首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Major and trace elements (Na, Mg, Al, Si, P, K, Ca, Ti, Mn, Fe, Rb, Sr, Y, Zr, La, Ce, Pr, Nd, Sm, Gd, Dy, Th and U) in igneous rocks were assayed with fused lithium borate glass beads using X-ray fluorescence spectrometry. Low dilution glass beads, which had a 1:1 sample-to-flux ratio, were prepared for determination of rare earth elements. Complete vitrification of 1:1 mixture required heating twice at 1200 degrees C with agitation. Extra pure reagents containing determinants were used for calibrating standards instead of the rock standard. The calibration curves of the 23 elements showed good linearity. Furthermore, the lower limits of detection corresponding to three times the standard deviation for blank measurements were 26 mass ppm for Na2O, 6.7 for MgO, 4.5 for Al2O3, 4.5 for SiO2, 18 for P2O5, 1.1 for K2O, 4.0 for CaO, 3.9 for TiO2, 1.6 for MnO, 0.8 for Fe2O3, 0.5 for Rb, 0.2 for Sr, 0.4 for Y, 0.5 for Zr, 3.3 for La, 6.5 for Ce, 2.7 for Pr, 2.1 for Nd, 1.7 for Sm, 0.7 for Gd, 2.7 for Dy, 0.5 for Th, and 0.6 for U. Using the present method, we determined the contents of these 23 elements in four rhyolitic and granitic rocks from Japan.  相似文献   

2.
Liquid chromatography was used for the quantification of aflatoxin B1-oxime (AFB1-oxime). The yield of AFB1-oxime in the reaction mixture was 89%, while after purification on silica gel it was 72%. LC analysis of the reaction mixture after silica gel fractionation revealed a retention time of 0.84 min for AFB1-oxime, 8.42 min for AFB1, 1.21 min for unknown 1 and 1.61 min for unknown 2. UV-visible analysis of the reaction mixture after silica gel fractionation showed a lambda(max) of 269 and 361 nm for AFB1-oxime, 263 and 360 nm for AFB1, 273 nm for unknown 1 and 275 nm for unknown 2. Excitation and emission wavelengths were found to be 269 and 368/438 nm for AFB1-oxime, 359/424 nm for AFB1, 270 and 367/450 nm for unknown 1 and 273 and 416/447 nm for unknown 2. The method may find versatile application in monitoring reactions for the preparation of oximes of various analytes for the synthesis of their immunogens.  相似文献   

3.
The preparation of new Certified Reference Materials (CRMs) of antarctic matrices forms the backbone of an ongoing project in the framework of the Italian National Program for Antarctic Research. The first CRM of this kind (MURST-ISS-A1 Antarctic Marine Sediment) is already available. The second phase focuses on the certification of antarctic krill, a small shrimp extremely abundant in the Southern Ocean. The total mass of krill available for this purpose is approximately 44 kg and results from the combination of three different catches (Ross Sea, Marguerite Bay and Livingston Island, respectively). The quantification of the following elements in the raw mass appears to be affordable by current analytical techniques, values being in the range of (in μg/g) 0.11–0.30 for As, 0.03–0.12 for Cd, 0.06–0.23 for Cr, 6.1–21 for Cu, 5.7–7.6 for Fe, 0.005–0.008 for Hg, 0.7–1.2 for Mn, 0.013– 0.077 for Ni, 0.04–0.57 for Pb and 12–16 for Zn. On the other hand, the average values ascertained in freeze-dried krill are as a rule one order of magnitude higher, i.e., (in μg/g), 3.2 for As, 0.6 for Cd, 1.8 for Cr, 75 for Cu, 61 for Fe, 0.025 for Hg, 4.6 for Mn, 0.7 for Ni, 2.1 for Pb and 81 for Zn. Information on the pretreatment of krill and details on the planned certification campaign are also given. Received: 10 June 1997 / Revised: 24 September 1997 / Accepted: 28 September 1997  相似文献   

4.
More than 200 samples of marine products have been collected and analyzed for plutonium and almost 100 samples for americium around Hitachi, Tokai and Oarai in the pacific coast of Ibaraki prefecture. The data have shown that the concentration factor (CF) values for plutonium were 330 for bivalve, 770 for abalone (muscle) and 610 for brown algae. For americium, the CF was calculated as 2400 for bivalve, 1000 for abalone (muscle) and 420 for brown algae.  相似文献   

5.
A high-performance liquid chromatographic method is described for the simultaneous determination of methylprednisolone (MP) and methylprednisolone hemisuccinate (MPHS), or hydrocortisone (HC) and hydrocortisone hemisuccinate (HCHS) in human serum. Reversed-phase liquid chromatography was performed on a microparticulate C18 column (Spherisorb, 5 micron) using a mobile phase of 2% glacial acetic acid, 30--35% acetonitrile, 70--65% water with ultraviolet detection (254 nm). The method uses 17 alpha-hydroxyprogesterone as the internal standard for the determination of methylprednisolone and its hemisuccinate ester, or 11-deoxy-17-hydroxycorticosterone as the internal standard for the determination of hydrocortisone and its hemisuccinate ester. The sensitivity is 0.03 microgram/ml for HC, 0.07 microgram/ml for MP, 0.04 microgram/ml for MPHS, and 0.10 microgram/ml for HCHS, with a detection limit of 0.02 microgram/ml for all four steroids. Calibration curves are linear up to 3 micrograms/ml for MP or MPHS (as equivalent MP) and up to 4 micrograms/ml for HC and 7 micrograms/ml (as equivalent HC) for HCHS. The pooled relative standard deviation for replicate for each steroid is less than 7%. Plasma concentration--time curves are reported for MP and MPHS or HC and HCHS of two human subjects following intramuscular administration of 125 mg of methylprednisolone sodium succinate for injection, U.S.P., or 250 mg of hydrocortisone sodium succinate for injection, U.S.P.  相似文献   

6.
Chen SH  Chen YH 《Electrophoresis》1999,20(15-16):3259-3268
This review briefly discusses the use of capillary electrophoretic (CE) methods for the investigations of different aspects of pharmacokinetics. In most investigations, CE was the method of choice because of its unique features, including high resolving power for chiral or metabolite separation, small sample volume for pediatric pharmacokinetics or for cell-based investigations, in situ microdialysis sampling for rapid eliminations, low UV wavelength detection for nonderivatized analytes, fast and simplified sample processing for existing methods that require tedious sample preparation, or as a second method for verifications. Moreover, instrumental aspects of CE-based assays for pharmacokinetic studies, such as different modes of CE methods for analyzing biological samples, sample stacking for increasing detection sensitivity, and coupling techniques with microdialysis and mass spectrometry, are also discussed in this review. Furthermore, the advantages and limitations of CE methods as well as the future outlook for pharmacokinetic studies are summarized.  相似文献   

7.
A liquid chromatographic (LC) method for the determination of fumonisins B1 (FB1) and B2 (FB2) in corn and corn flakes was collaboratively studied by 23 laboratories, which analyzed 5 blind duplicate pairs of each matrix to establish the accuracy, repeatability, and reproducibility characteristics of the method. Fumonisin levels in the corn ranged from <0.05 (blank) to 1.41 microg/g for FB1 and from <0.05 to 0.56 microg/g for FB2, whereas in the corn flakes they ranged from <0.05 to 1.05 microg/g for FB1 and from <0.05 to 0.46 microg/g for FB2. The method involved double extraction with acetonitrile-methanol-water (25 + 25 + 50), cleanup through an immunoaffinity column, and LC determination of the fumonisins after derivatization with o-phthaldialdehyde. Relative standard deviations for the within-laboratory repeatability (RSDr) of the corn analyses ranged from 19 to 24% for FB1 and from 19 to 27% for FB2; for the corn flakes analyses, RSDr ranged from 9 to 21 % for FB1 and from 8 to 22% for FB2. Relative standard deviations for the between-laboratories reproducibility (RSDR) of the corn analyses ranged from 22 to 28% for FB1 and from 22 to 30% for the FB2; for corn flakes analyses, RSDR ranged from 27 to 32% for FB1 and from 26 to 35% for FB2. Mean recoveries of FB1 and FB2 from corn spiked with FB1 at 0.80 microg/g and with FB2 at 0.40 microg/g were 76 and 72%, respectively; for corn flakes spiked at the same levels recoveries were 110 and 97% for FB1 and FB2, respectively. HORRAT ratios for the analyses of corn ranged from 1.44 to 1.53 for FB1 and from 0.96 to 1.48 for FB2, whereas for corn flakes they ranged from 1.60 to 1.82 for FB1 and from 1.39 to 1.68 for FB2.  相似文献   

8.
A new scheme for the quantitative determination of traces of fluoroquinolones (FQs), tetracyclines (TCs) and sulfonamides (SAs) in sewage sludge was developed. The compounds were simultaneously extracted from sewage sludge by pressurized liquid extraction (PLE). A novel and effective method for PLE was developed. Solid-phase extraction was used for cleaning up the extracts. Identification and quantification of the compounds was done using high-performance liquid chromatography with electrospray ionization mass spectrometry in selected reaction monitoring mode. The best recovery of FQs and TCs was obtained by using hydrophilic–lipophilic balance cartridges, recoveries ranged 59% for norfloxacin to 82% for ofloxacin and 95% for doxycycline; for SAs strong cation-exchange cartridges were more efficient, recoveries were 96% for sulfamethoxazole and 43% for sulfadimethoxine. Limit of quantification ranged from 0.1 ng/g for SAs to 160 ng/g for tetracycline. Method precision for TCs was 5.06% and 1.12%, and for SAs 0.43% and 2.01%. FQs precision ranged from 0.77% to 1.89%.  相似文献   

9.
A first post-column chemical derivatization method for the liquid chromatographic determination of phenothiazines is presented. Peroxyacetic acid is introduced as a derivatizing agent for phenothiazines, yielding the colored radical cations or fluorescent sulfoxides, depending on reaction conditions. Both reaction products were successfully employed for the detection of the phenothiazines after their liquid chromatographic separation. The fluorescence spectroscopic detection of the sulfoxides proved to be the more robust and sensitive method. Limits of detection ranged from 4 nM for triflupromazine and trimeprazine to 300 nM for phenothiazine for the fluorescence spectroscopic detection of the sulfoxide and from 0.3 μM for phenothiazine and triflupromazine to 2 μM for trifluperazine for the UV–Vis spectroscopic detection of the radical cation. The calibration functions for the fluorimetric sulfoxide determination ranged from two to more than three decades, starting at the limit of quantification.  相似文献   

10.
The effects of 150 kilogray (kGy) of γ irradiation on cell-wall constituents of cottonwood (CW), lentils straw (LS), apple pruning products (AP) and olive cake (OC) were investigated. Samples were irradiated by γ irradiation at a dose level of 150 kGy under identical conditions of temperature and humidity and analyzed for crude fibre (CF), neutral-detergent fibre (NDF), acid detergent fibre (ADF) and acid-detergent lignin (ADL). The results indicate that γ irradiation decreased CF contents by about 29% for CW, LS and AP and by 17% for OC. NDF values were also decreased by about 4% for CW and OC, and by about 12% for LS and AP. γ Irradiation treatment also decreased ADF values only for CW by 8%. ADL contents decreased by 8% for CW and 5% for OC with no effects for LS and AP. The percentage of cellulose (CL): CF ratio increased by 30, 34, 38 and 20% for CW, LS, AP and OC, respectively. Also, the percentage of hemicellulose (HCL): CF increased by 57% for CW and 16% for OC and decreased by 7% for LS and AP. The percentage of HCL: ADL increased by 22% for CW but decreased by 33% for LS and AP with no changes for OC. There were no changes in CL: ADL ratio for all residues.  相似文献   

11.
This paper examines the benefits of Michaelis-Menten model reduction techniques in stochastic tau-leaping simulations. Results show that although the conditions for the validity of the reductions for tau-leaping remain the same as those for the stochastic simulation algorithm (SSA), the reductions result in a substantial speed-up for tau-leaping under a different range of conditions than they do for SSA. The reason of this discrepancy is that the time steps for SSA and for tau-leaping are determined by different properties of system dynamics.  相似文献   

12.
In this work, an isotope dilution method for determination of selected acidic herbicides by high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS) was developed for surface water samples. Average percent recoveries of native analytes were observed to be between 70.8 and 93.5% and average recoveries of labeled quantification standards [(13)C(6)]2,4-D and [(13)C(6)]2,4,5-T were 85.5 and 101%, respectively. Using this method, detection limits of 0.05 ng/L for dicamba, MCPA, MCPP, and triclopyr, and 0.5 ng/L for 2,4-D were routinely achieved. The method was applied to measuring the concentration of these analytes in surface water samples collected from five sampling locations in the Lower Fraser Valley region of British Columbia, Canada. All of the herbicides monitored were detected at varying levels in the surface water samples collected. The highest concentrations detected for each analyte were 345 ng/L for 2,4-D, 317 ng/L for MCPA, 271 ng/L for MCPP, 15.7 ng/L for dicamba, and 2.18 ng/L for triclopyr. Average detection frequencies of the herbicides were 95% for MCPA, 80% for MCPP, 70% for dicamba, 65% for 2,4-D, and 46% for triclopyr. Seasonal variations of herbicide levels are also discussed.  相似文献   

13.
We report an experimental evaluation of the "input-output surface" for a biochemical AND gate. The obtained data are modeled within the rate-equation approach, with the aim to map out the gate function and cast it in the language of logic variables appropriate for analysis of Boolean logic for scalability. In order to minimize "analog" noise, we consider a theoretical approach for determining an optimal set for the process parameters to minimize "analog" noise amplification for gate concatenation. We establish that under optimized conditions, presently studied biochemical gates can be concatenated for up to order 10 processing steps. Beyond that, new paradigms for avoiding noise buildup will have to be developed. We offer a general discussion of the ideas and possible future challenges for both experimental and theoretical research for advancing scalable biochemical computing.  相似文献   

14.
建立了加速溶剂萃取(ASE)-气相色谱-串联质谱(GC-MS/MS)法用于测定茶叶中10种吡唑和吡咯类农药残留。ASE萃取压力为1.03×107 Pa,萃取温度为100 ℃,萃取时间为5 min,萃取溶剂为乙酸乙酯-正己烷(1:1, v/v)。萃取循环1次,萃取液浓缩后用Envi-Carb/PSA固相萃取小柱净化,乙酸乙酯-正己烷(1:1, v/v)洗脱。洗脱液浓缩后,用正己烷定容,供GC-MS/MS测定,外标法定量。方法的准确度和精密度均符合残留分析要求。方法的定量限(LOQ)分别为唑螨酯0.003 mg/kg、氟虫腈硫化物0.001 mg/kg、氟虫腈0.002 mg/kg、氟虫腈砜化物0.005 mg/kg、溴虫腈0.002 mg/kg、氟硅唑0.006 mg/kg、野燕枯0.001 mg/kg、吡草醚0.001 mg/kg、吡螨胺0.0003 mg/kg、唑虫酰胺0.005 mg/kg。方法的灵敏度能满足各国有关农药的残留限量要求。  相似文献   

15.
A method for simultaneous ICP-MS determination of 13 elements in three types of honey from Poland is described. The method was validated, and the uncertainty budget was set up. The results obtained for the relative expanded uncertainties U rel (k = 2) were 15.1% for Al, 18.6% for B, 18.8% for Ba, 7.9% for Ca, 24.4% for Cd, 7.24% for Cu, 7.9% for K, 4.8% for Mg, 8.3% for Mn, 12.7% for Na, 14.9% for Ni, 12.5% for Pb and 13.4% for Zn. Traceability of the measurement results was established based on the use of the corn flour CRM INCT-CF-3 and the apple leaves CRM SRM 1515 and by analyzing spiked samples. Recovery rates between 94% (Zn) and 107% (Na) were found. The detection limits of all elements studied showed the suitability of the procedure for routine analyses. Summarizing it can be concluded that the described analytical procedures to measure the mass fractions of 13 elements in honey samples with established traceability and evaluated uncertainty allow to obtain reliable and internationally comparable results.  相似文献   

16.
The steady-state response of a three-level system in the presence of a strong laser field is described with the density operator formalism, in order to derive an analytical expression for the intensity of resonance Raman scattering. The Liouville equation for the density operator is written in quantum form for both the molecular system and the radiation field, making use of the dipole and rotating-wave approximations for the matter-radiation interaction, and of the Markov approximation for the molecular decays. The equation is solved exactly for the laser field, and in perturbative way for the generated field. The results account for power broadening of the generated line. Rabi intensity-dip of the generated signal, and for the excitation profiles in the Franck-Condom approximation.  相似文献   

17.
Measuring techniques can be developed and adapted for the characterization of bioreactors, for on-line process analysis and for the determination of biological parameters of cells during fermentation. Mathematical models can be formulated for bioreactors and cell regulation and a combined model for these can be reduced for use in process control. Microprocessors and minicomputers give further scope for data acquisition, model implementation and process control.  相似文献   

18.
A theoretical exposition has been given for the output signal of a.c. voltammetry, that accounts for the presence of six harmonics. It turned out that for fast redox systems and a linear diffusion pattern a simple hyperbolic function could be obtained for the fundamental harmonic valid for high values of the superimposed a.c. voltage. This function can be developed to a series, which resembles for intermediate values of the amplitude the one already given by Smith; for small values of the amplitude the generally accepted expression for a.c. voltammetry is obtained.  相似文献   

19.
The limit of detection (LOD) is based strictly on an accepted probability for a false positive decision (type 1 error). For the needed standard deviation of the blank, a basic value for the calculation, three experimental different methods are described, which should be applicable in every case. Table values for simple but exact calculation, not only for single, but also for mean values, and with probabilities for the type 1 error of 1% and 5% are presented. Demands for an acceptable uncertainty of the LOD and for the validation of the result are specified.  相似文献   

20.
高效液相色谱法测定藻类中的类胡萝卜素和叶绿素   总被引:16,自引:0,他引:16  
袁建平  张义明  史贤明  龚贤弟  陈峰 《色谱》1997,15(2):133-135
提出了用高效液相色谱法测定藻类中类胡萝卜素和叶绿素的方法。采用丙国等有机溶剂提取藻类中的类胡萝卜素和叶绿素,然后在反相C18柱上进行分离。流动相选用二氯甲烷/乙腈/甲醇/水(22.5:9.5:67.5:0.5),流速为1.0mL/min。用光度检测器检测报长为450um。叶黄素、α-胡萝卜素、β-胡萝卜素、叶绿素a和叶绿素b的平均回收串分别为99.1%,98.5%,99.4%,100.6%和99.9%,相对标准偏差分别为2.4%,5.6%,6.0%,4.1%和4.0%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号