首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Diazeniumdiolates (also called NONOates) have been analyzed by electrospray ionization mass spectrometry (ESI-MS). The samples used are commercially available and included Diethylamine NONOate, DETA NONOate, Spermine NONOate, MAHMA NONOate, PROLI NONOate, Dipropylenetriamine NONOate, PAPA NONOate, and Sulpho NONOate. These compounds have been found to ionize upon ESI by protonation, deprotonation and sodiation. The MS(n) experiments provided strong evidence that such ions release NO, HNO, N(2)O, NO(2), N(2)O(2), N(3)O(3), N(4)O(3) and N(4)O(4) when collisionally activated. Thus, the facile donation of NO units is a property of such compounds. Negative-mode mass spectrometry has been particularly useful for the analysis of most of the NONOates studied here. The experiments have demonstrated the capabilities of mass spectrometry, along with CAD (MS/MS), to detect and characterize such compounds.  相似文献   

2.
3.
Desorption electrospray ionization (DESI) is a droplet‐based ionization method that is applied to samples in the ambient environment with little or no sample preparation. Its utility for industrial applications is explored here for the case of pharmaceutical cleaning validation. A non‐proximate large‐area DESI system was built to examine representative areas of the surfaces of reaction vessels used in active product ingredient (API) manufacturing. A large‐area sprayer capable of sampling an area of ~2.5 cm2 was coupled with a transport tube to allow sensitive, representative sampling of APIs from a stainless steel surface 1 m away from the mass spectrometer. The system was used to detect the APIs neostigmine, acebutolol, amiloride, amiodarone, ibuprofen, montelukast, potassium clavulanate, and β‐estradiol, at levels as low as 30–10 ng/cm2, easily satisfying the general acceptable limits set by the pharmaceutical industry. These levels were achieved from surfaces resembling the equipment used in API manufacturing processes at a rate of 30 s per analysis. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

4.
A new ion source has been developed for rapid, noncontact analysis of materials at ambient conditions. The method provides desorption of analytes under ambient conditions directly from different surfaces with little or no sample preparation. The new method, termed electrode‐assisted desorption electrospray ionization (EADESI), is on the basis of the ionization of molecules on different surfaces by highly charged droplets produced on a sharp‐edged high voltage tip, and ions produced are introduced into the mass spectrometer through a capillary. The EADESI technique can be applied to various samples including amino acids, peptides, proteins, drugs and human fluids such as urine and blood. EADESI is promising for routine analyses in different fields such as forensic, environmental and material sciences. EADESI interface can be fit to a conventional ion‐trap mass spectrometer. It can be used for various types of samples with a broad mass range. EADESI can also provide real‐time analysis which is very valuable for biomedical applications. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

5.
6.
7.
Probe electrospray ionization (PESI) is a modified version of the electrospray ionization (ESI), where the capillary for sampling and spraying is replaced by a solid needle. High tolerance to salts and direct ambient sampling are major advantages of PESI compared with conventional ESI. In this study, PESI‐MS was used to monitor some biological and chemical reactions in real‐time, such as acid‐induced protein denaturation, hydrogen/deuterium exchange (HDX) of peptides, and Schiff base formation. By using PESI‐MS, time‐resolved mass spectra and ion chromatograms can be obtained reproducibly. Real‐time PESI‐MS monitoring can give direct and detailed information on each chemical species taking part in reactions, and this is valuable for a better understanding of the whole reaction process and for the optimization of reaction parameters. PESI‐MS can be considered as a potential tool for real‐time reaction monitoring due to its simplicity in instrumental setup, direct sampling with minimum sample preparation and low sample consumption. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
Alkaline metal adduct ions of sphingomyelin were formed by electrospray ionization in positive ion mode. Under low energy collisionally activated dissociation (CAD), the product ion spectra yield abundant fragment ions representative of both long chain base and fatty acid which permit unequivocal determination of the structure. Tandem spectra obtained by constant neutral loss scanning permit identification of sphingomyelin class and specific long chain base subclass in the mixture. The fragmentation pathways under CAD were proposed, and were further confirmed by source CAD tandem mass spectrometry. The total analysis of sphingomyelin mixtures from bovine brain, bovine erythrocytes, and chicken egg yolk is also presented.  相似文献   

9.
A 193‐nm wavelength deep ultraviolet laser was used for ambient laser ablation electrospray ionization mass spectrometry of biological samples. A pulsed ArF excimer laser was used to ablate solid samples, and the resulting plume of the desorbed material merged with charged electrospray droplets to form ions that were detected with a quadrupole time‐of‐flight mass spectrometer. Solutions containing peptide and protein standards up to 66‐kDa molecular weight were deposited on a metal target, dried, and analyzed. No fragmentation was observed from peptides and proteins as well as from the more easily fragmented vitamin B12 molecule. The mass spectra contained peaks from multiply charged ions that were identical to conventional electrospray. Deep UV laser ablation of tissue allowed detection of lipids from untreated tissue. The mechanism of ionization is postulated to involve absorption of laser energy by a fraction of the analyte molecules that act as a sacrificial matrix or by residual water in the sample.  相似文献   

10.
Ageing products of a commercial jet engine oil based on pentaerythritol tetraesters which were formed upon operation in an aviation turbine were detected by electrospray ionization mass spectrometry (ESI-MS) and characterized by LC-ESI-MS. The fatty acid composition of these ageing products was investigated by ESI-MS-MS analysis. The ammonium adducts of the newly formed pentaerythritol tetraester degradation products were found to be suitable parent ions for further structure elucidation work. ESI-MS, LC-ESI-MS and ESI-MS-MS proved to be versatile tools to study the chemical composition (distribution of homologues) as well as the mechanism of ageing of ester based lubricants on a molecular level. Due to its high sensitivity, ESI-MS can also be used to characterize and identify trace levels of ester-based lubricants.  相似文献   

11.
12.
13.
14.
Arsenic pollution of public water supplies has been reported in various regions of the world. Recently, some cancer patients are treated with arsenite (AsIII); most Japanese people consume seafoods containing large amounts of negligibly toxic arsenic compounds. Some of these arsenic species are metabolized, but some remain intact. For the determination of toxic AsIII, a simple, rapid and sensitive method has been developed using electrospray ionization mass spectrometry (ESI-MS). AsIII was reacted with a chelating agent, pyrrolidinedithiocarbamate (PDC, C4H8NCSS-) and tripyrrolidinedithiocarbamate-arsine, As(PDC)3, extracted with methyl isobutyl ketone (MIBK). A 1 μL aliquot of MIBK layer was directly injected into ESI-MS instrument without chromatographic separation, and was detected within 1 min. Arsenate (AsV) was reduced to AsIII with thiosulfate, and then the total inorganic As was quantified as AsIII. This method was validated for the analysis of urine samples. The limit of detection of As was 0.22 μg L−1 using 10 μL of sample solution, and it is far below the permissible limit of As in drinking water, 10 μg L−1, recommended by the WHO. Results were obtained in < 10 min with a linear calibration range of 1-100 μg L−1. Several organic arsenic compounds in urine did not interfere with AsIII detection, and the inorganic As in the reference materials SRM 2670a and 1643e were quantified after the reduction of AsV to AsIII.  相似文献   

15.
Dimethylglycine (DMG) esters are new derivatives for the rapid, sensitive and selective analysis of primary and secondary alcohols, in complex mixtures, by electrospray ionization tandem mass spectrometry (ESI-MS/MS). Their development was inspired by the use of the complementary dimethylaminoethyl esters for the trace, rapid analysis of fatty acids. DMG esters are simply prepared by heating a dichloromethane solution of the imidazolide of dimethylglycine, containing triethylamine, and an alcohol. DMG esters of long-chain fatty alcohols, isoprenoidal alcohols and hydroxy-acids are analysed by electrospray ionization tandem mass spectrometry with a precursor ion of m/z 104 scan. Diols, glyceryl esters, glyceryl ethers and some sterols are analysed by a neutral loss of 103 Da scan. Trimethylglycine (TMG) ester iodides, prepared by alkylation of DMG esters with methyl iodide, are more sensitive derivatives for molecules containing secondary alcohol groups, such as cholesterol and gibberellic acid. They are analysed by a precursor ion of m/z 118 scan. DMG or TMG derivatives were shown to be at least comparable and sometimes an order of magnitude more sensitive than N-methylpyridyl ether derivatives for ESI-MS/MS analysis of the different classes of alcohols. Applications of these derivatives for the diagnosis of inherited disorders and the analysis of natural products are presented.  相似文献   

16.
17.
By electrospray ionization (ESI) mass spectrometry, micelle solutions of sodium cholate were investigated in detail in the presence and absence of ethanol. The average aggregation number could be evaluated from the spectra acquired under conditions where soft collisions adequate to measure the micelle solution were induced, and the value agreed well with that obtained previously by other methods. From the dependence on ethanol content, it was also found that the average aggregation number in aqueous solution without organic solvent could be reliably estimated. The ESI method proved to be a useful tool for determining the micelle mass in the original aqueous phase.  相似文献   

18.
19.
20.
In this study, different electrospray ionization mass spectrometric (ESI‐MS) methods were utilized to analyze several pairs of taxane stereoisomers including paclitaxel and 7‐epi‐paclitaxel. Both ESI‐MS and tandem mass spectrometry (MS/MS) techniques provided stereochemically dependent mass spectra in negative‐ion mode, and all studied stereoisomers could be easily distinguished based on their characteristic ions or distinct fragmentation patterns. MS/MS experiments for several taxane analogues at various collision energies were performed to elucidate potential dissociation pathways. The gas‐phase deprotonation potentials were also calculated to estimate the most thermodynamically favorable deprotonation site using DFT B3LYP/6‐31G(d). The results of the theoretical studies agreed well with the fragmentation patterns of paclitaxel and 7‐epi‐paclitaxel observed from MS/MS experiments. In addition, it was found that liquid chromatography (LC)/ESI‐MS was a useful and sensitive technique for assignment of C‐7 taxane stereoisomers from realistic samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号