首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The abundant production of methyl tert‐butyl ether (MTBE) and its widespread use have led to an increase in the potential for human exposure. This work described a simple, fast, sensitive, reliable and low‐cost method for the simultaneous measurement of MTBE and its metabolite, tert‐butyl alcohol (TBA) in human serum by headspace solid‐phase microextraction gas chromatography–mass spectrometry. Extraction conditions were optimized and 40 °C, 10 min, 250 rpm and 0.3 g NaCl for a 1 mL sample were the optimal conditions. This method showed good analytical performance in terms of sensitivity with limits of detection in serum (1 mL) of 0.03 µg/L for MTBE and 0.05 µg/L for TBA, accuracy (mean recovery values) from 75.8% to 85.8%, precision (relative standard deviations) <10% and sample stability (biodegradation) <10% after 28 days. A verification experiment proved the reproducibility and stability of this method as well. Finally the method was used to detect 212 specimens, and the internal dose levels for MTBE in human serum were presented in China. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
A headspace solid‐phase microextraction (HS‐SPME) method coupled to GC‐MS was developed in order to determine trace levels of tetramethyltin (TeMT) and inorganic tin (iSn) after ethylation to tetraethyltin (TeET) in various matrices. The derivatization of iSn and the extraction of both TeMT and iSn as TeET were performed in one step. Sodium tetraethylborate (NaBEt4) was used as derivatization agent and the volatile derivatives were absorbed on a PDMS‐coated fused silica fiber. The conditions for the HS‐SPME procedure were optimized in order to gain in repeatability and sensitivity. Several critical parameters of GC‐MS were also studied. The detection of TeMT and iSn as TeET peaks was performed by the SIM mode. The precision of the proposed method is satisfactory providing RSD values below 10% for both tin species and good linearity up to 10 μg/L. The developed method was successfully applied to the determination of tin species in several samples like canned fish, fish tissues, aquatic plants, canned mineral water and sea water. The proposed HS‐SPME‐GC‐MS method was proved suitable to monitor the concentration levels of toxic tin compounds in environmental and biological samples.  相似文献   

3.
A number of fatty acid ethyl esters (FAEEs) have recently been detected in meconium samples. Several of these FAEEs have been evaluated as possible biomarkers for in utero ethanol exposure. In the present study, a method was optimized and validated for the simultaneous determination of eight FAEEs (ethyl laurate, ethyl myristate, ethyl palmitate, ethyl palmitoleate, ethyl stearate, ethyl oleate, ethyl linoleate and ethyl arachidonate) in meconium samples. FAEEs were extracted by headspace solid‐phase microextraction. Analyte detection and quantification were carried out using GC‐MS operated in chemical ionization mode. The corresponding D5‐ethyl esters were synthesized and used as internal standards. The LOQ and LOD for each analyte were <150 and <100 ng/g, respectively. The method showed good linearity (r2>0.98) in the concentration range studied (LOQ – 2000 ng/g). The intra‐ and interday imprecision, given by the RSD of the method, was lower than 15% for all FAEEs studied. The validated method was applied to 63 authentic specimens. FAEEs could be detected in alcohol‐exposed newborns (>600 ng/g cumulative concentration). Interestingly, FAEEs could also be detected in some non‐exposed newborns, although the concentrations were much lower than those measured in exposed cases.  相似文献   

4.
A recent guideline recommends therapeutic drug monitoring for risperidone, paliperidone and olanzapine, which are frequently used second‐generation antipsychotics. We developed a simple high‐performance liquid chromatography–tandem mass spectrometry coupled with an online solid‐phase extraction method that can be used to measure risperidone, paliperidone and olanzapine using small (40 μL) samples. The analytes were extracted from serum samples automatically pre‐concentrated and purified by C8 (5 μm, 2.1 × 30 mm) solid‐phase extraction cartridges, then chromatographed on an Xbidge™ C18 column (3.5 μm, 100 × 2.1 mm) thermostatted at 30°C with a mobile phase consisting of 70% acetonitrile and 30% ammonium hydroxide 1% solution at an isocratic flow rate of 0.3 mL/min, and detected with tandem mass spectrometry. The assay was validated in the concentration range from 2.5 to 160 ng/mL. Intra‐ and inter‐day precision for all analytes was between 1.1 and 8.2%; method accuracy was between 6.6 and 7.6%. The risperidone and paliperidone assay was compared with a high‐performance liquid chromatography‐ultraviolet assay currently used in our hospital for risperidone and paliperidone therapeutic drug monitoring, and the results of weighted Deming regression analysis showed good agreement. For the olanzapine assay, we compared 20 samples in separate re‐assays on different days; all the relative errors were within the 20% recommended limit.  相似文献   

5.
An efficient and sensitive multiresidue method has been developed for quantification and confirmation of 25 phenyl acetanilide pesticides in a wide variety of food commodities including maize, spinach, mushroom, apple, soybean, chestnut, tea, beef, cattle liver, chicken, fish, and milk. Analytes were extracted with acetone–n‐hexane (1:2, v/v) followed by cleanup using SPE. Several types of adsorbents were evaluated. Neutral aluminum and graphitized carbon black cartridge showed good cleanup efficiency. The extract was determined by GC‐MS in the selected ion monitoring mode using one target and two qualitative ions for each analyte. The limits of detection were 0.01 mg/kg for all analytes. The average recoveries ranged from 66.9 to 110.6% (mean 88.8%) and RSDs were in the range 2.0–19% (mean 10.5%) across three fortification levels. The proposed method was successfully applied to real samples in routine analysis and a satisfactory result was obtained.  相似文献   

6.
An analytical method was established for the simultaneous determination of seven nitrogen‐containing phenyl ethers (2‐anisidine, 3‐anisidine, 4‐anisidine, 2‐nitroanisole, 3‐nitroanisole, 4‐nitroanisole, and 3,3'‐dimethoxybenzidine) in cosmetics by gas chromatography with mass spectrometry in this work. The samples were extracted with ethyl acetate and purified with primary secondary amine during the dispersed solid‐phase extraction. The analytes were separated by a DB‐17MS column and detected in the electron ionization mode of mass spectrometry in the selected ions monitoring mode. The extraction solvent, purification adsorbents, and chromatographic column behavior were optimized. The results indicated that the seven analytes show good linear relationship (R 2 > 0.9965) in the concentrations of 5.0–5000 μg/L. The quantitation limits of the method ranged from 19.0 to 84.8 μg/kg. The recovery rates of seven analytes were in the range of 72.6–114% with the relative standard deviations of 1.1–7.5%. Real sample analyses showed that this accurate and precise method could be appropriate for simultaneous determination of seven nitrogen‐containing phenyl ethers in cosmetics.  相似文献   

7.
A liquid chromatography–tandem mass spectrometric method for the simultaneous determination of 75 abuse drugs and metabolites, including 19 benzodiazepines, 19 amphetamines, two opiates, eight opioids, cocaine, lysergic acid diethylamide, zolpidem, three piperazines and 21 metabolites in human hair samples, was developed and validated. Ten‐milligram hair samples were decontaminated, pulverized using a ball mill, extracted with 1 mL of methanol spiked with 28 deuterated internal standards in an ultrasonic bath for 60 min at 50°C, and purified with Q‐sep dispersive solid‐phase extraction tubes. The purified extracts were evaporated to dryness and the residue was dissolved in 0.1 mL of 10% methanol. The 75 analytes were analyzed on an Acquity HSS T3 column using gradient elution of methanol and 0.1% formic acid and quantified in multiple reaction monitoring mode with positive electrospray ionization. Calibration curves were linear (r ≥ 0.9951) from the lower limit of quantitation (2–200 pg/mg depending on the drug) to 2000 pg/mg. The coefficients of variation and accuracy for intra‐ and inter‐assay analysis at three QC levels were 4.3–12.9% and 89.2–109.1%, respectively. The overall mean recovery ranged from 87.1 to 105.3%. This method was successfully applied to the analysis of 11 forensic hair samples obtained from drug abusers.  相似文献   

8.
An ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction was first employed to determine the volatile components in tobacco samples. The method combined the advantages of ultrasound, microwave, and headspace solid‐phase microextraction. The extraction, separation, and enrichment were performed in a single step, which could greatly simplify the operation and reduce the whole pretreatment time. In the developed method, several experimental parameters, such as fiber type, ultrasound power, and irradiation time, were optimized to improve sampling efficiency. Under the optimal conditions, there were 37, 36, 34, and 36 components identified in tobacco from Guizhou, Hunan, Yunnan, and Zimbabwe, respectively, including esters, heterocycles, alkanes, ketones, terpenoids, acids, phenols, and alcohols. The compound types were roughly the same while the contents were varied from different origins due to the disparity of their growing conditions, such as soil, water, and climate. In addition, the ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction method was compared with the microwave‐assisted extraction coupled to headspace solid‐phase microextraction and headspace solid‐phase microextraction methods. More types of volatile components were obtained by using the ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction method, moreover, the contents were high. The results indicated that the ultrasound‐microwave synergistic extraction coupled to headspace solid‐phase microextraction technique was a simple, time‐saving and highly efficient approach, which was especially suitable for analysis of the volatile components in tobacco.  相似文献   

9.
A new facile magnetic micro‐solid‐phase extraction coupled to gas chromatography and mass spectrometry detection was developed for the extraction and determination of selected antidepressant drugs in biological fluids using magnetite‐MCM‐41 as adsorbent. The synthesized sorbent was characterized by several spectroscopic techniques. The maximum extraction efficiency for extraction of 500 μg/L antidepressant drugs from aqueous solution was obtained with 15 mg of magnetite‐MCM‐41 at pH 12. The analyte was desorbed using 100 μL of acetonitrile prior to gas chromatography determination. This method was rapid in which the adsorption procedure was completed in 60 s. Under the optimized conditions using 15 mL of antidepressant drugs sample, the calibration curve showed good linearity in the range of 0.05–500 μg/L (r 2 = 0.996–0.999). Good limits of detection (0.008–0.010 μg/L) were obtained for the analytes with good relative standard deviations of <8.0% (n  = 5) for the determination of 0.1, 5.0, and 500.0 μg/L of antidepressant drugs. This method was successfully applied to the determination of amitriptyline and chlorpromazine in plasma and urine samples. The recoveries of spiked plasma and urine samples were in the range of 86.1–115.4%. Results indicate that magnetite micro‐solid‐phase extraction with gas chromatography and mass spectrometry is a convenient, fast, and economical method for the extraction and determination of amitriptyline and chlorpromazine in biological samples.  相似文献   

10.
A fast and simple screening procedure using solid‐phase microextraction and gas chromatography‐mass spectrometry (SPME‐GC‐MS) in full‐scan mode for the determination of volatile organic compounds (VOC) is presented. The development of a fast and simple screening technique for the simultaneous determination of various volatiles is of great importance, because of their widespread use, frequent occurrence in forensic toxicological questions and the fact that there is often no hint on involved substances at the crime scene. To simulate a screening procedure, eight VOC with different chemical characteristics were chosen (isoflurane, halothane, hexane, chloroform, benzene, isooctane, toluene and xylene). To achieve maximum sensitivity, variables that influence the SPME process, such as type of fiber, extraction and desorption temperature and time, agitation and additives were optimized by preliminary studies and by means of a central composite design. The limits of detection and recoveries ranged from 2.9 µg/l (xylene) to 37.1 µg/l (isoflurane) and 7.9% (chloroform) to 61.5% (benzene), respectively. This procedure can be used to answer various forensic and toxicological questions. The short time taken for the whole analytical procedure may make its eventual adoption for routine analysis attractive. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
A novel polystyrene/pyridine composite nanofiber was synthesized and utilized as the sorbent material for the solid‐phase extraction of bisphenol A and five common phthalate esters in milk. The method of extraction integrated extraction and preconcentration of target analytes into a single step. Bisphenol A and five common phthalate esters were selected as target compounds for the development and evaluation of the method. The effects of operating parameters for nanofiber‐based solid‐phase extraction, such as selection and amount of sorbent, the volume fraction of perchlorate (precipitate protein), desorption solvent, volume of desorption solvent, and effect of salt addition were optimized. Under optimal conditions, higher extraction recoveries (89.6–118.0%) of the six compounds in milk spiked at three levels were obtained, and the satisfied relative standard deviation were ranged from 0.6 to 10.9%. The detection limits and quantification limits of the method ranged from 0.01 to 0.06 μg/L and 0.05 to 0.53 μg/L, respectively. Matrix effects were also verified and well controlled in the range of 91.3–109.3%. The new method gave better performance metrics than Chinese standard method and other published methods. Thus, the proposed method may be applied to the analysis of the phthalate esters and bisphenol A in complex matrixes.  相似文献   

12.
A headspace solid‐phase micro‐extraction (HS‐SPME) method was employed in order to study the effect of storage conditions of human urine samples spiked with tributyltin (TBT) using gas chromatography and mass spectrometry. To render the analyte more volatile, the derivatization (ethylation) was made in situ by sodium tetraethylborate (NaBEt4), which was added directly to dilute unpreserved urine samples and in buffers of similar acidity. The stability of TBT in human urine matrix was compared with the stability of TBT in buffer solutions of similar pH value. Critical parameters of storage conditions such as temperature and time, which affect the stability of TBT in this kind of matrix, were examined extensively. The tests showed that the stability of TBT remains practically satisfactory for a maximum of 2 days of storage either at +4 or 20°C. Greater variations were observed in the concentration of TBT in human urine samples at +4°C and lower ones at ?20°C over a month's storage. The freeze–thaw cycles have negative effect on the stability and should be kept to a minimum. The results from spiked urine samples are also discussed in comparison to those acquired from buffer solutions of equal TBT concentration. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
Cinnamaldehyde (CA), an active ingredient isolated from the traditional Chinese medicine Cortex Cinnamomi, has a wide range of bioactivities. To clarify the distribution characteristics of CA, a selective and sensitive method utilizing gas chromatography–mass spetrometry was initially developed for simultaneously determining the concentration of CA and its metabolite cinnamyl alcohol in rat tissues. Selected ion masses of m/z 131, 105 and 92 were chosen, and separation of the analytes was performed on a DB‐5 ms (30 m × 0.25 mm, 0.25 µm, thickness) capillary column by gas chromatography–mass spectrometry. The calibration curves demonstrated good linearity and reproducibility over the range of 20–2000 and 20–4000 ng/mL for various tissue samples. Recoveries ranged from 86.8 to 107.5%, while intra‐ and interday relative standard deviations were all <11.3%. The analysis method was successfully applied in tissue distribution studies for CA and cinnamyl alcohol. As CA and cinnamyl alcohol may inter‐convert to one another, simultaneous determination of both analytes provides a comparative and accurate data for tissue study. The concentrations of CA and cinnamyl alcohol remaining in spleen were the highest among the main organs, including heart, liver, spleen, lung, kidney and brain. In addition, there was no long‐term accumulation of CA in rat tissues. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
The chromatographic separation of several isomeric anilines is a challenging issue. Herein, a simple method for the simultaneous determination of four groups of isomeric primary aromatic amines, including chloroanilines, methylanilines, methoxylanilines, and dimethylanilines, was presented. In this method, all of the 15 primary aromatic amines were easily transformed into the corresponding imine derivative by treatment with benzaldehyde under mild conditions. The formed isomeric imine derivatives were completely separated on a commercial capillary gas chromatography column. The effects of several derivatization parameters were investigated and optimized. Linearity in the optimized method ranged from 0.050 to 50 μg/mL with the squared correlation coefficients (R2) between 0.9981 and 0.9999. Reasonable reproducibility was obtained, with the intraday relative standard deviation (= 5) ranging from 0.89 to 4.57% and interday relative standard deviation ranging from 2.26 to 7.69% at the concentration of 5.0 μg/mL. The developed method has been successfully applied to determine these isomeric aromatic amines in real samples.  相似文献   

15.
A gas chromatography–mass spectrometry method was developed and validated for the simultaneous automated solid‐phase extraction and quantification of cotinine and trans‐3‐hydroxycotinine in human urine. Good linearity was observed over the concentration ranges studied (R2 > 0.99). The limit of quantification was 10 ng/mL for both analytes. The limits of detection were 0.06 ng/mL for cotinine (COT) and 0.02 ng/mL for trans‐3‐hydroxycotinine (OH‐COT). Accuracy for COT ranged from 0.98 to 5.28% and the precision ranged from 1.24 to 8.78%. Accuracy for OH‐COT ranged from ?2.66 to 3.72% and the precision ranged from 3.15 to 7.07%. Mean recoveries for cotinine and trans‐3‐hydroxycotinine ranged from 77.7 to 89.1%, and from 75.4 to 90.2%, respectively. This analytical method for the simultaneous measurement of cotinine and trans‐3‐hydroxycotinine in urine will be used to monitor tobacco smoking in pregnant women and will permit the usefulness of trans‐3‐hydroxycotinine as a specific biomarker of tobacco exposure to be determined. © 2014 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd.  相似文献   

16.
A liquid chromatography–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of GDC‐0152 in human plasma to support clinical development. The method consisted of a solid‐phase extraction for sample preparation and LC‐MS/MS analysis in the positive ion mode using TurboIonSprayTM for analysis. d7‐GDC‐0152 was used as the internal standard. A linear regression (weighted 1/concentration2) was used to fit calibration curves over the concentration range of 0.02–10.0 ng/mL for GDC‐0152. There were no endogenous interference components in the blank human plasma tested. The accuracy at the lower limit of quantitation was 99.3% with a precision (%CV) of 13.9%. For quality control samples at 0.0600, 2.00 and 8.00 ng/mL, the between‐run %CV was ≤8.64. Between‐run percentage accuracy ranged from 98.2 to 99.6%. GDC‐0152 was stable in human plasma for 363 days at ?20°C and for 659 days at ?70°C storage. GDC‐0152 was stable in human plasma at room temperature for up to 25 h and through three freeze–thaw cycles. In whole blood, GDC‐0152 was stable for 12 h at 4°C and at ambient temperature. This validated LC‐MS/MS method for determination of GDC‐0152 was used to support clinical studies. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
A dispersive solid‐phase extraction coupled with ultra high performance liquid chromatography with tandem mass spectrometry method was developed and validated for the simultaneous determination of T‐2 toxin, penicillic acid, fumonisins B1, B2, and B3, aflatoxins B1, B2, G1, and G2, ochratoxin A, deoxynivalenol, 3‐acetyldeoxynivalenol, 15‐acetyldeoxynivalenol, and zearalenone in chestnut samples. The method was used to analyze 136 samples obtained from Shandong province in China. The mycotoxins were extracted using a dispersive solid‐phase extraction method and cleaned using an improved quick, easy, cheap, effective, rugged, and safe approach. The mycotoxins were then detected using a triple‐quadrupole mass spectrometer. The limits of detection and quantification ranged from 0.02 to 1 and 0.1 to 2 μg/kg, respectively. The recovery rates ranged from 74.2 to 109.5%, with relative standard deviations below 15%. A total of 71 samples were contaminated with seven mycotoxins at concentrations ranging from 1.2 to 105.5 μg/kg, with a number of samples exceeding the maximum limits set in the European regulations for mycotoxins in unprocessed chestnuts.  相似文献   

18.
A two‐phase electromembrane extraction (EME) was developed and directly coupled with gas chromatography mass spectrometry (GC‐MS) analysis. The proposed method was successfully applied to the simultaneous determination of imipramine, desipramine, citalopram and sertraline. The model compounds were extracted from neutral aqueous sample solutions into the organic phase filled in the lumen of the hollow fiber. This method was accomplished with 1‐heptanol as organic phase, by means of 60 V applied voltage and with the extraction time of 15 min. Experiments reported recoveries in the range of 69–87% from 1.2 mL neutral sample solution. The compounds were quantified by GC‐MS instrument, with acceptable linearity ranging from 1 to 500 ng mL?1 (R2 in the range of 0.989 to 0.998), and repeatability (RSD) ranging between 7.5 and 11.5% (n = 5). The estimated detection limits (S/N ratio of 3:1) were less than 0.25 ng mL?1. This novel approach based on two‐phase EME brought advantages such as simplicity, low‐costing, low detection limit and fast extraction with a total analysis time less than 25 min. These experimental findings were highly interesting and demonstrated the possibility of solving ionic species in the organic phase at the presence of electrical potential.  相似文献   

19.
Here, we present a method for measuring barbiturates (butalbital, secobarbital, pentobarbital, and phenobarbital) in whole blood samples. To accomplish these measurements, analytes were extracted by means of hollow‐fiber liquid‐phase microextraction in the three‐phase mode. Hollow‐fiber pores were filled with decanol, and a solution of sodium hydroxide (pH 13) was introduced into the lumen of the fiber (acceptor phase). The fiber was submersed in the acidified blood sample, and the system was subjected to an ultrasonic bath. After a 5 min extraction, the acceptor phase was withdrawn from the fiber and dried under a nitrogen stream. The residue was reconstituted with ethyl acetate and trimethylanilinium hydroxide. An aliquot of 1.0 μL of this solution was injected into the gas chromatograph/mass spectrometer, with the derivatization reaction occurring in the hot injector port (flash methylation). The method proved to be simple and rapid, and only a small amount of organic solvent (decanol) was needed for extraction. The detection limit was 0.5 μg/mL for all the analyzed barbiturates. The calibration curves were linear over the specified range (1.0 to 10.0 μg/mL). This method was successfully applied to postmortem samples (heart blood and femoral blood) collected from three deceased persons previously exposed to barbiturates.  相似文献   

20.
In this study, an effective speed‐regulated directly suspended droplet microextraction method was developed to condense pesticide residues from teas through dispersive solid‐phase extraction prior to analysis by gas chromatography with tandem mass spectrometry. The extractant was intentionally dispersed into the sample solution in the form of globules through high‐speed agitation. This procedure increases the contact area between the binary phases and shortens the distribution equilibrium time. The fine globules reassembled by decelerating stirring speed, the extractant could be taken out for gas chromatography with tandem mass spectrometry. Recovery studies were performed under optimized extraction conditions by using matrix blanks fortified with pesticides at three concentrations (10, 50, and 100 µg/kg). Over 87% of the recoveries for the analytes in four tea matrices were acceptable given their recovery ranges of 70–120% and relative standard deviations of ≤20%. The limits of quantification of most pesticides were lower than 10 µg/kg and thus satisfied the requirements for maximum residue levels prescribed by the European Community. A total of 38 tea samples from local markets were analyzed by using the proposed method. Results showed that chlorpyrifos was the most frequently detected pesticide in teas. The method is a potential choice for the routine monitoring of pesticide residues in complex matrices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号