首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

An ion imprinted polymer coated onto magnetite (Fe3O4) nanoparticles is shown to be a useful magnetic sorbent for the fairly selective preconcentration of vanadium. The sorbent was prepared by radical copolymerization of 3-(triethoxysilyl)propyl methacrylate (the monomer), ethylene glycol dimethacrylate (the cross-linker), and the vanadium(IV) complex of 1-(2-pyridylazo-2-naphthol) in the presence of magnetite nanoparticles. The material was characterized by IR spectroscopy, scanning electron microscopy, and thermal analysis. The vanadium(IV) ions were removed from the imprint by a solution containing thiourea and HCl, and the eluent was submitted to AAS. The analytical efficiency and relative standard deviation are 99.4 and ±2.3 %, respectively, under optimum conditions, and the limit of detection is 20 ng mL−1. The method was successfully applied to the preconcentration and determination of vanadium(IV) ions in crude oil.

An ion imprinted polymer is coated on to magnetite nanoparticles as a useful magnetic sorbent for the fairly selective preconcentration of vanadium which can be used for vanadium determination in crude oil.

  相似文献   

2.
Cui  Haochen  Wu  Jayne  Eda  Shigetoshi  Chen  Jiangang  Chen  Wei  Zheng  Lei 《Mikrochimica acta》2015,182(13):2361-2367

A label-free and single-step method is reported for rapid and highly sensitive detection of bisphenol A (BPA) in aqueous samples. It utilizes an aptamer acting as a probe molecule immobilized on a commercially available array of interdigitated aluminum microelectrodes. BPA was quantified by measuring the interfacial capacitance change rate caused by the specific binding between bisphenol A and the immobilized aptamer. The AC signal also induces an AC electrokinetic effect to generate microfluidic motion for enhanced binding. The capacitive aptasensor achieves a limit of detection as low as 10 fM(2.8 fg ⋅ mL − 1) with a 20 s response time. The method is inexpensive, highly sensitive, rapid and therefore provides a promising technology for on-site detection of BPA in food and water samples.

A. AC electrokinetics effect plays a vital role in BPA detection by introducing microfluidic movement to accelerate the molecular transport to the electrode surface.

B. The ACEK capacitive aptasensor has a limit of detection as low as 10 fM (2.8 fg ⋅ mL − 1) with a 20-s response time.

  相似文献   

3.

We have investigated the gas sensing properties of ZnO thin films (100 to 200 nm thickness) deposited by room-temperature radio frequency magnetron sputtering. The sensitivity of the films to ethanol vapor was measured in the 10 to 50 ppm concentration range at operating temperatures between 200 and 400 °C. A synergetic effect of decreasing grain size and increasing operating temperature was observed towards the improvement of the sensitivity, reaching a value of 54 and a limit of detection as low as 0.61 ppm. The decrease in the grain size resulted in prolonged response time but faster recovery. In any case, both response time and recovery time are < 400 s. The results demonstrate that room-temperature magnetron sputtering is a viable approach to enhance the performances of ZnO films in sensors for ethanol vapor.

Sensor response for ZnO films in presence of 50 ppm ethanol as a function grain size and temperature

  相似文献   

4.
Wang  Ruiling  Yuan  Yanan  Yang  Xun  Han  Yehong  Yan  Hongyuan 《Mikrochimica acta》2015,182(13):2201-2208

Microparticles were synthesized by suspension copolymerization of the synthetic ionic liquid (IL) 1-allyl-3-methyl-imidazolium bromide with ethylene glycol dimethacrylate. The particles have a regular spherical shape and an average diameter of 65 ± 24 μm. Their affinity for the fluoroquinolone antibiotics ofloxacin (OFL), lomefloxacin (LOM) and ciprofloxacin (CIP) is much higher than that of the blank polymer (not containing an IL), of polymers using methacrylic acid as functional monomer, of hydrophilic-lipophilic balanced sorbents, and of C18 sorbents. The microparticles were applied to the solid-phase extraction and rapid preconcentration of the fluoroquinolones from urine which then were quantified by HPLC. The calibration plot covers the 0.05 to 20 μg mL−1 concentration range, and the average recoveries at three spiking levels range from 93.6 to 103.7 %, with RSD of ≤5.7 %. The method was successfully applied to the determination of fluoroquinolones in spiked urine.

Microparticles covalently functionalized with an ionic liquid ([Amim][Br]) were synthesized by suspension copolymerization and show higher affinity for fluoroquinolones than other sorbents. The microparticles were used as a sorbent for solid-phase extraction and preconcentration of three fluoroquinolones from urine.

  相似文献   

5.
Chu  Chengchao  Li  Long  Li  Shuai  Li  Meng  Ge  Shenguang  Yu  Jinghua  Yan  Mei  Song  Xianrang 《Mikrochimica acta》2013,180(15):1509-1516

We report on an ultrasensitive fluorescence immunoassay for human chorionic gonadotrophin antigen (hCG). It is based on the use of silica nanoparticles coated with a copolymer (prepared from a fluorene, a phenylenediamine, and divinylbenzene; PF@SiO2) that acts as a fluorescent label for the secondary monoclonal antibody to β-hCG antigen. In parallel, Fe3O4 nanoparticles were coated with polyaniline, and these magnetic particles (Fe3O4@PANI) served as a solid support for the primary monoclonal antibody to β-hCG antigen. The PF@SiO2 exhibited strong fluorescence and good dispersibility in water. A fluorescence sandwich immunoassay was developed that enables hCG concentrations to be determined in the 0.01–100 ng·mL−1 concentration range, with a detection limit of 3 pg·mL−1.

Fluorescence detection of prepared immune reagent nano-composites using the fluorescence cell

  相似文献   

6.
Liu  Guangyang  Yang  Xin  Li  Tengfei  Yu  Hailong  Du  Xinwei  She  Yongxin  Wang  Jing  Wang  Shanshan  Jin  Fen  Jin  Maojun  Shao  Hua  Zheng  Lufei  Zhang  Yanxin  Zhou  Pan 《Mikrochimica acta》2015,182(11):1983-1989

We report on a method for the determination of the herbicide atrazine in tap water samples using melamine-modified gold nanoparticles (Mel-AuNPs). If a solution containing atrazine is added to a solution of such NPs, a color change occurs from wine-red to blue. This is due to a transition from monodisperse to aggregated Mel-AuNPs and caused by strong hydrogen bonding between atrazine and melamine. The color change can be monitored by a UV–vis spectrophotometer or with bare eyes. The ratio of the absorbances at 640 and 523 nm is linearly related to the logarithm of the atrazine concentration in the 0.165 to 16.5 μM range, and (with different slope) in the 16.5 μM to 330 μM range. The detection limit of atrazine is as low as 16.5 nM (S/N = 3). The method was successfully applied to the determination of atrazine in spiked tap water and gave recoveries that ranged from 72.5 % to 102.3 %.

  相似文献   

7.
We report on the time-resolved detection of the three fluoroquinolone (FQs) antibiotics ciprofloxacin (CIP), enrofloxacin (ENR) and flumequine (FLU). On addition of terbium(III) ions, the terbium(III)-FQs chelates are formed in-situ in an on-capillary derivatization reaction of a microfluidic system. The laser-induced terbium(III)-sensitized luminescence of the chelates is measured at excitation/emission wavelengths of 337/545 nm. The analytes can be separated and quantified within less than 4 min. A solid phase extraction step for analyte preconcentration can be included prior to chelation and microchip capillary electrophoresis. The analytical ranges of the calibration graphs for CIP, ENR and FLU are from 10.6 to 60.0, 10.3 to 51.0, and 11.5 to 58.8 ng mL?1, respectively, and the detection limits are 3.2, 3.1 and 3.6 ng mL?1, respectively. The precision was established at two concentration levels of each analyte and revealed relative standard deviations in the range from 3.0 to 10.2 %. The method was applied to the analysis of FQ-spiked water samples. Figure
We report on the time-resolved detection of the three fluoroquinolone antibiotics. The analytes can be separated and quantified within less than 4 min. A solid phase extraction step for analyte preconcentration can be included prior to chelation and microchip capillary electrophoresis.  相似文献   

8.
Pan  Feng  Mao  Jie  Chen  Qiang  Wang  Pengbo 《Mikrochimica acta》2013,180(15):1471-1477

Magnetic Fe3O4@SiO2 core shell nanoparticles containing diphenylcarbazide in the shell were utilized for solid phase extraction of Hg(II) from aqueous solutions. The Hg(II) loaded nanoparticles were then separated by applying an external magnetic field. Adsorbed Hg(II) was desorbed and its concentration determined with a rhodamine-based fluorescent probe. The calibration graph for Hg(II) is linear in the 60 nM to 7.0 μM concentration range, and the detection limit is at 23 nM. The method was applied, with satisfying results, to the determination of Hg(II) in industrial waste water.

  相似文献   

9.
Ju  Ke-Jian  Feng  Jin-Xia  Feng  Jiu-Ju  Zhang  Qian-Li  Xu  Tian-Qi  Wei  Jie  Wang  Ai-Jun 《Mikrochimica acta》2015,182(15):2427-2434

A nanocomposite consisting of coral-like gold nanostructures on reduced graphene oxide (RGO) was synthesized with the assistance of dimethylbiguanide (DMBG). It was then fabricated on a glassy carbon electrode, coating with cysteamine in order to enable the immobilization of acetylcholinesterase (AChE) as a model enzyme whose activity of hydrolyzing the substrate of acetylthiocholine is inhibited by the pesticide triazophos. The biosensor has response to acetylthiocholine in the 0.3 ~ 300 μM concentration range at 0.65 V (vs. SCE). The inhibition of the enzyme by triazophos can be determined in concentrations of up to 210 ppb, with a detection limit of 0.35 ppb of triazophos (S/N = 3). The biosensor is highly reproducible and acceptably stable.

Coral-like gold nanostructures supported on reduced graphene oxide were synthesized with the assistance of dimethylbiguanide to fabricate an acetylcholinesterase (AChE) biosensor, which exhibited high reproducibility and good stability, providing a good platform for the detection of organophosphorus pesticides.

  相似文献   

10.
Zheng  Dongyun  Liu  Xiaojun  Zhu  Shanying  Cao  Huimin  Chen  Yaguang  Hu  Shengshui 《Mikrochimica acta》2015,182(15):2403-2410

We describe an electrochemical sensor for nitric oxide that was obtained by modifying the surface of a nanofiber carbon paste microelectrode with a film composed of hexadecyl trimethylammonium bromide and nafion. The modified microelectrode displays excellent catalytic activity in the electrochemical oxidation of nitric oxide. The mechanism was studied by scanning electron microscopy and cyclic voltammetry. Under optimal conditions, the oxidation peak current at a working voltage of 0.75 V (vs. SCE) is related to the concentration of nitric oxide in the 2 nM to 0.2 mM range, and the detection limit is as low as 2 nM (at an S/N ratio of 3). The sensor was successfully applied to the determination of nitric oxide released from mouse hepatocytes.

NO electrochemical sensor based on CTAB-Nafion/CNFPME was fabricated through a simple method and applied to detect NO released from mouse hepatocytes successfully.

  相似文献   

11.
Chen  Lijian  Wang  Nan  Wang  Xindong  Ai  Shiyun 《Mikrochimica acta》2013,180(15):1517-1522

Platinum nanoparticles (Pt-NPs) with sizes in the range from 10 to 30 nm were synthesized using protein-directed one-pot reduction. The model globular protein bovine serum albumin (BSA) was exploited as the template, and the resulting BSA/Pt-NPs were studied by transmission electron microscopy, energy dispersive X-ray spectroscopy, and resonance Rayleigh scattering spectroscopy. The modified nanoparticles display a peroxidase-like activity that was exploited in a rapid method for the colorimetric determination of hydrogen peroxide which can be detected in the 50 μM to 3 mM concentration range. The limit of detection is 7.9 μM, and the lowest concentration that can be visually detected is 200 μM.

Pt-NPs were synthesized using BSA-directed one-pot reduction and BSA/Pt-NPs composite can effectively catalyze the oxidation of TMB producing blue solution in the presence of H2O2.

  相似文献   

12.

We describe a simple and efficient method for solid phase extraction and speciation of trace quantities of arsenic. It is based on the use of functionalized aluminum oxide nanoparticles and does not require any oxidation or reduction steps. The experimental parameters affecting extraction and quantitation were optimized using fractional factorial design methods. Adsorbed arsenic was eluted from the sorbent with 1 M hydrochloric acid and determined by graphite furnace atomic absorption spectrometry. Preconcentration factors up to 750 were achieved depending on the sample volume. Studies on potential interferences by various anions and cations showed the method to be highly selective. Under optimum conditions, the calibration plots are linear in the 5.0 to 280 ng L−1 and 8.0 to 260 ng L−1 concentration ranges for As(III) and total arsenic, respectively. The detection limits (calculated for S/N ratios of 3) are 1.81 and 1.97 ng L−1 for As(III) and total arsenic, respectively. The method was successfully applied to the determination and speciation of arsenic in (spiked) environmental, food and biological samples and gave good recoveries. The method was validated using a certified geological reference material.

Novel functionalized Al2O3 nanoparticles were synthesized and used for speciation and determination of arsenic in different samples. The experimental variables were optimized using fractional factorial design that can save time and operational costs.

  相似文献   

13.

A molecularly imprinted polymer (MIP) for the specific retention of neopterin has been developed. A set of 6 polymers was prepared by radical polymerization under different experimental condition using methacrylic acid as functional monomer and ethylene glycol dimethacrylate as crosslinker, with the aim to understand their influence on the efficiency of the MIP. The performance of each MIP was tested in batch experiments via their binding capacity. The MIP prepared in the presence of nickel ions in dimethylsulfoxide-acetonitrile mixture (P4) exhibited the highest binding capacity for neopterin (260 μmol per gram of polymer). A selectivity study with two other pteridines demonstrated the polymer P4 also to possess the best selectivity.

A molecularly imprinted polymer for the specific retention of neopterin was developed. A set of 6 polymers was prepared under different experimental condition. The performance of each MIP was tested through their binding capacity. The MIP P4 prepared in the presence of nickel ions exhibited the highest binding capacity

  相似文献   

14.
Xu  Ti-Sen  Li  Xiang-Yong  Xie  Zhao-Hui  Li  Xue-Gui  Zhang  Hai-Ying 《Mikrochimica acta》2015,182(15):2541-2549

We report on a new electrochemical immunosensor for the carcinoembryonic antigen (CEA; a model analyte). First, poly(o-phenylenediamine) nanospheres (PPDNSs) were synthesized by using a wet-chemistry method. The nanospheres were utilized as the support for immobilizing horseradish peroxidase-labeled polyclonal rabbit anti-human CEA antibody (HRP-anti-CEA) on a pretreated glassy carbon electrode (GCE) using glutaraldehyde as a crosslinker. In the presence of target CEA, an antigen-antibody immunocomplex formed on the electrode. This results in a partial inhibition of the active center of HRP and decreases the activity of HRP in terms of H2O2 reduction. The performance and factors influencing the performance of the immunoelectrode were studied. Under optimal conditions, the reduction current obtained from the anti-CEA-conjugated HRP (best at a working voltage of −265 mV vs. Ag/AgCl) is proportional to the CEA concentration in the 0.01 to 60 ng mL−1 range, with a detection limit of 3.2 pg mL−1. Non-specific adsorption was not observed. Relative standard deviations for intra-assay and inter-assay are <8.3 % and <9.7 %, respectively. The method was applied to the analysis of nine human serum samples, and a good relationship was found between the electrochemical immunoassay and the commercialized ELISA kit for human CEA.

A new electrochemical immunosensor based on poly(o-phenylenediamine) nanospheres was developed for the rapid detection of carcinoembryonic antigen via the inhibition of enzymatic activity.

  相似文献   

15.

A simple, sensitive and accurate method was developed for solid-phase extraction and preconcentration of trace levels of gold in various samples. It is based on the adsorption of gold on modified oxidized multi-walled carbon nanotubes prior to its determination by graphite furnace atomic absorption spectrometry. The type and volume of eluent solution, sample pH value, flow rates of sample and eluent, sorption capacity and breakthrough volume were optimized. Under these conditions, the method showed linearity in the range of 0.2–6.0 ng L−1 with coefficients of determination of >0.99 in the sample. The relative standard deviation for seven replicate determinations of gold (at a level of 0.6 ng L−1) is ±3.8 %, the detection limit is 31 pg L−1 (in the initial solution and at an S/N ratio of 3; for n = 8), and the enrichment factor is 200. The sorption capacity of the modified MWCNTs for gold(III) is 4.15 mg g−1. The procedure was successfully applied to the determination of gold in (spiked) water samples, human hair, human urine and standard reference material with recoveries ranging from 97.0 to 104.2 %.

A sorbent based on modified carbon nanotubes was prepared and used to extract gold ion from various samples prior to its determination by graphite furnace atomic absorption spectrometry

  相似文献   

16.
Mei  He  Wu  Wenqin  Yu  Beibei  Li  Yibin  Wu  Huimin  Wang  Shengfu  Xia  Qinghua 《Mikrochimica acta》2015,182(11):1869-1875

Co@Pt core-shell nanoparticles (NPs) were synthetized by a two-step reductive method using carbon (Vulcan XC-72) as a solid support. The NPs were characterized by X-ray diffraction, field emission gun scanning electron microscopy, energy dispersive X-ray spectroscopy, and transmission electron microscopy. Their electrochemical performance was evaluated by cyclic voltammetry, electrochemical impedance spectroscopy and chronoamperometry, and these showed that the Co@Pt NPs display an electrocatalytic activity towards the oxidation of glucose that is much better than that of plain Pt NPs. Under optimized conditions and at pH 7.0, the oxidation current of glucose at a working potential of −50 mV (vs. SCE) is linearly related to its concentration in the 1.0 to 30 mM range, and the detection limit is 0.3 mM (S/N = 3). It therefore covers the clinical range. The sensor also exhibits excellent stability and repeatability.

Co@Pt core-shell nanoparticles (NPs) display an electrocatalytic activity towards the oxidation of glucose that is much better than that of plain Pt NPs. The oxidation current for glucose is linearly related to its concentration in the 1.0 to 30 mM range, and the detection limit is 0.3 mM (S/N =3).

  相似文献   

17.
Zare  Fahimeh  Ghaedi  Mehrorang  Daneshfar  Ali 《Mikrochimica acta》2015,182(11):1893-1902

The solid phase extraction (SPE) is described for preconcentration of the antidepressant drugs amitriptyline and nortriptyline prior to their determination by HPLC with UV detection. It is based on the use of water-dispersible core-shell nanoparticles (NPs) of the Fe3O4@ZrO2@N-cetylpyridinium type. The positively charged surfactant N-cetylpyridinium forms mixed aggregates with the drugs on the surface of the core-shell and thereby improves the adsorption of amitriptyline and nortriptyline through hydrophobic and/or ionic interactions. Their extraction depends on the type and amount of surfactant, sample pH, extraction time, desorption conditions, sample volume and amount of NPs that were optimized by application of experimental design. The enrichment factors are 220 and 250, respectively, for amitriptyline and nortriptyline, and the detection limits are 0.04 and 0.08 ng·mL‾1. This protocol enables accurate and precise quantification of the two drugs in complex and low content samples. It was applied to the determination of the two drugs in plasma samples with relative recoveries in the range from 89 to 105 % and RSDs less than 4 %.

  相似文献   

18.
Ma  Mingyang  Zheng  Xingwang 《Mikrochimica acta》2015,182(13):2193-2199

We report on the preparation of fluorescent silica nanoparticles (SiNPs) modified with chitosan and lucigenin by using a reverse microemulsion method. The introduction of chitosan to the lucigenin doped SiNPs is shown to improve the fluorescence quantum yield. The modified SiNPs were used as fluorescent markers in an aptamer-based method for selective determination of thrombin. In this protocol, thrombin was sandwiched between streptavidin-coated magnetic beads and the fluorescent SiNPs modified with a thrombin-binding aptamer. The method was successfully applied to the determination of thrombin in human serum and showed a detection limit as low as 0.02 nM. In our perception, the protocol presented here is promising in that such SiNPs may be applied to the sensitive fluorescent detection of other analytes by changing the corresponding aptamer.

The introduction of chitosan to the lucigenin doped SiNPs is shown to improve the fluorescence quantum yield. The modified SiNPs were used as fluorescent markers in an aptamer-based method for selective determination of thrombin. The effect of chitosan concentration on fluorescence intensity of lucigenin/SiO2 nanoparticles (the volume of chitosan solution is 100 μL)

  相似文献   

19.
Feng  Zhongmin  Guo  Tingting  Jiang  Zhiwen  Sun  Ting 《Mikrochimica acta》2015,182(15):2419-2425

We have investigated the possibility of sampling ammonium ion using the diffusive-gradients-in-thin-films technique (DGT) by introducing a novel binding agent that is based on micro-sized zeolite. The performance of zeolite-DGT was characterized by measurement of the following parameters: (1) the diffusion coefficient of ammonium ion in hydrogel; (2) the adsorption rate of ammonium ion by the zeolite binding gel; (3) the elution efficiency, and (4) the effects of pH, ionic strength and interfering ions on DGT. The method was validated by studying the uptake of ammonium ion from in freshwaters by zeolite gels which was found to be fast enough to meet the requirements of DGT. The concentrations determined via DGT agreed well with the concentrations determined in bulk solutions. Sampling of ammonium ion using zeolite-DGT was consistent over the pH 3 to 8 range and the 0.001 to 10 mM ionic strength range. The method also performs predictably in natural waters containing various metal ions. The technique is considered to be a viable passive tool for sampling ammonium from aqueous solutions.

Schematic representation of the principle of DGT and the determination of mass accumulated on the binding gel.

  相似文献   

20.

We are describing immunochromatographic test strips with smart phone-based fluorescence readout. They are intended for use in the detection of the foodborne bacterial pathogens Salmonella spp. and Escherichia coli O157. Silica nanoparticles (SiNPs) were doped with FITC and Ru(bpy), conjugated to the respective antibodies, and then used in a conventional lateral flow immunoassay (LFIA). Fluorescence was recorded by inserting the nitrocellulose strip into a smart phone-based fluorimeter consisting of a light weight (40 g) optical module containing an LED light source, a fluorescence filter set and a lens attached to the integrated camera of the cell phone in order to acquire high-resolution fluorescence images. The images were analysed by exploiting the quick image processing application of the cell phone and enable the detection of pathogens within few minutes. This LFIA is capable of detecting pathogens in concentrations as low as 105 cfu mL−1 directly from test samples without pre-enrichment. The detection is one order of magnitude better compared to gold nanoparticle-based LFIAs under similar condition. The successful combination of fluorescent nanoparticle-based pathogen detection by LFIAs with a smart phone-based detection platform has resulted in a portable device with improved diagnosis features and having potential application in diagnostics and environmental monitoring.

The successful combination of fluorescent nanoparticle-based pathogen detection by lateral flow immunoassay with a smart phone-based detection platform has resulted in a portable device that enables rapid and reliable bacterial detection holding large potential in diagnostics and environmental monitoring

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号