首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Electrospray ionization mass spectrometry (ESI‐MS) is an analytical technique that measures the mass of a sample through “soft” ionization. Recent years have witnessed a rapid growth of its application in noble‐metal nanocluster (NC) analysis. ESI‐MS is able to provide the mass of a noble‐metal NC analyte for the analysis of their composition (n, m, q values in a general formula [MnLm]q), which is crucial in understanding their properties. This review attempts to present various developed techniques for the determination of the composition of noble metal NCs by ESI‐MS. Additionally, advanced applications that use ESI‐MS to further understand the reaction mechanism, complexation behavior, and structure of noble metal NCs are introduced. From the comprehensive applications of ESI‐MS on noble‐metal NCs, more possibilities in nanochemistry can be opened up by this powerful technique.  相似文献   

2.
The purpose of the present work was to evaluate the synergistic effect of ionization type, sample preparation technique, and bio-fluid on the presence of matrix effect in quantitative liquid chromatography (LC)-MS/MS analysis of illicit drugs by post-column infusion experiments with morphine (10-microg/mL solution). Three bio-fluids (urine, oral fluid, and plasma) were pretreated with four sample preparation procedures [direct injection, dilution, protein precipitation, solid-phase extraction (SPE)] and analyzed by both LC-electrospray ionization (ESI)-MS/MS and LC-atmospheric pressure chemical ionization (APCI)-MS/MS. Our results indicated that both ionization types showed matrix effect, but ESI was more susceptible than APCI. Sample preparation could reduce (clean up) or magnify (pre-concentrate) matrix effect. Residual matrix components were specific to each bio-fluid and interfered at different time points in the chromatogram. We evaluated matrix effect in an early stage of method development and combined optimal ionization type and sample preparation technique for each bio-fluid. Simple dilution of urine was sufficient to allow for the analysis of the analytes of interest by LC-APCI-MS/MS. Acetonitrile protein precipitation provided both sample clean up and concentration for oral fluid analysis, while SPE was necessary for extensive clean up of plasma prior to LC-APCI-MS/MS.  相似文献   

3.
Helicobacter pylori 3‐deoxy‐D ‐manno‐2‐octulosonate‐8‐phosphate (KDO8P) synthase catalyzes the conversion of D ‐arabinose‐5‐phosphate (A5P) and phosphoenolpyruvate (PEP) to produce KDO8P and inorganic phosphate. Since this protein is absent in mammals, it might therefore be an attractive target for the development of new antibiotics. Unlike E. coli KDO8P synthase (class I), the H. pylori counterpart is a class II enzyme, where it requires a divalent transition metal ion for catalysis. Although the metal ions have been shown to be important for catalysis, their role in the structure is not understood. Using electrospray ionization mass spectrometry (ESI‐MS), the role of the metal ions in H. pylori KDO8P synthase has been investigated. This protein is found to be a tetramer in the gas phase but dissociates into the dimer with increasing declustering potential (DP2) suggesting an existence of a ‘structurally specific’ tetramer. An examination of mass spectra revealed that the tetrameric state of the Cd2+‐reconstituted enzyme is less stable than those of the Zn2+‐, Co2+‐ and Cu2+‐enzymes. The stoichiometry of metal binding to the protein depends on the nature of the metal ion. Taken together, our data suggest that divalent metal ions play an important role in the quaternary structure of the protein and the tetrameric state may be primarily responsible for catalysis. This study demonstrates the first structural characterization and stoichiometry of metal binding in class II KDO8P synthase using electrospray ionization quadrupole time‐of‐flight mass spectrometry under nondenaturing conditions. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Electrospray ionization mass spectrometry (ESI MS) has emerged recently as a powerful tool for analyzing many structural and behavioral aspects of metalloproteins in great detail. In this review we discuss recent developments in the field, placing particular emphasis on the unique features of ESI MS that lend themselves to metalloprotein characterization at a variety of levels. Direct mass measurement enables the determination of protein-metal ion binding stoichiometry in solution and metalloprotein higher order structure in the case of multi-subunit proteins. MS techniques have been developed for determining the locations of metal-binding centers, metal oxidation states and reaction intermediates of metal-containing enzymes. Other ESI MS techniques are also discussed, such as protein ion charge state distributions and hydrogen/deuterium exchange studies, which can be used to measure metal binding affinities and to shed light on vital dynamic aspects of the functional properties of metalloproteins endowed by metal binding.  相似文献   

5.
Protein complexes play pivotal roles in cellular life. Nevertheless, their characterization remains a substantial challenge. Mass spectrometry (MS) is an emerging tool to study protein assemblies, and electrospray ionization (ESI) is often used because it preserves non‐covalent interactions. Matrix‐assisted laser desorption/ionization (MALDI) represents an important alternative to ESI because it is more tolerant to salts and detergents (e.g. necessary in the case of membrane complex analyses). Prior to MALDI‐MS, the subunits should be crosslinked (XLed). Moreover, crosslinking (XLing) is useful when constraint distances are determined to obtain low‐resolution structural information. Here we report a novel XLing approach to study protein complexes with MALDI‐MS. We investigated two tetramers (i.e. alcohol dehydrogenase and aldolase) larger than 140 kDa at two pH values (7.2 and 8.0). We tested two different crosslinkers (XLers) (i.e. BS3 and glutaraldehyde), used separately or in combination. We utilized gentle agitation and ultracentrifugation. Our data shows that the pH influenced the XLing when using a single XLer. Combining two XLers was demonstrated to be more efficient than using a reagent alone. In particular, the combination determined a higher degree of XLing and lower mass shift. This could suggest a ranking in target amino acid availability. First residues at specific distances are linked by BS3, then glutaraldehyde binds residues that are still available at larger distances. Ultracentrifugation and gentle agitation both provide similar degrees of XLing, but the former method determined a lower mass increment resulting from redundant XLing. To conclude, we present an efficient dual XLing approach for determining mass and stoichiometry of protein assemblies. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
In a previous work, direct‐infusion electrospray ionization ion trap tandem mass spectrometry (ESI‐IT‐MS/MS) was applied to the study of anthocyanins in extracts from the skins of Clinton grapes, a non‐Vitis vinifera red grape variety qualitatively and quantitatively rich in anthocyanins. A good characterization of anthocyaninins was obtained, but it was impossible to differentiate some compounds with the same nominal mass but with different elemental composition. In this work, the capabilities of quadrupole time‐of‐flight mass spectrometry (QTOF‐MS) coupled with Chip‐liquid chromatography (LC‐Chip) were applied to the study of Clinton anthocyanins and this method provided the complete sample anthocyanin fingerprint in less than 5 min. Multi‐stage mass spectrometry (MSn; n >2) was not necessary to identify isobaric compounds, nor were deuterium‐exchange experiments necessary to distinguish between compounds containing the same aglycone. The fast separation bypasses the problem of petunidin‐3‐O‐(6‐O‐acetyl)monoglucoside and delphinidin‐3,5‐O‐diglucoside quantification, present in the direct‐infusion ESI‐ITMS approach, due to overlapping with matrix interferences. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
Noncovalent interactions between drugs and proteins play significant roles for drug metabolisms and drug discoveries. Mass spectrometry has been a commonly used method for studying noncovalent interactions. However, the harsh ionization process in electrospray ionization mass spectrometry (ESI‐MS) is not conducive to the preservation of noncovalent and unstable biomolecular complexes compared with the cold spray ionization mass spectrometry (CSI‐MS). A cold spray ionization providing a stable solvation‐ionization at low temperature is milder than ESI, which was more suitable for studying noncovalent drug‐protein complexes with exact stoichiometries. In this paper, we apply CSI‐MS to explore the interactions of ginsenosides toward amyloid‐β‐peptide (Aβ) and clarify the therapeutic effect of ginsenosides on Alzheimer's disease (AD) at the molecular level for the first time. The interactions of ginsenosides with Aβ were performed by CSI‐MS and ESI‐MS, respectively. The ginsenosides Rg1 bounded to Aβ at the stoichiometries of 1:1 to 5:1 could be characterized by CSI‐MS, while dehydration products are more readily available by ESI‐MS. The binding force depends on the number of glycosyls and the type of ginsenosides. The relative binding affinities were sorted in order as follows: Rg1 ≈ Re > Rd ≈ Rg2 > Rh2, protopanaxatriol by competition experiments, which were supported by molecular docking experiment. CSI‐MS is expected to be a more appropriate approach to determine the weak but specific interactions of proteins with other natural products especially polyhydroxy compounds.  相似文献   

8.
A method for the simultaneous quantitative determination of deoxynivalenol (DON), T‐2 toxin (T‐2), HT‐2 toxin (HT‐2) and zearalenone (ZEN) in wheat and biscuit by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) coupled with immunoaffinity extraction is described. A clean‐up was carried out using a DZT MS‐PREP® immunoaffinity column (IAC), and the effect of the sample dilution rate and sample loading was investigated. Furthermore, the effects of ion suppression of a multifunctional column (MFC) and the IAC in the clean‐up were compared. The results with the DZT MS‐PREP® IAC showed that it is possible to make the sample dilution rate low, and indicated a higher solvent‐tolerance than usual with an IAC. Sample loading was optimized at 0.25 g. Ion suppression was lowered by purification of the toxins using the DZT MS‐PREP® IAC. Recoveries of each mycotoxin from wheat and biscuit samples spiked at two levels ranged from 78 to 109%. The limits of detection in wheat and biscuit was in the range of 0.03–0.33 ng·g?1. From these studies, it is suggested that use of an IAC is effective in the clean‐up of each mycotoxin, and, when combined with LC/ESI‐MS/MS, it is good for the determination of mycotoxins in foodstuffs due to its rapidity and high sensitivity. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
Native non‐covalently bonded protein‐protein and protein‐substrate complexes are of great interest and have been extensively studied by electrospray ionization mass spectrometry (ESI‐MS). Multiply charged protein homomultimeric complexes are shown to form by ESI‐MS. This study addresses factors that can artificially induce the formation of multiply charged protein homomultimeric complexes. Cytochrome c (Cyt c) and ubiquitin, which are monomers in solution, were found to generate (Cyt c)mn+ by electrospray ionization (ESI). The homomultimeric complexes were not limited to dimeric complexes but include also multiply charged trimers, tetramers, and pentamers. The observation of these homomultimeric complexes has never been revealed from a Cyt c solution at the concentration as low as 10 μM. Increasing the concentration of Cyt c enhanced the formation of (Cyt c)mn+ as expected; however, the protein concentration does not affect the relative intensities of monomeric and dimeric complexes. Additionally the enrichment of NH4OH also promotes the formation of (Cyt c)mn+. Notably, source collision‐induced dissociations (source‐CID) of (Cyt c)mn+ alter the charge state distribution (CSD) and may lead to an incorrect interpretation of Cyt c conformations. Hence, extra care should be taken when using CSD to interpret the conformation of a protein derived from ESI‐MS.  相似文献   

10.
Probe electrospray ionization (PESI) is a modified version of the electrospray ionization (ESI), where the capillary for sampling and spraying is replaced by a solid needle. High tolerance to salts and direct ambient sampling are major advantages of PESI compared with conventional ESI. In this study, PESI‐MS was used to monitor some biological and chemical reactions in real‐time, such as acid‐induced protein denaturation, hydrogen/deuterium exchange (HDX) of peptides, and Schiff base formation. By using PESI‐MS, time‐resolved mass spectra and ion chromatograms can be obtained reproducibly. Real‐time PESI‐MS monitoring can give direct and detailed information on each chemical species taking part in reactions, and this is valuable for a better understanding of the whole reaction process and for the optimization of reaction parameters. PESI‐MS can be considered as a potential tool for real‐time reaction monitoring due to its simplicity in instrumental setup, direct sampling with minimum sample preparation and low sample consumption. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
The native form of Cu,Zn‐superoxide dismutase (SOD‐1) is a homodimer that coordinates one Cu2+ and one Zn2+ per monomer. Cu2+ and Zn2+ ions play crucial roles in enzyme activity and structural stability, respectively. In addition, dimer formation is essential for SOD‐1 functionality, and in humans several SOD‐1 mutant isoforms have been associated with certain types of amyotrophic lateral sclerosis (ALS), a progressive neurodegenerative disorder. In this paper we used capillary electrophoresis and mass spectrometry to study the different structures of bovine SOD‐1. The metal ions of the native enzyme (Cu2,Zn2‐dimer SOD‐1) were released in acidic medium in order to obtain apo‐SOD‐1, which is a monomer. Both substances were analyzed by matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF‐MS) and capillary electrophoresis with ultraviolet and electrospray ionization mass spectrometry detection (CE/UV and CE/ESI‐MS, respectively). With MALDI‐TOF‐MS, using matrices of sinapinic acid (SA) or 2,5‐dihydroxybenzoic acid (DHB) with or without trifluoroacetic acid (TFA), similar mass spectra were obtained for the metalated and non‐metalated samples. In both cases, an average molecular mass corresponding to the apo‐monomer SOD‐1 was calculated. This finding indicated that the metals were released from the Cu2,Zn2‐dimer SOD‐1 during sample preparation or ionization. For CE/UV and CE/ESI‐MS, two background electrolytes (BGEs) potentially compatible with ESI‐MS detection were used, namely 1 M of acetic acid (pH 2.3) and 10 mM of ammonium acetate (pH 7.3). Using a sheath liquid of 2‐propanol/water (60:40 v/v), with or without 0.1% v/v of formic acid, CE/ESI‐MS sensitivity was enhanced when the acidic BGE and the acidic sheath liquid were used. However, the electrophoretic profiles and the mass spectra obtained suggested that the metals of Cu2,Zn2‐dimer SOD‐1 were released, which generated the apo‐monomer during the electrophoretic separation. The neutral BGE provided enhanced conditions for the detection of the native enzyme. The differences between the mass spectra obtained for the Cu2,Zn2‐dimer and the apo‐monomer forms were significant and the presence of formic acid in the sheath liquid affected only sensitivity. Our results highlight the importance of selecting appropriate non‐denaturing separation and detection conditions to obtain reliable structural information about non‐covalent protein complexes by CE/ESI‐MS. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
The interaction between metals and naturally occurring humic substances and the thereby induced issues of bioavailability and hydrogeochemical turnover of metal ions in natural waters have been the subject of intense study for decades. Traditional bulk techniques to investigate metal‐humic binding (e.g. potentiometry and inductively coupled plasma mass spectrometry (ICP‐MS)) can provide quantitative results for the relative abundance and distribution of metal species in humic samples and/or overall binding constants. The shortcoming of these bulk techniques is the absence of structural detail. Ultra‐high‐resolution mass spectrometry, currently the only technique demonstrated to resolve individual humic ions, is not generally employed to provide the missing qualitative information primarily because the identification of metal complexes within the already complex mixtures of humic substances is non‐trivial and time‐consuming to the extent of eliminating any possibility for real‐time manipulation of chelated analytes. Here, it is demonstrated that with tailored selection of the metal ion, it is possible to visually identify large numbers of metal‐humic complexes (~500 for Be2+, ~1100 for Mn2+, and ~1500 for Cr3+) in real‐time as the spectra are being acquired. Metal ions are chosen so that they form primarily even‐m/z complexes with humic ions. These even‐m/z complexes stand out in the spectrum and can readily be characterized based on molecular formulae, which here revealed for example that Suwannee River fulvic acid (SRFA) complexes encompassed primarily highly oxygenated fulvic acids of relatively low double‐bond equivalence. Facile, real‐time identification of even‐m/z metal‐humic complexes additionally allows for the specific selection of metal‐humic complexes for MSn analysis and in‐trap ion‐neutral reactions enabling investigation of metal‐humic complex structure. MS/MS data were collected to demonstrate the potential of the technique as well as highlight some of the remaining challenges. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A novel ion/molecule reaction was observed to occur under electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photo ionization (APPI) conditions, leading to dimerization of ionized 4‐(methyl mercapto)‐phenol followed by fast H· loss. The reaction is particularly favored during ESI, which suggests that this ion/molecule reaction can occur both in the solution inside the ESI‐charged droplets and in the gas‐phase environment of most other atmospheric pressure ionization techniques. The dimerization reaction is inherent to the electrolytic process during ESI, whereas it is more by ion/molecule chemistry in nature during APCI and APPI. From the tandem mass spectrometry (MS/MS) data, accurate mass measurements, hydrogen/deuterium (H/D) exchange experiments and density functional theory (DFT) calculations, two methyl sulfonium ions appear to be the most likely products of this electrophilic aromatic substitution reaction. The possible occurrence of this unexpected reaction complicates mass spectral data interpretation and can be misleading in terms of structural assignment as reported herein for 4‐(methyl mercapto)‐phenol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Sesquiterpene lactones (SL) have been reported with various biological effects. Among the described SL skeletons, hirsutinolide and glaucolide have not been extensively studied by mass spectrometry (MS), especially how to distinguish them in organic matrices. Thus, this paper reports (1) a strategy of their differentiation based on MS behavior during the ionization and (2) a proposal of the fragmentation pattern for both SL‐subtypes. ESI(+)‐HRMS data of four isolated SL (hirsutinolides 1 and 3 ; glaucolides 2 and 4 ) were recorded by direct and UPLC water‐sample combined injections. These analyses revealed that hirsutinolides and glaucolides formed [M+Na]+ ion during the operation of the direct MS injection, and ([M+Na]+ and [M+H‐H2O]+) and [M+H]+ ions were respectively observed for hirsutinolides and glaucolides during the operation of combined UPLC water and sample MS injection. Computational simulations showed that the complex hirsutinolide ( 1 )‐Na+ formed with a lower preparation energy compared with the complex glaucolide ( 2 )‐Na+. However, despite their different behavior during the ionization process, ESI(+)‐HRMS/MS analyses of 1 ‐ 4 gave similar fragmentation patterns at m/z 277, 259, 241, and 231 that can be used as diagnostic ions for both skeletons. Moreover, the differentiation strategy based on the nature of the complex SL‐adducts and their MS/MS fragmentation pattern were successfully applied for the chemical characterization of the extract from Vernonanthura tweedieana using UPLC‐ESI‐HRMS/MS. Among the characterized metabolites, SL with hirsutinolide and glaucolide skeletons showed the aforementioned diagnostic fragments and an ionization behavior that was similar to those observed during the water‐sample combined injection.  相似文献   

15.
The novel PNP‐lariat ether L with cyclotriphosphazene ring incorporated in the macrocyclic structure was synthesized and checked by the electrospray mass spectrometry (ESI‐MS) method for the ability to bind different types of ions Ag+, Ca2+, Cd2+, Cu2+, and Pb2+. Furthermore, the stability constants of the abovementioned ion complexes with the investigated ligand have been determined by direct and competitive potentiometric methods. To evaluate the stability of various complex types and to confirm the way of metal cation binding, the tandem mass spectra of the investigated ligand and its complexes were taken. As a result, we obtained quite a good relationship between the number and main types of complex species observed in ESI‐MS experiments and the forms of complexes for which the stabilization constants were determined by potentiometric methods. Moreover, we also concluded that in case of big discrepancies of stability constants, ESI‐MS experiments could provide information about the most stable form of the complexes, but they fail when the differences between the strength of the coordination binding are slightly different.  相似文献   

16.
Taking advantage of the electrochemical aspects of electrospray ionization (ESI) sources in positive ionization mode mass spectrometry (MS), aqueous copper complexes are electrogenerated using sacrificial copper electrodes. When using 8-hydroxyquinoline or bathocuproine, two chelating agents for Cu2+ and Cu+ ions, respectively, the electrodissolution of copper leads to the formation of the respective complexes that are then analyzed by MS. This electrochemical generation of copper(I) complexes offers a direct route to synthesize Cu+ complexes in aqueous solutions.  相似文献   

17.
Metal salen complexes are one of the most frequently used catalysts in enantioselective organic synthesis. In the present work, we compare a series of ionization methods that can be used for the mass spectral analysis of two types of metalosalens: ionic complexes (abbreviated as Com+X?) and neutral complexes (NCom). These methods include electron ionization and field desorption (FD) which can be applied to pure samples and atmospheric pressure ionization techniques: electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) which are suitable for solutions. We found that FD is a method of choice for recording molecular ions of the complexes containing even loosely bonded ligands. The results obtained using atmospheric pressure ionization methods show that the results depend mainly on the structure of metal salen complex and the ionization method. In ESI spectra, Com+ ions were observed, while in APCI and APPI spectra both Com+ and [Com + H]+ ions are observed in the ratio depending on the structure of the metal salen complex and the solvent used in the analysis. For complexes with tetrafluoroborate counterion, an elimination of BF3 took place, and ions corresponding to complexes with fluoride counterion were observed. Experiments comparing the relative sensitivity of ESI, APCI and APPI (with and without a dopant) methods showed that for the majority of the studied complexes ESI is the most sensitive one; however, the sensitivity of APCI is usually less than two times lower and for some compounds is even higher than the sensitivity of ESI. Both methods show very high linearity of the calibration curve in a range of about 3 orders of magnitude of the sample concentration. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
The novel N‐1‐sulfonylcytosine‐cyclam conjugates 1 and 2 conjugates are ionized by electrospray ionization mass spectrometry (ESI MS) in positive and negative modes (ES+ and ES) as singly protonated/deprotonated species or as singly or doubly charged metal complexes. Their structure and fragmentation behavior is examined by collision induced experiments. It was observed that the structure of the conjugate dictated the mode of the ionization: 1 was analyzed in ES mode while 2 in positive mode. Complexation with metal ions did not have the influence on the ionization mode. Zn2+ and Cu2+ complexes with ligand 1 followed the similar fragmentation pattern in negative ionization mode. The transformation from 2°‐amine in 1 to 3°‐amine of cyclam ring in 2 leads to the different fragmentation patterns due to the modification of the protonation priority which changed the fragmentation channels within the conjugate itself. Cu2+ ions formed complexes practically immediately, and the priority had the cyclam portion of the ligand 2 . The structure of the formed Zn2+ complexes with ligand 2 depended on the number of 3° amines within the cyclam portion of the conjugate and the ratio of the metal:ligand used. The cleavage of the cyclam ring of metal complexes is driven by the formation of the fragment that suited the coordinating demand of the metal ions and the collision energy applied. Finally, it was shown that the structure of the cyclam conjugate dictates the fragmentation reactions and not the metal ions.  相似文献   

19.
Using the bovine species as a biological model, direct infusion chip‐based nano‐electrospray ionization mass spectrometry (nano‐ESI‐MS) fingerprinting in the positive ion mode is used to obtain fast chemical profiles of media used for in vitro production of bovine embryos. Nano‐ESI‐MS fingerprinting is useful for characterization and routine quality control requiring no sample pre‐separation, being able to differentiate four different media (IVM, IVF, SOF and HSOF) via principal component analysis (PCA). For media stored at +4°C for up to 45 days, no significant (p > 0.05) variation was observed in cleavage and blastocyst rate development, as well as in the nano‐ESI‐MS chemical profiles. For media exposed to a heat shock (60°C for 3 h), no significant decrease (p > 0.05) in embryo development rates was observed, but nano‐ESI‐MS profiles were quite distant from fresh control media in the PCA. For frozen media (?70°C for 2 months), again no significant variation (p > 0.05) in embryo development was noticed, but nano‐ESI‐MS profiles from all media were significantly affected. These results indicate that nano‐ESI(+)‐MS fingerprinting was able to characterize different media based on their specific chemical profile. The technique seems therefore applicable as a routine quality control assay, detecting, for example, compositional changes after temperature variations that may affect post‐transfer embryo viability. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
Total phenolic choline ester fractions prepared from seeds of Arabidopsis thaliana and Brassica napus were analyzed by capillary LC/ESI‐QTOF‐MS and direct infusion ESI‐FTICR‐MS. In addition to the dominating sinapoylcholine, 30 phenolic choline esters could be identified based on accurate mass measurements, interpretation of collision‐induced dissociation (CID) mass spectra, and synthesis of selected representatives. The compounds identified so far include substituted hydroxycinnamoyl‐ and hydroxybenzoylcholines, respective monohexosides as well as oxidative coupling products of phenolic choline esters and monolignols. Phenolic choline esters are well separable by reversed‐phase liquid chromatography and sensitively detectable using electrospray ionization mass spectrometry in positive ion mode. CID mass spectra obtained from molecular ions facilitate the characterization of both the type and substitution pattern of such compounds. Therefore, LC/ESI‐MS/MS represents a valuable tool for comprehensive qualitative and quantitative analysis of this compound class. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号