首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Metformin is an antihyperglycemic drug that exhibits some antioxidant properties. HO*-induced oxidation of metformin was studied in aqueous solution, in both aerated and deaerated conditions. Gamma radiolysis of water was used to generate HO* free radicals, capable of initiating one-electron oxidation of metformin. Oxidation end-products were identified by direct infusion mass spectrometry (MS) and high-performance liquid chromatography/mass spectrometry (HPLC/MSn): for every product, structure elucidation was based on its mass (simple mass spectra confirmed by HPLC/MS). In addition, fragmentation spectra (MS2, MS3 and MS4) and the determination of deuterium-hydrogen exchange sites provided valuable information allowing the complete identification of some of the end-products. At low radiation dose, four products were identified as primary ones, since they result from the direct attack of HO* radicals on metformin. These primary oxidation end-products were identified respectively as hydroperoxide of metformin, covalent dimer of metformin, methylbiguanide and 2-amino-4-imino-5-methyl-1,3,5-triazine. At high radiation dose, seven other products were identified as secondary ones, resulting from the HO*-induced oxidation of the primary end-products. A reaction scheme was postulated for the interpretation of the results.  相似文献   

2.
The proanthocyanidins in three foods (pinto beans, plums and cinnamon) were studied with electrospray ionization (ESI) mass spectrometry (MS) in the negative mode following separation by normal-phase high-performance liquid chromatography. The MS/MS analysis demonstrated that the major ions derived from heterocyclic ring fission and retro-Diels-Alder reaction of flavan-3-ol provided information about the hydroxylation pattern and type of interflavan bond. The connection sequence of the oligomers was identified through diagnostic ions derived from quinone methide (QM) cleavage of the interflavan bond. Novel heterogeneous B-type proanthocyanidins containing (epi)afzelechin as subunits were identified in pinto beans. Proanthocyanidins with interestingly different A-type linkages were identified in plums and cinnamon. In efforts aimed at extending the identification capacity of ESI-MS to polymers, we found that the polymeric procyanidins fragmented readily instead of forming multiply charged ions in the negative ESI mode. Fragmentation patterns were proposed based on our data obtained by ESI-MS/MS and ESI time-of-flight MS.  相似文献   

3.
4.
Liquid chromatography coupled with ionspray mass spectrometry in the tandem mode (LC/MS/MS) with negative ion detection was used for the identification of a variety of phenolic compounds in a cocoa sample. Gradient elution with water and acetonitrile, both containing 0.1% HCOOH, was used. Standard solutions of 31 phenolic compounds, including benzoic and cinnamic acids and flavonoid compounds, were studied in the negative ion mode using MS/MS product ion scans. At low collisional activation, the deprotonated molecule [M - H](-) was observed for all the compounds studied. For cinnamic and benzoic acids, losses of CO(2) or formation of [M - CH(3)](-*) in the case of methoxylated compounds were observed. However, for flavonol and flavone glycosides, the spectra present both the deprotonated molecule [M - H](-) of the glycoside and the ion corresponding to the deprotonated aglycone [A - H](-). The latter ion is formed by loss of the rhamnose, glucose, galactose or arabinose residue from the glycosides. Different fragmentation patterns were observed in MS/MS experiments for flavone-C-glycosides which showed fragmentation in the sugar part. Fragmentation of aglycones provided characteristic ions for each family of flavonoids. The optimum LC/MS/MS conditions were applied to the characterization of a cocoa sample that had been subjected to an extraction/clean-up procedure which involved chromatography on Sephadex LH20 and thin-layer chromatographic monitoring. In addition to compounds described in the literature, such as epicatechin and catechin, quercetin, isoquercitrin (quercetin-3-O-glucoside) and quercetin-3-O-arabinose, other compounds were identified for the first time in cocoa samples, such as hyperoside (quercetin-3-O-galactoside), naringenin, luteolin, apigenin and some O-glucosides and C-glucosides of these compounds.  相似文献   

5.
Initiation by diethyl peroxydicarbonate (E‐PDC), di‐n‐tetradecyl peroxydicarbonate (nTD‐PDC), di‐n‐hexadecyl peroxydicarbonate (nHD‐PDC), and di‐2‐ethylhexyl peroxydicarbonate (2EH‐PDC) of free‐radical polymerizations of methyl methacrylate in benzene solution was studied by end‐group analysis via electrospray ionization mass spectrometry (ESI‐MS). Unambiguous assignment of ESI‐MS peaks allows for identification of the type of radical that starts chain growth. In case of initiation by dialkyl peroxydicarbonates with linear alkyl groups, almost exclusively alkoxy carbonyloxyl species, which are the primary fragments from initiator decomposition, occur as end‐groups. With 2EH‐PDC, however, both the primary 2‐ethylhexoxy carbonyloxyl fragment and a second moiety, which is formed by decarboxylation of the 2‐ethylhexoxy carbonyloxyl radical, are clearly observed as end‐groups. The decarboxylation process is described by a concerted mechanism which involves a 1,5‐hydrogen shift reaction. © 2008 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 46: 6071–6081, 2008  相似文献   

6.
A method has been developed for the analysis and characterization in equine urine and plasma of iridoid glycosides: harpagide, harpagoside and 8-para-coumaroyl harpagide, which are the main active principles of Harpagophytum, a plant with antiinflammatory properties. The method involves liquid chromatography coupled with positive electrospray ionization mass spectrometry. The addition of sodium or lithium chloride instead of formic acid in the eluting solvent has been studied in order to enhance the signal and to modify the ion's internal energy. Fragmentation pathways and associated patterns are proposed for each analyte. A comparison of three types of mass spectrometer: a 3D ion trap, a triple quadrupole and a linear ion trap, has been conducted. The 3D ion trap was selected for drug screening analysis whereas the linear ion trap was retained for identification and quantitation analysis.  相似文献   

7.
The recently discovered native endomorphins play an important role in opioid analgesia, but their metabolic fate in the organism remains relatively little known. This paper describes the application of high-performance liquid chromatography combined with electrospray ionization mass spectrometry to identify the degradation products resulting from the incubation of endomorphins with proteolytic enzymes. The native endomorphin-1, H-Tyr-Pro-Trp-Phe-NH2 (1), and endomorphin-2, H-Tyr-Pro-Phe-Phe-NH2 (2), and an analog of endomorphin-2, H-Tyr-Pro-Phe-Phe-OH (3), were synthetized, and the levels of their resistance against carboxypeptidase A, carboxypeptidase Y, aminopeptidase M and proteinase A were determined. The patterns of peptide metabolites identified by this method indicated that carboxypeptidase Y first hydrolyzes the C-terminal amide group to a carboxy group, and then splits the peptides at the Trp3-Phe4 or Phe3-Phe4 bond. The remaining fragment peptides are stable against the enzymes investigated. Carboxypeptidase A degrades only analog 3 at the Phe3-Phe4 bond. Aminopeptidase M cleaves the peptides at the Pro2-Trp3 or Pro2-Phe3 bond. The C-terminal fragments hydrolyze further, giving amino acids and Phe-NH2-s while the N-terminal part displays a resistance to further aminopeptidase M digestion. Proteinase A exhibits a similar effect to carboxypeptidase Y: the C-terminal amide group is first converted to a carboxy group, and one amino acid is then split off from the C-terminal side.  相似文献   

8.
9.
Summary A gas chromatographic/mass spectrometric method is described for the determination of mono- and dioctyltinchloride (MOTC and DOTC). Quantitative extraction from aqueous solutions was obtained with diethyl ether at pH=2. Several derivatization methods were tested. Grignard butylation in closed systems was most efficient. In the selected ion monitoring mode, the detection limits were 5 ng/ml for MOTC and 50 ng/ml for DOTC with a mean coefficient of variation of approximately 15%. Calibrations from different matrices were performed, e.g. from water, hepatocyte suspensions, urine and feces. The water solubility of DOTC was determined as 0.7 mg/l.  相似文献   

10.
11.
12.
Most prior analytical studies have dealt with the determination of chemical warfare agents in environmental or biological matrices that would typically be collected following battlefield use or in support of the Chemical Weapons Convention. These methods may be useful for some investigations, but may not be practical for indoor forensic investigations where chemical warfare agent use is suspected. There is a need for analytical methods for chemical warfare agent identification in office media, including flooring, wall surfaces, office fabrics and paper products, which would typically be collected in an office environment during forensic investigations. During this study, typical office environment media were spiked at the 4-20microg/g level with either a complex munitions grade sample of tabun (GA) or with a standard containing the three nerve agents, sarin (GB), cyclohexyl methylphosphonofluoridate (GF), soman (GD) and the nerve agent simulant, triethyl phosphate (TEP), to evaluate the potentials of liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) and liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for forensic purposes. An emerging technique, desorption electrospray ionization (DESI-MS/MS), was also investigated for the direct determination of TEP, GB and GD sampled onto solid phase microextraction (SPME) fibers exposed to spiked office media. The spiked chemical warfare agents were recovered with varying efficiencies during this study, but in all cases sufficient chemical warfare agent was recovered for mass spectrometric identification purposes. Full high resolution mass spectra were acquired for all the chemical warfare agents in the continuum mode, which typically resulted in mass measurement errors of 0.001Da or less.  相似文献   

13.
Tebuconazole is a widely used fungicide. The formation of by-products on irradiated titanium dioxide as a photocatalyst was evaluated. Several species derived from tebuconazole degradation were identified and characterized by HPLC/MS(n). A pattern of reactions accounting for the observed intermediates is proposed. Different parallel pathways are operating (and through these pathways the transformation of the molecule proceeds), leading to a wide range of intermediate compounds. All these molecules are more hydrophylic than tebuconazole. The main steps involved are (1) the hydroxylation of the molecule with the formation of three species having [M + H](+) 324; the hydroxylation occurs on the C-1 carbon and on the aromatic ring in the two ortho-positions; (2) the cleavage of a C--C bond with the release of the tert-butyl moiety and the formation of a species having m/z 250; analogously to step 1, also on this species a further hydroxylation reaction occurs; (3) through the loss of the triazole moiety with the formation of a structure with m/z 257.  相似文献   

14.
A liquid chromatographic/electrospray ionization tandem mass spectrometric method for the quantification of the synthetic opiate buprenorphine (BUP), norbuprenorphine (NBUP), buprenorphine-3-beta-D-glucuronide (BUP-3-G) and norbuprenorphine-3-beta-D-glucuronide (NBUP-3-G) in human plasma was developed and validated. Identification and quantification were based on the following transitions: m/z 468 to 396 and 414 for BUP, m/z 414 to 326 and 340 for NBUP, m/z 644 to 468 for BUP-3-G and m/z 590 to 414 for NBUP-3-G. Calibration by linear regression analysis utilized deuteratated internal standards and a weighting factor of 1/x. The method was accurate and precise across a linear dynamic range of 0.6-50.0 ng ml(-1). Pretreatment of plasma samples using solid-phase extraction was sufficient to limit matrix suppression to <30% for all four analytes. The method proved to be suitable for the quantification of BUP and the related metabolites in plasma samples collected from BUP-maintained study participants.  相似文献   

15.
Electrospray ionization mass spectrometry was performed to identify the structure of polymeric methyl acrylates generated via the cumyl dithiobenzoate (CDB), cumyl p‐fluorodithiobenzoate (CPFDB), and 1‐phenylethyl dithiobenzoate (PEDB) mediated reversible addition–fragmentation chain‐transfer (RAFT) polymerizations. The relatively simple spectra clearly demonstrate the end groups of this living free‐radical polymerization technique. Only polymeric chains carrying one leaving group of the RAFT agent and the dithiobenzoate end group as the active RAFT center were discovered. Multiple‐stage mass spectrometric experiments and oxidation of the dithioester end group confirmed the structure of the generated polymers. © 2002 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 40: 4032–4037, 2002  相似文献   

16.
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simple single-step liquid-liquid extraction with tert-butyl methyl ether. The analyte was chromatographed on an Xterra MS C(18) reversed-phase chromatographic column by isocratic elution with 20 mM ammonium acetate buffer-acetonitrile (10:90, v/v; pH 6) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 456.4 --> 354.4 and m/z 409.3 --> 238.3 were used to measure the analyte and the I.S., respectively. The chromatographic run time was 1.5 min and the weighted (1/x(2)) calibration curves were linear over the range 0.1-25 ng ml(-1). Lacidipine was sensitive to temperature in addition to light. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 50 and 100 pg ml(-1), respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<15%). The analyte was stable after three freeze-thaw cycles (deviation <15%). The average absolute recoveries of lacidipine and amlodipine (IS) from spiked plasma samples were 51.1 +/- 1.3 and 50.3 +/- 4.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of lacidipine.  相似文献   

17.
18.
19.
Fragmentations of the protonated adduct ions [M+H](+) of seven 1,4-benzoxazepine derivatives were studied using 'post-source decay' matrix-assisted laser desorption/ionization (PSD MALDI) and electrospray nozzle-skimmer collisionally induced dissociation (ESI-CID) mass spectrometric methods. It was found that both methods generated mainly product ions arising from the cross-ring cleavages of the benzoxazepine ring. Similar product ions were generated under MALDI and ESI conditions; however, it was observed that the loss of the alkylene unit from the N-substituted benzoxazepine, and the loss of a H(2)X molecule (where X = O or S), are more preferred under ESI conditions. Based on the experimental results a mechanism is also proposed for the fragmentation of the oxazepines studied.  相似文献   

20.
The main degradation by-products of the herbicide chlortoluron formed during water disinfection with HOCl/ClO(-) have been separated and identified by liquid chromatography/electrospray ionisation sequential mass spectrometry (LC/ESI-MS(n)). Chlorination and hydroxylation reactions seem to occur exclusively on the aromatic ring of chlortoluron, leading to by-products which show characteristic fragmentation patterns. Indeed, chlortoluron-like ESI spectra were always observed for chlorinated by-products, showing only a fragment at m/z 72. In contrast, hydroxylated and chloro/hydroxylated by-products gave a much more complex fragmentation pattern that could be elucidated by MS(n) (n = 1-4) experiments. A mechanistic scheme rationalising the observed fragmentation pattern is proposed and discussed. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号