共查询到20条相似文献,搜索用时 15 毫秒
1.
X. C. Lu L. Song T. T. Ding Y. L. Lin C. X. Xu 《Russian Journal of Electrochemistry》2017,53(4):366-373
The rapid and simple detection of bisphenol A is very important for the safety and reproduction of organisms. Here, a sensitive and reliable electrochemical sensor was established for bisphenol A detection based on the high amplification effect of copper sulfide-multi-walled carbon nanotube (CuS–MWCNT) nanocomposites. The flower-like CuS–MWCNT were successfully synthesized by a simple hydrothermal method accompanied by polyvinylpyrrolidone (PVP). Compared with bare glassy carbon electrode (GCE), CuS–MWCNT modified GCE could amplify the electrochemical signals in about ten times, which was attributed to the synergistic effect of CuS and MWCNT. The MWCNT could increase the specific surface area of electrodes and improve the electrode activity. The integration of CuS could further enhance the electrode conductivity as well as accelerate the electron transfer rate. Raman spectra and transmission electron microscope (TEM) were used to characterize the successful fabrication of CuS–MWCNT nanocomposites and its uniform and monodispersed morphology. Under optimizing conditions, the oxidation currents of bisphenol A via the differential pulse voltammetric (DPV) showed a good linear relationship with its concentration in a wide range of 0.5–100 μM, with a detection limit of 50 nM. This electrochemical sensor of bisphenol A provided a convenient and economical platform with high sensitivity and reproducibility, which had great potential in environmental monitoring. 相似文献
2.
Tanveer A. Tabish Hasan Hayat Aumber Abbas Roger J. Narayan 《Current Opinion in Electrochemistry》2021
Electrochemical biosensing systems coupled with graphene quantum dots (GQDs) have demonstrated suitability for cancer diagnostic strategies, particularly to identify the changes facilitating the early phases of tumorigenesis as well as to detect ultralow concentrations of biomarkers that distinguish between normal and malignant cells. GQDs, known as a novel class of zero-dimensional semiconductor nanocrystals, are tiny graphene particles arranged in a honeycomb structure with a size range of 1–50 nm. The size of these GQDs is comparable with the size of biomolecules, thereby providing an ideal platform to study biomolecules such as proteins, cells, and viruses. GQDs are a superior platform for specific and sensitive recognition of cancer biomarkers; they are highly synergistic with electrochemical sensors. This review will shed light on the recent advancements made in the field of GQD-based electrochemical sensors for early cancer detection, with the aim of highlighting the prospects for further development in cancer diagnostics. 相似文献
3.
Electrochemical biosensors are highly compatible with modern advancements in magnetic nanomaterials. In particular, the versatile nature of magnetic nanomaterials as a universal platform for selective isolation of diverse forms of cancer biomarkers in body circulation, is highly synergistic with electrochemical biosensors for elevating biosensing performance to unprecedented levels. Such diverse circulating target biomolecules include cell surface proteins of circulating tumor cells and extracellular vesicles (EVs), as well as circulating tumor nucleic acids (i.e. ctDNA/ctRNA). This focussed review serves to discuss the latest work in the fields of magnetic nanomaterials and electrochemistry to tackle existing analysis challenges of diverse circulating biomarkers in cancer. 相似文献
4.
Wenbei Zhang Jiuli Chang Jianhua Chen Fang Xu Feng Wang Kai Jiang Zhiyong Gao 《Research on Chemical Intermediates》2012,38(9):2443-2455
A novel electrochemical sensor for para-nitrophenol (p-NP) was constructed with graphene–Au composite containing 10 % Au (G–Au 10 %). In the composite, Au nanoparticles with the size of ca. 11 nm were regularly scattered on graphene sheet without aggregation, which offers dramatically higher electrocatalytic activity on the redox of K3[Fe(CN)6]/K4[Fe(CN)6] couple than sole Au nanoparticles. Compared to sole Au nanoparticles, the G–Au 10 % also exhibited dramatically improved electrocatalytic activity on the reduction of p-NP. Amperometric detection of p-NP at G–Au 10 % modified electrode displayed a wide linear range of 0.47–10.75 mM with detection limit of 0.47 μM and a high sensitivity of 52.85 μA/mM. Considering the thrifty in utilization of noble Au, the G–Au 10 % can be successfully applied as a low-cost and powerful sensing material for trace detection of p-NP. 相似文献
5.
In this paper, a simple, selective and reusable electrochemical biosensor for the sensitive detection of mercury ions (Hg2+) has been developed based on thymine (T)-rich stem–loop (hairpin) DNA probe and a dual-signaling electrochemical ratiometric strategy. The assay strategy includes both “signal-on” and “signal-off” elements. The thiolated methylene blue (MB)-modified T-rich hairpin DNA capture probe (MB-P) firstly self-assembled on the gold electrode surface via Au–S bond. In the presence of Hg2+, the ferrocene (Fc)-labeled T-rich DNA probe (Fc-P) hybridized with MB-P via the Hg2+-mediated coordination of T–Hg2+–T base pairs. As a result, the hairpin MB-P was opened, the MB tags were away from the gold electrode surface and the Fc tags closed to the gold electrode surface. These conformation changes led to the decrease of the oxidation peak current of MB (IMB), accompanied with the increase of that of Fc (IFc). The logarithmic value of IFc/IMB is linear with the logarithm of Hg2+ concentration in the range from 0.5 nM to 5000 nM, and the detection limit of 0.08 nM is much lower than 10 nM (the US Environmental Protection Agency (EPA) limit of Hg2+ in drinking water). What is more, the developed DNA-based electrochemical biosensor could be regenerated by adding cysteine and Mg2+. This strategy provides a simple and rapid approach for the detection of Hg2+, and has promising application in the detection of Hg2+ in real environmental samples. 相似文献
6.
An Y Tang L Jiang X Chen H Yang M Jin L Zhang S Wang C Zhang W 《Chemistry (Weinheim an der Bergstrasse, Germany)》2010,16(48):14439-14446
α‐Synuclein (α‐SYN) is a very important neuronal protein that is associated with Parkinson’s disease. In this paper, we utilized Au‐doped TiO2 nanotube arrays to design a photoelectrochemical immunosensor for the detection of α‐SYN. The highly ordered TiO2 nanotubes were fabricated by using an electrochemical anodization technique on pure Ti foil. After that, a photoelectrochemical deposition method was exploited to modify the resulting nanotubes with Au nanoparticles, which have been demonstrated to facilitate the improvement of photocurrent responses. Moreover, the Au‐doped TiO2 nanotubes formed effective antibody immobilization arrays and immobilized primary antibodies (Ab1) with high stability and bioactivity to bind target α‐SYN. The enhanced sensitivity was obtained by using {Ab2‐Au‐GOx} bioconjugates, which featured secondary antibody (Ab2) and glucose oxidase (GOx) labels linked to Au nanoparticles for signal amplification. The GOx enzyme immobilized on the prepared immunosensor could catalyze glucose in the detection solution to produce H2O2, which acted as a sacrificial electron donor to scavenge the photogenerated holes in the valence band of TiO2 nanotubes upon irradiation of the other side of the Ti foil and led to a prompt photocurrent. The photocurrents were proportional to the α‐SYN concentrations, and the linear range of the developed immunosensor was from 50 pg mL?1 to 100 ng mL?1 with a detection limit of 34 pg mL?1. The proposed method showed high sensitivity, stability, reproducibility, and could become a promising technique for protein detection. 相似文献
7.
Levetiracetam is one of the new generation anti–epileptic agents (also known as anticonvulsants or antiseizure drugs). Following its approval for marketing in 2000, levetiracetam has been widely used in the treatment of epilepsy due to its broad spectrum effects. One of the advantages of this antiseizure drug is its rapid and complete absorption after oral administration. It has also minimal drug–drug and food interactions, and shows more than 95% bioavailability. The determination of levetiracetam in various samples is carried out using several analytical methods including HPLC–based methods. HPLC–based methods are used for different pharmaceutical analyses and play an important role in drug monitoring during patient follow–ups. This review provides a summary of the HPLC–based methods used in the determination and quantification of levetiracetam in biological fluids and pharmaceutical preparations. 相似文献
8.
Manju Bhargavi Gumpu Noel Nesakumar Bhat Lakshmishri Ramachandra John Bosco Balaguru Rayappan 《Journal of Analytical Chemistry》2017,72(3):316-326
We report for the first time a cyclic voltammetric nitrate sensor with a low detection limit based on the immobilization of zinc oxide nanoparticles on the surface of the platinum working electrode using chitosan membrane. Cyclic voltammetric data demonstrated that zinc oxide nanoparticles can electrochemically reduce nitrate ions to ammonium ions with high conductivity. In order to estimate electroanalytical parameters for each of the nitrate concentrations, Gaussian and Lorentzian curve fitting algorithms were performed on cyclic voltammetric data. Among them, the best analytical performance results were obtained with Gaussian calibration linear model. The zinc oxide modified platinum electrode showed a linear response to nitrate ions over a concentration range from 0.1 to 2.0 mM with a low detection limit and high sensitivity of 10 nM and 39.91 μA/cm2 mM, respectively. The nitrate ion concentrations in drinking water samples were determined using Gaussian calibration linear model and the predicted, added nitrate ion concentration values showed good correlation. 相似文献
9.
Jérôme Dejeu Angéline Van der Heyden Nicolas Spinelli Eric Defrancq Liliane Coche-Guérente 《Current Opinion in Electrochemistry》2021
Aptamer-based electrochemical sensors are now developed for the detection of a wide variety of analytes including ions, low-molecular-weight molecules, proteins, and living cells. An aptamer-based sensor is an analytical device whose bio-sensing element (i.e. the aptamer) is immobilized on a transducer surface. Aptasensors have attracted great attention because of their high selectivity, sensitivity, and stability; they could be miniaturized and are of low production cost and offer extraordinary flexibility in the design of their assemblies. This review will emphasize recent developments of aptasensors using aptamers that are able to adopt the particular G-quadruplex (G4) conformations, which are secondary DNA structures formed from guanine-rich sequences. Indeed, G4 exhibits notable recognition properties inherent to their particular structuration. 相似文献
10.
Şahin Samet Kaya Şevval Üstündağ Zafer Caglayan Mustafa Oguzhan 《Journal of Solid State Electrochemistry》2022,26(4):907-915
Journal of Solid State Electrochemistry - Insulin hormone is of great importance for many diseases, especially for diabetes management. Therefore, different detection strategies have been used for... 相似文献
11.
Jing Zhang Meifeng Hou Guanyu Chen Huifang Mao Wenqian Chen Wenshen Wang Jinghua Chen 《中国化学快报》2021,32(11):3474-3478
Exosomal miRNAs, as potential biomarkers in liquid biopsy for cancer early diagnosis, have aroused widespread concern. Herein, an electrochemical biosensor based on DNA “nano-bridge” was designed and applied to detect exosomal microRNA-21 (miR-21) derived from breast cancer cells. In brief, the target miR-21 can specifically open the hairpin probe 1(HP1) labeled on the gold electrode (GE) surface through strand displacement reaction. Thus the exposed loop region of HP1 can act as an initiator sequence to activate the hybridization chain reaction (HCR) between two kinetically trapped hairpin probes: HP2 immobilized on the GE surface and biotin labeled HP3 in solution. Cascade HCR leads to the formation of DNA “nano-bridge” tethered to the GE surface with a great deal of “piers”. Upon addition of avidin-modified horseradish peroxidase (HRP), numerous HRP were bound to the formed “nano-bridge” through biotin-avidin interaction to arouse tremendous current signal. In theory, only a single miR-21 is able to trigger the continuous HCR between HP2 and HP3 until all of the HP2 are exhausted. Therefore the proposed biosensor achieved ultrahigh sensitivity toward miR-21 with the detection limit down to 168 amol/L, as well as little cross-hybridization even at the single-base-mismatched level. Successful attempts were also made in the detection of exosomal miR-21 obtained from the MCF-7 of breast cancer cell line. To our knowledge, this is the first attempt to built horizontal DNA nano-structure on the electrode surface for exosomal miRNAs detection. In a word, the high sensitivity, selectivity, low cost make the proposed method hold great potential application for early point-of-care (POC) diagnostics of cancer. 相似文献
12.
In this work, a novel sandwich-type electrochemical immunosensor based on host-guest interaction was fabricated for the detection of alpha-fetoprotein (AFP). Due to the large specific surface area of multiwalled carbon nanotubes and the unique supramolecular recognition ability of β-cyclodextrins, ferrocenecarboxylic acid (Fc) was incorporated into this sensor platform by host-guest interaction to generate an electrochemical signal. And β-cyclodextrins functionalized silver supported adamantine-modified glucose oxidase (GOD-CD-Ag), was used as a label to improve the analytical performance of the immunosensor by the dual amplification strategy. The obtained GOD-CD-Ag conjugates could convert glucose into gluconic acid with the formation of hydrogen peroxide (H2O2). And then silver nanoparticles could in situ catalyze the reduction of the generated H2O2, dramatically improving the oxidation reaction of Fc. The developed immunosensor shows a wide linear calibration range from 0.001 to 5.0 ng/mL with a low detection limit (0.2 pg/mL) for the detection of AFP. The method, with ideal reproducibility and selectivity, has a wide application prospect in clinical research. 相似文献
13.
Huili Ma Li Wang Zhiguang Liu 《International journal of environmental analytical chemistry》2016,96(2):161-172
In this work, ionic liquid–graphene nanosheets (IL–GNs) were synthesised and used as an enhanced material for sensitive detection of methyl parathion (MP) by electrochemical method. IL–GNs were characterised by UV–Vis spectroscopy, transmission electron microscopy (TEM), X-ray photo-electron spectroscopy (XPS), Fourier transform Infrared (FT-IR) spectroscopy and Raman spectroscopy, which confirmed that IL was successfully covered on the surface of GNs. Significantly, due to the coupling of excellent properties of GNs and IL, the IL–GNs-modified glassy carbon electrode (IL–GNs/GCE) showed higher signals for MP response than the GNs/GCE and bare GCE. At the IL–GNs/GCE, the peak currents increase linearly with the concentration of MP in the range of 5.3 ng/mL to 2.6 μg/mL with the detection limit of 1.1 ng/mL, which was better than other enzyme-based and enzymeless sensors. The IL–GNs-based electrochemical sensor was also successfully demonstrated for the detection of water sample with satisfactory results. Furthermore, the proposed electrochemical sensor exhibited satisfied stability and reproducibility. The simple sensing platform can be extended to detect other organophosphate pesticide. 相似文献
14.
Single-walled carbon nanotubes functionalized with poly-L-lysine (PLL-SWCNTs) were successfully prepared and were used as a biocompatible platform to immobilize α-fetoprotein antibody (anti-AFP) which was labeled with horseradish peroxidase (HRP). Then, anti-AFP-HRP/PLL-SWCNT nanocomposites were coated onto a Prussian blue (PB) film-modified glassy carbon electrode surface. Glutaraldehyde was used to further stabilize the biosensing interface through a cross-linking step. All unspecific sites were blocked by bovine serum albumin to fabricate a novel electrochemical immunosensor for α-fetoprotein determination. The immunosensor was characterized by voltammetry and electrochemical impedance spectroscopy. Based on the catalytic current response of H2O2, the experimental conditions for α-fetoprotein determination were optimized. Under optimal conditions, the current response was linearly related to α-fetoprotein concentration in the range of 0.05~10.0 and 10.0~50.0 ng/mL with a detection limit of 0.011 ng/mL. The immunosensor was successfully used for the determination of α-fetoprotein in human blood plasma. The results were satisfied with that obtained with ELISA, demonstrating a good accuracy of the immunosensor. 相似文献
15.
A tremendous effort has been provided in last two decades to develop efficient transition metal–based heterogeneous catalysts for the electrochemical water oxidation. Several approaches such as composition modulation, heteroatom doping, morphological development, particle size tuning, surface area enhancement, and control over electronic structure have been explored for the designing of the materials with improved water oxidation activity. As the electrochemical process is a surface phenomenon, surface structure plays a crucial role in controlling the water oxidation activity. Rational engineering of the catalyst surface by composition modulation, crystal facet tuning, and generating functional overlayer has been reported to enhance the water oxidation activity. Heteroatom doping, cationic and anionic deficiencies, and ultrathin 2D morphology are also found to promote electrochemical performance. In addition, engineering in the interface provides intrinsic improvement of the catalytic activity and stability for the electrochemical water oxidation. Although, surface and interface engineering of the catalyst has come out as the major factors in the electrochemical water oxidation, no dedicated review is available in this field. In this review, we have described the strategies of improving water oxidation activity of the catalysts by surface and interface engineering. The progress in this field discussed in detail; the challenges have been identified and addressed to attain a clear understanding in this field. 相似文献
16.
Saluma Samanman Apon Numnuam Warakorn Limbut Proespichaya Kanatharana Panote Thavarungkul 《Analytica chimica acta》2015
For the first time, a simple and highly sensitive label-free electrochemical carcinoembryonic antigen (CEA) immunosensor based on a cryogel electrode has been developed and tested. The as-prepared nanocomposite combined the advantages of the graphene, AuNPs and chitosan (AuNPs–GP–CS) together with the ease of preparing a cryogel coupled to a silver deposition, to act as a redox mediator, on a Au electrode. Under the optimal conditions, the decrease of the cyclic voltammetry (CV) silver peak current was proportional to the CEA concentration over a range of from 1.0 × 10−6 to 1.0 ng mL−1 with a detection limit of 2.0 × 10−7 ng mL−1. This AuNPs–GP–CS cryogel electrode gave a 1.7 times higher sensitivity and 25 times lower detection limit than the non-cryogel electrode. Moreover, the proposed electrochemical immunosensor exhibited good selectivity, reproducibility and stability. When applied to analyse clinical serum samples, the data determined by the developed immunosensor were in agreement with those obtained by the current hospital analysis system (enzyme linked fluorescent assay) (P > 0.05), to indicate that the immunosensor would be potentially useful for clinical diagnostics. 相似文献
17.
Hao Fan Rong Xing Ying Xu Qingjiang Wang Pingang He Yuzhi Fang 《Electrochemistry communications》2010,12(4):501-504
This communication reports on a new electrochemical method to detect the hybridization specificity by using host–guest recognition technique. A hairpin DNA with dabcyl-labeled at its 3′ and NH2 group at 5′ terminal was combined with CdS nanoparticle to construct a double-labeled probe (DLP), which could selectively hybridize with its target DNA in homogeneous solution. A β-CD modified Poly(N-acetylaniline) glassy carbon electrode was used for capturing the dabcyl label in DLP. When without binding with target DNA, the DLP kept its stem-loop structure which shielded the dabcyl molecule due to the loop of the hairpin DNA and CdS nanoparticle blocking dabcyl enter into the cavity of these β-CD molecules on the electrode. However, in present of complementary sequence, the target-binding DLP was incorporated into double stranded DNA, causing the DLP’s loop-stem structure opened and then the dabcyl was easily captured by the β-CD modified electrode. During electrochemical measurement, the signal from the dissolved Cd2+ was used for target DNA quantitative analysis. 相似文献
18.
The exploitation of the unique electrical properties of nanowires requires an effective assembly of nanowires as functional materials on a signal transduction platform. This paper describes a new strategy to assemble gold–platinum alloy nanowires on microelectrode devices and demonstrates the sensing characteristics to hydrogen peroxide. The alloy nanowires have been controllably electrodeposited on microelectrodes by applying an alternating current. The composition, morphology and alloying structures of the nanowires were characterized, revealing a single-phase alloy characteristic, highly monodispersed morphology, and controllable bimetallic compositions. The alloy nanowires were shown to exhibit electrocatalytic response characteristics for the detection of hydrogen peroxide, exhibiting a high sensitivity, low detection limit, and fast response time. The nanowire's response mechanism to hydrogen peroxide is also discussed in terms of the synergistic activity of the bimetallic binding sites, which has important implications for a better design of functional nanowires as sensing materials for a wide range of applications. 相似文献
19.
M. Sánchez A. González L. Sabio W. Zou R. Ramanathan V. Bansal J.M. Dominguez-Vera 《Materials Today Chemistry》2021
This study describes a new strategy for real-time detection of alcohol in saliva and sweat. Phosphotungstic acid (PTA) is a colorless, photoelectrochromic heteropoly acid that can be reduced by ethanol under ultraviolet (UV) radiation to produce an intense blue color. This system has useful properties in the development of a new alcohol sensor: (1) the blue color can be detected by the naked eye or mobile camera, even at low ethanol concentrations; (2) color intensity is proportional to ethanol concentration; and (3) once exposed to air, reduced PTA is subsequently oxidized and returns to its colorless state offering sensor reusability. Based on these properties, we developed a simple device consisting of a PTA-impregnated non-woven material and a low-cost UV lamp that can be used to evaluate the alcohol concentration in saliva and sweat. We further enhanced the practical applicability of this sensor by demonstrating the integration of digital image analysis, multivariate analysis, and mobile camera technology with this sensor. This device can be potentially used in vehicles as a convenient, reusable alcohol sensor for drivers. 相似文献
20.
Lai Cui Zhang Yujin Liu Xigui Liu Shiyu Li Bisheng Zhang Mingming Qin Lei Yi Huan Li Minfang Li Ling Fu Yukui He Jiangfan Chen Liang 《Analytical and bioanalytical chemistry》2019,411(28):7499-7509
Analytical and Bioanalytical Chemistry - In this study, a sensitive amplification strategy for Pb2+ detection using reduced graphene oxide (RGO) and gold nanoparticles (AuNPs) was proposed.... 相似文献