首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Mass spectrometry imaging (MSI) is a powerful tool in metabolomics and proteomics for the spatial localization and identification of pharmaceuticals, metabolites, lipids, peptides and proteins in biological tissues. However, sample preparation remains a crucial variable in obtaining the most accurate distributions. Common washing steps used to remove salts, and solvent-based matrix application, allow analyte spreading to occur. Solvent-free matrix applications can reduce this risk, but increase the possibility of ionisation bias due to matrix adhesion to tissue sections. We report here the use of matrix-free MSI using laser desorption ionisation performed on a 12 T Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. We used unprocessed tissue with no post-processing following thaw-mounting on matrix-assisted laser desorption ionisation (MALDI) indium-tin oxide (ITO) target plates. The identification and distribution of a range of phospholipids in mouse brain and kidney sections are presented and compared with previously published MALDI time-of-flight (TOF) MSI distributions.  相似文献   

2.
Matrix-assisted laser desorption/ionisation (MALDI) quadrupole time-of-flight mass spectrometry (Q-TOFMS) has been used to detect and image the distribution of a xenobiotic substance in skin. Porcine epidermal tissue was treated with 'Nizoral', a medicated shampoo containing ketoconazole (+/-)-1-acetyl-4-[p-[[(2R,4S)-2-(2,4-dichlorophenyl)-2-(imidazol-1-ylmethyl)-1,3-dioxolan-4-yl]methoxy]phenyl]piperazine) as active ingredient. Following incubation for 1 h at 37 degrees C all excess formulation was washed from the surface. A cross-section of the drug-treated tissue was then blotted onto a cellulose membrane, precoated in matrix (alpha-cyano-4-hydroxycinnamic acid (CHCA)), by airspray deposition. In separate experiments the tissue surface was treated with Nizoral within a triangular former, and subsequently blotted onto a matrix-coated membrane. Sample membranes were then mounted into the recess of specialised MALDI targets with adhesive tape. All samples were analysed by MALDI-TOFMS using an Applied Biosystem 'Q-star Pulsar i' hybrid Q-TOF mass spectrometer fitted with an orthagonal MALDI ion source and imaging software. Detection of the protonated molecule was readily achievable by this technique. Treatment of the tissue within a template gave rise to images depicting the expected distribution of the drug, demonstrating that this technique is capable of producing spatially useful data. Ion images demonstrating the permeation of the applied compound into the skin were achieved by imaging a cross-sectional imprint of treated tissue. A calibration graph for the determination of ketoconazole was prepared using the sodium adduct of the matrix ion as an internal standard. This enabled construction of a quantitative profile of drug in skin. Conventional haematoxylin and eosin staining and microscopy methods were employed to obtain a histological image of the porcine epidermal tissue. Superimposing the mass spectrometric and histological images appeared to indicate drug permeation into the dermal tissue layer.  相似文献   

3.
A novel method is reported for rapid protein identification by the analysis of tryptic peptides using desorption electrospray ionisation (DESI) coupled with hyphenated ion mobility spectrometry and quadrupole time-of-flight mass spectrometry (IMS/Q-ToF-MS). Confident protein identification is demonstrated for the analysis of tryptically digested bovine serum albumin (BSA), with no sample pre-treatment or clean-up. Electrophoretic ion mobility separation of ions generated by DESI allowed examination of charge-state and mobility distributions for tryptic peptide mixtures. Selective interrogation of singly charged ions allowed isobaric peptide responses to be distinguished, along with a reduction in spectral noise. The mobility-selected singly charged peptide responses were presented as a pseudo-peptide mass fingerprint (p-PMF) for protein database searching. Comparative data are shown for electrospray ionisation (ESI) of the BSA digest, without sample clean-up, from which confident protein identification could not be made. Implications for the robustness of the DESI method, together with potential insights into mechanisms for DESI of proteolytic digests, are discussed.  相似文献   

4.
Tong H  Sze N  Thomson B  Nacson S  Pawliszyn J 《The Analyst》2002,127(9):1207-1210
Solid phase microextraction (SPME) with matrix assisted laser desorption/ionization (MALDI) introduction was coupled to mass spectrometry and ion mobility spectrometry. Nicotine and myoglobin in matrix 2,5-dihydroxybenzonic acid (DHB), enkephalin and substance P in alpha-cyano-4-hydroxy cinnaminic acid were investigated as the target compounds. The tip of an optical fiber was silanized for extraction of the analytes of interest from solution. The optical fiber thus served as the sample extraction surface, the support for the sample plus matrix, and the optical pipe to transfer the laser energy from the laser to the sample. The MALDI worked under atmospheric pressure, and both an ion mobility spectrometer and a quadrupole/time-of-flight mass spectrometer were used for the detection of the SPME/MALDI signal. The spectra obtained demonstrate the feasibility of the SPME with MALDI introduction to mass spectrometry instrumentation.  相似文献   

5.
Atmospheric pressure matrix-assisted laser desorption/ionisation quadrupole ion trap (AP-MALDI/QIT) mass spectrometry has been investigated for the analysis of polyethylene glycol (PEG 1500) and a hyperbranched polymer (polyglycidol) in the presence of alkali-metal salts. Mass spectra of PEG 1500 obtained at atmospheric pressure showed dimetallated matrix/analyte adducts, in addition to the expected alkali-metal/PEG ions, for all matrix/alkali-metal salt combinations. The relative intensities of the desorbed ions were dependent on the matrix, the alkali-metal salt added to aid cationisation and the ion trap interface conditions [capillary temperature, in-source collisionally-induced dissociation (CID)]. These data indicate that the adducts are rapidly stabilised by collisional cooling enabling them to be transferred into the ion trap. Experiments using identical sample preparation conditions were carried out on a vacuum MALDI time-of-flight (ToF) mass spectrometer. In all cases, vacuum MALDI-ToF spectra showed only alkali-metal/PEG ions and no matrix/analyte adducts. The tandem mass spectrometry (MS/MS) capability of the ion trap has been demonstrated for a lithiated polyglycol yielding a rich fragment-ion spectrum. Analysis of the hyperbranched polymer polyglycidol by AP-MALDI/QIT reveals the characteristic ion series for these polymers as also observed under vacuum MALDI-ToF conditions.  相似文献   

6.
7.
Identification of suspects via fingermark analysis is one of the mainstays of forensic science. The success in matching fingermarks, using conventional fingermark scanning and database searching, strongly relies on the enhancement method adopted for fingermark recovery; this in turn depends on the components present in the fingermarks, which will change over time. This work aims to develop a robust methodology for improved analytical detection of the fingermark components. For the first time, matrix‐assisted laser desorption/ionisation mass spectrometry imaging (MALDI‐MSI) has been used to image endogenous lipids from fresh and aged, groomed and ungroomed fingermarks. The methodology was initially developed using oleic acid which was detected along with its degradation products over a 7‐day period, at three different temperatures in a time‐course experiment. The optimised methodology was then transferred to the imaging analysis of real fingermark samples. Fingermark patterns were reconstructed by retrieving the m/z values of oleic acid and its degradation products. This allowed the three aged fingermarks to be distinguished. In order to prove that MALDI‐MSI can be used in a non‐destructive way, a simple washing protocol was adopted which returned a fingermark that could be further investigated with classical forensic approaches. The work reported here proves the potential and the feasibility of MALDI‐MSI for the forensic analysis of fingermarks, thus making it competitive with other MSI techniques such as desorption electrospray ionisation (DESI)‐MS. The feasibility of using MALDI‐MSI in fingermark ageing studies is also demonstrated along with the potential to be integrated into routine fingermark forensic analysis. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
A new method is presented for the identification of oligosaccharides obtained by enzymatic digestion of hyaluronan (HA) with bacterial hyaluronidase (E.C. 4.2.2.1, from Streptomyces hyalurolyticus) using matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOFMS). Mixtures containing HA oligosaccharides of tetrasaccharide (4-mer)-34-mer were analyzed using this method. The carboxyl groups of the glucuronate residues in the prepared HA oligomers, were modified as the acidic form (COOH), sodium salts (COONa), organic ammonium salts, or methylesters before MALDI-TOFMS measurement. Among these samples, the methylester form of glucuronate residues in HA oligosaccharides, prepared by methylation using trimethylsilyl diazomethane, afforded high sensitivity for spectra. This simple modification method for carboxyl group methylation of acidic polysaccharides [Hirano et al., Carbohydr. Res., 340, (2005) 2297-2304] provides samples suitable for MALDI-TOF mass spectrometric analysis throughout a significantly enhanced range of masses.  相似文献   

9.
10.
Matrix‐assisted laser desorption/ionisation mass spectrometry imaging (MALDI‐MSI) has been used to image the distribution of the pesticide nicosulfuron (2‐[[(4,6‐dimethoxypyrimidin‐2‐yl)aminocarbonyl]aminosulfonyl]‐N,N‐dimethyl‐3‐pyridinecarboxamide) in plant tissue using direct tissue imaging following root and foliar uptake. Sunflower plants inoculated with nicosulfuron were horizontally sectioned at varying distances along the stem in order to asses the extent of translocation; uptake via the leaves following foliar application to the leaves and uptake via the roots from a hydroponics system were compared. An improved sample preparation methodology, encasing samples in ice, allowed sections from along the whole of the plant stem from the root bundle to the growing tip to be taken. Images of fragment ions and alkali metal adducts have been generated that show the distribution of the parent compound and a phase 1 metabolite in the plant. Positive and negative controls have been included in the images to confirm ion origin and prevent false‐positive results which could originate from endogenous compounds present within the plant tissue. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
The technique of matrix-assisted laser desorption/ionization mass spectrometry (MALDI) is described and examples are given of its use for the examination of glycoproteins, glycopeptides, glycolipids and oligosaccharides. Abundant [M + H]+ ions are produced by the glycoproteins and glycopeptides, whereas glycolipids and oligosaccharides give mainly [M + Na]+ ions. Resolution on time-of-flight (TOF) instruments is poor but improved resolution can be obtained by use of ion cyclotron resonance or magnetic sector instruments. Although the technique gives mainly [M + Na]+ ions from neutral, underivatised oligosaccharides, with little fragmentation when implemented on TOF systems, the use of a reflectron enables fragment ions produced by post-source decay to be obtained. Acidic sugars give less satisfactory positive ion spectra with TOF analysers. but generally produce abundant negative ions. Extensive fragmentation is observed with these compounds when the spectra are recorded with magnetic sector instruments. Neutral glycolipids produce strong spectra from several matrices but acidic glycolipids show extensive fragmentation as the result of sialic acid loss.  相似文献   

12.
Detection and imaging of the herbicide mesotrione (2-(4-mesyl-2-nitrobenzoyl)cyclohexane-1,3-dione) and the fungicide azoxystrobin (methyl (E)-2-{2-[6-(2-cyanophenoxy)pyrimidin-4-yloxy]phenyl}-3-methoxyacrylate), on the surface of the soya leaf, and the detection and imaging of azoxystrobin inside the stem of the soya plant, have been achieved using matrix-assisted laser desorption/ionisation quadrupole time-of-flight mass spectrometry. In leaf analysis experiments, the two pesticides were deposited onto the surface of individual soya leaves on growing plants. The soya leaves were removed and prepared for direct and indirect (following blotting onto matrix-coated cellulose membranes) imaging analysis at different periods after initial pesticide application. In stem analysis experiments, azoxystrobin was added to the nutrient solution of a soya plant growing in a hydroponics system. The plant was left for 48 h, and then horizontal and vertical stem sections were prepared for direct imaging analysis. The images obtained demonstrate the applicability of MALDI imaging to the detection and imaging of small organic compounds in plant tissue and further extend the analytical repertoire of the versatile MALDI technique.  相似文献   

13.
A refined sample preparation procedure for matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) was developed for the evaluation of the degree of substitution (DS) in partially depolymerised carboxymethyl cellulose (CMC). By adding ammonium sulphate to the sample mixture prior to the analysis, good quality mass spectra could be acquired. The usual time-consuming search for 'sweet-spots' at the crystalline rim of the MALDI target spot was also avoided. This quality improvement made it possible to investigate whether various positions on the target spot generated mass spectra in which the measured DS varied. The accuracy and reproducibility of the sample preparation procedure were tested by applying it on three commercial CMCs. The study shows that the DS values that were calculated from the spectra acquired from the centre region of the MALDI target spot were in better agreement with the DS provided by the supplier than were the values obtained from the large crystals at the target spot rim. This observation could be one reasonable explanation for the higher DS values reported in other publications. By applying our refined MALDI sample preparation procedure DS values that were in good agreement with the values provided by the manufacturer could be obtained. This indicates that MALDI-TOFMS of partially depolymerised CMCs can be used for an estimation of the DS as a complement to the more established methods, e.g. NMR, titrimetry, and chromatographic techniques.  相似文献   

14.
Atmospheric pressure (AP) matrix‐assisted laser desorption/ionization (MALDI) is known to suffer from poor ion transfer efficiencies as compared to conventional vacuum MALDI (vMALDI). To mitigate these issues, a new AP‐MALDI ion source utilizing a coaxial gas flow was developed. Nitrogen, helium, and sulfur hexafluoride were tested for their abilities as ion carriers for a standard peptide and small drug molecules. Nitrogen showed the best ion transport efficiency, with sensitivity gains of up to 1900% and 20% for a peptide standard when the target plate voltage was either continuous or pulsed, respectively. The addition of carrier gas not only entrained the ions efficiently but also deflected background species and declustered analyte–matrix adducts, resulting in higher absolute analyte signal intensities and greater signal‐to‐noise (S/N) ratios. With the increased sensitivity of pneumatically assisted (PA) AP‐MALDI, the limits of detection of angiotensin I were 20 or 3 fmols for continuous or pulsed target plate voltage, respectively. For analyzing low‐mass analytes, it was found that very low gas flow rates (0.3–0.6 l min?1) were preferable owing to increased fragmentation at higher gas flows. The analyte lability, type of gas, and nature of the extraction field between the target plate and mass spectrometer inlet were observed to be the most important factors affecting the performance of the in‐line PA‐AP‐MALDI ion source. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
Matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF-MS) is a sensitive mass spectrometric technique which utilises acidic materials as matrices for laser energy absorption, desorption and ionisation of analytes. These matrix materials produce background signals particularly in the low-mass range and make the detection and identification of small molecules difficult and nearly impossible. To overcome this problem this paper introduces matrix-free material-enhanced laser desorption/ionisation mass spectrometry (mf-MELDI-MS) for the screening and analysis of small molecules such as carbohydrates. For this purpose, 4,4'-azo-dianiline was immobilised on silica gel enabling the absorption of laser energy sufficient for successful desorption and ionisation of low molecular weight compounds. The particle and pore sizes, the solvent system for suspension and the sample preparation procedures have been optimised. The newly synthesised MELDI material delivered excellent spectra with regard to signal-to-noise ratio and detection sensitivity. Finally, wheat straw degradation products and Salix alba L. plant extracts were analysed proving the high performance and excellent behaviour of the introduced material.  相似文献   

16.
17.
We propose and evaluate a new mechanism to account for analyte ion signal enhancement in ultraviolet-laser desorption mass spectrometry of droplets in the presence of corona ions. Our new insights are based on timing control of corona ion production, laser desorption, and peptide ion extraction achieved by a novel pulsed corona apparatus. We demonstrate that droplet charging rather than gas-phase ion-neutral reactions is the major contributor to analyte ion generation from an electrically isolated droplet. Implications of the new mechanism, termed charge assisted laser desorption/ionization (CALDI), are discussed and contrasted with those of the laser desorption atmospheric pressure chemical ionization method (LD-APCI). It is also demonstrated that analyte ion generation in CALDI occurs with external electric fields about one order of magnitude lower than those needed for atmospheric pressure matrix assisted laser desorption/ionization or electrospray ionization of droplets.  相似文献   

18.
The use of an atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) source was employed with an atmospheric pressure ion mobility spectrometer (APIMS) and an orthogonal acceleration reflector time-of-flight mass spectrometer (TOFMS) to analyze dipeptide and biogenic amine mixtures from a liquid glycerol 2,5-dihydroxybenzoic acid (DHB) matrix. Improved sensitivities were obtained by the addition of a localized electrical (corona) discharge in conjunction with the AP-MALDI source. Enhanced sample ionization efficiency created by this combination provided an overall elevation in signal intensity of approximately 1.3 orders in magnitude. Combinations of three dipeptides (Gly-Lys, Ala-Lys, and Val-Lys) and nine biogenic amines (dopamine, serotonin, B-phenylethylamine, tyramine, octopamine, histamine, tryptamine, spermidine, and spermine) were resolved in less than 18 ms. In many cases, reduced mobility constants (K(o)) were determined for these analytes for the first time. Ion mobility drift times, flight times, arbitrary signal intensities, and collision-induced dissociation (CID) fragmentation product signatures are reported for each of the samples.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号