首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A selective and sensitive liquid chromatography tandem mass spectrometry method was developed for the simultaneous determination of salviaflaside and rosmarinic acid in rat plasma. Sample preparation was carried out through liquid–liquid extraction with ethyl acetate using curculigoside as internal standard (IS). The analytes were determined by selected reaction monitoring operated in the positive ESI mode. Chromatographic separation was performed on an Agilent Eclipse Plus C18 column (100 × 4.6 mm, 1.8 μm) with a mobile phase consisting of methanol–water–formic acid (50:50:0.1, v/v/v) at a flow rate of 0.3 mL/min. The run time was 1.9 min per sample and the injection volume was 5 μL. The method had an LLOQ of 1.6 ng/mL for salviaflaside and 0.94 ng/mL for rosmarinic acid in plasma. The linear calibration curves were fitted over the range of 1.6–320 ng/mL for salviaflaside and 0.94–188 ng/mL for rosmarinic acid in plasma with correlation coefficients (r2) >0.99. Intra‐ and inter‐day precisions (relative standard deviation) were < 13.5%, and accuracies (relative error) were between −8.6% and 14.5% for all quality control samples. The method was validated and applied to the pharmacokinetics of salviaflaside and rosmarinic acid in plasma after oral administration of Prunella vulgaris extract to rats.  相似文献   

2.
The aim of this study was to develop an analytical method to determine mequitazine in rat plasma and urine. Mequitazine was separated by UPLC–MS/MS equipped with a Kinetex core–shell C18 column (50 × 2.1 mm, 1.7 μm) using 0.1% (v/v) aqueous formic acid and acetonitrile containing 0.1% (v/v) formic acid as a mobile phase by gradient elution at a flow rate of 0.3 mL/min. Quantitation of this analysis was performed on a triple quadrupole mass spectrometer employing electrospray ionization technique operating in multiple reaction monitoring positive ion mode. Mass transitions were m/z 323.3 → 83.1 for mequitazine and 281.3 → 86.3 for imipramine as internal standard. Liquid–liquid extraction with ethyl acetate and protein precipitation with methanol were used for sample extraction. Chromatograms showed that the method had high resolution, sensitivity and selectivity without interference from plasma constituents. Calibration curves for mequitazine in rat plasma and urine were 0.02–200 ng/mL, showing excellent linearity with correlation coefficients (r2) >0.99. Both intra‐ and inter‐day precisions (CV%) were within 4.08% for rat plasma and urine. The accuracies were 99.58–102.03%. The developed analytical method satisfied the criteria of international guidance. It could be successfully applied to pharmacokinetic studies of mequitazine after oral and intravenous administration to rats.  相似文献   

3.
Crizotinib is a small molecule inhibitor of anaplastic lymphoma kinase (ALK) and can be used to treat ALK‐positive nonsmall‐cell lung cancer. A rapid and simple high‐performance liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the quantification of crizotinib in rat plasma using a chemical synthetic compound buspirone as the internal standard (IS). The plasma samples were pretreated by a simple protein precipitation with methanol–acetonitrile (1:1, v/v). Chromatographic separation was successfully achieved on an Agilent Zorbax XDB C18 column (2.1 × 50 mm, 3.5 µm). The gradient elution system was composed of 0.1% formic acid aqueous solution and 0.1% formic acid in methanol solution. The flow rate was set at 0.50 mL/min. The multiple reaction monitoring was based on the transitions of m/z = 450.3 → 177.1 for crizotinib and 386.2 → 122.2 for buspirone (IS). The assay was successfully validated to demonstrate the selectivity, matrix effect, linearity, lower limit of quantification, accuracy, precision, recovery and stability according to the international guidelines. The lower limit of quantification was 1.00 ng/mL in 50 μL of rat plasma. This LC‐MS/MS assay was successfully applied to the quantification and pharmacokinetic study of crizotinib in rats after intravenous and oral administration of crizotinib. The oral absolute bioavailability of crizotinib in rats was 68.6 ± 9.63%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
A simple, rapid and sensitive liquid chromatography–tandem mass spectroscopy (LC–MS/MS) method was developed and validated for the determination of ethyl gallate, a pharmacologically active constituent isolated from Lagerstroemia speciosa (Linn.) Pers. This method was used to examine the pharmacokinetics of ethyl gallate and its major metabolite gallic acid in rat plasma using propyl gallate as an internal standard. After precipitation of the plasma proteins with acetonitrile, the analytes were separated on a Zorbax SB‐C18 column (3.5 μm, 2.1 × 50 mm) with an isocratic mobile phase consisted of methanol–acetonitrile–10 mM ammonium acetate (10 : 25 : 65, v/v/v) containing 0.1% formic acid at a flow rate of 0.25 mL/min. The Agilent G6410A triple quadrupole LC/MS system was operated under the multiple‐reaction monitoring mode using the electrospray ionization technique in negative mode. The lower limits of quantification of gallic acid and ethyl gallate of the method were 0.5 and 1.0 ng/mL. The intra‐day and inter‐day accuracy and precision of the assay were less than 8.0%. This method has been applied successfully to a pharmacokinetic study involving the intragastric administration of ethyl gallate to rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
A rapid, selective, and sensitive liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous determination of unbound sunitinib and its active metabolite N‐desethyl sunitinib in plasma. Plasma and post‐dialysis buffer samples were extracted using a liquid–liquid extraction procedure with acetonitrile–n‐butylchloride (1:4, v/v). Chromatographic separation was achieved on a Waters X‐Terra® MS RP18 column with a mobile phase consisting of acetonitrile and water (60:40, v/v) containing formic acid (0.1%, v/v) using an isocratic run, at a flow‐rate of 0.2 mL/min. Analytes were detected by electrospray tandem mass spectrometry in the selective reaction monitoring mode. Linear calibration curves were generated over the ranges 0.1–100 and 0.02–5 ng/mL for sunitinib and 0.2–200 and 0.04–10 ng/mL for N‐desethyl sunitinib in plasma and in phosphate‐buffered solution, respectively. The values for both within‐day and between‐day precision and accuracy were well within the generally accepted criteria for analytical methods. The analytical range was sufficient to determine the unbound and total concentrations of both analytes. The method was applied for measurement unbound concentrations in addition to total concentrations of sunitinib and its metabolite in plasma of a cancer patient receiving 50 mg daily dose. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
A sensitive and selective liquid chromatography–tandem mass spectrometry method for the determination of piracetam in rat plasma was developed and validated over the concentration range of 0.1–20 µg/mL. After addition of oxiracetam as internal standard, a simplified protein precipitation with trichloroacetic acid (5%) was employed for the sample preparation. Chromatographic separation was performed by a Zorbax SB‐Aq column (150 × 2.1 mm, 3.5 µm). The mobile phase was acetonitrile–1% formic acid in water (10:90 v/v) delivered at a flow rate of 0.3 mL/min. The MS data acquisition was accomplished in multiple reaction monitoring mode with a positive electrospray ionization interface. The lower limit of quantification was 0.1 µg/mL. For inter‐day and intra‐day tests, the precision (RSD) for the entire validation was less than 9%, and the accuracy was within the 94.6–103.2% range. The developed method was successfully applied to pharmacokinetic studies of piracetam in rats following single oral administration dose of 50 mg/kg. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
A simple, rapid and high sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method for the determination of neostigmine in small‐volume beagle dog plasma was developed to assess the plasma pharmacokinetics of neostigmine. After protein precipitation in a Sirocco 96‐well filtration plate, the filtrate was directly injected into the LC‐MS/MS system. The analytes were separated on a Hanbon Hedera CN column (100 × 4.6 mm, 5 µm) with a mobile phase composed of methanol–water (60:40, v/v) and the water containing 0.01% formic acid at a flow rate of 0.6mL/min, with a split ratio of 1:1 flowing 300 μL into the mass spectrometer. The run time was 3 min. Detection was accomplished by electrospray ionization source in multiple reactions monitoring mode with the precursor‐to‐product ion transitions m/z 223.0 → 72.0 and 306.0 → 140.0 for neostigmine and anisodamine (internal standard), respectively. The method was sensitive with a lower limit of quantitation of 0.1 ng/mL, and good linearity in the range 0.1–100ng/mL for neostigmine (r ≥ 0.998). All the validation data, such as accuracy, intra‐run and inter‐run precision, were within the required limits. The method was successfully applied to pharmacokinetic study of neostigmine methylsulfate injection in beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
A sensitive, fast and specific method for the quantitation of pinocembrin in human plasma based on high‐performance liquid chromatography–tandem mass spectrometry (LC/MS/MS) was developed and validated. Clonazepam was used as the internal standard (IS). After solid‐phase extraction of 500 μL plasma, pinocembrin and the IS were separated on a Luna C8 column using the mobile phase composed of acetonitrile–0.3 mm ammonium acetate solution (65:35, v/v) at a flow rate of 0.25 mL/min in isocratic mode. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via an electrospray ionization source in negative mode by AB SCIEX Qtrap 5500. The assay was linear from 1 to 400 ng/mL, with within‐ and between‐run accuracy (relative error) from ?1.82 to 0.54%, and within‐ and between‐run precision (CV) below 5.25%. The recovery was above 88% for the analyte at 1, 50 and 300 ng/mL. This analytical method was successful for the determination of pinocembrin in human plasma and applied to a pharmacokinetic study of pinocembrin injection in healthy volunteers after intravenous drip administration. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
A rapid, simple, sensitive and selective LC‐MS/MS method has been developed and validated for quantification of the atorvastatin (AT) and niacin (NA) in 250 μL human plasma. The analytical procedure involves a liquid–liquid extraction method using nevirapine as an internal standard (IS). The chromatographic separation was achieved on a Hypurity Advance (4.6 × 50 mm, 5 µm) column using a mobile phase consisting of 0.1% formic acid buffer–acetonitrile (20:80, v/v) at flow rate of 0.8 mL/min. The API‐4000 LC‐MS/MS was operated in the multiple‐reaction monitoring mode using electrospray ionization. The total run time of analysis was 3 min and elution of AT, NA and IS occurred at 1.06, 1.84 and 0.92 min, respectively. A detailed validation of the method was performed as per the US Food and Drug Administration guidelines and the standard curves found to be linear in the range of 0.10–30.0 ng/mL for AT and 20.2–6026 ng/mL for NA, with a coefficient of correlation of ≥0.99 for both the compounds. AT and NA were found to be stable in a battery of stability studies, viz. bench‐top, autosampler, re‐injection, wet‐extract and repeated freeze–thaw cycles. The developed assay method was successfully applied to a pharmacokinetic study in humans. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
A facile, fast and specific method based on liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the simultaneous quantitation of paracetamol, chlorzoxazone and aceclofenac in human plasma was developed and validated. Sample preparation was achieved by liquid–liquid extraction. The analysis was performed on a reversed‐phase C18 HPLC column (5 μm, 4.6 × 50 mm) using acetonitrile–10 mM ammonium formate pH 3.0 (65:35, v/v) as the mobile phase where atrovastatin was used as an internal standard. A very small injection volume (3 μL) was applied and the run time was 2.0 min. The detection was carried out by electrospray positive and negative ionization mass spectrometry in the multiple‐reaction monitoring mode. The developed method was capable of determining the analytes over the concentration ranges of 0.03–30.0, 0.015–15.00 and 0.15–15.00 μg/mL for paracetamol, chlorzoxazone and aceclofenac, respectively. Intraday and interday precisions (as coefficient of variation) were found to be ≤12.3% with an accuracy (as relative error) of ±5.0%. The method was successfully applied to a pharmacokinetic study of the three analytes after being orally administered to six healthy volunteers.  相似文献   

11.
A sensitive and specific LC–MS/MS assay for determination of β ‐eudesmol in rat plasma was developed and validated. After liquid–liquid extraction with ethyl ether , the analyte and IS were separated on a Capcell Pak C18 column (50 × 2.0 mm, 5 μm) by isocratic elution with acetonitrile—water–formic acid (77.5:22.5:0.1, v /v/v) as the mobile phase at a flow rate of 0.4 mL/min. An ESI source was applied and operated in positive ion mode; a selected reaction monitoring scan was used for quantification by monitoring the precursor–product ion transitions of m/z 245.1 → 163.1 for β ‐eudesmol and m/z 273.4 → 81.2 for IS. Good linearity was observed in the concentration range of 3–900 ng/mL for β ‐eudesmol in rat plasma. Intra‐ and inter‐day precision and accuracy were both within ±14.3%. This method was applied for pharmacokinetic studies after intravenous bolus of 2.0 mg/kg or intragastric administration of 50 mg/kg β ‐eudesmol in rats.  相似文献   

12.
A simple, fast and reliable high‐performance liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous quantification and pharmacokinetic study of three flavonoids (liquiritigenin, isoliquiritigenin and formononetin) and three anthraquinones (emodin, rhein and aloe‐emodin), which are the bioactive ingredients of Wei‐Chang‐Shu tablet found in rat plasma. After extraction by liquid–liquid extraction with ethyl acetate, chromatographic separation was achieved on an Agilent Zorbax SB‐C18 column (4.6 × 150 mm, 5 μm) at a flow rate of 1 mL/min by gradient elution using 0.1% aqueous acetic acid and acetonitrile. The detection was performed using a triple quadrupole mass spectrometer equipped with electrospray ionization source in the negative ionization and selected reaction monitoring mode. Method validation was performed in terms of specificity, carryover, linearity (r > 0.99), intra−/inter‐day precision (1.0–10.1%), accuracy (relative error, <7.6%), stability (0.6–13.2%), extract recovery (74.9–91.9%) and matrix effect (89.1–109%). The lower limits of quantification of the six analytes varied from 0.92 to 10.4 ng/mL. The validated method was successfully applied to compare the pharmacokinetic properties of Wei‐Chang‐Shu tablet in normal rats and in rats with gastrointestinal motility disorders. The results indicated that there were obvious differences in the pharmacokinetic behavior between normal and model rats. This study will be helpful in the clinical application of Wei‐Chang‐Shu tablet.  相似文献   

13.
A rapid and sensitive liquid chromatography–tandem mass spectrometric method (LC‐MS/MS) for the determination of bromotetrandrine in rat plasma has been developed and applied to pharmacokinetic study in Sprague–Dawley (SD) rats after a single oral administration. Sample preparation involves a liquid–liquid extraction with n‐hexane–dichlormethane (65:35, containing 1% 2‐propanol isopropyl alcohol, v/v). Bromotetrandrine and brodimoprim (internal standard, IS) were well separated by LC with a Dikma C18 column using methanol–ammonium formate aqueous solution (20 mm ) containing 0.5% formic acid (60:40, v/v) as mobile phase. Detection was performed on a triple quadrupole mass spectrometer in multiple reaction monitoring mode. The ionization was optimized using ESI(+) and selectivity was achieved using MS/MS analysis, m/z 703.0 → 461.0 and m/z 339.0 → 281.0 for bromotetrandrine and IS, respectively. The present method exhibited good linearity over the concentration range of 20–5000 ng/mL for bromotetrandrine in rat plasma with a lower limit of quantification of 20 ng/mL. The intra‐ and inter‐day precisions were 2.8–7.5% and 3.2–8.1%, and the intra‐ and inter‐day accuracy ranged from ?4.8 to 8.2% and ?5.6 to 6.2%, respectively. The method was successfully applied to a pharmacokinetic study after a single oral administration to SD rats with bromotetrandrine of 50 mg/kg. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Taraxasterol, a pentacyclic triterpene from Taraxacum officinale, is one of the main active constituents of the herb. This study developed and validated a highly selective and sensitive liquid chromatography/tandem mass spectrometry for the determination of taraxasterol in rat plasma over the range of 9.0–5000 ng/mL. Chromatographic separation was achieved on a C18 (4.6 × 50 mm, 5.0 µm) column with methanol–isopropanol–water–formic acid (80:10:10:0.1, v/v/v/v) as mobile phase with an isocratic elution. The flow rate was 0.7 mL/min. After adding cucurbitacin IIa as an internal standard (IS), liquid–liquid extraction was used for sample preparation using ethyl acetate. The atmospheric pressure chemical ionization source was applied and operated in positive ion mode. Selected reaction monitoring mode was used for the quantification of transition ions m/z 409.4 → 137.1 for taraxasterol and m/z 503.4 → 113.1 for IS. The mean recoveries of taraxasterol in rat plasma ranged from 85.3 to 87.2%. The matrix effects for taraxasterol were between 98.5 and 104.0%. Intra‐ and inter‐day precision were both <11.8%, and the accuracy of the method ranged from ?7.0 to 12.9%. The method was successfully applied to a pharmacokinetic study of taraxasterol after oral administration of 7.75, 15.5 and 31.0 mg/kg in rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
A simple, sensitive and rapid liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the determination of calceorioside B (CLB) in rat plasma. Detection was performed on a Thermo Scientific Hypersil Gold chromatography column using isocratic elution with a mobile phase of methanol–5 m m ammonium acetate–formic acid (70:30:0.1, v/v/v). Mass spectrometry was performed in selection reaction monitoring mode using a positive electrospray ionization interface. Good linearity was found for CLB in plasma in the linear range of 1.00–500 ng/mL (r > 0.9960). The validated method was successfully applied to the pharmacokinetic study of CLB in rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
A rapid, sensitive and specific liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated for the quantification of heteroclitin D in rat plasma after using gambogic acid as internal standard (IS). Chromatographic separation was done on a Thermo Hypersil GOLD column (30 × 2.1 mm, 3 µm) using a mobile phase consisting of methanol–water–formic acid (80:20:0.1, v/v/v). The mass spectrometer worked with positive electrospray ionization in multiple reaction monitoring mode, using target ions at [M + H]+ m/z 483.3 for heteroclitin D and [M + H]+ m/z 629.3 for the IS. The standard curve was linear (R2 ≥0.995) over the concentration range 9.98–2080 ng/mL and had good back‐calculated accuracy and precision. The intra‐ and interday precision and accuracy determined on three quality control samples (29.94, 166.4 and 1872 ng/mL) were ≤12.8 and –8.9–3.6%, respectively. The extraction recovery was ≥88.2% and the lower limit of quantification was 9.98 ng/mL. The method was successfully applied to evaluate pharmacokinetics of heteroclitin D in Sprague–Dawley rats following a single intravenous bolus injection of 2.0 mg/kg heteroclitin. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
A fast and accurate liquid chromatography/tandem mass spectrometric (LC‐MS/MS) assay was first developed and validated for the determination of deferiprone in human plasma. The analytes were extracted with acetonitrile from only 50 μL aliquots of human plasma to achieve the protein precipitation. After extraction, chromatographic separation of analytes in human plasma was performed using a Synergi Fusion‐RP 80A column at 30 °C. The mobile phase consisted of methanol and 0.2% formic acid containing 0.2 mM EDTA (60:40, v/v). The flow rate of the mobile phase was 0.8 mL/min. The total run time for each sample analysis was 4 min. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the precursor‐to‐parent ion transitions m/z 140.1 → 53.1 for deferiprone and m/z 143.1 → 98.1 for internal standard. A linear range was established from 0.1 to 20 µg/mL. The limit of detection was determined as 0.05 µg/mL. The validated method was estimated for linearity, recovery, stability, precision and accuracy. Intraday and interday precisions were 4.3–5.5 and 4.6–7.3%, respectively. The recovery of deferiprone was in the range of 80.1–86.8%. The method was successfully applied to a pharmacokinetic study of deferiprone in six thalassemia patients. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
A liquid chromatography–tandem mass spectrometric (LC/MS/MS) method was developed for the determination of an atypical antipsychotic drug, lurasidone, in rat plasma. The method involves the addition of acetonitrile and ziprasidone (internal standard) solution to plasma samples, followed by centrifugation. An aliquot of the supernatant was diluted with water and directly injected into the LC/MS/MS system. The separations were performed on a column packed with octadecylsilica (5 μm, 2.0 × 50 mm) with 0.1% formic acid and 0.1% formic acid in acetonitrile as mobile phase and the detection was performed using tandem mass spectrometry by multiple‐reaction monitoring via an electrospray ionization source. The standard curve was linear (r = 0.9982) over the concentration range 0.002–1 μg/mL. The intra‐ and inter‐assay precisions were 1.7 and 8.6%, respectively. The accuracy range was from 90.3 to 101.8%. The lower limit of quantification was 2.0 ng/mL using 50 μL of rat plasma sample. The developed analytical method was successfully applied to the pharmacokinetic study of lurasidone in rats. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
In this study, a rapid and reliable ultra‐fast liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous determination of eight active ingredients, including astragaloside IV, ononin, tanshinol, protocatechualdehyde, protocatechuic acid, salvianolic acid D, rosmarinic acid and ginsenoside Rg1, in rat plasma. The plasma samples were pretreated by protein precipitation with acetonitrile. Chromatographic separation was performed on a Waters Acquity UPLC® BEH C18 column (1.7 μm particles, 2.1 × 100 mm). The mobile phase consisted of 0.1% aqueous formic acid (A)–acetonitrile with 0.1% formic acid (B) at a flow rate of 0.4 mL/min. Quantification was performed on a triple quadruple tandem mass spectrometry with electrospray ionization by multiple reaction monitoring both in the negative and in the positive ion mode. The lower limit of quantification of tanshinol was 2.0 ng/mL and the others were 5.0 ng/mL. The extraction recoveries, matrix effects, intra‐ and inter‐day precision and accuracy of eight tested components were all within acceptable limits. The validated method was successfully applied to the pharmacokinetic study of the eight active constituents after intragastric administration of three doses (1.0, 3.0, 6.0 g/kg body weight) of Qishen Yiqi Dripping Pills to rats.  相似文献   

20.
A rapid and sensitive liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS) method to determine clonidine in human plasma was developed and fully validated. Sample preparation was involved an one‐step extraction with diethyl ether. Donepezil was employed as the internal standard (IS). Chromatographic separation was performed on a Hypersil BDS C18 column (i.d. 2.1 × 50 mm, particle size 3μm) with a mobile phase of methanol–water (containing 0.1% formic acid; 60:40, v/v) at a flow rate of 200 μL/min. The peaks were detected by mass spectrometry using the electrospray ion source in selected reaction monitoring mode. The extraction recovery was 72.53–85.25%. The method was found to be linear in a concentration range of 0.02–6.00 ng/mL and the lower limit of quantification was 0.02 ng/mL. The within‐ and between‐batch precisions at three concentrations were 4.33–16.47 and 7.24–17.24% with accuracies of ?2.47–10.91 and 1.86–10.19%, respectively. This validated method was successfully used for a bioequivalence study of two clonidine transdermal patches on healthy volunteers. The results suggested that the test formulation of clonidine patch met the regulatory criterion for bioequivalence to the reference formulation, but a larger sample size should be needed for the estimation of bioequivalence. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号