首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
磁共振扩散张量成像可以定量无创研究人体内水分子在三维空间中的各向异性扩散规律,进而获取重要的病理及生理信息.为了得到水分子各向异性扩散信息,需要按照一定的方案依次施加不同方向的扩散敏感梯度磁场,测量水分子在这些方向上的扩散系数用以估算扩散张量.扩散张量成像测量结果的准确程度受梯度磁场方向分布方案的影响,本文对扩散敏感梯度磁场方向分布方案进行综述,包括完全随机方案、启发式方案、规则多面体式方案和数值优化方案等,分析这些方案的优势与局限性,并提出需进一步研究的问题.  相似文献   

2.
Minimal gradient encoding for robust estimation of diffusion anisotropy   总被引:4,自引:0,他引:4  
This study has investigated the relationship between the noise sensitivity of measurement by magnetic resonance imaging (MRI) of the diffusion tensor (D) of water and the number N of diffusion-weighting (DW) gradient directions, using computer simulations of strongly anisotropic fibers with variable orientation. The DW directions uniformly sampled the diffusion ellipsoid surface. It is shown that the variation of the signal-to-noise ratio (SNR) of three ideally rotationally invariant scalars of D due to variable fiber orientation provides an objective quantitative measure for the diffusion ellipsoid sampling efficiency, which is independent of the SNR value of the baseline signal obtained without DW; the SNR variation decreased asymptotically with increasing N. The minimum number N(0) of DW directions, which minimized the SNR variation of the three scalars of D was determined, thereby achieving the most efficient ellipsoid sampling. The resulting time efficient diffusion tensor imaging (DTI) protocols provide robust estimation of diffusion anisotropy in the presence of noise and can improve the repeatability/reliability of DTI experiments when there is high variability in the orientation of similar anisotropic structures, as for example, in studies which require repeated measurement of one individual, intersubject comparisons or multicenter studies.  相似文献   

3.
The choice of the number (N) and orientation of diffusion sampling gradients required to measure accurately the water diffusion tensor remains contentious. Monte Carlo studies have suggested that between 20 and 30 uniformly distributed sampling orientations are required to provide robust estimates of water diffusions parameters. These simulations have not, however, taken into account what effect random subject motion, specifically rotation, might have on optimised gradient schemes, a problem which is especially relevant to clinical diffusion tensor MRI (DT-MRI). Here this question is investigated using Monte Carlo simulations of icosahedral sampling schemes and in vivo data. These polyhedra-based schemes, which have the advantage that large N can be created from optimised subsets of smaller N, appear to be ideal for the study of restless subjects since if scanning needs to be prematurely terminated it should be possible to identify a subset of images that have been acquired with a near optimised sampling scheme. The simulations and in vivo data show that as N increases, the rotational variance of fractional anisotropy (FA) estimates becomes progressively less dependent on the magnitude of subject rotation (), while higher FA values are progressively underestimated as increases. These data indicate that for large subject rotations the B-matrix should be recalculated to provide accurate diffusion anisotropy information.  相似文献   

4.
The standard method of diffusion tensor imaging (DTI) involves one diffusion-sensitizing gradient direction per acquired signal. This paper describes an alternative method in which the entire direction set required for calculating the diffusion tensor is captured in a few scans. In this method, a series of radiofrequency (RF) pulses are applied, resulting in a train of spin echoes. A pattern of applied magnetic field gradients between the RF pulses generates a different diffusion weighting in both magnitude and direction for each echo, resulting in a dataset sufficient to determine the tensor. This significantly reduces the time required for a full DTI scan and potentially allows a tradeoff of this time for image quality. In the present work, this method is demonstrated in an anisotropic diffusion phantom (asparagus).  相似文献   

5.
Optimal interpretation of magnetic resonance image content often requires an estimate of the underlying image noise, which is typically realized as a spatially invariant estimate of the noise distribution. This is not an ideal practice in diffusion tensor imaging because the noise distribution is usually spatially varying due to the use of fast imaging and noise suppression techniques. A new estimation approach for spatially varying noise fields (NFs) is proposed in this article. The approach is based on a noise invariance property in scenarios in which more than one image, each with potentially different signal levels, is acquired on each slice, as in diffusion-weighted MRI. This technique leads to improved NF estimates in simulations, phantom experiments and in vivo studies when compared to traditional NF estimators that use regional variability or background intensity histograms. The proposed method reduces the NF estimation error by a factor of 100 in simulations, shows a strong linear correlation (R2=0.99) between theoretical and estimated noise changes in phantoms and demonstrates consistent (<5% variability) NF estimates in vivo. The advantages of spatially varying NF estimation are demonstrated for power analysis, outlier detection and tensor estimation.  相似文献   

6.
We provide scientific background information and personal accounts relating to our publication of “Microstructural and Physiological Features of Tissues Elucidated by Quantitative-Diffusion-Tensor MRI” in the Journal of Magnetic Resonance B. This paper provided a framework for measuring and mapping intrinsic features of diffusion anisotropy obtained from diffusion tensor MRI (DTI) data.  相似文献   

7.
We extend the diffusion tensor (DT) signal model for multiple-coil acquisition systems. Considering the sum-of-squares reconstruction method, we compute the Cramér–Rao bound (CRB) assuming the widely accepted noncentral chi distribution. Within this framework, we assess the effect of noise in DT estimation and other measures derived from it, as a function of the number of acquisition coils, as well as other system parameters. We show the applications of CRB in many actual problems related to DT estimation: we compare different gradient field setup schemes proposed in the literature and show how the CRB can be used to choose a convenient one; we show that for fiber-type anisotropy tensors the ellipsoidal area ratio (EAR) can be estimated with less error than other scalar factors such as the fractional anisotropy (FA) or the relative anisotropy (RA), and that for this type of anisotropy tensors, increasing the number of coils is equivalent to increasing the signal-to-noise ratio, i.e., the information of the different coils can be regarded as independent. Also, we present results showing the CRB of several parameters for actual DT-MRI data. We conclude that the CRB is a valuable tool to optimal experiment design in DT-related studies.  相似文献   

8.
Diffusion tensor imaging (DTI) and tractography are noninvasive MRI methods, providing an insight on microscopic structural information of anisotropic tissues in vivo. The success of this technique stems on a watchful choice of imaging parameters and post-acquisition reconstruction. In the present work, we have focused on the problem of residual linear image misalignment in the DTI data and its effects on the parameters of the diffusion tensor and fiber tracking in human brain. We demonstrate substantial sensitivity of the reconstructed diffusion tensor and fiber tractography on increasing amplitude of artificially induced random image misalignment in the DTI. We show that already a submillimeter image misalignment in the DTI is an important source of error, which may potentially mask pathological presentations of the diseases and may partially explain variations in the results obtained from the DTI. Finally, we evaluated four implementations of image registrations and demonstrate their variable performance. This further supports the fact that a robust image registration must be performed to ensure reliable and reproducible diffusion tensor mapping and reconstruction of white matter (WM) fibers.  相似文献   

9.
磁共振扩散张量成像(DTI)是在扩散加权成像(DWI)基础上发展起来的一种新型技术,可以无创伤显示脑白质纤维,诊断脑白质病变. 但是由于各种原因,DTI一般只在超导高场磁共振成像(MRI)仪器上进行,这就限制了这一重要诊断手段临床应用的广泛性. 本文在低场磁共振成像系统上应用线扫描实现了扩散张量成像,并测量了健康志愿者大脑内主要解剖结构的表观扩散系数(ADC)和各项异性分数(FA),得到的数据与高场仪器上的相关数据比较是吻合的. 因此临床上使用在低场强上得到的DTI图像评价脑白质是可行的,而且通常在临床上这也是足够的.  相似文献   

10.
MRI diffusion tensor reconstruction with PROPELLER data acquisition   总被引:10,自引:0,他引:10  
MRI diffusion imaging is effective in measuring the diffusion tensor in brain, cardiac, liver, and spinal tissue. Diffusion tensor tomography MRI (DTT MRI) method is based on reconstructing the diffusion tensor field from measurements of projections of the tensor field. Projections are obtained by appropriate application of rotated diffusion gradients. In the present paper, the potential of a novel data acquisition scheme, PROPELLER (Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction), is examined in combination with DTT MRI for its capability and sufficiency for diffusion imaging. An iterative reconstruction algorithm is used to reconstruct the diffusion tensor field from rotated diffusion weighted blades by appropriate rotated diffusion gradients. DTT MRI with PROPELLER data acquisition shows significant potential to reduce the number of weighted measurements, avoid ambiguity in reconstructing diffusion tensor parameters, increase signal-to-noise ratio, and decrease the influence of signal distortion.  相似文献   

11.
The structures of two different bovine muscles, the Semitendinosus (ST) and the Triceps brachii (TB), were studied using quantitative maps obtained by diffusion tensor imaging at 4.7 T. The estimated features were: mean diffusivity, intra- and inter-voxel anisotropy and fiber tract orientation angles. Significant differences in anisotropy (fractional anisotropy and lattice index), spatial variations of anisotropy and fiber tract orientation were detected between ST and TB, and are discussed. Accumulation of free water, which diffuses more freely and isotropically than in the rest of the muscle, was detected and localized in ST. These results underline the usefulness of diffusion tensor measurements to characterize muscle structure and help understand the mechanisms of post mortem water exudation.  相似文献   

12.
Geometric distortions of echo-planar images produced by the strong eddy currents present in the diffusion tensor imaging experiment are a major confound to the accurate quantification of diffusion coefficients, and measures of diffusion anisotropy based upon them. Here we investigate how the method of iterative cross-correlation (ICC) of baseline and diffusion-weighted images (DWIs) originally proposed by Haselgrove and Moore (Magn. Reson. Med. 36:960-964; 1996) can be extended to correct high b-value DWIs, without the need for extrapolation of distortion parameters determined from low b-value images. Monte Carlo simulations of synthetic brain images show that the maximum value of the trace of the b-matrix, Tr(b), at which distorted DWIs can be accurately corrected by direct comparison with the undistorted baseline image is approximately 300 s mm(-2). Removal of the cerebrospinal fluid signal greatly extends this value of Tr(b) (up to approximately 2000 s mm(-2)), thereby allowing direct comparison of baseline and distorted images. The use of ICC distortion parameters determined from separate calibrations of water phantom images is also investigated, and found to be effective in correcting geometric distortions observed in the DWIs collected as part of a human volunteer diffusion tensor imaging study. This work suggests that distorted DWIs acquired at high values of b may be corrected using the ICC algorithm without collecting additional low b-value images, thus allowing simplified methods of measuring the apparent diffusion tensor D, based on collecting a small number of DWIs, to be implemented in quantitative patient examinations.  相似文献   

13.
PurposeTo quantify and retrospectively correct for systematic differences in diffusion tensor imaging (DTI) measurements due to differences in coil combination mode.BackgroundMulti-channel coils are now standard among MRI systems. There are several options for combining signal from multiple coils during image reconstruction, including sum-of-squares (SOS) and adaptive combine (AC). This contribution examines the bias between SOS- and AC-derived measures of tissue microstructure and a strategy for limiting that bias.MethodsFive healthy subjects were scanned under an institutional review board-approved protocol. Each set of raw image data was reconstructed twice—once with SOS and once with AC. The diffusion tensor was calculated from SOS- and AC-derived data by two algorithms—standard log-linear least squares and an approach that accounts for the impact of coil combination on signal statistics. Systematic differences between SOS and AC in terms of tissue microstructure (axial diffusivity, radial diffusivity, mean diffusivity and fractional anisotropy) were evaluated on a voxel-by-voxel basis.ResultsSOS-based tissue microstructure values are systematically lower than AC-based measures throughout the brain in each subject when using the standard tensor calculation method. The difference between SOS and AC can be virtually eliminated by taking into account the signal statistics associated with coil combination.ConclusionsThe impact of coil combination mode on diffusion tensor-based measures of tissue microstructure is statistically significant but can be corrected retrospectively. The ability to do so is expected to facilitate pooling of data among imaging protocols.  相似文献   

14.
In this prospective study, we quantified the fast pseudo-diffusion contamination by blood perfusion or cerebrospinal fluid (CSF) intravoxel incoherent movements on the measurement of the diffusion tensor metrics in healthy brain tissue.Diffusion-weighted imaging (TR/TE = 4100 ms/90 ms; b-values: 0, 5, 10, 20, 35, 55, 80, 110, 150, 200, 300, 500, 750, 1000, 1300 s/mm2, 20 diffusion-encoding directions) was performed on a cohort of five healthy volunteers at 3 Tesla. The projections of the diffusion tensor along each diffusion-encoding direction were computed using a two b-value approach (2b), by fitting the signal to a monoexponential curve (mono), and by correcting for fast pseudo-diffusion compartments using the biexponential intravoxel incoherent motion model (IVIM) (bi). Fractional anisotropy (FA) and mean diffusivity (MD) of the diffusion tensor were quantified in regions of interest drawn over white matter areas, gray matter areas, and the ventricles.A significant dependence of the MD from the evaluation method was found in all selected regions. A lower MD was computed when accounting for the fast-diffusion compartments. A larger dependence was found in the nucleus caudatus (bi: median 0.86 10−3 mm2/s, Δ2b: −11.2%, Δmono: −14.4%; p = 0.007), in the anterior horn (bi: median 2.04 10−3 mm2/s, Δ2b: −9.4%, Δmono: −11.5%, p = 0.007) and in the posterior horn of the lateral ventricles (bi: median 2.47 10−3 mm2/s, Δ2b: −5.5%, Δmono: −11.7%; p = 0.007). Also for the FA, the signal modeling affected the computation of the anisotropy metrics. The deviation depended on the evaluated region with significant differences mainly in the nucleus caudatus (bi: median 0.15, Δ2b: +39.3%, Δmono: +14.7%; p = 0.022) and putamen (bi: median 0.19, Δ2b: +3.1%, Δmono: +17.3%; p = 0.015).Fast pseudo-diffusive regimes locally affect diffusion tensor imaging (DTI) metrics in the brain. Here, we propose the use of an IVIM-based method for correction of signal contaminations through CSF or perfusion.  相似文献   

15.
张首誉  包尚联  亢孝俭  高嵩 《物理学报》2013,62(20):208703-208703
通过核磁共振扩散张量成像(DTI)得到的特定值域的扩散各向异性指数(DAI) 可用于揭示水分子扩散椭球的形态学特征, 定量反映被成像物体内部水分子扩散的优势方向和强度, 间接得到被成像物体内部的组织结构信息. DAI的可靠性直接影响对DTI数据的分析和理解. 本文基于扩散张量椭球的几何学信息, 提出利用扩散椭球几何比(EGR)定量描述水分子扩散的各向异性程度. 通过蒙特卡罗模拟实验和对人脑DTI数据进行分析, 并与当前广泛应用的水分子扩散各向异性分数(FA)和近期文献提出的扩散椭球面积比(EAR)进行对比. 实验发现EGR在不同级别噪声影响下的对比度效果和抗噪性都优于FA及EAR. 而且EGR 加入了体积修正, 增强了盘形扩散张量情况下的敏感性, 能够更好地鉴别神经纤维束交叉情况, 对于各向异性扩散程度较高的白质深层和相对均质的表层都有较好的量化区分结果. 关键词: 扩散系数 各向异性扩散 扩散张量成像 扩散椭球几何比  相似文献   

16.
The aim of this study is to investigate the consequences of using different gradient schemes, number of repeated measurements and voxel size on the fractional anisotropy (FA) value in a diffusion tensor imaging (DTI) sequence on the cervical tract of the spinal cord. Twenty healthy volunteers underwent a total of 86 DTI axial acquisitions performed by using different voxel size and number of diffusion gradient directions (NDGDs). Three different diffusion gradient schemes were applied, named 6, 15 and 32 according to the NDGD. Furthermore, some acquisitions were repeated to investigate the effects of image averaging on FA value.  相似文献   

17.
We have performed MRI examinations to determine the water diffusion tensor in the brain of six patients who were admitted to the hospital within 12 h after the onset of cerebral ischemic symptoms. The examinations have been carried out immediately after admission, and thereafter at varying intervals up to 90 days post admission. Maps of the trace of the diffusion tensor, the fractional anisotropy and the lattice index, as well as maps of cerebral blood perfusion parameters, were generated to quantitatively assess the character of the water diffusion tensor in the infarcted area. In patients with significant perfusion deficits and substantial lesion volume changes, four of six cases, our measurements show a monotonic and significant decrease in the diffusion anisotropy within the ischemic lesion as a function of time. We propose that retrospective analysis of this quantity, in combination with brain tissue segmentation and cerebral perfusion maps, may be used in future studies to assess the severity of the ischemic event.  相似文献   

18.
This study investigated the properties of a class of rotationally invariant and symmetric (relative to the principal diffusivities) indices of the anisotropy of water self-diffusion, namely fractional anisotropy (FA), relative anisotropy (RA), and volume ratio (VR), with particular emphasis to their measurement in brain tissues. A simplified theoretical analysis predicted significant differences in the sensitivities of the anisotropy indices (AI) over the distribution of the principal diffusivities. Computer simulations were used to investigate the effects on AI image quality of three magnetic resonance (MR) diffusion tensor imaging (DTI) acquisition schemes, one being novel: the schemes were simulated on cerebral model fibres varying in shape and spatial orientation. The theoretical predictions and the results of the simulations were corroborated by experimentally determined spatial maps of the AI in a normal feline brain in vivo. We found that FA mapped diffusion anisotropy with the greatest detail and SNR whereas VR provided the strongest contrast between low- and high-anisotropy areas at the expense of increased noise contamination and decreased resolution in anisotropic regions. RA proved intermediate in quality. By sampling the space of the effective diffusion ellipsoid more densely and uniformly and requiring the same total imaging time as the published schemes, the novel DTI scheme achieved greater rotational invariance than the published schemes, with improved noise characteristics, resulting in improved image quality of the AI examined. Our findings suggest that significant improvements in diffusion anisotropy mapping are possible and provide criteria for the selection of the most appropriate AI for a particular application.  相似文献   

19.
20.
Diffusion weighted MRI is used clinically to detect and characterize neurodegenerative, malignant and ischemic diseases. The correlation between developing pathology and localized diffusion relies on diffusion-weighted pulse sequences to probe biophysical models of molecular diffusion-typically exp[-(bD)]-where D is the apparent diffusion coefficient (mm(2)/s) and b depends on the specific gradient pulse sequence parameters. Several recent studies have investigated the so-called anomalous diffusion stretched exponential model-exp[-(bD)(alpha)], where alpha is a measure of tissue complexity that can be derived from fractal models of tissue structure. In this paper we propose an alternative derivation for the stretched exponential model using fractional order space and time derivatives. First, we consider the case where the spatial Laplacian in the Bloch-Torrey equation is generalized to incorporate a fractional order Brownian model of diffusivity. Second, we consider the case where the time derivative in the Bloch-Torrey equation is replaced by a Riemann-Liouville fractional order time derivative expressed in the Caputo form. Both cases revert to the classical results for integer order operations. Fractional order dynamics derived for the first case were observed to fit the signal attenuation in diffusion-weighted images obtained from Sephadex gels, human articular cartilage and human brain. Future developments of this approach may be useful for classifying anomalous diffusion in tissues with developing pathology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号