface-normal surface-induced dissociation (SID) configuration specifically designed for coupling ion mobility spectrometry (IMS) and orthogonal time-of-flight (TOF) mass spectrometer is described. The instrument configuration and the effects of various operating parameters are critically evaluated using ion trajectory calculations (SIMION) and SID spectra of a series of model peptides. The utility of the instrument configuration for simultaneous acquisition of MS and MS–MS spectra in both data-dependent and non-data-dependent modes are also discussed.  相似文献   

20.
Since the development of electrospray ionization (ESI) for ion mobility spectrometry mass spectrometry (IMMS), IMMS have been extensively applied for characterization of gas-phase bio-molecules. Conventional ion mobility spectrometry (IMS), defined as drift tube IMS (DT-IMS), is typically a stacked ring design that utilizes a low electric field gradient. Field asymmetric ion mobility spectrometry (FAIMS) is a newer version of IMS, however, the geometry of the system is significantly different than DT-IMS and data are collected using a much higher electric field. Here we report construction of a novel ambient pressure dual gate DT-IMS coupled with a FAIMS system and then coupled to a quadrupole ion trap mass spectrometer (QITMS) to form a hybrid three-dimensional separation instrument, DT-IMS-FAIMS-QITMS. The DT-IMS was operated at ~3 Townsend (electric field/number density (E/N) or (Td)) and was coupled in series with a FAIMS, operated at ~80 Td. Ions were mobility-selected by the dual gate DT-IMS into the FAIMS and from the FAIMS the ions were detected by the QITMS for as either MS or MSn. The system was evaluated using cocaine as an analytical standard and tested for the application of separating three isomeric tri-peptides: tyrosine-glycine-tryptophan (YGW), tryptophan-glycine-tyrosine (WGY) and tyrosine-tryptophan-glycine (YWG). All three tri-peptides were separated in the DT-IMS dimension and each had one mobility peak. The samples were partially separated in the FAIMS dimension but two conformation peaks were detected for the YWG sample while YGW and WGY produced only one peak. Ion validation was achieved for all three samples using QITMS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏