共查询到20条相似文献,搜索用时 0 毫秒
1.
Hydrophilic interaction chromatography with Fourier transform mass spectrometry of monosaccharide anhydrides 下载免费PDF全文
A fast, selective, and sensitive method for the determination of three monosaccharide anhydrides (galactosan, mannosan, levoglucosan), based on hydrophilic interaction chromatography and Fourier transform mass spectrometry, was successfully developed. The simple experimental stationary phase and mass spectrometry performance screening allowed the selection of the best available chromatographic and mass spectrometry conditions. Thus, the chromatographic separation was performed on a highly selective stationary phase containing a zwitterionic phosphorylcholine group and the monosaccharide anhydrides were detected as [M+HCOO]? adduct in the negative mode. The method showed accuracy in the range of 84–111 and 89–102% with interbatch precision expressed as relative standard deviations of 5.6–15.4 and 5.0–9.0% for the aerosol extract and snow samples, respectively. The limit of quantification in absolute values ranged from 10 to 30 pg, the limit of quantification, expressed as concentration, ranged was 0.3–0.9 ng/m3 for aerosol and 10–20 ng/mL for snow samples. The method was successfully applied for the determination of monosaccharide anhydrides in aerosol and snow samples. 相似文献
2.
Kamleh A Barrett MP Wildridge D Burchmore RJ Scheltema RA Watson DG 《Rapid communications in mass spectrometry : RCM》2008,22(12):1912-1918
It was shown that coupling hydrophilic interaction chromatography (HILIC) to Orbitrap Fourier transform mass spectrometery (FT-MS) provided an excellent tool for metabolic profiling, principally due to rapid elution of lipids in advance of most metabolites entering the mass spectrometer. We used in vitro cultivated procyclic forms of the protozoan parasite Trypanosoma brucei as a source of metabolites to test the performance of the HILIC column and the mass accuracy of MS. The mass accuracy achieved fell within 2 ppm for all the metabolites identified within samples. It was, for example, possible to identify the signature metabolite of the trypanosome, trypanothione, and also glutathione which were well retained by the HILIC column. By comparing trypanosomes grown in two different media we were able to clearly distinguish the samples in terms of the relative abundance of a number of metabolites using Sieve 1.1 software. 相似文献
3.
Marina Russo Filomena Cichello Carla Ragonese Paola Donato Francesco Cacciola Paola Dugo Luigi Mondello 《Analytical and bioanalytical chemistry》2013,405(13):4617-4626
In this work, a high-performance liquid chromatography with evaporative light scattering detection method has been developed and applied for quantification of the polar content of the lipid fraction in milk samples of different origin. From a chromatographic stand-point, a 4.6-mm I.D. hydrophilic interaction liquid chromatography column was employed to attain a baseline separation of major phospholipid classes contained in the various milk samples tested. Quantitative analysis was performed by the external calibration method using reference material solutions in the 5–100 mg/L concentration range. Analytical recoveries ranging from 57 to 100 %, and repeatability data lower than 8.04 % were obtained on a skimmed cow’s milk sample. The crude cow milk was the most abundant (0.04 %) in phospholipids and donkey milk was the poorest (0.004 %). Quantitative differences were determined in the phospholipid content of the milk samples tested. Finally, characterization of phospholipid profile and fatty acid composition of the different samples was carried out by an ion trap-time of flight mass spectrometer and gas chromatography coupled to flame ionization and mass spectrometry detection. A thorough screening of the polar lipid composition of milk samples of different origin is here outlined, for the first time. 相似文献
4.
Hammad LA Cooper BS Fisher NP Montooth KL Karty JA 《Rapid communications in mass spectrometry : RCM》2011,25(19):2959-2968
We present here the findings of global profiling of Drosophila lipids using liquid chromatography/tandem mass spectrometry (LC/MS/MS) on an LTQ-Orbitrap instrument. In addition, we present a multiple reaction monitoring (LC-MRM) method for the absolute quantification of the major phosphatidylethanolamine (PE) and phosphatidylcholine (PC) lipids of Drosophila. Using both normal- and reversed-phase LC followed by accurate mass analysis and MS/MS on an LTQ-Orbitrap instrument, we evaluated the lipid composition of the fruit fly Drosophila melanogaster. A total of 74 lipid species were identified consisting of glycerphospholipids belonging to the PE, PC, phosphatidylglycerol (PG), phosphatidylinositol (PI) and phosphatidylserine (PS) classes including several plasmanyl PE species, as well as triacylglycerides, cardiolipins, ceramides, and PE ceramides. Individual PE and PC phospholipids were then quantified using an LC-MRM approach. Reversed-phase chromatography followed by monitoring on a QTrap 4000 instrument of 21 MRM transitions combined with calibration curves constructed using internal standards enabled the absolute quantification of 28 PE and PC lipid species with limits of quantification of 3 and 5 pg/μL, respectively. Internal standards accounted for the differences in ionization efficiencies of PE and PC phospholipids, facilitating more accurate lipid abundance measurements. The method presented here builds on previous Drosophila work by making the quantification of absolute lipid abundance possible and will be of interest to scientists who study variation and changes in the degree of unsaturation, fatty acid carbon length, and head-group concentration among individuals of different genotypes in response to environmental, genetic, or physiological perturbation in small insects. It will also be particularly useful to biologists interested in adaptation and acclimation of cellular membranes in response to thermal heterogeneity. 相似文献
5.
Ji HY Jeong DW Kim YH Kim HH Yoon YS Lee KC Lee HS 《Rapid communications in mass spectrometry : RCM》2006,20(14):2127-2132
A rapid, sensitive and selective method for the determination of gabapentin in human plasma was developed using hydrophilic interaction liquid chromatography/tandem mass spectrometry (HILIC/MS/MS). The devised method involved protein precipitation with acetonitrile followed by separation on an Atlantis HILIC silica column using an acetonitrile/ammonium formate mobile phase (100 mM, pH 3.0) (85:15, v/v). Analytes were detected using an electrospray ionization mass spectrometer in the multiple-reaction monitoring mode. The standard curve was linear (r = 1.000) over the concentration range of 50.0-10000 ng/mL. The lower limit of quantification for gabapentin was 50.0 ng/mL (ca. 20 pg gabapentin) using a 10-microL plasma sample. The coefficients of variation and relative errors for intra- and inter-assay at four QC levels (i.e., 50.0, 125, 750, and 7500 ng/mL) were 4.7 to 9.4% and -4.1 to 1.6%, respectively. Absolute and relative matrix effects for gabapentin and metformin were practically absent. Gabapentin and metformin recoveries were 98.5% and 99.0%, respectively. This method was successfully applied to a bioequivalence study of gabapentin in humans. 相似文献
6.
Hydrophilic interaction LC with MS/MS (HILIC-MS/MS) was described as a rapid, sensitive, and selective method for the quantification of doxazosin in human plasma. Doxazosin and cisapride (internal standard) were extracted from human plasma with ethyl acetate at alkaline pH and analyzed on an Atlantis HILIC Silica column with the mobile phase of ACN/ammonium formate (100 mM, pH 4.5) (93:7 v/v). The analytes were detected using an ESI MS/MS in the selective-reaction-monitoring mode. The standard curve was linear (r = 0.9994) over the concentration range of 0.2-50 ng/mL. The LOQ for doxazosin was 0.2 ng/mL using 100 microL plasma sample. The CV and relative error for intra- and interassay at four QC levels were 3.7-8.7% and 0.0-9.8%, respectively. The matrix effect for doxazosin and cisapride were practically absent. The recoveries of doxazosin and cisapride were 67.4 and 61.7%, respectively. This method was successfully applied to the pharmacokinetic study of doxazosin in humans. 相似文献
7.
Characterizing plant cell wall derived oligosaccharides using hydrophilic interaction chromatography with mass spectrometry detection 总被引:1,自引:0,他引:1
Analysis of complex mixtures of plant cell wall derived oligosaccharides is still challenging and multiple analytical techniques are often required for separation and characterization of these mixtures. In this work it is demonstrated that hydrophilic interaction chromatography coupled with evaporative light scattering and mass spectrometry detection (HILIC-ELSD-MS(n)) is a valuable tool for identification of a wide range of neutral and acidic cell wall derived oligosaccharides. The separation potential for acidic oligosaccharides observed with HILIC is much better compared to other existing techniques, like capillary electrophoresis, reversed phase and porous-graphitized carbon chromatography. Important structural information, such as presence of methyl esters and acetyl groups, is retained during analysis. Separation of acidic oligosaccharides with equal charge yet with different degrees of polymerization can be obtained. The efficient coupling of HILIC with ELSD and MS(n)-detection enables characterization and quantification of many different oligosaccharide structures present in complex mixtures. This makes HILIC-ELSD-MS(n) a versatile and powerful additional technique in plant cell wall analysis. 相似文献
8.
Ihling C Berger K Höfliger MM Führer D Beck-Sickinger AG Sinz A 《Rapid communications in mass spectrometry : RCM》2003,17(12):1240-1246
Fourier transform ion-cyclotron resonance (FTICR) mass spectrometry offers several advantages for the analysis of biological samples, including excellent mass resolution, ultra-high mass measurement accuracy, high sensitivity, and wide mass range. We report the application of a nano-HPLC system coupled to an FTICR mass spectrometer equipped with nanoelectrospray source (nano-HPLC/nano-ESI-FTICRMS) for proteome analysis. Protein identification in proteomics is usually conducted by accurately determining peptide masses resulting from enzymatic protein digests and comparing them with theoretically digested protein sequences from databases. A tryptic in-solution digest of bovine serum albumin was used to optimize experimental conditions and data processing. Spots from Coomassie Blue and silver-stained two-dimensional (2D) gels of human thyroid tissue were excised, in-gel digested with trypsin, and subsequently analyzed by nano-HPLC/nano-ESI-FTICRMS. Additionally, we analyzed 1D-gel bands of membrane preparations of COS-6 cells from African green monkey kidney as an example of more complex protein mixtures. Nano-HPLC was performed using 1-mm reverse-phase C-18 columns for pre-concentration of the samples and reverse-phase C-18 capillary columns for separation, applying water/acetonitrile gradient elution conditions at flow rates of 200 nL/min. Mass measurement accuracies smaller than 3 ppm were routinely obtained. Different methods for processing the raw data were compared in order to identify a maximum number of peptides with the highest possible degree of automation. Parallel identification of proteins from complex mixtures down to low-femtomole levels makes nano-HPLC/nano-ESI-FTICRMS an attractive approach for proteome analysis. 相似文献
9.
10.
Metal complexes of Fe(III) such as Fe(III) ethylene diamine tetraacetic acid (FeETDA) have been observed to be effective molluscicides. The mechanism of toxicity of FeEDTA complex on molluscs is not clear and it is also not known if Fe(III) in the form FeEDTA is absorbed more effectively by snails than simple iron salts. Snails were fed with molluscicide pellets containing the FeEDTA complex and also with pellets containing FePO(4) after 3-4 days the hearts, kidneys and dart sacs removed and analysed for Fe(III) content. Hydrophilic interaction liquid chromatography (HILIC) coupled with Fourier transform electrospray ionisation mass spectrometry (FT-ESIMS) was used to analyse the sample extracts. The method had a very wide linear range from 2 to 10,000 ngmL(-1), intra- and inter-day precisions of ca. +/-0.5% were observed for the analysis of extracts from snail tissues spiked with Fe(III). The limit of detection was of 0.5 ngmL(-1) for a 20 microL injection. The levels of Fe(III) in tissues from snails fed Fe EDTA pellets were 10-100 times higher than the levels in snails fed FePO(4) pellets. The analysis of Cu, Zn, Ca and Mn could also be carried out using the same analytical procedure. 相似文献
11.
A hydrophilic interaction chromatographic (HILIC) system interfaced with atmospheric pressure ionization (API) sources and a tandem mass spectrometer (MS/MS) was developed for the simultaneous determination of nicotinic acid (NiAc) and its metabolites in dog plasma in support of a pharmacokinetic study. A silica column was adapted for separation of NiAc and its two metabolites, nicotinamide (NiNH2) and nicotinuric acid (NiUAc), under HILIC conditions. The influence of experimental factors such as the composition of mobile phase on ionization efficiency and chromatographic performance of all analytes was investigated. The feasibility of the proposed HILIC/MS/MS methods was explored by comparing the plasma levels of NiAc, NiNH2, and NiUAc in dog obtained by using either electrospray ionization or atmospheric pressure chemical ionization interfaces in positive ion mode. The methods were partially validated in terms of inter-day accuracy and precision, extraction recovery, benchtop and freeze/thaw stability. Further, the potential of ionization suppression resulting from endogenous components of the biological matrixes on the HILIC/API-MS/MS methods were investigated using the post-column infusion technique. 相似文献
12.
Recent work on a new, higher sensitivity preamplifier design for Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) revealed a number of artifact peaks (spectral features) which do not contain useful chemical information. In order to determine the cause of these artifacts and eliminate them, these severely distorted spectra were compared with similarly distorted signal models. The source of several common signal processing artifacts was thereby determined and correlated to radio‐frequency interference (RFI) noise and saturation of the amplifier and/or the digitizer. Under such conditions, the fast Fourier transform (FFT) generates spectral artifact peaks corresponding to harmonics and mixing frequencies of the real signal peaks and RFI frequencies. While this study was done using FTICRMS data, it is important to stress that these artifacts are inherent to the digitization and FFT process and thus are relevant to any FT‐based MS instrument, including the orbitrap and FT ion trap. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
13.
A sensitive hydrophilic interaction liquid chromatography/electrospray ionization mass spectrometry (HILIC/ESI-MS/MS) method was developed for determination of selected aliphatic (i.e. malonic, succinic, glutaric, adipic, pimelic, suberic, azelaic, maleic, fumaric, glycolic and pyruvic acid), alicyclic (i.e. cis-pinonic and pinic acid) and aromatic (i.e. trimesic, phthalic acid and its isomers) carboxylic acids. Analytes were separated on an amide column using a gradient elution with a 10mM constant ionic strength mobile phase containing acetonitrile and aqueous ammonium acetate buffer (pH 5.0). The influence of the buffer type, pH, polar modifier and temperature on analyte retention under HILIC was studied. Static sonication-assisted solvent extraction was optimized for sample preparation prior to analysis. The recoveries obtained were higher than 90% for most analytes. The method was proven to be sensitive with limits of detection ranged from 0.03 to 16.0 μg/L in selected reaction monitoring mode (SRM). The repeatability and intermediate precision of the method, expressed as RSD (%) of the peak area ratio between analytes and their internal standards were generally lower than 5%. The method was successfully applied for determination of the studied acids in samples of ambient aerosol particles. A big advantage of the new method is also its ability to detect and separate the isobaric compounds of the selected carboxylic acids. Our results demonstrate that the method is specific and sensitive for the determination of a wider range of polar carboxylic acids at low concentrations in complex samples of aerosol particles. 相似文献
14.
Fast quantification of endogenous carbohydrates in plasma using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry 下载免费PDF全文
Bangjie Zhu Feng Liu Xituo Li Yan Wang Xue Gu Jieyu Dai Guiming Wang Chao Yan 《Journal of separation science》2015,38(1):34-41
Endogenous carbohydrates in biosamples are frequently highlighted as the most differential metabolites in many metabolomics studies. A simple, fast, simultaneous quantitative method for 16 endogenous carbohydrates in plasma has been developed using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry. In order to quantify 16 endogenous carbohydrates in plasma, various conditions, including columns, chromatographic conditions, mass spectrometry conditions, and plasma preparation methods, were investigated. Different conditions in this quantified analysis were performed and optimized. The reproducibility, precision, recovery, matrix effect, and stability of the method were verified. The results indicated that a methanol/acetonitrile (50:50, v/v) mixture could effectively and reproducibly precipitate rat plasma proteins. Cold organic solvents coupled with vortex for 1 min and incubated at –20°C for 20 min were the most optimal conditions for protein precipitation and extraction. The results, according to the linearity, recovery, precision, matrix effect, and stability, showed that the method was satisfactory in the quantification of endogenous carbohydrates in rat plasma. The quantified analysis of endogenous carbohydrates in rat plasma performed excellently in terms of sensitivity, high throughput, and simple sample preparation, which met the requirement of quantification in specific expanded metabolomic studies after the global metabolic profiling research. 相似文献
15.
Harir M Frommberger M Gaspar A Martens D Kettrup A El Azzouzi M Schmitt-Kopplin P 《Analytical and bioanalytical chemistry》2007,389(5):1459-1467
The photodecomposition of imazamox, a herbicide of the imidazolinone family, was investigated in pure water. The main photoproducts
from the photolysis were followed over time by liquid chromatography mass spectrometry and structures were proposed from exact
mass determinations obtained by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. The method
comprised exact mass determination with better than 0.2 ppm mass accuracy and a corresponding structural visualization taking
care of respective isotopes with an adapted van Krevelen diagram that enabled a systematic approach to the characterisation
of the elementary composition of each photoproduct. By taking advantage of the high resolving power of FT-ICR MS to make precise
formula assignments, the derived 2D van Krevelen diagram (O/C; H/C; m/z) enabled one to structurally differentiate the formed photoproducts and to propose a degradation pathway for imazamox.
Figure Overview of applied method to analyse the photolysis process of imazamox herbicide 相似文献
16.
Chen X Lou Z Zhang H Tan G Liu Z Li W Zhu Z Chai Y 《Rapid communications in mass spectrometry : RCM》2011,25(11):1661-1674
An approach for the identification of multiple components in traditional Chinese medicine injections (TCMIs) using a combination of hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) coupled with time-of-flight mass spectrometry (TOFMS) was developed for the quality control of Guanxinning injection (GXNI), a widely used TCMI, composed of Salvia miltiorrhiza and Ligusticum Chuanxiong. A total of 50 compounds from five compound classes, including saccharides, amino acids, organic acids, phenolic acids and phthalides, were identified or tentatively characterized on the basis of accurate mass measurements and subsequent TOFMS product ions. Six groups of isomers of phenolic acids and saccharides were tentatively distinguished. It was observed that the ESI-TOFMS fragmentation behavior of phthalides was different in negative and positive ion mode, and the fragmentation pathways were tentatively elucidated using structurally-relevant product ions. Several highly polar constituents were characterized for the first time from GXNI by HILIC/TOFMS. In addition, all the constituents identified from GXNI were further assigned in the two individual crude drugs. The integrated strategy has provided a powerful approach for the separation and identification of the multiple components in GXNI, and it has also assisted in the establishment of methods for the comprehensive safety and quality evaluation of TCMIs. 相似文献
17.
Fei Han Yan-ting Li Xin-juan Mao Xiao-shu Zhang Jiao Guan Ai-hua Song Ran Yin 《Analytical and bioanalytical chemistry》2016,408(7):1975-1981
18.
Fourier transform infrared spectrometry (FTIR) used as a detection method for gas chromatography (GC) enhances the analytical performance of GC for the identification of eluted compounds. GC—FTIR technology has a major application in toxicological and forensic analysis. 相似文献
19.
A simple method was developed to determine histamine, an important compound in chemical food poisoning, by extraction followed by hydrophilic interaction chromatography-tandem mass spectrometry using a hydrophilic column with sulfobetaine-type zwitterion groups. The quantitation range in seafood products was from 0.4 to 200 mg kg(-1) for 5 g food samples. Quantitative recoveries were obtained with four types of seafood product. These results agreed well with those from the more complex, conventional HPLC method, which requires sample derivatization with dansyl chloride. 相似文献
20.
Takegawa Y Ito H Keira T Deguchi K Nakagawa H Nishimura S 《Journal of separation science》2008,31(9):1585-1593
Capillary zwitterionic-type hydrophilic interaction chromatography (ZIC-HILIC)/ESI-MS has been applied to the Glu-C digest of recombinant human erythropoietin (rhEPO) expressed in Chinese hamster ovary (CHO) cells. N-Glycopeptides (105) and O-glycopeptides (8) were detected in a single run of the capillary ZIC-HILIC/ESI-MS analysis. Among them, N-acetyl-neuraminic acids (Neu5Ac) of N- and O-glycans were partially acetylated and some were replaced with N-glycoyl-neuraminic acid (Neu5Gc). Their retentions in the ZIC-HILIC separation can be explained to some extent with the degree of acetylation and N-glycoylation, both of which influence the hydrophilicity/hydrophobicity of the N- and O-glycan moieties of glycopeptides. 相似文献