首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive and reliable liquid chromatography tandem mass spectrometry (LC–MS/MS) method was developed to determine cyanidin‐3‐O‐glucoside (Cy‐3G) in normal and streptozotocin‐induced diabetic rat plasma. Chromatographic separation was carried out on a Zorbax SB‐C18 (50 × 4.6 mm, 5 μm) column and mass spectrometric analysis was performed using a Thermo Finnigan TSQ Quantum Ultra triple‐quadrupole mass spectrometer coupled with an ESI source in the negative ion mode. Selected reaction monitoring mode was applied for quantification using target fragment ions m/z 447.3 → 285.2 for Cy‐3G and m/z 463.0 → 300.1 for quercetin‐3‐O‐glucoside (internal standard). The calibration curve was linear over the range 3.00–2700 ng/mL (r2 ≥ 0.99) with the lower limit of quantitation at 3.00 ng/mL. Intra‐ and inter‐day precision was <14.5% and mean accuracy was from −11.5 to 13.6%. Stability testing showed that Cy‐3G remained stable during the whole analytical procedure. After validation, the assay was successfully used to support a preclinical pharmacokinetic comparison of Cy‐3G between normal and diabetic rats. Results indicated that diabetes mellitus significantly altered the in vivo pharmacokinetic characteristics of Cy‐3G after oral administration in rats.  相似文献   

2.
A specific, sensitive and stable high‐performance liquid chromatographic–tandem mass spectrometry (LC‐MS/MS) method was developed and validated for the quantitative determination of methyl 3‐amino‐6‐methoxythieno [2,3‐b]quinoline‐2‐carboxylate (PU‐48), a novel diuretic thienoquinolin urea transporter inhibitor in rat plasma. In this method, the chromatographic separation of PU‐48 was achieved with a reversed‐phase C18 column (100 × 2.1 mm, 3 μm) at 35°C. The mobile phase consisted of acetonitrile and water with 0.05% formic acid added with a gradient elution at flow rate of 0.3 mL/min. Samples were detected with the triple‐quadrupole tandem mass spectrometer with multiple reaction monitoring mode via electrospray ionization source in positive mode. The retention time were 6.2 min for PU‐48 and 7.2 min for megestrol acetate (internal standard, IS). The monitored ion transitions were mass‐to‐charge ratio (m/z) 289.1 → 229.2 for PU‐48 and m/z 385.3 → 267.1 for the internal standard. The calibration curve for PU‐48 was linear over the concentration range of 0.1–1000 ng/mL (r2 > 0.99), and the lower limit of quantitation was 0.1 ng/mL. The precision, accuracy and stability of the method were validated adequately. The developed and validated method was successfully applied to the pharmacokinetic study of PU‐48 in rats.  相似文献   

3.
9‐Dehydro‐17‐hydro‐andrographolide (DHA) and sodium 9‐dehydro‐17‐hydro‐andrographolide‐19‐yl sulfate (DHAS) are active ingredients of xiyanping injection in clinical use. A simple, rapid and sensitive UHPLC‐ESI‐MS/MS method was developed for the determination of DHA and DHAS in rat plasma, and the pharmacokinetics of DHA and DHAS after intravenous administration of xiyanping injection was investigated. The plasma samples were treated with methanol to precipitate out protein, and the separation of DHA and DHAS was achieved on a Waters BEH C18 column with a mobile phase consisting of acetonitrile and 10 mmol/L ammonium acetate solution at a flow rate of 0.4 mL/min. DHA, DHAS and the internal standard (internal standard, IS) diethylstilbestrol were detected at negative ion mode. The precursor‐product ion pairs used in multiple reaction monitoring mode were: m/z 349.1 → 286.9 (DHA), m/z 428.9 → 96.0 (DHAS) and m/z 267.1 → 236.9 (IS). Calibration curves offered satisfactory linearity within the test range, and all correlation coefficients were >0.995. The lower limit of detection of DHA and DHAS in plasma samples were determined to be 0.1 ng/mL. The lower limit of quantitation was 0.5 ng/mL for DHA and DHAS. All the recoveries of the quality control samples were in the range of 86.0–102.4%. The ratios of matrix effect were between 89.2 and 105.1%. The method was fully validated and successfully applied to the pharmacokinetic study of DHA and DHAS in rats. The study showed that both DHA and DHAS were distributed and eliminated rapidly in rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
A simple and sensitive liquid chromatography‐tandem mass spectrometry (LC–MS/MS) method has been developed and validated for the quantitation of exemestane (Exe) and its main metabolite 17‐dihydroexemestane (DhExe) in human plasma. The analytes were extracted by protein precipitation with acetonitrile, containing stable 13C‐labelled Exe (13C3‐Exe) as internal standard, and measured by LC–MS/MS. The best chromatographic separationof the analytes from the interferences was achieved by using a Phenyl column operating under isocratic regime conditions. The total chromatographic runtime was 5.0 min and the elution of Exe and DhExe occurred at 2.5 min and 2.9 min, respectively. Quantitation was performed by employing the positive electrospray ionization (ESI) technique and multiple reaction monitoring mode (MRM). The monitored precursor to product‐ion transitions for Exe, DhExe and 13C3‐Exe internal standard were m/z 297.0 → 120.8, m/z 299.1 → 134.9 and m/z 300.0 → 123.2, respectively. The lower limit of quantitation (LLOQ) was 0.1 ng/ml for DhExe and 0.2 ng/ml for Exe. The method was linear up to 36–51 ng/ml with r2 ≥ 0.998. The intra‐ and inter‐assay precision were ≤7.7% and 5.1% for Exe and ≤8.1 and 4.9% for DhExe while deviations from nominal values were in the 1.5–13.2% and ? 9.0–5.8% ranges for Exe and DhExe, respectively. The analytical method resulted robust and suitable for pharmacokinetic monitoring of Exe and its main metabolite during adjuvant therapy in patients with breast cancer. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
A high‐performance liquid chromatography method was developed for simultaneous detection and quantitation of total cysteine, glutathione, homocysteine and cysteinylglycine in human plasma. The two key steps in the analysis are reduction of disulfides and treatment with 1‐benzyl‐2‐chloropyridinium bromide, which rapidly and quantitatively reacts with thiol groups to form stable S‐pyridinium derivatives with intense UV absorption. The derivatives are well separated on a Zorbax SB C18 column using reversed‐phase high‐performance liquid chromatography and monitored at 315 nm. The calibration graphs were linear over concentration ranges covering most experimental and clinical cases with a regression coefficients better than 0.999. The detection and quantitation limits for all analytes were 0.2 and 0.5 µmol/L, respectively. The recoveries were 99.25–101.68%. The intra‐ and interassay imprecisions were 0.88–4.24 and 1.68–5.14%, respectively. The method was applied for plasma samples donated by apparently healthy volunteers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
A highly sensitive, rapid assay method has been developed and validated for the estimation of S‐citalopram (S‐CPM) in rat plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. The assay procedure involves a simple liquid–liquid extraction of S‐CPM and phenacetin (internal standard, IS) from rat plasma with t‐butyl methyl ether. Chromatographic separation was operated with 0.2% formic acid:acetonitrile (20:80, v/v) at a flow rate of 0.50 mL/min on a Symmetry Shield RP18 column with a total run time of 3.0 min. The MS/MS ion transitions monitored were 325.26 → 109.10 for S‐CPM and 180.10 → 110.10 for IS. Method validation and pre‐clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 0.5 ng/mL and the linearity was observed from 0.5 to 5000 ng/mL. The intra‐ and inter‐day precisions were in the range of 1.14–5.56 and 0.25–12.3%, respectively. This novel method has been applied to a pharmacokinetic study and to estimate brain‐to‐plasma ratio of S‐CPM in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
A rapid and sensitive bioassay was established and validated to simultaneously determine gemfibrozil, morphine, morphine‐3β‐glucuronide, and morphine‐6β‐glucuronide in mouse cerebrum, epencephalon, and hippocampus based on ultra‐high performance liquid chromatography and tandem mass spectrometry. The deuterated internal standard, M6G‐d3, was mixed with the prepared samples at 10 ng/mL as the final concentration. The samples were transferred into the C18 solid‐phase extraction columns with gradient elution for solid‐phase extraction. The mobile phase consisted of methanol and 0.05% formic acid (pH 3.2). Multiple reaction monitoring has been applied to analyze gemfibrozil (m/z 249.0 → 121.0) in anion mode, and M6G‐d3 (m/z 465.1 → 289.1), morphine (m/z 286.0 → 200.9), and M3G and M6G (m/z 462.1 → 286.1) in the positive ion mode. The method has a linear calibration range from 0.05 to 10 ng for gemfibrozil, morphine, and M3G and M6G with correlation coefficients >0.993. The lower limit of quantitation for all four analytes was 0.05 ng/mL, relative standard deviation of intra‐ and interday precision was less than 10.5%, and the relative error of accuracy was from ?8.2 to 8.3% at low, medium, and high concentrations for all the analytes. In conclusion, gemfibrozil can influence the morphine antinociception after coronary heart disease induced chronic angina by the change in one of morphine metabolites', M3G, distribution in mouse brain.  相似文献   

8.
A rapid, simple and sensitive UHPLC‐MS/MS method was developed and validated for the simultaneous determination of brucine, strychnine and brucine N‐oxide in rat plasma using huperzine A as an internal standard (IS) after protein precipitation with methanol. The analytes were separated on a Purospher® STAR RP18 UHPLC column (2 µm, 2.1 × 100 mm) by gradient elution using a mobile phase composed of methanol and water (containing 0.1% formic acid) at a flow rate of 0.3 mL/min. Brucine, strychnine, brucine N‐oxide and IS were detected in positive ion multiple reaction monitoring mode by means of an electrospray ionization interface (m/z 395.2 → 324.1, m/z 335.2 → 184.1, m/z 411.2 → 394.2, m/z 243.1 → 226.1). The calibration curve was linear over the range of 1–500 ng/mL for brucine and strychnine and 0.2?50 ng/mL for brucine N‐oxide. The intra‐ and inter‐day precisions of these analytes were all within 15% and the accuracy ranged from 85 to 115%. The stability experiment indicated that the plasma samples at three concentration levels were stable under different conditions. The developed method was successfully applied for the first time to pharmacokinetic studies of brucine, strychnine and brucine N‐oxide following a single oral and intravenous administration of modified total alkaloid fraction in rats. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
A rapid and sensitive liquid chromatography tandem mass spectrometry (LC/MS/MS) method was developed and validated using spinasterol as the internal standard (IS) for the simultaneous determination of shionone and epi‐friedelinol in rat plasma. Plasma samples were pretreated using liquid–liquid extraction with ethyl ether. Chromatographic separation was achieved on a C18 column (100 × 2.1 mm, 5 μm) with an isocratic elution consisting of acetonitrile–0.1% formic acid water (75:25, v/v) at a flow rate of 0.30 mL/min. Detection was performed under the selected reaction monitoring scan using an electrospray ionization in the positive ion mode. The mass transitions were as follows: m/z 427.4 → 95.1 for shionone, m/z 411.4 → 205.2 for epi‐friedelinol and m/z 395.3 → 105.2 for IS. All calibration curves exhibited good linearity (r > 0.995) over the concentration range for both components. The intra‐ and inter‐day precisions at three QC and lower limit of quantitation levels were both <10.21% in terms of relative standard deviation, and the accuracy ranged from ?7.13 to 8.02% in terms of relative error. The extraction recoveries of the compounds ranged from 82.07 to 89.81%. The developed method was successfully applied to the pharmacokinetic study of shionone and epi‐friedelinol after oral administration of Aster tataricus extract to rats. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

10.
Paclitaxel is a front‐line antineoplastic drug used in chemotherapeutic modalities for treatment of various types of malignancies. However, its efficacy is limited by dose‐related toxicities. In this study, we have explored two important biological aspects of entrapping paclitaxel in PEG2000‐DSPE micelles. First, we evaluated the impact of this micellar delivery system on P‐glycoprotein (P‐gp)–paclitaxel interaction, and we investigated differences in plasma pharmacokinetics of free and micelle‐entrapped paclitaxel. For quantification of paclitaxel, an LC–MS/MS method was developed. Paclitaxel was extracted from samples using a simple one‐step protein precipitation. Chromatographic conditions included a C18 column with a mobile phase consisting of 0.1% formic acid in acetonitrile–water (60:40, v /v) pumped at 1 mL/min. The lower limit of quantitation in both plasma and cell lysate was 1.0 ng/mL. The quantitative linear range was 1–1000 ng/mL. In addition, P‐gp efflux studies on free and micellar paclitaxel showed the proficiency of PEG2000‐DSPE micelles in evading P‐gp‐mediated efflux, thus increasing paclitaxel uptake. Furthermore, the micellar paclitaxel levels were maintained in the body for longer time as compared with taxol, which is desirable for increasing the efficacy of paclitaxel in cancer treatment.  相似文献   

11.
Bis(2‐methyl‐8‐quinolinolato)aluminum(III) hydroxide complex (AlMq2OH) is used in organic light‐emitting diodes (OLEDs) as an electron transport material and emitting layer. By means of ab initio Hartree–Fock (HF) and density functional theory (DFT) B3LYP methods, the structure of AlMq2OH was optimized. The frontier molecular orbital characteristics and energy levels of AlMq2OH have been analyzed systematically to study the electronic transition mechanism in AlMq2OH. For comparison and calibration, bis(8‐quinolinolato)aluminum(III) hydroxide complex (Alq2OH) has also been examined with these methods using the same basis sets. The lowest singlet excited state (S1) of AlMq2OH has been studied by the singles configuration interaction (CIS) method and time‐dependent DFT (TD‐DFT) using a hybrid functional, B3‐LYP, and the 6‐31G* basis set. The lowest singlet electronic transition (S0 → S1) of AlMq2OH is π → π* electronic transitions and primarily localized on the different quinolate ligands. The emission of AlMq2OH is due to the electron transitions from a phenoxide donor to a pyridyl acceptor from another quinolate ligand including C → C and O → N transference. Two possible electron transfer pathways are presented, one by carbon, oxygen, and nitrogen atoms and the other via metal cation Al3+. The comparison between the CIS‐optimized excited‐state structure with the HF ground‐state structure indicates that the geometric shift is mainly confined to the one quinolate and these changes can be easily understood in terms of the nodal patterns of the highest occupied and lowest unoccupied molecular orbitals. On the basis of the CIS‐optimized structure of the excited state, TD‐B3‐LYP calculations predict an emission wavelength of 499.78 nm. An absorption wavelength at 380.79 nm on the optimized structure of B3LYP/6‐31G* was predicted. They are comparable to AlMq2OH 485 and 390 nm observed experimentally for photoluminescence and UV‐vis absorption spectra of AlMq2OH solid thin film on quartz, respectively. Lending theoretical corroboration to recent experimental observations and supposition, the reasons for the blue‐shift of AlMq2OH were revealed. © 2003 Wiley Periodicals, Inc. Int J Quantum Chem, 2004  相似文献   

12.
A sensitive and specific method was developed and validated for the quantitation of one major metabolite of genipin in rats plasma. The major metabolite was isolated from rat bile via semi‐preparative HPLC technology and its chemical structure was identified as genipin‐1‐o‐glucuronic acid (GNP‐GLU), which was for the first time used as a standard compound for quantitative analysis in rat plasma after administration of genipin. The application of high‐performance liquid chromatography–tandem mass spectrometry in negative mode in multiple reaction monitoring mode was investigated. Chromatographic separation was achieved on an Eclipse XDB‐C18 column using a mobile phase consisting of water with 0.1% formic acid (A)–acetonitrile (B). The limit of detecation was 0.214 ng/mL and the lower limit of quantification was 0.706 ng/mL. The calibration curve was linear from 1.27 to 3810 ng/mL for plasma samples, with a correlation coefficient of 0.9924. The intra‐ and inter‐day precisions and accuracy were all within 15%. The recoveries of GNP‐GLU and puerarin were above 90.0 and 76.2%, respectively. The highly sensitive method was successfully applied to estimate pharmacokinetic parameters of GNP‐GLU following oral and intravenous administration of genipin to rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
The complexation between narrow molecular weight distribution poly(2‐vinylpyridine) (P2VP) and polystyrene (suPS) or polyisoprene (suPI) end‐functionalized with one sulfonic acid group was examined in tetrahydrofuran dilute solutions by a combination of static and dynamic laser light scattering. Both apparent weight‐average molecular weight (Mw,app) and hydrodynamic radius (Rh) of the complexes exhibited a maximum at a certain molar ratio of suPS chains to P2VP monomeric units. This indicated that the P2VP backbone may be saturated by the grafted end‐functionalized chains because of repulsion between the grafted chains. By changing the molar mass of P2VP from 100,000 to 30,000 g/mol, the values of Mw,app and Rh decreased. When suPI was used instead of suPS, similar trends were observed. In the latter case, it was possible to prepare block copolymer‐like micelles by transferring the P2VP/suPI blend solutions in decane, which is a selective solvent for PI. The non‐covalent‐bonded polymeric micelle characteristics were investigated as a function of sulfonic acid/2‐vinylpyridine units ratio as well as temperature. © 2003 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 41: 2454–2461, 2003  相似文献   

14.
A simple, robust, and rapid LC‐MS/MS method was developed for the quantitation of U0126 and validated in rat plasma. Plasma samples (20 μL) were deproteinized using 200 μL ACN containing 30 ng/mL of chlorpropamide, internal standard. Chromatographic separation performed on an Agilent Poroshell 120 EC‐C18 column (4.6 × 50 mm, 2.7 μm particle size) with an isocratic mobile phase consisting of a 70:30 v/v mixture of ACN and 0.1% aqueous formic acid. Each sample was run at 0.6 mL/min for a total run time of 2 min per sample. Detection and quantification were performed using a mass spectrometer in selected reaction‐monitoring mode with positive ESI at m/z 381 → 123.9 for U0126 and m/z 277 → 175 for the internal standard. The standard curve was linear over a concentration range of 20–5000 ng/mL with correlation coefficients greater than 0.9965. Precision, both intra‐ and interday, was less than 10.1% with an accuracy of 90.7–99.4%. No matrix effects were observed. U0126 in rat plasma degraded approximately 41.3% after 3‐h storage at room temperature. To prevent degradation, sample handling should be on an ice bath and all solutions kept at 4°C. This method was successfully applied to a pharmacokinetic study of U0126 at various doses in rats.  相似文献   

15.
A sensitive and high‐throughput LC‐MS/MS method has been developed and validated for the combined determination of esomeprazole and naproxen in human plasma with ibuprofen as internal standard. Solid‐phase extraction was used to extract both analytes and internal standard from human plasma. Chromatographic separation was achieved in 4.0 min on XBridge C18 column using acetonitrile–25 mM ammonium formate (70:30, v/v) as mobile phase. Mass detection was achieved by ESI/MS/MS in negative ion mode, monitoring at m/z 344.19 → 194.12, 229.12 → 169.05 and 205.13 → 161.07 for esomeprazole, naproxen and IS, respectively. The calibration curves were linear from 3.00 to 700.02 ng/mL for esomeprazole and 0.50 to 150.08 ng/mL for naproxen. The intra‐ and inter‐batch precision and accuracy across four quality control levels met established criteria of US Food and Drug Administration guidelines. The assay is suitable for measuring accurate esomeprazole and naproxen plasma concentrations in human bioequivalence study following combined administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

16.
A rapid, selective, and sensitive ultra‐high performance liquid chromatography‐tandem mass spectrometry method was developed for simultaneous determination of ferulic acid, paeoniflorin, and albiflorin, the major active constituents of Danggui‐Shaoyao‐San, in rat plasma using geniposide as the internal standard. The plasma samples were processed by protein precipitation with acetonitrile, and then separated on a Shim‐Pack XR‐ODS C18 column (75 mm × 3.0 mm, 2.2 μm) using gradient elution program with a mobile phase consisting of 0.1% aqueous formic acid and acetonitrile at a flow rate of 0.4 mL/min. The detection was achieved on a 3200 QTRAP mass spectrometer equipped with electrospray ionization source in negative ionization mode. Quantification was performed using multiple reaction monitoring mode by monitoring the fragmentation of m/z 192.9→134.0 for ferulic acid, m/z 525.0→120.9 for paeoniflorin, m/z 525.2→121.0 for albiflorin, and m/z 433.1→225.1 for the internal standard, respectively. The calibration curve was linear in the range of 5–2500 ng/mL for all the three analytes (r ≥ 0.9972) with the lower limit of quantitation of 5 ng/mL. The intraday and interday precisions were below 12.1% for all the analytes in terms of relative standard deviation, and the accuracy was within ±11.5% in terms of relative error. The extraction recovery, matrix effect and stability were satisfactory in rat plasma. The validated method was successfully applied to a pharmacokinetic study of ferulic acid, paeoniflorin, and albiflorin after oral administration of Danggui‐Shaoyao‐San to rats.  相似文献   

17.
A reversed‐phase high performance liquid chromatography method has been developed and validated for determination and quantitation of the natural sesquiterpene (−)‐α‐bisabolol. Furthermore the application of the method was done by characterization of chitosan milispheres and liposomes entrapping Zanthoxylum tingoassuiba essential oil, which contains appreciable amount of (−)‐α‐bisabolol. A reversed‐phase C18 column and gradient elution was used with the mobile phase composed of (A) acetonitrile–water–phosphoric acid (19:80:1) and (B) acetonitrile. The eluent was pumped at a flow rate of 0.8 mL/min with UV detection at 200 nm. In the range 0.02–0.64 mg/mL the assay showed good linearity (R2 = 0.9999) and specificity for successful identification and quantitation of (−)‐α‐bisabolol in the essential oil without interfering peaks. The method also showed good reproducibility, demonstrating inter‐day and intra‐day precision based on relative standard deviation values (up to 3.03%), accuracy (mean recovery of 100.69% ± 1.05%) and low values of detection and quantitation limits (0.0005 and 0.0016 mg/mL, respectively). The method was also robust for showing a recovery of 98.81% under a change of solvent in standard solutions. The suitability of the method was demonstrated by the successful determination of association efficiency of the (−)‐α‐bisabolol in chitosan milispheres and liposomes. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
A rapid, sensitive and selective bioanalytical method was developed for the simultaneous determination of fluoxetine and its primary metabolite norfluoxetine in human plasma. Sample preparation was based on supported liquid extraction (SLE) using methyl tert‐butyl ether to extract the analytes from human plasma. Chromatography was performed on a Synergi 4 μ polar‐RP column using a fast gradient. The ionization was optimized using ESI (+) and selectivity was achieved by tandem mass spectrometric analysis using MRM functions, m/z 310 → 44 for fluoxetine, m/z 296 → 134 for norfluoxetine and m/z 315 → 44 for fluoxetine‐d5 (internal standard). The method is linear over the range of 0.05–20 ng/mL (using a human plasma sample volume of 0.1 mL) with a coefficient determination of greater than 0.999. The method is accurate and precise with intra‐batch and inter‐batch accuracy (%bias) of <±15% and precision (%CV) of <15% for both analytes. A run time of 4 min means a high throughput of samples can be achieved. To our knowledge, this method appears to be the most sensitive one reported so far for the quantitation of fluoxetine and norfluoxetine and can be used for routine therapeutic drug monitoring or pharmacokinetic studies. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
A rapid, simple and fully validated LC‐MS/MS method was developed and validated for the determination of megestrol acetate in human plasma using tolbutamide as an internal standard (IS) after one‐step liquid–liquid extraction with methyl‐tert‐butyl‐ether. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the transitions m/z 385.5 → 267.1 for megestrol acetate and m/z 271.4 → 155.1 for IS. Chromatographic separation was performed on a YMC Hydrosphere C18 column with an isocratic mobile phase, which consisted of 10 mm ammonium formate buffer (adjusted to pH 5.0 with formic acid)–methanol (60:40, v/v) at a flow rate of 0.4 mL/min. The achieved lower limit of quantitation (LLOQ) was 1 ng/mL (signal‐to‐noise ratio > 10) and the standard calibration curve for megestrol acetate was linear (r > 0.99) over the studied concentration range (1–2000 ng/mL). The proposed method was fully validated by determining its specificity, linearity, LLOQ, intra‐ and inter‐day precision and accuracy, recovery, matrix effect and stability. The validated LC‐MS/MS method was successfully applied for the evaluation of pharmacokinetic parameters of megestrol acetate after oral administration of a single dose 800 mg of megestrol acetate (Megace?) to five healthy Korean male volunteers under fed conditions. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
A simple and sensitive analytical method based on ultraperformance liquid chromatography–tandem mass spectrometry (UPLC‐MS/MS) has been developed for determination of moclobemide in human brain cell monolayer as an in vitro model of blood–brain barrier. Brucine was employed as the internal standard. Moclobemide and internal standard were extracted from cell supernatant by ethyl acetate after alkalinizing with sodium hydroxide. The UPLC separation was performed on an Acquity UPLCTM BEH C18 column (50 × 2.1 mm, 1.7 µm, Waters, USA) with a mobile phase consisting of methanol–water (29.5:70.5, v/v); the water in the mobile phase contained 0.05% ammonium acetate and 0.1% formic acid. Detection of the analytes was achieved using positive ion electrospray via multiple reaction monitoring mode. The mass transitions were m/z 269.16 → 182.01 for moclobemide and m/z 395.24 → 324.15 for brucine. The extraction recovery was 83.0–83.4% and the lower limit of quantitation (LLOQ) was 1.0 ng/mL for moclobemide. The method was validated from LLOQ to 1980 ng/mL with a coefficient of determination greater than 0.999. Intra‐ and inter‐day accuracies of the method at three concentrations ranged from 89.1 to 100.9% for moclobemide with precision of 1.1–9.6%. This validated method was successfully applied to bidirectional transport study of moclobemide blood–brain barrier permeability. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号