首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We developed a method for the analysis of multiplexed double-stranded DNA (dsDNA) samples complexed to various intercalating dyes using entangled polymer solution. A commercial single-column capillary electrophoresis (CE) instrument with diode array detection was used for multiplexed detection of DNA samples by addition of intercalating fluorescent molecules. A Phi X174HinfI and a pGEM DNA ladder (1 mg/mL) were used for the electrophoretic separation of dsDNA fragments ranging in size from 24 to 726 and 36 to 2645 bp, respectively. The results suggested that simultaneous electrophoretic separation of different DNA ladders multiplexed with different dyes could be performed in the same capillary yielding fast DNA sizing separations. CE analysis, which is often overpowered by slab gel in sample throughput, could now overcome this disadvantage by allowing multiplexed sample analysis in a fraction of the time needed for slab gel analysis. The separation efficiency of stained DNA molecules with both dyes were dramatically improved with buffers containing a large cation such as tetrapentylammonium ion (Npe(4) (+)) as the only cation in the buffer.  相似文献   

2.
A miniaturized, integrated and automated system based on capillary fluidics has been developed for nanoliter DNA analysis directly from cheek cells. All steps for DNA analysis, including injecting aqueous reagents and DNA samples, mixing the solutions together, thermal cell lysis, polymerase chain reaction (PCR), transfer and injection of PCR product, separation, sizing and detection of those products are performed in a capillary-based integrated system. A small amount of cheek cells collected by a plastic toothpick is directly dissolved in the PCR cocktail in a plastic vial or mixed on-line with a small volume of PCR cocktail (125 nl) in the capillary. After thermal cell lysis and PCR in a microthermal cycler, the DNA fragments are mixed with DNA size standards and transferred to a micro-cross for injection and separation by capillary gel electrophoresis. Programmable syringe pumps, switching valves, multiposition and freeze-thaw valves are used for microfluidic control in the entire system. This work establishes the feasibility of performing all the steps of DNA analysis from real samples in a capillary-based nanoliter integrated system.  相似文献   

3.
A novel, rapid and efficient separation method is described for the analysis of double stranded (ds) DNA fragments in the form of horizontal ultra-thin-layer agarose gel electrophoresis. This separation technique combines the multilane, high-throughput separation format of agarose slab gel electrophoresis with the excellent performance of capillary electrophoresis. The electrophoretic separation of the fluorophore (Cy5)-labeled dsDNA molecules were imaged in real time by a scanning laser-induced fluorescence/avalanche photodiode detection system. Effects of the gel concentration (Ferguson plot) and separation temperature (Arrhenius plot) on the migration characteristics of the DNA fragments are discussed. An important genotyping application is also shown by characterizing the polymorphic region (2× or 4×48 base pair repeats) of the dopamine D4 receptor gene (D4DR, exon III region) for ten individuals, using PCR technology with Cy5-labeled primers and ultra-thin-layer agarose gel electrophoresis.  相似文献   

4.
In this paper, we describe the use of an integrated circuit (IC) microchip system as a detector in multiplex capillary electrophoresis (CE). This combination of multiplex capillary gel electrophoresis and the IC microchip technology represents a novel approach to DNA analysis on the microchip platform. Separation of DNA ladders using a multiplex CE microsystem of four capillaries was monitored simultaneously using the IC microchip system. The IC microchip-CE system has advantages such as low cost, rapid analysis, compactness, and multiplex capability, and has great potential as an alternative system to conventional capillary array gel electrophoresis systems based on charge-coupled device (CCD) detection.  相似文献   

5.
Large-scale genotyping, mapping and expression profiling require affordable, fully automated high-throughput devices enabling rapid, high-performance analysis using minute quantities of reagents. In this paper, we describe a new combination of microwell polymerase chain reaction (PCR) based DNA amplification technique with automated ultrathin-layer gel electrophoresis analysis of the resulting products. This technique decreases the reagent consumption (total reaction volume 0.75-1 microL), the time requirement of the PCR (15-20 min) and subsequent ultrathin-layer gel electrophoresis based fragment analysis (5 min) by automating the current manual procedure and reducing the human intervention using sample loading robots and computerized real time data analysis. Small aliquots (0.2 microL) of the submicroliter size PCR reaction were transferred onto loading membranes and analyzed by ultrathin-layer gel electrophoresis which is a novel, high-performance and automated microseparation technique. This system employs integrated scanning laser-induced fluorescence-avalanche photodiode detection and combines the advantages of conventional slab and capillary gel electrophoresis. Visualization of the DNA fragments was accomplished by "in migratio" complexation with ethidium bromide during the electrophoresis process also enabling real time imaging and data analysis.  相似文献   

6.
An integrated system for DNA sequencing based on a nanoreactor for cycle-sequencing reaction coupled with on-line capillary zone electrophoresis (CZE) for purification and capillary gel electrophoresis (CGE) for separation is presented. Less than 100 nl of premixed reagent solution, which includes dye-labeled terminator pre-mix, bovine serum albumin and template, was hydrodynamically injected into a fused-silica capillary (75 microm I.D.) inside a laboratory-made microthermocycler for cycle sequencing reaction. In the same capillary, the reaction products were purified by CZE followed by on-line injection of the DNA fragments into another capillary for CGE. Over 540 base pairs (bp) of DNA can be separated and the bases called for single-standed DNA with 0.9% error rate. The total time was about 3.5 h, or a cycle time of 2 h with staggered operation. For double-stranded DNA, a longer reaction time was required and base calling up to 490 bp with 1.2% error rate was achieved. The whole system is readily adaptable to automated multiplex operation for DNA sequencing or polymerase chain reaction analysis.  相似文献   

7.
DNA analysis plays a great role in genetic and medical research, and clinical diagnosis of inherited diseases and particular cancers. Development of new methods for high throughput DNA analysis is necessitated with incoming of post human genome era. A new powerful analytical technology, called microchip capillary electrophoresis (MCE), can be integrated with some experimental units and is characterized by high-speed, small sample and reagent requirements and high-throughput. This new technology, which has been applied successfully to the separation of DNA fragments, analysis of polymerase chain reaction (PCR) products, DNA sequencing, and mutation detection, for example, will become an attractive alternative to conventional methods such as slab gel electrophoresis, Southern blotting and Northern blotting for DNA analysis. This review is focused on some basic issues about DNA analysis by MCE, such as fabrication methods for microchips, detection system and separation schemes, and several key applications are summarized.  相似文献   

8.
An integrated on-line system is developed for DNA sequencing at the nanoliter scale. The technique involves the use of a nanoreactor for small-volume cycle-sequencing reaction, capillary zone electrophoresis (CZE) for purification of the sequencing fragments, and capillary gel electrophoresis (CGE) for separation of the purified DNA fragments. The nanoreactor and CZE are integrated into one capillary, where a 100-nl dye-labeled terminator cycle-sequencing reaction is carried out followed by CZE to separate excess dye-labeled terminators from the sequencing fragments. On-line electrokinetic injection of the purified DNA fragments into the CGE system is accomplished at a small-volume tee connector by which the CZE capillary is interfaced to the CGE system. The utility of the system is demonstrated in sequencing nanoliter volumes of single-stranded DNA (M13mp18) and double-stranded DNA (pGEM). The use of voltage to drive both CZE and CGE makes it feasible for automation and future adaptation of the whole system to a microchip.  相似文献   

9.
A voltage‐programming‐based capillary gel electrophoresis method with a laser‐induced fluorescence detector was developed for the fast and highly sensitive detection of DNA molecules related to angiotensin‐converting enzyme insertion/deletion polymorphism, which has been reported to influence predisposition to various diseases such as cardiovascular disease, high blood pressure, myocardial infarction, and Alzheimer's disease. Various voltage programs were investigated for fast detection of specific DNA molecules of angiotensin‐converting enzyme insertion/deletion polymorphism as a function of migration time and separation efficiency to establish the effect of voltage strength to resolution. Finally, the amplified products of the angiotensin‐converting enzyme insertion/deletion polymorphism (190 and 490 bp DNA) were analyzed in 3.2 min without losing resolution under optimum voltage programming conditions, which were at least 75 times faster than conventional slab gel electrophoresis. In addition, the capillary gel electrophoresis method also successfully applied to the analysis of real human blood samples, although no polymorphism genes were detected by slab gel electrophoresis. Consequently, the developed voltage‐programming capillary gel electrophoresis method with laser‐induced fluorescence detection is an effective, rapid analysis technique for highly sensitive detection of disease‐related specific DNA molecules.  相似文献   

10.
Capillary zone electrophoresis and high-performance liquid chromatography were compared with regard to the separation of oligonucleotides and double-stranded DNA. Both anion-exchange and reversed-phase high-performance liquid chromatography on non-porous particles are considered to be superior to capillary electrophoresis in terms of speed and selectivity in the analysis of oligonucleotides up to 30 bases in length. Moreover, reversed-phase chromatography allows the simultaneous purification of detritylated oligonucleotides with recoveries > 90%. Compared with anion-exchange chromatography, there is no need for a subsequent desaltation step because the volatile buffer system can be readily evaporated. With regard to dsDNA, however, the resolving power of capillary electrophoresis cannot be matched by anion-exchange chromatography at present. Moreover, the combined use of hydroxyethylcellulose and ethidium bromide not only yielded a separation efficiency equal to that achieved by means of gel-filled capillaries but also avoids some of their limitations such as the destruction of the gel matrix at high current densities and the bias involved in electrokinetic injection.  相似文献   

11.
Large scale, high-resolution DNA fragment analysis, such as genotyping, mapping and genetic profiling requires an affordable, fully automated high-throughput gel electrophoresis based separation device that enables rapid, high-performance analysis in a wide molecular weight range. In this article a novel approach is described that greatly enhances the productivity of DNA fragment analysis by automating the current manual procedure and also reducing the separation time and human intervention from sample loading to data analysis. The ultrathin layer, multilane, high-performance agarose gel electrophoresis system employs integrated scanning laser induced fluorescence-avalanche photodiode detection and combines the advantages of conventional slab and capillary gel electrophoresis. The separation platform is fabricated in a way that the sieving matrix can be easily replaced in the separation cassette for each run. Visualization of the DNA fragments is accomplished by ‘in migratio' complexation during the electrophoresis process with ultra-sensitive fluorescent agents, also enabling real-time imaging and data analysis.  相似文献   

12.
CGE is a well-established separation technique for the analysis of biologically important molecules such as nucleic acids. The inherent high resolving power, rapid analysis times, excellent detection sensitivity, and quantification capabilities makes this method favorable compared to conventional manual polyacrylamide and agarose slab gel electrophoresis techniques. In this paper we introduce a novel single-channel capillary gel electrophoresis system with LED-induced fluorescence detection also utilizing a compact pen-shaped capillary cartridge design for automatic analysis of samples from a 96-well plate. To evaluate the suitability of the system, 1000 genomic DNA(gDNA) samples were analyzed in gel filled capillaries and detected by the microball ended excitation and emission optical fiber based LED-induced fluorescence detection system. Excellent migration time reproducibility of RSD <0.75% was obtained over the course of 1000 runs. The system rapidly distinguished between intact and degraded gDNA samples, therefore provided important information if they could be used for downstream quantitative PCR processing where high-quality intact gDNA was key. We envision that this novel system design will rapidly find new applications in both research and clinical diagnostic laboratories as a highly sensitive and easy to use bio-analytical approach.  相似文献   

13.
This paper describes a prototype instrument for high-throughput fraction collection with capillary array electrophoresis (CAE). The design of the system was based on a comprehensive collection approach, in which fractions from all capillaries were simultaneously collected in individual collection microwells in predefined time intervals. The location of the fractions in the microwells on the collection plate was determined by monitoring the individual zone velocities close to the end of each capillary. The collection microwell plate was fabricated from buffer-saturated agarose gel, which maintained permanent electrical contact with the separation capillaries during the collection process. Since the collection gel plate consisted of over 90% water, liquid evaporation from the collection wells was minimized. A 12-capillary array instrument was built with two-point detection using a side illumination scheme. The collection performance was demonstrated by reinjection of selected fractions of a double-stranded DNA (dsDNA) separation. The identity of collected DNA fragments was confirmed by PCR and sequencing.  相似文献   

14.
Liu T  Liang D  Song L  Nace VM  Chu B 《Electrophoresis》2001,22(3):449-458
A mixture of two polyoxybutylene-polyoxyethylene-polyoxybutylene (BEB) triblock copolymers (B6E46B6 and B10E271B10, respectively) was used as a new separation medium for separating double-stranded DNA (dsDNA) fragments by capillary electrophoresis (CE). The two block copolymer mixtures were designed to form mixed flower-like micelles in dilute solution and a homogeneous gel-like open-network with hydrophobic clusters as cross-linking points at higher polymer concentrations. Being a polyoxyalkylene block copolymer gel, the separation medium has some special advantages, including the temperature-dependent sol-gel transition that makes sample injection easy, and the self-coating of the inner capillary wall that makes experimental procedures simple and reproducible. Furthermore, it can shorten the elution time and further improve the separation resolution, especially for small dsDNA fragments, when compared with EPE-type separation media, e.g., F127 (E99P69E99, with P being polyoxypropylene) block copolymer gels formed by the closed packing of spherical micelles. Single base pair resolution can be achieved by using the new separation medium for dsDNA fragments up to over 100 base pairs.  相似文献   

15.
Dong Y  McGown LB 《Electrophoresis》2011,32(10):1209-1216
Sieving gels are used in capillary gel electrophoresis to resolve DNA strands of different lengths. For complex samples, however, such as those encountered in metagenomic analysis of microbial communities or biofilms, length-based separation may mask the true genetic diversity of the community since different organisms may contribute same-length DNA with different sequences. There is a need, therefore, for DNA separations based on both the length and sequence. Previous work has demonstrated the ability of guanosine gels (G-gels) to separate four single-stranded DNA 76-mers that differ by only a few A/G base substitutions. The goal of the present work is to determine whether G-gels could be combined with commercial sieving gels in order to simultaneously separate DNA based on both length and sequence. The results are given for the four 76-mers and for a standard dsDNA ladder. Commercial sieving gels were used alone and in combination with G-gels. For the 76-mers, the combined medium was less efficient than the G-gel alone but was able to achieve partial resolution. The combined medium was at least as effective as the sieving gel alone at resolving the denatured DNA ladder and showed indications of sequence-based resolution as well, as supported by MALDI-MS. The results show that the combined sieving gel/G-gel medium retains the selectivity of the individual media, providing a promising approach to simultaneous length- and sequence-based DNA separation for metagenomic analysis of complex systems.  相似文献   

16.
A fully integrated microdevice and process for forensic short tandem repeat (STR) analysis has been developed that includes sequence-specific DNA template purification, polymerase chain reaction (PCR), post-PCR cleanup and inline injection, and capillary electrophoresis (CE). Fragmented genomic DNA is hybridized with biotin-labeled capture oligos and pumped through a fluidized bed of magnetically immobilized streptavidin-coated beads in microchannels where the target DNA is bound to the beads. The bead-DNA conjugates are then transferred into a 250 nL PCR reactor for autosomal STR amplification using one biotin and one fluorescence-labeled primer. The resulting biotin-labeled PCR products are electrophoretically injected through a streptavidin-modified capture gel where they are captured to form a concentrated and purified injection plug. The thermally released sample plug is injected into a 14 cm long CE column for fragment separation and detection. The DNA template capture efficiency provided by the on-chip sequence-specific template purification is determined to be 5.4% using K562 standard DNA. This system can produce full 9-plex STR profiles from 2.5 ng input standard DNA and obtain STR profiles from oral swabs in about 3 hours. This fully integrated microsystem with sample-in-answer-out capability is a significant advance in the development of rapid, sensitive, and reliable micro-total analysis systems for on-site human identification.  相似文献   

17.
The advantages of berberine such as the anticancer1, antiinflammatory2 and no side effects of camptothecin1, have promoted the research in the mechanism of berberine with macrobiomolecules. In general, three different points of view have been presented on…  相似文献   

18.
Gao F  Tie C  Zhang XX  Niu Z  He X  Ma Y 《Journal of chromatography. A》2011,1218(20):3037-3041
The separation and sequencing of DNA are the main objectives of the Human Genome Project, and this project has also been very useful for gene analysis and disease diagnosis. Capillary electrophoresis (CE) is one of the most common techniques for the separation and analysis of DNA. DNA separations are usually achieved using capillary gel electrophoresis (CGE) mode, in which polymer gel is packed into the capillary. Compared with a traditional CGE matrix, a hydrophilic polymer matrix, which can be adsorb by the capillary wall has numerous advantages, including stability, reproducibility and ease of automation. Various water-soluble additives, such as linear poly(acrylamide) (PAA) and poly(N,N-dimethylacrylamide) (PDMA), have been employed as media. In this study, different star-shaped PDMA polymers were designed and synthesized to achieve lower polymer solution viscosity. DNA separations with these polymers avoid the disadvantages of high viscosity and long separation time while maintaining high resolution (10 bp between 271 bp and 281 bp). The influences of the polymer concentration and structure on DNA separation were also determined in this study; higher polymer concentration yielded better separation performance, and star-like polymers were superior to linear polymers. This work indicates that modification of the polymer structure is a potential strategy for optimizing DNA separation.  相似文献   

19.
Végvári A  Hjertén S 《Electrophoresis》2003,24(21):3815-3820
Recently we described the design of a hybrid microdevice for micro(nano)electrophoresis and electrochromatography, discussed its advantages and disadvantages compared to conventional microdevices and presented a few applications with low-molecular-weight samples. In this paper, we demonstrate the broad application range of this device using UV-based analyses of (i) peptides by free-zone electrophoresis and electrophoresis in a recently introduced gel (polyacrylamide cross-linked with allyl-beta-cyclodextrin), (ii) proteins by electrophoretic molecular-sieving in a polymer solution supplemented with SDS, (iii) DNA fragments by electrophoresis in the above gel, (iv) virus particles in this gel, as well as in free buffer and (v) bacteria in free buffer. To illustrate the advantages of the hybrid microdevice we can mention that electrophoresis of proteins in a polymer-containing buffer, supplemented with sodium dodecyl sulfate (SDS), in a 4.30 (2.75) cm long channel gave a resolution similar to that in conventional capillary electrophoresis in a 23.5 (18.6) cm long capillary and analysis times which were 15-fold shorter.  相似文献   

20.
In the age of genomics and proteomics, high-resolution separation techniques are routinely utilized in an integrated and automated fashion to solve formidable separation problems and provide the means for large-scale analysis of biological samples with excellent resolution. By automating the current manual procedures, capillary gel (CGE) and polymer-solution mediated electrophoresis greatly enhance the productivity of biopolymer analysis while also reducing both analysis time and the human intervention necessary from sample loading to data processing. The advent of this novel and high-performance bioseparation technique has made it possible to sequence the human genome and revealed global changes in the genome and proteome level, bringing about a revolutionary transition in our views of living systems on the molecular basis. CGE and polymer-solution mediated electrophoresis and related microseparation methods (e.g., electrophoresis microchips) are quickly becoming important separation and characterization tools in analytical biochemistry and molecular biology. This review gives an overview of the key application areas of DNA, protein, and complex carbohydrate analysis, and summarizes the latest developments on CGE column technology, including capillary coatings and sieving polymer matrices. Micropreparative aspects and related microseparation techniques are also discussed.  相似文献   