首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
The effect of metabolite interference during liquid chromatography/tandem mass spectrometry (LC/MS/MS) analysis of an amine drug was investigated using FAIMS (high‐Field Asymmetric waveform Ion Mobility Spectrometry). The selected reaction monitoring (SRM) transition used for the drug exhibited an interference due to in‐source conversion of the N‐oxide metabolite to generate an ion isobaric with the drug. The on‐line FAIMS device removed the metabolite interference before entrance to the mass spectrometer. FAIMS was used to demonstrate the relative accuracy and precision of drug analysis even in the presence of a co‐eluting metabolite that may undergo in‐source conversion. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

4.
Nanoelectrospray ionization (nESI) coupled online with high‐field asymmetric waveform ion mobility spectrometry (FAIMS) for small molecule analysis in a discovery pharmaceutical setting was examined. A conventional capillary pump, autosampler and nESI source were used to introduce samples directly into the FAIMS device. The FAIMS device was used to separate gas‐phase ions on a timescale that was compatible with the mass spectrometer. The capability of the nESI‐FAIMS combination to efficiently remove metabolite interferences from the parent drug, and reduce ion suppression effects, was demonstrated. On average, 85% of the signal intensity obtained from a neat sample was preserved in the extracted plasma samples. Standard curves were prepared for several compounds. Linearity was obtained over approximately 3 to 4 orders of magnitude. Comparison of results from nESI‐FAIMS with those from conventional LC/MS for a mouse pharmacokinetic study yielded concentration values differing by no more than 30%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
The analysis of peptides presents serious challenges for bioanalytical scientists including low total ion current and non‐selective fragmentation during tandem mass spectrometry (MS/MS). During method validation of a peptide in rat serum matrix some interferences could not be easily removed and thus prevented accurate and precise measurement. These problems associated with peptide quantitation were resolved by using FAIMS (high‐Field Asymmetric waveform Ion Mobility Spectrometry). This selectivity‐enhancing technique filters out matrix interferences, and the resulting pseudo‐selected reaction monitoring (pseudo‐SRM) chromatograms were nearly free from interferences. Control blank matrix samples contained an acceptable level of interference (only 7% signal as compared to the lower level of quantitation). Chromatographic peaks were easily, accurately and precisely integrated resulting in a validated liquid chromatography (LC)/FAIMS‐MS/MS method for the analysis of a peptide drug in rat serum according to United States Food and Drug Administration (US FDA) bioanalytical guidelines. These results confirm that new selectivity‐enhancing technologies aid the pharmaceutical industry in reliably producing acceptable pharmacokinetic data. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
For the determination of trace level impurities, analytical chemists are confronted with complex mixtures and difficult separations. New technologies such as high‐field asymmetric waveform ion mobility spectrometry (FAIMS) have been developed to make their work easier; however, efficient method development and troubleshooting can be quite challenging if little prior knowledge of the factors or their settings is available. We present the results of an investigation performed in order to obtain a better understanding of the FAIMS technology. The influence of eight factors (polarity of dispersion voltage, outer bias voltage, total gas flow rate, composition of the carrier gas (e.g. %He), outer electrode temperature, ratio between the temperatures of the inner and outer electrodes, flow rate and composition of the make‐up mobile phase) was assessed. Five types of responses were monitored: value of the compensation voltage (CV), intensity, width and asymmetry of the compensation voltage peak, and resolution between two peaks. Three types of studies were performed using different test mixtures and various ionisation modes to assess whether the same conclusions could be drawn across these conditions for a number of different types of compounds. To extract the maximum information from as few experiments as possible, a Design of Experiment (DoE) approach was used. The results presented in this work provide detailed information on the factors affecting FAIMS separations and therefore should enable the user to troubleshoot more effectively and to develop efficient methods. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

7.
We have applied high‐field asymmetric waveform ion mobility spectrometry (FAIMS) to the analysis of the phosphopeptides APLpSFRGSLPKSYVK, APLSFRGpSLPKSYVK, and APLSFRGSLPKpSYVK. The peptides have identical amino acid sequences and differ only in the site of phosphorylation. The results show that FAIMS is capable of at least partially separating these species. Separation was confirmed by coupling FAIMS with high‐resolution electron transfer dissociation (ETD) mass spectrometry. Phosphorylation is retained on the ETD peptide fragments thereby allowing assignment of the site of the modification. Co‐eluting phosphopeptides which differ only in the site of modification are frequently observed in liquid chromatography/tandem mass spectrometry phosphoproteomics experiments, and therefore these proof‐of‐principle results have implications for the application of FAIMS in that field. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
High field asymmetric waveform ion mobility spectrometry (FAIMS) provides atmospheric pressure, room temperature, low-resolution separation of gas-phase ions. The FAIMS analyzer acts as an ion filter that can continuously transmit one type of ion, independent of m/z. The combination of FAIMS with electrospray ionization and mass spectrometry (ESI-FAIMS-MS) is a powerful technique and is used in this study to investigate the cluster ions of leucine enkephalin (YGGFL). Separation by FAIMS of leucine enkephalin ions having the same m/z (m/z 556.5), [M + H]+ and [2M + 2H]2+, was observed. In addition, four complex ions of leucine enkephalin, [2M + H]+, [4M + 2H]2+, [6M + 3H]3+, and [8M + 4H]4+, all having m/z 1112, were shown to be separated in FAIMS. Fragmentation of ions as the result of harsh conditions within the mass spectrometer interface (FAIMS-MS) was shown to provide similar information to that obtained from MS/MS experiments in conventional ESI-MS.  相似文献   

9.
The separation and ion focusing properties of High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) depend on desolvated ions entering the device, leading to a compound-specific, reproducible compensation voltage (CV) for each ion. This study shows that the conditions identified for stable spray and satisfactory ion desolvation in normal electrospray ionization mass spectrometry (ESI-MS) operation might significantly differ from those required for FAIMS-MS. In a typical setup with high-flow electrospray conditions, ions could be incompletely desolvated, resulting in the formation of unidentified clusters with differing behavior in a FAIMS environment. This causes compound-specific shifts of as much as 10 V in CV values when the mobile phase composition and/or flow rate are varied. The shifts diminish and finally disappear when the flow rate of methanol, used as mobile phase, is reduced to 40 microL/min and that of acetonitrile to 20 microL/min. The reproducibility of the observed CV was determined by scanning the CV while infusing a five-component mixture into a 400 microL/min flow of methanol or 50:50 acetonitrile/water. The relative standard deviation (RSD) for these multiple scans ranged from 0.7% to 6%. Therefore, under a constant set of experimental parameters, the CV does not shift appreciably. These observations have an impact on method development strategies. High flow rates can be used with the FAIMS device, since the CV values are reproducible, but it is likely that clusters are forming. Therefore, CV scans should be performed under conditions which mimic the chromatographic elution or flow injection analysis conditions, including matrix composition, to minimize errors in CV determination. An alternative approach is to determine the liquid flow rate at which the CV becomes compound-specific and to split the mobile phase stream accordingly. These experimental results may be specific to the setup used for this study and may not be directly applicable to other instrument FAIMS devices.  相似文献   

10.
An electrospray ionization (ESI) source was used to generate gas-phase molecular anions of the amino acids leucine and isoleucine ((M–H); m/z −130), which were separated by high- field asymmetric waveform ion mobility spectrometry (FAIMS) and detected by quadrupole mass spectrometry (MS). This combination of ESI-FAIMS-MS enabled selective determination of either amino acid in mixtures that contained at least a 625-fold excess of the other. Comparisons with conventional ESI-MS showed a 50-fold improvement in the signal to background ratio for a 1 μM solution of leucine.  相似文献   

11.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is a new technology for ion separation at atmospheric pressure. This review introduces the reader to FAIMS, covering topics ranging from the fundamentals and extraction of physical parameters from the raw data, to applications of FAIMS extending from homeland security to environmental analysis to proteomics. The investigation of FAIMS as an ion pre-processing tool for mass spectrometry is in its infancy, but reports in the literature illustrate that FAIMS separates isobaric ions including diastereoisomers, separates isotopes, reduces background ions by isolating ions of interest, and simplifies spectra of complex mixtures by dividing the mixture into a series of simpler subsets of ions. Applications ranging from quantitative analysis of inorganic and organometallic compounds, to studies of the conformers of intact proteins, have been reported. This review is a launching point for further exploration of FAIMS.  相似文献   

12.
High‐field asymmetric ion mobility spectrometry (FAIMS) has become an efficient technique for separation and characterization of gas‐phase ions at ambient pressure, which utilizes the mobility differences of ions at high and low fields. Micro FAIMS devices made by micro‐electromechanical system technology have small gaps of the channels, high electric field and good installation precision, as thus they have received great attentions. However, the disadvantage of relatively low resolution limits their applications in some areas. In this study, theoretical analysis and experimental exploration were carried out to overcome the disadvantage. Multiple scans, characteristic decline curves of ion transmission and pattern recognitions were proposed to improve the performance of the microchip‐based FAIMS. The results showed that although micro FAIMS instruments as a standalone chemical analyzer suffer from low resolution, by using one or more of the methods proposed, they can identify chemicals precisely and provide quantitative analysis with low detection limit in some applications. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
Effects of carrier gas type (N2, O2, CO2, N2O, and SF6) on changes in the ratio of high- to low-field ion mobility, Kh/K, of cesium, gramicidin S, tetrahexylammonium, heptadecanoic acid, and aspartic acid in fields of up to 67 Td are presented. The theory of the mobility of ions at high E/N in different gases is discussed. Plots of Kh/K as a function of the ionic energy parameter, E/N, for the five ions in each of the gases were derived from experimental data collected using a high-field asymmetric waveform ion mobility spectrometer. The change in the ratio of high- to low-field ion mobility of cesium in carrier gases of O2 and N2 showed excellent agreement with literature values. The behavior of cesium in O2 and N2 is used to illustrate that the ratio Kh/K as a function of effective temperature is invariant with gas type as long as the well depth of the interaction potential significantly exceeds thermal energy. From these results, it appears that the well depth of the interaction potential of the heavier ions studied here, including gramicidin S, tetrahexylammonium, and heptadecanoic acid, with bath gases such as N2 and O2, is shallow relative to thermal energy.  相似文献   

14.
A combination of electrospray ionization, high-field asymmetric waveform ion mobility spectrometry, and mass spectrometry (ESI-FAIMS/MS) was used to analyze standard solutions of microcystins-LR, -RR, and -YR. The ability of FAIMS to separate ions in the gas phase reduced the amount of background in the mass spectrum without compromising the absolute signal for these microcystins. This reduction in background resulted in a ten-fold improvement in the signal-to-background ratio over conventional ESI-MS. Detection limits, using direct infusion, were determined to be 4, 2, and 1 nM for microcystins-LR, -RR, and -YR, respectively.  相似文献   

15.
16.
Kolakowski BM  Mester Z 《The Analyst》2007,132(9):842-864
High-Field Asymmetric Waveform Ion Mobility Spectrometry (FAIMS) and Differential Mobility Spectrometry (DMS) harness differences in ion mobility in low and high electric fields to achieve a gas-phase separation of ions at atmospheric pressure. This separation is orthogonal to either chromatographic or mass spectrometric separation, thereby increasing the selectivity and specificity of analysis. The orthogonality of separation, which in some cases may obviate chromatographic separation, can be used to differentiate isomers, to reduce background, to resolve isobaric species, and to improve signal-to-noise ratios by selective ion transmission. This review will focus on the applications of these techniques to the separation of various classes of analytes, including chemical weapons, explosives, biologically active molecules, pharmaceuticals and pollutants. These papers cover the period up to January 2007.  相似文献   

17.
A high-field asymmetric waveform ion mobility spectrometry (FAIMS)-based method for the determination of the mycotoxin zearalenone (ZON) and its metabolites α-zearalenol (α-ZOL), β-zearalenol (β-ZOL), and β-zearalanol (β-ZAL), in a cornmeal (maize) matrix is described. Detection limits achieved using the FAIMS device coupled with electrospray ionization (ESI) and mass spectrometric (MS) detection are 0.4 ng mL−1 for ZON and 3 ng mL−1 for α-ZOL + β-ZOL, and β-ZAL. This represents a significant improvement when compared to detection limits determined using ESI-MS or ESI-tandem mass spectrometry (MSMS) analytical methods. The developed flow-injection (FIA)-ESI-FAIMS-MS method was applied to reference materials ERM-BC-716 and ERM-BC-717 certified for ZON and excellent agreement with the certified values was observed.  相似文献   

18.
The electric field dependence of the mobilities of gas-phase protonated monomers [(MH+(H2O)n] and proton-bound dimers [M2H+(H2O)n] of organophosphorus compounds was determined at E/N values between 0 and 140 Td at ambient pressure in air with moisture between 0.1 and 15 000 ppm. Field dependence was described as alpha (E/N) and was obtained from the measurements of compensation voltage versus field amplitude in a planar high-field asymmetric waveform ion mobility spectrometer. The alpha function for protonated monomers to 140 Td was constant from 0.1 to 10 ppm moisture in air with onset of effect at approximately 50 ppm. The value of alpha increased 2-fold from 100 to 1000 ppm at all E/N values. At moisture values between 1000 and 10 000 ppm, a 2-fold or more increase in alpha (E/N) was observed. In a model proposed here, field dependence for mobility through changes in collision cross sections is governed by the degree of solvation of the protonated molecule by neutral molecules. The process of ion declustering at high E/N values was consistent with the kinetics of ion-neutral collisional periods, and the duty cycle of the waveform applied to the drift tube. Water was the principal neutral above 50 ppm moisture in air, and nitrogen was proposed as the principal neutral below 50 ppm.  相似文献   

19.
Gaseous oxygen and nitrogen bases, both singly and as binary mixtures, have been introduced into ion mobility spectrometers to study the appearance of protonated molecules, and proton-bound dimers and trimers. At ambient temperature it was possible to simultaneously observe, following the introduction of molecule A, comparable intensities of peaks ascribable to the reactant ion (H2O)nH+, the protonated molecule AH+ and AH+ · H2O, and the symmetrical proton bound dimer A2H+. Mass spectral identification confirmed the identifications and also showed that the majority of the protonated molecules were hydrated and that the proton-bound dimers were hydrated to a much lesser extent. No significant peaks ascribable to proton-bound trimers were obtained no matter how high the sample concentration. Binary mixtures containing molecules A and B, in some cases gave not only the peaks unique to the individual compounds but also peaks due to asymmetrical proton bound dimers AHB+. Such ions were always present in the spectra of mixtures of oxygen bases but were not observed for several mixtures of oxygen and nitrogen bases. The dimers, which were not observable, notable for their low hydrogen bond strengths, must have decomposed in their passage from the ion source to the detector, i.e. in a time less than ∼5 ms. When the temperature was lowered to −20 °C, trimers, both homogeneous and mixed, were observed with mixtures of alcohols. The importance of hydrogen bond energy, and hence operating temperature, in determining the degree of solvation of the ions that will be observed in an ion mobility spectrometer is stressed. The possibility is discussed that a displacement reaction involving ambient water plays a role in the dissociation.  相似文献   

20.
The performance of a planar differential mobility spectrometer (DMS) is investigated when operated in air at ambient pressure and driven by a rectangular asymmetric waveform, limited to frequencies of <1.2 MHz and voltage pulse amplitudes of <1 kV with steep rise times of the order of approximately 15 ns. Independent control of frequency, voltage pulse amplitude, and duty cycle allow for characterizing the DMS in terms of transmission, resolution and separation. The tradeoff between sensitivity and resolution and the effect of duty cycle on instrument performance are demonstrated experimentally. The dependence of ion mobility on the magnitude of the electric field determines the displacement of ions measured by the DC compensation voltage as a function of the duty cycle. Optimum values for the duty cycle exist for the separation of A- and C-type ions, while, B-type ions exhibit a more complex behavior. An analytical expression for describing the effect of duty cycle on the separation of the ions, determined by variations in the compensation voltage, is developed and compared to experimental results obtained in air below 75 Td using estimated alpha parameters for a set of ketones. In this context, errors associated with the calculation of alpha parameters using polynomials of even powers are highlighted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号