相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Li Y  Li J  Chen T  Liu X  Zhang H 《Journal of chromatography. A》2011,1218(11):1503-1508
The mixed sulfated/methacryloyl polysaccharide derivative was prepared and successfully immobilized onto the surface of porous silica particles by polymerization. Polysaccharide derivative was calculated as 10.33% in the stationary phase prepared. The new stationary phase (PMSP) showed both hydrophilic interaction (HILIC) and per aqueous liquid chromatography (PALC) characteristics. The effects of column temperature, the water content, pH and ion strength of mobile phase on the retention time of test compounds in highly aqueous eluents were investigated to evaluate the PALC features of PMSP. The column efficiency is about 31,000 plates/m for benzoic acid in water/ACN (97/3, v/v) mobile phase at a flow rate of 1.0 mL/min. Compared with C18 column, the PMSP had shorter retention time for weak polar and non-polar compounds, but also showed stronger retention for strong polar compounds. It indicated that PALC was a suitable mode of chromatography as replacement of HILIC and complementarity of reversed-phase liquid chromatography (RPLC).  相似文献   

2.
硅胶色谱柱的亲水作用保留机理及其影响因素   总被引:1,自引:0,他引:1  
李瑞萍  袁琴  黄应平 《色谱》2014,32(7):675-681
亲水作用色谱(HILIC)是替代反相色谱(RPLC)分离强极性及亲水性化合物的另一色谱模式,其分离机理与RPLC有很大不同,具有和RPLC互补的选择性。在HILIC模式中,采用正相色谱(NPLC)中的极性固定相及含高浓度有机溶剂(通常为乙腈)的水溶液为流动相。硅胶是开发最早、研究最为深入及应用最为广泛的HILIC固定相,本文介绍了硅胶色谱柱的HILIC保留机理,详细概述了操作条件如硅胶柱类型、流动相组成及柱温对HILIC分离的影响,并对硅胶填料色谱柱的HILIC模式的发展方向与应用前景进行了展望。  相似文献   

3.
A rapid procedure based on a direct extraction and HPLC determination with fluorescence detection of phenylephrine in pharmaceutical sachets that include a large excess of paracetamol (65 + 1, w/w), ascorbic acid (5 + 1, w/w), and other excipients (aspartame and sucrose) was developed and validated. The final optimized chromatographic method for ion-pair chromatography used an XTerra RP18 column, 3 microm particle size, 50 x 3.0 mm id. The mobile phase consisted of a mixture of acetonitrile and buffer (10 mM sodium octane-1-sulfonate, adjusted with H3PO4 to pH 2.2; 200 + 800, v/v), with a constant flow rate of 0.3 mL/min. The separation was carried out at 30 degrees C, and the injection volume was 3 microL. Fluorescence detection was performed at excitation and emission wavelengths of 275 and 310 nm, respectively. The mobile phase parameters, such as the organic solvent fraction (acetonitrile) in mobile phase as an organic modifier, the concentration of sodium octane-1-sulfonate as a counter-ion, temperature, and pH of mobile phase, were studied. As an alternative to ion-pair chromatography, hydrophilic interaction liquid chromatography (HILIC) was investigated using a Luna HILIC column, 3 microm, 100 x 4.6 mm id. The mobile phase consisted of acetonitrile and buffer (5 mM potassium dihydrogen phosphate, adjusted with H3PO4 to pH 2.5; 750 + 250, v/v) at a flow rate of 0.8 mL/min. The separation was carried out at 25 degrees C, and the injection volume was 5 microL. The proposed method has an advantage of a very simple sample pretreatment, and is much faster than the currently utilized HPLC methods using gradient elution and UV detection. Commercial samples of sachets were successfully analyzed by the proposed HPLC method.  相似文献   

4.
徐雪峰  沈爱金  郭志谋  梁鑫淼 《色谱》2013,31(3):185-190
基于巯基硅胶与单取代-6A-烯丙氨基-β-环糊精的巯基-烯点击化学反应,制备了β-环糊精(Click TE-CD)共价键合固定相。元素分析结果表明β-环糊精被成功键合到硅胶表面。以黄酮苷类化合物为模型,考察了Click TE-CD固定相在亲水、反相和超临界流体色谱等分离模式下的色谱保留行为。黄酮苷类化合物保留时间随流动相中乙腈含量的变化呈现典型的U型曲线,表明Click TE-CD固定相具有亲水/反相的双重保留特性。应用几何学方法测得Click TE-CD固定相在反相/亲水、亲水/超临界、反相/超临界混合模式下的正交性分别为69.8%、50.8%、50.8%。对比复杂中药样品降香提取物在反相、亲水、超临界等模式下的分离情况,结果表明Click TE-CD固定相在分离中药复杂样品方面具有极大潜力,可以在一根色谱柱上通过分离模式的改变,实现二维液相色谱的分离。Click TE-CD固定相不同分离模式的分离性能和较好的正交性表明该固定相具有在液相色谱方法发展和二维液相色谱分离方面应用的潜力。  相似文献   

5.
Many samples contain compounds with various numbers of two or more regular structural groups. Such "multidimensional" samples (according to the Giddings' notation) are best separated in orthogonal chromatographic systems with different selectivities for the individual repeat structural groups, described by separation factors. Correlations between the repeat group selectivities characterize the degree of orthogonality and suitability of chromatographic systems for two-dimensional (2D) separations of two-dimensional samples. The range of the structural units in that can be resolved in a given time can be predicted on the basis of a model describing the repeat group selectivity in the first- and second-dimension systems. Two-dimensional liquid chromatographic system combining reversed-phase (RP) mode in the first dimension and normal-phase (NP) mode in the second dimension were studied with respect to the possibilities of in-line fraction transfer between the two modes. Hydrophilic interaction liquid chromatography (HILIC) with an aminopropyl silica column (APS) is more resistant than classical non-aqueous NP systems against adsorbent desactivation with aqueous solvents transferred in the fractions from the first, RP dimension to the second dimension. Hence, HILIC is useful as a second-dimension separation system for comprehensive RP-NP LCxLC. A comprehensive 2D RP-NP HPLC method was developed for comprehensive 2D separation of ethylene oxide-propylene oxide (EO-PO) (co)oligomers. The first-dimension RP system employed a 120 min gradient of acetonitrile in water on a C18 microbore column at the flow-rate of 10 microL/min. In the second dimension, isocratic HILIC NP with ethanol-dichloromethane-water mobile phase on an aminopropyl silica column at 0.5 mL/min was used. Ten microliter fractions were transferred from the RP to the HILIC NP system at 1 min switching valve cycle frequency.  相似文献   

6.
The effects of sample dilution and volume on the peak shapes in hydrophilic interaction liquid chromatography (HILIC) were evaluated using fluorescence-labeled thiols as model compounds and ZIC-HILIC as the HILIC column. The content of acetonitrile, which was selected as the diluent of the aqueous samples in this study, was varied 0?95 % in the injection samples, and the numbers of theoretical plates (NTPs) and retention times were compared using a mobile phase composed of ammonium formate buffer/acetonitrile (25:75, v/v). Although the NTPs and retention times decreased with decreasing acetonitrile content, the peak shapes were acceptable for samples with acetonitrile contents down to 50 % based on asymmetry factor. Furthermore, the sample volume had a serious effect for samples with low acetonitrile contents. Although a high content of acetonitrile in samples is still recommended, the capacity for the aqueous solution in the injection samples under HILIC conditions should vary with the composition of the mobile phase and may be larger than previously thought. These findings should be helpful in deciding the sample composition under HILIC conditions, particularly in bioanalysis, where aqueous solution is often contained in the injection samples and the sample dilution with an organic solvent may decrease the detection sensitivity.  相似文献   

7.
Isokawa  Muneki  Funatsu  Takashi  Tsunoda  Makoto 《Chromatographia》2014,77(21):1553-1556

The effects of sample dilution and volume on the peak shapes in hydrophilic interaction liquid chromatography (HILIC) were evaluated using fluorescence-labeled thiols as model compounds and ZIC-HILIC as the HILIC column. The content of acetonitrile, which was selected as the diluent of the aqueous samples in this study, was varied 0−95 % in the injection samples, and the numbers of theoretical plates (NTPs) and retention times were compared using a mobile phase composed of ammonium formate buffer/acetonitrile (25:75, v/v). Although the NTPs and retention times decreased with decreasing acetonitrile content, the peak shapes were acceptable for samples with acetonitrile contents down to 50 % based on asymmetry factor. Furthermore, the sample volume had a serious effect for samples with low acetonitrile contents. Although a high content of acetonitrile in samples is still recommended, the capacity for the aqueous solution in the injection samples under HILIC conditions should vary with the composition of the mobile phase and may be larger than previously thought. These findings should be helpful in deciding the sample composition under HILIC conditions, particularly in bioanalysis, where aqueous solution is often contained in the injection samples and the sample dilution with an organic solvent may decrease the detection sensitivity.

  相似文献   

8.
Ma S  Chen L  Luo G  Ren K  Wu J  Wang Y 《Journal of chromatography. A》2006,1127(1-2):207-213
A comprehensive two-dimensional liquid chromatography system was constructed on the combination of size exclusion chromatography (SEC) and reverse phase liquid chromatography (RPLC). The first dimension used a SEC column with 300 mm x 8mm i.d., packed with Toyopearl HW-40S. The column was eluted with 0.05 mol/l Tris-HCl (pH 6.9) at a flow rate of 0.4 ml/min. The second dimension used a RPLC column with 100 mm x 4.6mm i.d., which was operated in gradient form at a flow rate of 1.0 ml/min. An automatic switching valve was used to collect the effluent of the SEC column every 3 min, and the effluent was automatically injected into the RPLC column. Mass spectrometer was used for peak identification. This system was used to separate Qingkailing injection, a traditional Chinese medicine (TCM). The result showed that the total peak capacity of this system could reach 1134 and the qualitative analysis of seven chemical components of the Qingkailing injection was accomplished by this system. The results show that comprehensive two-dimensional liquid chromatography system is of great importance and high value in the separation of complex TCM.  相似文献   

9.
根据皂苷、黄酮苷等糖苷类化合物的结构特点,采用亲水色谱模式分析该类化合物,以弥补反相色谱模式分离结构类似糖苷类化合物选择性的不足。首先选择14个糖苷类化合物,比较了反相色谱柱(XAqua C18)和亲水色谱柱(Click XIon)的分离效果,评价了反相/亲水色谱的正交性,并构建了反相/亲水二维体系用于西洋参样品的分离。结果表明,糖苷类化合物在反相及亲水色谱柱上均有很好的保留,但两者具有不同的分离选择性,14种物质在反相和亲水柱的出峰顺序有较大差异,在反相色谱中不易分离的人参皂苷Rg1和Re在亲水色谱柱可获得很好的分离,反相/亲水模式分离糖苷化合物具有很好的正交性。以构建的RPLC/HILIC二维色谱体系分离西洋参样品,有效地提高了分离能力及峰容量,有利于后续更多极性及微量化合物的制备、结构表征与活性研究,且该方法操作简便、流动相兼容性好,可作为糖苷分离分析、制备的有效手段,也可以为其他中药复杂体系的分析提供参考。  相似文献   

10.
In this work a monolithic silica column operated in the hydrophilic interaction chromatography (HILIC) mode in conjunction with an evaporative light scattering detector (ELSD) was investigated. Lithium, sodium and potassium were used as the test counter-ions for this evaluation. Chromatographic properties of this column operated in the HILIC mode were determined by varying key mobile phase parameters, such as pH, flow rate, buffer strength, acid and organic modifier. As organic content was increased from 60 to 90% acetonitrile, retention time increased on average by a factor of seven for the test cations listed above. Buffer concentration and pH were also observed to have an effect, although not as significant as the HILIC effect that was observed by changing organic content. Flow rates up to 5 mL/min were utilized to perform counter-ion separations in less than 3 min. After examining the changes in retention, resolution, and peak shape an optimized method was established and then further evaluated for linearity, reproducibility, and limit of detection (LOD) for sodium. Linearity was acceptable with an R2 value of 0.999 across the working-standard range and a LOD of 0.1 microg/mL was calculated. The reproducibility on the counter-ion determination from pharmaceutical sodium salts was 1.6% R.S.D. on average, and the accuracy of the counter-ion prediction was approximately 3% from theory when salt content was corrected for potency.  相似文献   

11.
用内径为0.53 mm的填充毛细管正相液相色谱为第一维, 用4.6 mm(i.d.)×50 mm RP-18e整体柱反相色谱为第二维, 建立了定量环-阀切换接口的全二维液相色谱系统(NPLC×RPLC). 第一维色谱分离洗脱出的组分交替存储在十通阀上的两个定量环中, 同时定量环中前一个组分被转移到第二维进行反相分离. 因为第一维的流动相流量仅是第二维的1/500, 自然解决了流动相兼容问题. 采用芳香族化合物的混合物和中药丹参正己烷提取液对该全二维液相系统的分离能力进行了评价.  相似文献   

12.
The use of hydrophilic interaction chromatography (HILIC) with sub 2 μm particle columns for the analysis of drugs and related compounds of forensic interest is described. This technique uses a high organic/low aqueous buffered mobile phase with a polar stationary phase, and is excellent for the separation of many of the charged solutes that are found in forensic drug exhibits. In this study, HILIC is investigated for 11 solutes of forensic interest, including weak bases, weak acids, and a neutral solute. In addition, for columns containing either ethylene bridged hybrid particles with or without an amide bonded phase, the effects of acetonitrile concentration, buffer type, buffer concentration, linear velocity, and sample concentration were studied. Based on these studies, HILIC with sub 2 μm particle columns can offer highly efficient, selective, and rapid isocratic separations of drugs and related compounds of forensic interest, with excellent peak shapes and low back pressures. This is in contrast to reverse phase chromatography (RPLC), where gradient elution is usually required, which can result in extensive overlap between acidic, neutral, and basic solutes. In addition, since HILIC exhibits a much greater loading capacity than RPLC, it could be a preferred technique for drug profiling. Furthermore, because high organic content mobile phases are highly amenable to mass spectrometric detection, the use of HILIC with tandem mass spectrometric detection for the analysis of seized drugs is described.  相似文献   

13.
14.
邢倩倩  傅青  金郁  梁鑫淼 《色谱》2014,32(7):767-772
建立了亲水/反相二维色谱用于制备桔梗中三萜皂苷单体的方法。桔梗经水煮醇沉、反相和亲水两种模式的固相萃取后得到三萜皂苷类组分。选定XAmide色谱柱(150 mm×20 mm,5 μm),以乙腈和水为流动相,在亲水色谱模式下进行组分制备。选择时间触发模式,以1 min为单位进行馏分收集,得到6~25 min之间的20个三萜皂苷精细组分。以第18个馏分(JG23)为例,在反相色谱模式下采用Atlantis Prep T3色谱柱(100 mm×30 mm,5 μm)制备,得到两个单体化合物。通过质谱和核磁共振对其进行定性,确定分别为deapi-platycoside E和platycoside E。实验结果表明,该制备方法具有好的正交选择性,对于复杂样品中三萜皂苷类化合物的分离纯化有一定的借鉴意义。  相似文献   

15.
The influence of microwave irradiation on the mass transfer kinetics of an insulin variant in reversed-phase liquid chromatography (RPLC) was investigated. The elution band profiles of insulin were obtained by the pulse-response method, under linear conditions. The RPLC column was placed in a microwave oven and the incremental change in the temperature of the column effluent stream at various microwave energies and mobile phase flow rates were measured. The microwave energy dissipated in the column was set at 15 and 30 W and the mobile phase flow rate was varied from 1.0 to 2.5 mL/min at a mobile phase composition of acetonitrile, water, and trifloroacetic acid (31:69:0.1, v/v/v). The experimental data were analyzed using the conventional method of moment analysis and the lumped pore diffusion model. Regardless of mobile flow rates, the effluent temperatures measured at 15 and 30 W microwave power input were 25+/-1 and 30+/-1 degrees C, respectively. The effect of microwave irradiation on the mass transfer of the variant insulin was determined by comparing the band profiles obtained under the same experimental conditions, at the same column temperature, with and without irradiation. The calculated intraparticle diffusion coefficient, D(e), at 30 W (30+/-1 degrees C) microwave irradiation was ca. 20% higher than without irradiation at 30+/-1 degrees C. These preliminary results suggest that microwave irradiation may have a significant influence on the intraparticle diffusion of insulin in RPLC.  相似文献   

16.
In this work, a poly-l-lysine-grafted stationary phase was synthesized by polymerization of N-carboxyanhydride of l-lysine initiated by 3-aminopropylated silica. The resulting material was characterized by FT-IR spectra, elemental analysis and thermogravimetric analysis, which clearly indicated that the new phase had been prepared successfully. The retention of polar solutes depending on acetonitrile content in mobile phase exhibited ??U-shaped?? curves, which was an indication of hydrophilic interaction liquid chromatography (HILIC)/reversed-phase liquid chromatography (RPLC) mixed-mode retention behavior. The retention mechanisms in HILIC and RPLC modes also were investigated. Phenol compounds, aniline compounds and hydrophilic compounds were separated in RPLC or HILIC mode on the new stationary phase, respectively. This result shows that the new phase could be used for both RPLC and HILIC applications, providing greater flexibility for real sample analysis.  相似文献   

17.
Reversed-phase chromatography is the most common means of separation for small drug molecules. However, polar drugs may suffer from poor retention and peak shape in reversed-phase high-performance liquid chromatography (RP-HPLC). Hydrophilic interaction liquid chromatography (HILIC) provides a viable alternative to RP-HPLC and is an excellent way to separate polar compounds. This paper describes a HILIC/ESI-MS/MS assay for the determination of acyclovir from rat plasma, amniotic fluid, placental tissue, and fetal tissue. The isocratic separation utilizes an underivatized silica column with an acetonitrile/formate buffer mobile phase (80:20). The method is validated over a range of 50 ng/mL to 50 micro g/mL with % error and % relative standard deviation of <15% over 3 days. All samples are prepared by acetonitrile protein precipitation, which yields high recovery (>84% for acyclovir). This assay can be applied to the pharmacokinetic study of the placental transfer of acyclovir.  相似文献   

18.
A vacuum assisted dynamic solvent evaporation interface for coupling of two-dimensional normal phase/reverse phase liquid chromatography was developed and evaluated. A normal-phase liquid chromatographic (NPLC) column of a 250 mm × 4.6 mm I.D. 5 μm CN phase was used as the first dimension, and a reversed-phase liquid chromatographic (RPLC) column of 250 mm × 4.6 mm I.D. 5 μm C18 phase was used as the second dimension. The eluent from the first dimension flowed into a fraction loop, and the solvent in the eluent was dynamically evaporated and removed by vacuum as it was entering the fraction loop of the interface. The non-evaporable analytes was retained and enriched in about 5–25 μL solution within the loop. Up to 1 mL/min of mobile phase from the first dimension can be evaporated and removed dynamically by the interface. The mobile phase from the second dimension then entered the loop, and dissolved the concentrated analytes retained inside the loop, and carried them onto the second dimension column for further separation. The operation conditions of the two dimensions were independent from each other, and both dimensions were operated at their optimal chromatographic conditions. We evaluated the interface by controlling the loop temperature in a water bath at normal temperature, and investigated the sample losses by using standard samples with different boiling points. It was found that the sample loss due to evaporation in the interface was negligible for non-volatile samples or for components with boiling point above 340 °C. The interface realizes fast solvent removal of mL volume of fraction and concentration of the fraction into tenth of μL volume, and injection of the concentrated fraction on the secondary column. The chromatographic performance of the two-dimensional LC system was enhanced without compromise of separation efficiency and selectivity on each dimension.  相似文献   

19.
It is shown, that amphiphilic polymers--such as polysorbates and fatty esters of polyethylene glycol can be separated by comprehensive two-dimensional liquid chromatography using a reversed phase column (under critical conditions for the polyoxyethylene chain) and a HILIC column, which may arranged in different order. The mobile phases in both dimensions can be 93-97 wt% acetone water. As the retention of higher esters on the reversed phase column is very strong, this column should be used as the first dimension. On the HILIC column all fractions elute within a reasonably short time (at a flow rate of 2.5 ml/min within 2 min). With a flow rate of 0.1 ml/min in the first dimension, a full separation can be achieved in 90 min.  相似文献   

20.
A two‐dimensional (2D) hydrophilic interaction liquid chromatography (HILIC) and reverse‐phase (RP) liquid chromatography (LC) system coupled with triple‐quadrupole mass spectrometry (MS) was developed to comprehensively profile ceramides and phosphatidylcholine in extracted biological samples. Briefly, the 2D HILIC‐RPLC system used a silica HILIC column operated in the first dimension to distinguish the lipid classes and a BEH C18 column operated in the second dimension to separate the lipid species of the same class. The regression linearity of each lipid was satisfactory in both systems; however, the absolute matrix effect factor was reduced in 2D LC‐MS/MS system. Limits of detection of 2D LC‐MS/MS system were 2‐ to 3‐fold lower compared with one‐dimensional RPLC‐MS/MS. The recovery from the sample ranged from 84.5 to 110%. To summarize, the developed method was proven to be accurate and producible, as relative standard deviations remained <20% at three spiked levels. The efficiency of this newly developed system was applied to measure changes of lipids in the liver of mice after naphthalene treatment. Orthogonal projection to latent structures‐discriminant analysis discriminated the lipids from control and the treatment group. We concluded that 2D LC‐MS/MS is a promising method to assist lipidomic studies of complex biological samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   